GW Instek GDS-122 User Manual

GDS-122 Rechargeable Battery Pack
122 oscilloscope.
The 7.4VDC/3500mAh battery pack consists of an array of
2 oscilloscope is designed to work with the
rechargeable battery pack. A fully charged pack will
provide three hours of battery life. Please read the
ion)
disposed of properly at
the end of battery’s life. There may be specific legal
requirements for battery collection and disposal in your
area. Contact your local electronics recycler, relevant legal
G
GD
DSSSS-
GG
DD
B
BATTERY
ATTERY P
BB
ATTERY ATTERY
-1
12
11
22
22
This battery pack is for use with the GDS-
Lithium ion battery cells.
The GDS-12
2
R
RECHARGEABLE
22 PACK
ACK
PP
ACKACK
Part No. 82DS-12201M0
ECHARGEABLE
RR
ECHARGEABLE ECHARGEABLE
Safety Summary
Safety Summary
Safety Summary Safety Summary
To avoid potential hazards, use this product only as specified.
Recharge Battery Properly
Do not operate without covers:
Do not operate with suspected failures
Do not operate in wet/damp conditions. Do not operate in an explosive atmosphere. Keep oscilloscope surfaces clean and dry.
following notes before operation.
Recharge the battery pack only from the oscilloscope at the recommended temperature (0~50).
Do not operate this product with covers or panels removed.
If you suspect there is damage to this oscilloscope, have it inspected by qualified service personal.
Battery Recycling
Battery Recycling
Battery RecyclingBattery Recycling
This battery pack contains two Lithium ion (Li­batteries which must be recycled or
GDS-122 Rechargeable Battery Pack
authority, or official representative for assistance in
recycling of the battery pack.
Battery Replacement and Installation Procedure
Battery Replacement and Installation Procedure
Battery Replacement and Installation Procedure Battery Replacement and Installation Procedure
To avoid potential hazards, use this product only as specified.
Note
Replacement of the battery is an easy procedure that can be performed with basic equipment. Please note that the serial number on the face of the old battery must be transferred to the new battery to retain warranty and service records. The serial number location is shown below.
Serial number location
Equipment
Phillips screw driver x 1
Replacement Procedure
Hobby knife x 1
Super glue (or any plastic bonding epoxy)
1. Remove the protective rubber casing.
3. Take out the hinge assembly and rear stand.
2. Remove three retaining screws on the rear.
4. Remove the four screws under the rear stand.
GDS-122 Rechargeable Battery Pack
the plastic sticker from the
5. Take the battery off. Remove the battery lead from its socket.
7. Use a hobby knife to peel
original battery.
6. The battery is ready for replacement.
8. Transfer the sticker to the new battery. Use super glue sparingly if necessary to affix the sticker in place.
9. Install the new battery using the reverse procedure of the removal of the old battery.
GDS-122 Rechargeable Battery Pack
Charging the Battery Pack
Charging the Battery Pack
Charging the Battery Pack Charging the Battery Pack
To avoid potential hazards, use this product only as specified.
Note
Configuration
Specifications
The Battery Pack needs to be fully charged for first-time use. The battery pack begins to charge as soon as the oscilloscope is connected to external AC power source. It takes FOUR hours to fully charge the battery when oscilloscope is turned OFF.
The battery pack stops charging under the following conditions:
The battery pack is fully charged.
The battery pack temperature exceeds the operation
temperature specification in the below table.
Configuration Typical charging time Battery pack charging in
4 hours oscilloscope with oscilloscope turned OFF
Battery Output for each one 7.4VDC, 3500mAh Operating Temperature 0°C~50°C, discharging and
charge Storage Temperature -20°C ~+60°C
Warranty
Warranty
Warranty Warranty
GWInstek warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of three (3) months
from the date of shipment from authorized GWInstek representatives. If a product proves defective within the replacement period, GWInstek will repair or provide a replacement as described in the complete warranty statement. EXCEPT AS PROVIDED IN THIS DOCUMENT OR IN THE APPLICABLE WARRANTY STATEMENT, GWINSTEK MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL GW INSTEK BE LIABLE FOR INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES.