Hach PHOSPHAX sc LR, PHOSPHAX indoor sc LR User Manual

DOC023.53.90627
PHOSPHAX sc LR, PHOSPHAX indoor sc LR
User Manual
08/2018, Edition 1

Table of Contents

Section 1 Specifications.................................................................................................................... 3
1.1 Sample requirements................................................................................................................... 4
1.2 Interferences................................................................................................................................ 4
Section 2 General information......................................................................................................... 5
2.1.1 Use of hazard information................................................................................................... 5
2.1.2 Precautionary labels............................................................................................................ 5
2.1.3 Chemical and biological safety............................................................................................ 6
2.1.4 Certification......................................................................................................................... 6
2.2.1 Status indicator light............................................................................................................ 9
Section 3 Installation........................................................................................................................ 11
3.2.1 Attach the instrument to a wall.......................................................................................... 11
3.2.2 Open the enclosure........................................................................................................... 13
3.2.3 Remove the transport lock................................................................................................ 14
3.4.1 Sample line guidelines...................................................................................................... 15
3.4.2 Drain line guidelines.......................................................................................................... 16
3.4.3 Tubing considerations....................................................................................................... 16
3.5.1 Plumbing one outdoor analyzer.........................................................................................18
3.5.2 Plumbing two outdoor analyzers....................................................................................... 19
3.5.3 Plumbing one outdoor analyzer with continuous sample feed.......................................... 21
3.5.4 Plumbing two outdoor analyzers with continuous sample feed......................................... 22
3.5.5 Plumbing one indoor analyzer........................................................................................... 24
3.5.6 Plumbing two indoor analyzers......................................................................................... 25
3.5.7 Plumbing one indoor analyzer with continuous sample feed............................................ 27
3.5.8 Plumbing two indoor analyzers with continuous sample feed........................................... 27
3.5.9 Two-parameter configuration............................................................................................ 29
3.8.1 Electrostatic discharge (ESD) considerations................................................................... 34
3.8.2 Connect the optional heated drain.................................................................................... 34
3.8.3 Supply power to the analyzer............................................................................................ 35
Section 4 Operation.......................................................................................................................... 39
1
Table of Contents
Section 5 Maintenance..................................................................................................................... 45
5.1 Maintenance schedule............................................................................................................... 45
5.2 Examine for damage.................................................................................................................. 45
5.3 Examine the tubing and fittings.................................................................................................. 45
5.4 Clean the instrument.................................................................................................................. 46
5.5 Clean spills................................................................................................................................. 46
5.6 Replace the reagents................................................................................................................. 46
5.7 Replace the air filter pads.......................................................................................................... 46
5.8 Replace the pump head for air pump (piston pump).................................................................. 48
5.9 Do a leakage test....................................................................................................................... 49
5.10 Replace the fuses.................................................................................................................... 50
5.11 Do a validation check (analytical quality assurance)................................................................50
5.11.1 Validation with standard solution..................................................................................... 50
5.11.2 Validation with applicable laboratory measurement (cuvette test).................................. 51
5.12 Put the analyzer in shutdown mode......................................................................................... 53
5.12.1 Prepare the analyzer for storage..................................................................................... 53
Section 6 Troubleshooting..............................................................................................................55
6.1 Troubleshoot the controller........................................................................................................ 55
6.2 Troubleshooting the analyzer..................................................................................................... 55
Section 7 Replacement parts and accessories.......................................................................... 59
2

Section 1 Specifications

Specifications are subject to change without notice.
Specification Details
Dimensions (W x H x D) PHOSPHAX sc LR: 540 × 720 × 390 mm (21.25 × 28.35 ×
15.35 in.) PHOSPHAX indoor sc LR: 540 × 720 × 370 mm (21.25 ×
28.35 × 14.5 in.)
Enclosure Enclosure rating: PHOSPHAX sc LR, IP55; PHOSPHAX
indoor sc LR, IP54 Enclosure material: ASA/PC UV-resistant
Weight PHOSPHAX sc LR: Approximately 31 kg without chemicals
PHOSPHAX indoor sc LR: Approximately 29 kg without chemicals
Measuring method Two-beam photometer (yellow method)
Measuring range 0.015 to 2 mg/L PO4–P
Detection limit 0.015 mg/L with standard
Measuring accuracy (with standard solution) 2% of the measured value + 0.015 mg/L
Repeatability (with standard solution) 0.7% of the measured value + 0.005 mg/L
1
Response time (90 %) 10 minutes
Adjustable measuring interval 10 to 120 minutes
Power supply With power cable, connected to a SC1000 controller or
SC200 with power box. Analyzer and drain tubing: 115 V or 230 V versions
Data transmission SC standard
Electrical power consumption 500 VA
Electrical fuse protection Supplied by SC1000 controller or SC200 controller with
power box. Maximum of two analyzers for each SC Controller.
Outputs Relay, analog outputs, network interface through
SC1000/SC200 controller2.
Operating temperature PHOSPHAX sc LR: –20 to 40 °C (–4 to 104 °F); 95% relative
humidity, non-condensing, non-corrosive PHOSPHAX indoor sc LR: 5 to 40 °C (41 to 104 °F); 95%
relative humidity, non-condensing, non-corrosive
Storage temperature –20 to 60 °C (–4 to 140 °F); 95% relative humidity, non-
condensing
Data and power cable lengths 2 m (80 in.) from edge of enclosure
Certifications CE marked. Listed to UL and CSA safety standards by TÜV.
Warranty 1 year (EU: 2 years)
1
At room temperature. ± 4% for values > 1 mg/L PO4–P along the full temperature range.
2
Refer to the controller documentation for more information about the relay, analog and digital outputs.
3
Specifications

1.1 Sample requirements

The water from the sample source(s) must agree with the specifications that follow.
Specification Description
Sample flow rate 1.0 to 20.0 L/h
Sample pressure With continuous sample preparation: –30 mbar to +50 mbar at overflow vessel.
Sample temperature 4 to 45 °C (39 to 113 °F)
Sample quality Ultra filtrated or comparable
Sample pH 5 to 9

1.2 Interferences

Table 1 shows that the ions were individually examined to the given concentrations and
do not cause interference. No cumulative effects or influences of other ions were found. Verify the measurement results with sample dilutions or standard additions.
Table 1 Interfering substances
Interfering substance Interference level
Cl
5000 mg/L
4

Section 2 General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential damages resulting from any defect or omission in this manual. The manufacturer reserves the right to make changes in this manual and the products it describes at any time, without notice or obligation. Revised editions are found on the manufacturer’s website.

2.1 Safety information

The manufacturer is not responsible for any damages due to misapplication or misuse of this product including, without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent permitted under applicable law. The user is solely responsible to identify critical application risks and install appropriate mechanisms to protect processes during a possible equipment malfunction.
Please read this entire manual before unpacking, setting up or operating this equipment. Pay attention to all danger and caution statements. Failure to do so could result in serious injury to the operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any manner other than that specified in this manual.

2.1.1 Use of hazard information

Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation that may result in minor or moderate injury.
N O T I C E
D A N G E R
W A R N I N G
C A U T I O N
Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special emphasis.

2.1.2 Precautionary labels

Read all labels and tags attached to the instrument. Personal injury or damage to the instrument could occur if not observed. A symbol on the instrument is referenced in the manual with a precautionary statement.
This symbol, if noted on the instrument, references the instruction manual for operation and/or safety information.
Electrical equipment marked with this symbol may not be disposed of in European domestic or public disposal systems. Return old or end-of-life equipment to the manufacturer for disposal at no charge to the user.
This symbol indicates that a risk of electrical shock and/or electrocution exists.
N O T I C E
5
General information
This symbol indicates the need for protective eye wear.
This symbol indicates that the marked item requires a protective earth connection. If the instrument is not supplied with a ground plug on a cord, make the protective earth connection to the protective conductor terminal.
This symbol, when noted on the product, identifies the location of a fuse or current limiting device.
This symbol identifies a risk of chemical harm and indicates that only individuals qualified and trained to work with chemicals should handle chemicals or perform maintenance on chemical delivery systems associated with the equipment.
This symbol indicates that the marked item can be hot and should not be touched without care.
This symbol indicates the presence of devices sensitive to Electro-static Discharge (ESD) and indicates that care must be taken to prevent damage with the equipment.
This symbol indicates that the object is heavy.
This symbol indicates that the marked item should not be touched.

2.1.3 Chemical and biological safety

Chemical or biological hazards. If this instrument is used to monitor a treatment process and/or chemical feed system for which there are regulatory limits and monitoring requirements related to public health, public safety, food or beverage manufacture or processing, it is the responsibility of the user of this instrument to know and abide by any applicable regulation and to have sufficient and appropriate mechanisms in place for compliance with applicable regulations in the event of malfunction of the instrument.

2.1.4 Certification

This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Canadian Radio Interference-Causing Equipment Regulation, IECS-003, Class A: Supporting test records reside with the manufacturer. This Class A digital apparatus meets all requirements of the Canadian Interference-
Causing Equipment Regulations. Cet appareil numérique de classe A répond à toutes les exigences de la réglementation
canadienne sur les équipements provoquant des interférences.
FCC Part 15, Class "A" Limits
Supporting test records reside with the manufacturer. The device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
D A N G E R
C A U T I O N
1. The equipment may not cause harmful interference.
2. The equipment must accept any interference received, including interference that
may cause undesired operation.
6
Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their expense. The following techniques can be used to reduce interference problems:
1. Disconnect the equipment from its power source to verify that it is or is not the source of the interference.
2. If the equipment is connected to the same outlet as the device experiencing interference, connect the equipment to a different outlet.
3. Move the equipment away from the device receiving the interference.
4. Reposition the receiving antenna for the device receiving the interference.
5. Try combinations of the above.

2.2 Product overview

General information
The PHOSPHAX sc LR is a one-channel analyzer that measures ortho-phosphate ions
3—
(PO
) in waste water and surface water. The analyzer does not measure diphosphates
4
or polyphosphates. The measuring principle is based on the Vanadat-Molybdat method, also known as the Yellow method.
The analyzer is used with an SC Controller. The measured value shows on the controller display as PO4–P (default) or PO
3—
.
4
There are two analyzer models available:
PHOSPHAX sc LR: weather-resistant enclosure for outdoor installation
PHOSPHAX indoor sc LR: for indoor installation
The reagents and standards necessary for the chemical analysis are internally installed in the analyzer enclosure. The analyzer uses pumps, valves and syringes to move the sample and reagents to the measuring cell on the analytics panel. When the measurement cycle is complete, the analyzer discards the sample through the drain line. The analyzer can automatically do cleaning cycles and calibrations for better measurement performance. Refer to Figure 1.
The sample must be prepared and filtered before analysis. Refer to Sample requirements on page 4. Based on the system configuration, one or two analyzers can connect to a FILTRAX instrument for filtration (or an applicable sample feed) and measure one or two parameters. Refer to System configuration options on page 16.
7
General information
Figure 1 Product overview
1 PHOSPHAX sc LR 6 Piston pump 11 Valve block
2 Status indicator light
3
7 Safety glass 12 Overflow vessel
3 Door lock 8 Reagent pumps 13 Transport lock
4 PHOSPHAX indoor sc LR 9 Measuring cell 14 Lever
5 Pocket for manual (only in outdoor
10 Analytics panel
models)
3
Refer to Status indicator light on page 9.
4
Refer to Remove the transport lock on page 14.
8
4
General information

2.2.1 Status indicator light

The status indicator light shows the analyzer condition. Refer to Table 2.
Table 2 Status indicator description
Color Status
Green The analyzer is in operation with no warnings, errors or reminders.
Orange The analyzer is in operation with active warnings or reminders.
Red The analyzer is not in operation because of an error condition. An important problem has occurred. It is necessary
to resolve the error before further operation is possible.
Flashing There is no communications between the analyzer and the controller.

2.3 Product components

Make sure that all components have been received. Refer to Figure 2. If any items are missing or damaged, contact the manufacturer or a sales representative immediately.
9
General information
Figure 2 Product components
1 PHOSPHAX sc LR 10 Angle bracket, wall mount 19 Hose plug (2x)
2 Door keys 11 Console bracket, wall mount 20 Sealing disc
3 Tubing plug (3x) 12 Blind plug 21 Blind plug
4 Sealing plug (3x) 13 Sample tube 22 Cleaning Solution C
5 Sealing plug type 2 (not used) 14 Drain tube 23 Standard Solution S
6 Screw, M5 × 40 (2x) 15 Tube cutter 24 Reagent A
7 Screw, M5 × 8 (2x) 16 Collecting tray 25 Reagent B
8 Lock washer, M5 (2x) 17 Ferrule (4x)
9 Lock washer, M6 (2x) 18 Flangeless nut (4x)
10

Section 3 Installation

Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the document.

3.1 Installation guidelines

Install the instrument:
As near the sample source as possible to decrease analysis delay
In a clean, dry, well ventilated and temperature controlled location
In a location with minimum vibrations that has no direct exposure to sunlight
In an environmental enclosure that supplies protection from precipitation and direct sunlight, good ventilation and temperature control if installed outdoors
In a location where the power switch and power cord are visible and easily accessible
In a location where there is sufficient clearance around it to make plumbing and electrical connections

3.2 Mechanical installation

3.2.1 Attach the instrument to a wall

Risk of injury or death. Make sure that the wall mounting is able to hold 4 times the weight of the equipment.
D A N G E R
D A N G E R
C A U T I O N
Personal injury hazard. Instruments or components are heavy. Use assistance to install or move.
The object is heavy. Make sure that the instrument is securely attached to a wall, table or floor for a safe operation.
Attach the instrument upright and level on a flat, vertical surface. Keep a minimum clearance of 813 mm (32 in.) in front of the instrument to open the door. Refer to Figure 3. Mounting hardware is supplied by the user. Make sure that the fastening has sufficient load bearing capacity (approximately 160 kg). The wall plugs must be selected and approved to suit the properties of the wall. Refer to the illustrated steps that follow.
For rail mount and stand mount installations, refer to the documentation supplied with the mounting hardware.
11
Installation
Figure 3 Mounting dimensions
12
Installation

3.2.2 Open the enclosure

Open the analyzer enclosure to get access to the wiring connections and plumbing.
C A U T I O N
Personal injury hazard. The object is heavy. Make sure that the instrument is securely attached to a wall, table or floor for a safe operation.
C A U T I O N
Electrical shock hazard. Make sure that no water can enter the enclosure or come into contact with the circuit boards.
13
Installation
Figure 4 Open the door
Use the door hook to open the door safely. Refer to the illustrated steps that follow.
As an alternative, remove the door for better access during installation and maintenance procedures. Refer to Figure 5. Make sure to install and close the door before operation.
Figure 5 Remove the door

3.2.3 Remove the transport lock

Remove the transport lock from the analyzer. Refer to Figure 1 on page 8.
Note: Keep the transport lock for storage or shipping.
14

3.3 Electrical connectors and plumbing access ports

Figure 6 shows the electrical connectors and fittings on the instrument. Use the tubing
plug to put tubing or cables through the analyzer access ports. To keep the environmental rating of the enclosure, make sure that there is a sealing plug in the access ports that are not used.
Refer to System configuration options on page 16 to find the correct plumbing installation.
Figure 6 Electrical connectors and fittings
Installation
1 Analyzer access ports 4 Tubing plug
2 Power and data connections (factory installed) 5 Sealing plug5.
3 Tubing or cables

3.4 Plumbing

D A N G E R
Fire hazard. This product is not designed for use with flammable liquids.
N O T I C E
Do not install reagents until all plumbing is complete.
Make sure to use the specified tubing size.

3.4.1 Sample line guidelines

Select a good, representative sampling point for the best instrument performance. The sample must be representative of the entire system.
To prevent erratic readings:
Collect samples from locations that are sufficiently distant from points of chemical additions to the process stream.
5
Use the sealing plug to close access ports that are not used.
15
Installation
Make sure that the samples are sufficiently mixed.
Make sure that all chemical reactions are complete.

3.4.2 Drain line guidelines

Correct installation of the drain lines is important to make sure that all of the liquid is removed from the instrument. Incorrect installation can cause liquid to go back into the instrument and cause damage.
Make the drain lines as short as possible.
Make sure that the drain lines have a constant slope down.
Make sure that the drain lines do not have sharp bends and are not pinched.
Make sure that the drain lines are open to air and are at zero pressure.

3.4.3 Tubing considerations

Plan cable and tubing path to prevent sharp bends and tripping hazards. The analyzer uses different tubing types for plumbing connections. The type of tubing is based on the analyzer configuration:
Ø 3.2 mm: sample line tubing
Ø 6 mm: unheated drain tubing
Ø 22 mm: heated drain tubing
Always put the drain tubing so that there is a continuous fall (minimum 3°) and the outlet is open to air (not pressurized). Make sure the drain tubing is less than 2 meters (6.56 ft).

3.5 System configuration options

Before plumbing or electrical installation, find the correct system configuration option based on the number of analyzers, sample filtration, drain line and number of measured parameters6. Refer to Table 3.
Table 3 System configuration options
Location Filtration Drain Number of
analyzers
Outdoor FILTRAX Heated 1 1 Refer to Plumbing one
2 heated 2 2 Refer to Plumbing two
Number of parameters
Plumbing option
outdoor analyzer
on page 18.
outdoor analyzers
on page 19.
6
Refer to Two-parameter configuration on page 29.
16
Table 3 System configuration options (continued)
Installation
Location Filtration Drain Number of
analyzers
Outdoor Continuous
sample feed
Indoor FILTRAX Unheated 1 1 Refer to Plumbing one
Heated 1 1 Refer to Plumbing one
2 heated 2 2 Refer to Plumbing two
Number of parameters
Plumbing option
outdoor analyzer with continuous sample feed
on page 21.
outdoor analyzers with continuous sample feed
on page 22.
indoor analyzer
on page 24.
Unheated 2 2 Refer to Plumbing two
indoor analyzers
on page 25.
17
Installation
Table 3 System configuration options (continued)
Location Filtration Drain Number of
analyzers
Indoor Continuous
sample feed
Unheated 1 1 Refer to Plumbing one
Unheated 2 2 Refer to Plumbing two

3.5.1 Plumbing one outdoor analyzer

This system configuration option uses one sc analyzer with the FILTRAX instrument for the sample line. The waste from the analyzer is released into an open drain through the optional heated drain hose.
Do the steps that follow to install one outdoor analyzer. Refer to Figure 7.
Number of parameters
Plumbing option
indoor analyzer with continuous sample feed
on page 27.
indoor analyzers with continuous sample feed
on page 27.
1. Install the FILTRAX into the sample stream. Refer to the FILTRAX User Manual for more information.
2. Use a tubing plug to put the heated sample hose from the FILTRAX through the analyzer access port.
3. Use a tubing plug to put the heated drain hose through the analyzer access port.
Note: The two samples lines of the heated drain hose are not used.
4. Use the sealing plug to close access ports that are not used.
5. Connect the heated drain connections. Refer to Connect the optional heated drain
on page 34.
6. Connect the heated drain tube to the sample outlet T-fitting.
18