Haier AB072FDBHA, AB092FEAIA, AB092FDAHA, AB092FDBHA, AB092FEBIA Instruction Manual

...
Four way cassette type
AB092FEAIA AB092FEBIA AB122FEAIA AB122FEBIA AB142FEAIA AB142FEBIA AB162FEAIA AB162FEBIA AB182FEAIA AB182FEBIA AB242FEAIA AB242FEBIA AB282FEAIA AB282FEBIA AB322FEAIA AB322FEBIA
AB362FEAIA AB362FEBIA AB452FEAIA AB452FEBIA
TWO way cassette type
AB072FDAHA AB072FDBHA AB092FDAHA AB092FDBHA
AB122FDAHA AB122FDBHA AB142FDAHA AB142FDBHA AB162FDAHA AB162FDBHA AB182FDAHA AB182FDBHA AB242FDAHA AB242FDBHA AB282FDAHA AB282FDBHA
Convertible Type
AC122FEAHA AC122FEBHA AC282FEAHA AC282FEBHA AC162FEAHA AC162FEBHA AC322FEAHA AC322FEBHA AC182FEAHA AC182FEBHA
Duct Type
AD182FIAHA AD182FIBHA AD242FIAHA AD242FIBHA
AD282FIAHA AD282FIBHA AD322FIAHA AD322FIBHA AD362FIAHA AD362FIBHA AD452FIAHA AD452FIBHA
Split Type
AS072FAAHA AS072FABHA AS142FAAHA AS142FABHA AS092FAAHA AS092FABHA AS162FAAHA AS162FABHA
AS122FAAHA AS122FABHA AS182FAAHA AS182FABHA
Ceiling concealed type
AE072FEAHA AE072FEBHA AE122FEAHA AE122FEBHA AE092FEAHA AE092FEBHA AE162FEAHA AE162FEBHA AE142FEAHA AE142FEBHA AE242FEAHA AE242FEBHA
AE182FEAHA AE182FEBHA AE242FLAHA AE242FLBHA
No. 0010570352 B
MRV Intelligent Network Indoor Air-conditioner
Please read this instruction manual before using the air conditioner Please keep this manual carefully and safely.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, antipollution method of disposal.
Disposal of the packaging of your new air conditioner
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly , operation and maintenance of the air conditioner .
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier .
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items,crushing or twisting off the surfaces. If the refrigerant spurts out and gets into eyes , it may result in serious eye injures.
Always remember to unplug the air conditioner before openning inlet grill . Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner .
Cautions
For the purpose of the safety, the air conditioner must be properly grounded in accordance with specifications.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Do not obstruct or cover the ventilation grille of the air conditioner . Do not put fingers or any other things into the inlet/outlet and swing louver .
Specifications
1) The refrigerating circuit is leak-proof.
2)Please keep the air-conditioner under conditions in the following table during operation to ensure proper use of it.
Outdoor temperature (D.B.)
Indoor temperature (W.B.)
Indoor humidity
Outdoor temperature (W.B.) Indoor temperature (D.B.)
Above-5 C and below 43 C
Above15.5 C and below24 C
Humidity under 80% Whenever air-conditioner is op­erating under circumstance with humidity above 80% for long term, defrosting shall be formed and dropped on the machine surface, mirage shall be blew off from the outlet.
Above-15 C and below 15.5 C
Above-15 C and Below 28 C
Cooling Heating
3)The wiring diagram refer to the wiring diagram on the indoor and ortdoor units.
4) If the fuse on electrical heater is broken please change it with the type of AC 250V 15A If the fuse on main circuit is broken please change it with the same type ofAC 250V 5A
5)For AS072 ~ 182FA AHA the indoor unit installation height is at least 2.0m.
1
Important Points of Safety
2
The following four important points of safety and suggestions should be paid great attention:
Comply with the following important points of safety . Put these important points of attention and suggestions nearby and convenient for reference in need. Hand over this instruction manual to new user if you resell this machine.
Entrusted Installation Installation of the machine should be entrusted to certified person of after service. Unauthorized installation may cause water leakage, electric shock or fire hazard for improper operation.
To prevent leakage of refrigerant, let certified person of after service do it.
Leakage of refrigerant over certain consistence may result in shortage of oxygen. Enough precautions MUST be done to avoid oxygen shortage in case of refrigerant leaking if the room where the air-conditioner is installed is small.
The power supply must be fitted with earth line to ensure valid earthing of the air-conditioner. No or incomplete earthing connection may cause the risk of electric shock.
Warning
Warning for installation
Warning for use Warning for move and repair
Avoid your body being blown directly by cold wind for long period, otherwise your health may be affected.
When you have to disassemble and reinstall the machine, entrust it to after service. Improper installation may cause fire hazard, electric shock or damage of machine.
If something abnormal (e.g.: burnt smell etc.) occurs, stop running the machine, shut down the manual power switch and contact after service. Continuous operation in disorder may cause fire hazard or electric shock etc.
Unauthorized alteration or repair work is strictly forbidden. Improper alteration or maintenance may cause fire hazard, electric shock or water leakage. Repair work should be entrusted to certified person of after service.
Attention points for installation
Ensure the drainage hose work normally during installation. Improper installation of drainage can cause water leakage and damp articles.
Ensure electric leakage breaker being installed. Electric leakage breaker MUST be installed, otherwise electric shock may be caused.
DO NOT install the machine in place where flammable gas releases easily to avoid fire hazard.
If the power supply cord is damaged, call a certified electrician of the manufacturer or other maintenance department to replace it.
Important Points of Safety
3
Warning
Warning
Attention points for use
DON'T lay any burning facilities in place where winds produced by the machine can reach. Incomplete combustion of burning facility may be caused otherwise.
Ensure ventilation of the room if the machine is used with burning facilities. Deficient ventilation can cause oxygen shortage.
DON'T clean the machine with water. Electric shock may occur otherwise.
Check whether installation bench of the machine is damaged after a long period of use. Machine on damaged bench may fall down and cause human injury or other damage.
DON'T operate switch with wet hand. Electric shock may occur otherwise.
Stop operation and shut down manual power switch before cleaning and maintenance.
The machine CANNOT be used for the purpose of preserving food, animals, plants, precision instruments and artwork etc., which may be destroyed otherwise.
The power supply MUST be of rated voltage and connected with special electrical supply circuit.
DON'T replace fuse with material other than fuse of proper capacity. Replacing fuse with metal wire or copper etc. can cause fire hazard or other faults.
DON'T put flammable spray articles nearby or spray them to the machine. Fire hazard may occur otherwise.
In place where winds produced by the machine can reach, don't lay any animals or plants which may be hurt otherwise.
Important Points of Safety
4
Attention
Check whether earthing wire is broken or falls off. Check whether air filter was omitted. Switch on power supply of the outdoor unit 12 hours in priority to entrust.
During heating program, the machine adopts heat pump mode to release heat indoors with that absorbed from outdoors. Therefore its heating ability reduces when outdoor temperature descends.
Heat ability
During heat operation, if the outdoor unit is adhered with frosts, the machine will automatically turn to frost­removing operation which lasts about 2~10 minutes. During frost-removing operation, fan of indoor unit runs at low speed or stops while outdoor unit stops.
To protect the machine, for immediate restart after a stop, the compressor does not run until after a interval of 3 minutes.
All operations will stop when there is a power failure during the machineís running. Running indicator on remote controller flashes when the system is reenergized after power failure. Before restart, press on/off button of the remote controller. Note: If you have set power down memory function, the machine will get back to the status before power failure when it is reenergized.
Confirmation before running
Removal of frost in heat operation
3 minutes protection
Power failure
Protection setting (High pressure switch)
If something abnormal happens with the machine, the protection setting will act to stop running automatically. Press ì checkî button on the remote controller to see failure code shown. Protection setting acts in the following case.
During cool operation
Inlet or outlet of outdoor unit is blocked. Strong wind continuously blows into the outlet of outdoor unit.
During heat operation
Large amount of dust adheres on air filter screen of indoor unit. Outlet of indoor unit is blocked.
Air filer of cassette type
Air filter screen must be installed near the inlet when installing air-conditioner of flush type. After trial run of the machine, verify the following items: Position where air filter screen is installed How to disassemble the filter How to clean the filter
Operation of fans of units that stop
To protect units that stop during running of other indoor unit, run their fans for 2~8 minutes at an interval of 30 or 60 minutes.
Note: Confirm failure code shown on the remote controller, shut down power switch and find out reasons after protection setting works. (check method as seen from " check" on page 21). Continuous operation without solving problems can cause faults of the machine. Ensure air filter is installed. Without the filter, dust may accumulate on heat exchanger and cause water leakage. Each indoor unit can run individually or many indoor unit run in meantime. However, heat and cool operation cannot be run at the same time.
Operation Features