Hach-Lange BUHLER 1027, BUHLER 1029, BUHLER 2000 User Manual

Page 1
DOC013.52.90269
1027 1029 2000
BÜHLER 1027, 1029, 2000
Portable Sampler
Short Manual
08/2011, Edition 3A
© HACH-LANGE GmbH, 2010, 2011. All ri ghts reserved. Printed in Germany
Page 2
Page 3
Table of Contents
Section 1 Specifications ........................................................................................................................5
1.1 Dimensions ........................................................................................................................................6
Section 2 General Information...............................................................................................................7
2.1 Safety information...............................................................................................................................7
2.1.1 Use of hazard information..........................................................................................................7
2.1.2 Precautionary labels ..................................................................................................................7
2.2 General Information............................................................................................................................8
2.2.1 Areas of application ...................................................................................................................8
2.2.2 Functional description................................................................................................................8
2.3 Product contents.................................................................................................................................8
Section 3 Installation............................................................................................................................ 11
3.1 Mechanical installation......................................................................................................................12
3.1.1 Required tools..........................................................................................................................12
3.1.2 Installation location (1027).......................................................................................................13
3.1.3 Position (1029 and 2000).........................................................................................................14
3.1.4 Attach the sampler compartment to the bottle compartment (1029).......................................15
3.2 Electrical connections.......................................................................................................................15
3.2.1 Electrical installation ................................................................................................................16
3.2.1.1 Prepare the electrical installation....................................................................................16
3.2.1.2 Wiring diagram................................................................................................................17
3.2.2 Installation of the optional bottle compartment with active cooling (1029/2000)...................... 18
3.3 Commission of the equipment.......................................................................................................... 20
3.3.1 Tube connection......................................................................................................................20
3.3.2 Set the individual sample volumes...........................................................................................21
3.3.2.1 Plastic dosing vessel.......................................................................................................21
3.3.2.2 Glass dosing vessel........................................................................................................23
3.3.2.3 Dosing vessel for flow-proportional sampling .................................................................25
3.3.3 Remove the top part of the housing (1029).............................................................................27
3.3.4 Remove the top part of the housing (2000).............................................................................28
3.3.5 Prepare the bottle compartments.............................................................................................28
3.3.6 Attach the top part of the housing............................................................................................29
3.3.7 Connect the equipment to the mains.......................................................................................30
3.3.8 Switch on the device................................................................................................................32
3.3.9 Adjust the cooling settings for the optional bottle compartment with active cooling (1029 and
2000)...........................................................................................................................................33
Section 4 Operation..............................................................................................................................35
4.1 Control unit operation .......................................................................................................................35
4.1.1 Password.................................................................................................................................35
4.1.2 Programming ...........................................................................................................................35
4.1.3 Keyboard layout/function .........................................................................................................35
4.2 Normal operation.............................................................................................................................. 37
4.2.1 Replace the sample bottles......................................................................................................37
Page 4
Section 5 Maintenance and cleaning...................................................................................................39
5.1 Maintenance tasks ............................................................................................................................39
5.2 Cleaning............................................................................................................................................39
5.2.1 Clean the housing and distribution unit (1029–2000)...............................................................39
5.2.2 Clean the dosing vessel...........................................................................................................41
5.3 Troubleshooting ................................................................................................................................43
5.3.1 Change the fuse.......................................................................................................................43
5.4 Instrument decommissioning and storage.........................................................................................45
Section 6 Replacement parts and accessories ..................................................................................47
6.1 Spare parts........................................................................................................................................47
6.2 Accessories.......................................................................................................................................50
Section 7 Warranty and Liability..........................................................................................................53
Section 8 Contact information ............................................................................................................55
Page 5

Section 1 Specifications

These are subject to change without notice.
BÜHLER 1027 BÜHLER 1029 BÜHLER 2000 BÜHLER 1029 BÜHLER 2000
Without active cooling With active cooling Electrics Power supply, sampler compartment
With integrated battery 12 V (DC) 12 V (DC) With integrated power
pack With optional power pack 110–230 V/50–60 Hz.
Power supply, bottle compartment
With integrated power pack
Rating 16 A Power consumption approx. 30 VA approx. 50 VA Environment Medium temperature 0to40°C [32to104°F] Ambient temperature 0to50°C [32to122°F] 0to43°C [32to110°F] Delivery height < 6m [20ft], optional < 8m [26ft] General specifications Coolant R134a Maintenance requirements Maintenance-free Weight
110–230 V/
50–60 Hz.
12 V (DC)
110V/60Hz 230 V/50 Hz
or (optional) or (optional)
Top part approx. 6.6 kg approx. 10 kg approx. 14.3 kg approx. 1 0 kg approx. 14.3 kg Bottle compartment approx. 11 kg approx. 25 kg Complete approx. 22 kg approx. 25 kg approx. 35 kg approx. 40 kg
Dimensions (W × H × D)
Top part
Bottle compartment
Complete
With cap opened (55°)
Certification Certification CE, sampling in accordance with ISO 5667-2/3-10
475 × 362 × 222
[18.7×14.3×8.7]
445 × 442 × 222
[17.5×17.4×8.7]
510 × 534 × 430
[20 × 21 × 16.9]
510 × 942 × 430
[20 × 37 × 16.9]
510 × 390 × 468
[20×15.4×18.4]
510 × 787 × 468
[20 × 31 × 18.4]
510 × 970 × 468
[20×38.2×18.4]
445 × 442 × 222
[17.5×17.4×8.7]
550 × 775 × 468
[21.7 × 30.5 × 18.4]
510 × 970 × 468
[20×38.2×18.4]
510 × 390 × 468
[20×15.4×18.4]
550 × 1028 × 468
[21.7×40.5×18.4]
510 × 1210 × 468 [20 × 47.6 × 18.4]
Page 6
Specifications
5
jkl6mno4ghi
8
tuv wxyz97pqrs
2
abc3def
1
0
5
jkl6mno4ghi
8
tuv wxyz97pqrs
2
abc3def
1
0
H
T
H
T
H
H
B
B
B
H
T
siehe Tabelle Technische Daten
B×H×T:
55°
W
H
D
W
D
H
W
H
D
H
H
W × H × D:, see the specifications table

1.1 Dimensions

1027
1029
2000
Figure 1 Dimensions
Page 7

Section 2 General Information

2.1 Safety information

Please read this entire manual before unpacking, setting up, or operating this equipment. Pay attention to all danger and caution statements. Failure to do so may result in personal injury or damage to the instrument.
To ensure that the protection provided by this equipment is not imp aired, do not use or install this equipment in any manner other than that specified in this manual.

2.1.1 Use of hazard information

DANGER
Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a potentially or imminently hazardous situation that, if not avoided, could result in death or serious injury.
CAUTION Indicates a potentially or imminently hazardous situation that could result in minor or moderate injury.
Important note: Information that requires special emphasis.
Note: Information that supplements points in the main text.

2.1.2 Precautionary labels

Read all labels and tags attached to the instrument. Failure to do so may resu lt in personal injury or damage to the instrument. A symbol, if noted on the instrument, will be included with a danger or caution statement in the manual.
This symbol, if noted on the instrument, references the user manual for operation and/or safety information.
This symbol, when noted on a product enclosure or barrier, indicates that a risk of electrical shock and/or electrocution exists.
This symbol may appear on the product and indicates the need for protective eye wear.
This symbol may appear on the product and identifies the connection point for the protective ground.
Page 8
General Information
INPUT-Stecker
1,7 m
[5.6 ft]
INPUT plug
When this symbol appears on the product, it identifies the location of a fuse or a current limiter.
Electrical equipment marked with this symbol may not be disposed of in European domestic or public disposal systems after 12 August 2005. In conformity with European local and national regulations (EU Directive 2002/96/EC), European electrical equipment users must now return old or end-of-life equipment to the manufacturer for disposal at no charge to the user.
Note: For return for recycling, please contact the equipment manufacturer or supplier for instructions on how to return end-of-life equipment, manufacturer-supplied electrical accessories, and all auxiliary items for proper disposal.

2.2 General Information

2.2.1 Areas of application

The equipment is used for sampling aqueous liquids with a temperature of 0 °C to 50 °C (refer to Section 1 Specifications, page 5).

2.2.2 Functional description

The equipment provides temporary storage for liquids of a specified volume so that they can be analyzed.

2.3 Product contents

The equipment is supplied with a tube and brief operating instructions. Depending on the model, the equipment is also supplied with a plug (1027/active cooled bottle compartment), tension belt (1029) or an optional charger (1029/2000). If you require further information, you can order the operating instructions (refer to
Section 6 Replacement part s and accessories, page 47) from the manufacturer or you can
download them from the Internet.
Figure 2 Scope of delivery (1027)
Page 9
General Information
Figure 3 Scope of delivery (1029)
Figure 4 Scope of delivery (2000)
Page 10
General Information
10
Page 11

Section 3 Installation

DANGER
Only qualified experts should conduct the tasks described in this section.
DANGER Select an appropriate installation location for the instrument.
Plan out the mechanical mount·before positioning poles or drilling holes. Make sure the mount has a sufficient bearing capacity. The dowels must be selected and authorized according to the condition of the wall. The manufacturer shall accept no liability if the instrument is installed incorrectly.
Plan how to lay cables and tubes and their path in advance. Lay the tubes, data cables and power cables without any bends and so they do not pose a tripping risk.
Do not connect the electrical supply to the mains if the equipment has not been wired and fused correctly.
Sufficiently protect the electrical power supply against short circuits.
For the external power supply, always connect a residual-current circuit breaker·(trip current max.: 30 mA) between the mains and the system.
If the equipment is to be installed outdoors, switch the overload prot ection between mains and system.
Products intended by the manufacturer for outdoor use offer a higher level of protection against the penetration of liquids and dust. If these products are connected to a mains outlet with a cable and plug·rather than a permanently connected cable, the plug and outlet are much more susceptible to liquid and dust penetration. The operator must sufficiently protect the plug and outlet against liquid and dust penetration in accordance with local safety regulations. If the instrument is to be used outdoors, it must be connected to a suitable outlet with a protection type of at least IP44 (splash protectio n).
11
Page 12
Installation

3.1 Mechanical installation

DANGER Select an appropriate installation location for the instrument.
Plan out the mechanical mount·before positioning poles or drilling holes. Make sure the mount has a sufficient bearing capacity. The dowels must be selected and authorized according to the condition of the wall. The manufacturer shall accept no liability if the instrument is installed incorrectly.
Plan how to lay cables and tubes and their path in advance. Lay the tubes, data cables and power cables without any bends and so they do not pose a tripping risk.
Note: For information on installation with optional accessories, refer to the relevant installation
instructions.

3.1.1 Required tools

Figure 5 Required tools (1027)
Figure 6 Required tools (1029 and 2000)
12
Page 13

3.1.2 Installation location (1027)

210 mm [8.30 in]
210 mm
[8.3 in]
Select suitable fastening materials (e.g. 6 × 40 mm screws and corresponding dowels) and read all the safety information about installation and mechanical assembly.
Installation
Figure 7 Select installation location (1027)
Figure 8 Attach the equipm ent (1027)
13
Page 14
Installation
<5°
<5°
<5°
<5°
<5°
<5°
<5°
<5°

3.1.3 Position (1029 and 2000)

Figure 9 Select the position (1029 and 2000)
14
Figure 10 Position the equipment (1029 and 2000)
Page 15

3.1.4 Attach the sampler compartment to the bottle compartment (1029)

1
2
Installation
Figure 11 Attach the sampler compartment to the bottle compartment (1029)

3.2 Electrical connections

DANGER
Only qualified experts should conduct the tasks described in this section.
DANGER Do not connect the electrical supply to the mains if the equipment has not been wired and fused correctly.
Sufficiently protect the electrical power supply against short circuits.
For the external power supply, always connect a residual-current circuit breaker·(trip current max.: 30 mA) between the mains and the system.
If the equipment is to be installed outdoors, switch the overload prot ection between mains and system.
If the mains plug·of the power supply cable·is removed, a suitable double-pole one-way switch must be installed immediately next to the display unit·with clear labeling for the power supply.
Products intended by the manufacturer for outdoor use offer a higher level of protection against the penetration of liquids and dust. If these products are connected to a mains socket with a cable and plug·rather than a permanently
15
Page 16
Installation
4
2
3
1
connected cable, the plug and socket are much more susceptible to liquid and dust penetration. The operator must sufficiently protect the plug and outlet against liquid and dust penetration in accordance with local safety regulations. If the instrument is to be used outdoors, it must be connected to a suitable outlet with a protection type of at least IP44 (splash protection).

3.2.1 Electrical installation

3.2.1.1 Prepare the electrical installation
In battery mode In mains power mode
1027 No preparation required
1029 No preparation required
2000 No preparation required Connect the Y cable as shown in Figure12.
Connect the optional charger to the charge socket on the left-hand
side.
Figure 12 Connect the Y cable (2000)
To connect the equipment to the mains, see Figure 36 Model 2000 with Y cable and
charger on page 31.
16
Page 17
3.2.1.2 Wiring diagram
54321
4–20 mA
Event
Q
pH
1
2
3
4
5
optionales Datenkabel
BM69644 (10 m)
Optional signal cable
For example:
Please note:
The assignment of the connections in the illustration below
The cable color of the label on the cable
Installation
Figure 13 Connection plan for the optional signal cable (BM69644)
17
Page 18
Installation
12 V115 V/60 Hz 230 V/50 Hz
230 V/50 Hz 115 V/60 Hz
12 V
1
6
11
1
5
20

3.2.2 Installation of the optional bottle compartment with active cooling (1029/2000)

Figure 14 Select the cable for the optional bottle compartment with active cooling (1029/2000)
18
Figure 15 Connect the optional bottle compartment with active cooling
Page 19
Installation
1
6
11
1
5
20
Important note: Blocked air outlets and liquids in the cooling machine or inside the optional bottle compartment with active cooling can damage the equipment. Make sure that the air outlets are always open and that no liquid is able to enter the air outlets.
Figure 16 Sample distributor plate and air outlets on the optional bottle compartment with active cooling
Note: The housing base on the bottle compartment features numbers so that the individual bottles can be assigned with a number.
19
Page 20
Installation

3.3 Commission of the equipment

3.3.1 Tube connection

Figure 17 Connect the sample tube connection
20
Page 21
Positioning of the tubes according to the following installation diagram.
5
jkl6mno4ghi
8
tuv wxyz97pqrs
2
abc3def
1
0
ExH2S
6500 mm
[21.3 ft]
1000 mm
[40 in]
30 000 mm
[100 ft]
0–40 °C [32–104 °F]
0–40 °C [32–104 °F]
>50µs
1
2
Installation
Figure 18 Installation diagram

3.3.2 Set the individual sample volumes

3.3.2.1 Plastic dosing vessel
Figure 19 Unlock the bayonet cap on the plastic dosing vesse l
21
Page 22
Installation
= 150 mL
V-Probe [mL]
Figure 20 Remove the plastic dosing vessel
22
Figure 21 Cut the dosing tube to set the sample volume
Page 23
Installation
1
2
3.3.2.2 Glass dosing vessel
Figure 22 Assemble the plastic dosing vessel
Figure 23 Loosen the union nut on the glass dosing vessel
23
Page 24
Installation
V-Probe [mL]
= 150 mL= 150 mL
Figure 24 Remove the glass dosing vessel
24
Figure 25 Cut the dosing tube to set the sample volume
Page 25
Installation
100 mL = 100 mL
Figure 26 Assemble the glass dosing vessel
3.3.2.3 Dosing vessel for flow-proportional sampling
Figure 27 Calibrate the flow-prop ortional dosing vessel via the service menu
25
Page 26
Installation
DP = 0 [hPa, bar]
Figure 28 The flow-proportional dosing vessel can only be used,
if there is NO counter pressure
26
Page 27

3.3.3 Remove the top part of the housing (1029)

3
4
20
15
11
6
1
2
1
Installation
Figure 29 Remove the top part of the housing (1029)
27
Page 28
Installation
2
1
20
15
11
6
1
21 3
20
15
11
6
1
20
15
11
6
1
20
15
11
6
1

3.3.4 Remove the top part of the housing (2000)

Figure 30 Remove the top part of the housing (2000)

3.3.5 Prepare the bottle compartments

Figure 31 Place the empty bottles into the bottle compartment
Note: The sample distributor plate works correctly in all four of its potential positions. Note: The housing base of the bottle compartment features numbers so that the individual bottles
can be assigned with a number.
28
Page 29

3.3.6 Attach the top part of the housing

3
2
1
20
15
11
6
1
20
15
11
6
1
1
2
20
15
11
6
1
20
15
11
6
1
Figure 32 Attach the top part of the housing (1029)
Installation
Figure 33 Attach the top part of the housing (2000)
29
Page 30
Installation
V?
Hz ?
VA ?

3.3.7 Connect the equipment to the mains

Make sure that:
The equipment has been fully prepared for commissioning
The data on the type plate corresponds to the data relating to the mains power supply
(this applies to 1027 as well as to 1029 and 2000 in conne ction with the charger and Y plug BM69742
The correct plug has been attached or the direct wire has been implemented correctly
The equipment can be put into operation without any risks
DANGER Make sure that the power supply, cable (also refer to Figure 14, page 18) and equipment are suitable for use with each other.
30
Figure 34 Rating label
Page 31
1,7 m
[5.6 ft]
D
UK
CH
Figure 35 Possible connection configurations (1027)
Installation
Figure 36 Model 2000 with Y cable and charger
31
Page 32
Installation
230 V/50 Hz 115 V/60 Hz
12 V
1
6
11
15
2
0
I/OI/OI/O
Figure 37 Potential connection variations (optional bottle compartment with active cooling)

3.3.8 Switch on the device

Figure 38 Switch on the device
32
Page 33
Installation
1
6
11
15
20

3.3.9 Adjust the cooling settings for the optional bottle compartment with active cooling (1029 and 2000)

The manufacturer recommends a settings range of +4 to +15 °C.
Figure 39 Adjust the cooling settings for the optional bottle compartment with active cooling
33
Page 34
Installation
34
Page 35

Section 4 Operation

4.1 Control unit operation

All the equipment functions are software-controlled.

4.1.1 Password

Password to program sampler and to change settings is:

4.1.2 Programming

The menu structure resembles the directory structure of a computer hard drive and is divided into main menus and sub menus.

4.1.3 Keyboard layout/function

The equipment can be programmed by the operator.
6299
Figure 40 Control panel
The key functions are configured as follows to enable highly intuitive operation:
Table 1 Key functions
Display help text (in the case of selection fields, the cursor must be placed on the left-hand side)
Move from one menu item to the next menu selection Arrow keys
Select the menu required Enter key
Move within a menu Arrow keys
Arrow key
35
Page 36
Operation
Table 1 Key functions
Select from within a menu Arrow keys
Confirm the selection (automatically marked with a )
Enter/change values Arrow keys
Confirm the entered values Enter key
Return to the next superordinate menu level Back key
Enter values
RESET (restore factory settings) Press and hold Back for at least 10 seconds
Enter key
Numeric keypad
Back key
Example: A setting needs to be changed.
1. Press Enter.
The cursor then flashes.
2. Use the arrow keys to move the cursor until it is in the required position.
3. Press Enter.
The selection is now confirmed and the program can be started.
36
Page 37
Figure 41 Start the program
21 43
20
15
11
6
1
20
15
11
6
1
20
15
11
6
1
20
15
11
6
1
Depending on the program range,
Operation
an activity is started or
the next menu item is automatically selected.
Note: The general rule: If you press Back, – the activity is cancelled or – the navigation takes one step back in the menu.

4.2 Normal operation

4.2.1 Replace the sample bottles

Figure 42 Replace full bottles
37
Page 38
Operation
38
Page 39

Section 5 Maintenance and cleaning

DANGER
Only qualified experts should conduct the tasks described in this section.
WARNING Please observe the following points for the use of chemicals and/or waste water:
Wear protective clothing: – Laboratory coat – Protective eyewear – Rubber gloves

5.1 Maintenance tasks

The equipment is maintenance-free, therefore the operator do es not need to carr y out any maintenance work.

5.2 Cleaning

5.2.1 Clean the housing and distribution unit (1029–2000)

WARNING! Manual rotation of the distribution unit can damage the dr ive. Never rotate the distribution unit manually.
Clean the interior and exterior of the housing with a damp, lint-free cloth. Add commercial household cleaner to the cleaning water as required.
1. Clean the exterior of the housing.
2. Remove the top part as shown in the illustrationsFigure 29, Page 27 and Figure 30,
Page 28.
3. Loosen the central nut and remove the distribution vat.
39
Page 40
Maintenance and cleaning
21
21
Figure 43 Remove the distribution vat (1029 and 2000)
4. Clean the distribution vat.
5. Attach the distribution vat aga in an d in do in g s o make s ure th at th e gu ide pin is
positioned in the bore hole.
40
Figure 44 Assemble the distribution vat (1029 and 2000 )
6. Tighten the central nut by hand again.
Page 41
Maintenance and cleaning
20
15
11
6
1
1
2
7. Clean the sample distributor plate on the bottle compartment.
Figure 45 Clean the sample distributor plate on the bottle compartment
8. Position the top part back on the bottle compartment as shown in the illustrations
Figure 32, Page 29 and Figure 33, Page 29.

5.2.2 Clean the dosing vessel

Figure 46 Release the dosing vessel
41
Page 42
Maintenance and cleaning
Figure 47 Remove the dosing vessel
42
Figure 48 Clean the dosing vessel
Page 43
Maintenance and cleaning
1
2

5.3 Troubleshooting

If the equipment does not work as required, check the fuse and replace if necessary.

5.3.1 Change the fuse

Open the fuse holder as shown in Figure 50 and replace the defective fuse.
Figure 49 Insert the dosing vessel
43
Page 44
Maintenance and cleaning
1
6
11
1
5
20
Figure 50 Position of the fuse in the portable sampler
Figure 51 Position of the fuse in the optional bottle compartment with active cooling
If the error is not rectified, please contact the customer service of the manufacturer (refer to Contact information, page 55).
44
Page 45

5.4 Instrument decommissioning and storage

1. Remove all liquids and, if necessary, solid matter from the infeed and outfeed lines
and bottle compartments and clean as required.
2. Close all active programs.
3. Switch the equipmen t off.
Maintenance and cleaning
45
Page 46
Maintenance and cleaning
46
Page 47

Section 6 Replacement parts and accessories

6.1 Spare parts

Description Cat. no.
Short Manual 1027, 1029, 2000 (xx = language number) DOC013.xx.90269 Operating instructions 1027 (xx = language number) DOC023.xx.90152 Operating instructions 1029 and 2000 (xx = language number) DOC023.xx.90153 Replacement bottle, glass, 1 L BM30030 Cap for 1 L gl ass bottle BM60533 Replacement bottle, glass, 20 L BM30045 Replacement bottle, PE, 1 L BM60486 Cap for 1 L PE bottle BM60488 Replacement bottle, PE, 25 L (with cap) BM60046 Replacement bottle, PE, 5 L (with cap) BM60038 Replacement bottle, PE, 13 L (with cap) BM60045 Replacement battery 1029 BM10012 Replacement battery 2000 BM900116
47
Page 48
BM80070
BM69452
BM80044
350 mL
BM69301
12×2
BM69302
4 × 1,5
BM900715
BM900627
Kunststoff - Dosiereinheit
Plastic dosing vessel
Replacement parts and accessories
Figure 52 Plastic dosing vessel
48
Page 49
BM69402
BM30004 350 mL
BM69301
12×2
BM69302
4 × 1,5
Glas - Dosiereinheit (350 mL)
BM900743
BM80070
BM900627
Glass dosing vessel (350 ml)
Replacement parts and accessories
Figure 53 Glass dosing vessel (350 ml)
49
Page 50
Replacement parts and accessories

6.2 Accessories

Description Cat. no.
Y cable, power supply BM69742 Charger IP20 for 1029 and 2000 BM900026 Charger IP65 for 1029 and 2000 BM900033 Signal cable, 10 m (32.8 ft.) BM69644 RS232 serial data cable BM900021 PC software READ DATA BM200004 Tube connection with screw connection BM900300 Battery for bottle compartment with active cooli ng (90Ah) BM10211 Sample transportation box (without bottles) BM900634 Replacement cooling battery BM60251 Transportation trolley BM900802
Figure 54 Charger IP20
Figure 55 Charger IP65
50
Page 51
Replacement parts and accessories
Figure 56 Transportation trolley (1029/2000)
51
Page 52
Replacement parts and accessories
52
Page 53

Section 7 Warranty and Liability

The manufacturer warrants that the product supplied is free of mater ial and manufacturing defects and undertakes the obligation to repair or replace any defective parts at zero cost.
The warranty period for instruments is 24 months. If a service contract is taken out within 6 months of purchase, the warranty period is extended to 60 months.
With the exclusion of further claims, the supplier is liable for defects including the lack of assured properties as follows: All those parts that, within the warranty period calculated from the day of the transfer of risk, can be demonstrated to have become unusable or that can only be used with significant limitations due to a situation present prior to the transfer of risk, in particular due to incorrect design, poor materials or inadequate finish will be improved or replaced, at the supplier's discretion. The identification of such defects must be reported to the supplier in writing without delay, but no later than 7 days after the identification of the fault. If the customer fails to notify the supplier, the product is considered approved despite the defect. Further liability for any direct or indirect damages is not accepted.
If instrument-specific maintenance and servicing work defined by the supplier is to be performed within the warranty period by the customer (maintenance) or by the supplier (servicing) and these requirements are not carried out, claims for damages due to the failure to comply with the requirements are rendered void.
Any further claims, in particular claims for consequential damages, cannot be made. Consumables and damage caused by improper hand ling, unsafe assembly or by incorrect
use are excluded from this provision. Process instruments of the manufacturer are of proven reliability in many applications and
are therefore often used in automatic control loops to provide the most economical operation possible for the related process.
To avoid or limit consequential damage, it is therefore recommended to desig n the control loop such that a malfunction in an instrument results in an automatic change over to the backup control system, which is the most secure operating condition for the environment and for the process.
53
Page 54
Warranty and Liability
54
Page 55

Section 8 Contact information

55
Page 56
Contact information
56
Loading...