GW Instek GDS-1000A-U User Manual

Digital Storage Oscilloscope
GDS-1000A-U Series
QUICK START GUIDE
GW INSTEK PART NO. 82DS-112AUMA1
ISO-9001 CERTIFIED MANUFACTURER
This quick start guide contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will Corporation.
The information in this quick start guide was correct at the time of printing. However, Good Will continues to improve its products and therefore reserves the right to change the specifications, equipment, and maintenance procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
SAFETY INSTRUCTIONS
This section contains the basic safety symbols that may appear on the accompanying user manual CD or on the instrument. For detailed safety instructions and precautions, please see the Safety Instructions chapter in the user manual CD.
Safety Symbols
These safety symbols may appear in the user manual or on the instrument.
Warning
Warning: Identifies conditions or practices that could result in injury or loss of life.
Caution
Caution: Identifies conditions or practices that could result in damage to the instrument or to other properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased.
Power Cord for the United Kingdom
When using the instrument in the United Kingdom, make sure the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons.
WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
Green/ Yellow:
Earth Blue: Neutral Brown: Live (Phase)
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows: The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black. The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of
0.75mm
2
should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous
wiring must be immediately destroyed and replaced in accordance to the above standard.
GETTING STARTED
The Getting started chapter introduces the oscilloscope’s main features, appearance, and set up procedure.
Main Features
Model name Frequency bandwidth Input channels
GDS-1072A-U DC–70MHz (–3dB) 2
GDS-1102A-U DC–100MHz (–3dB) 2
GDS-1152A-U DC–150MHz (–3dB) 2
Performance
1 GS/s real-time sampling rate
25GS/s equivalent-time sampling
rate
2M points record length
Up to 10ns peak detection
2mV~10V vertical scale
1ns ~ 50s time scale
Features
5.7 inch color TFT display
Saving and recalling setups and
waveforms
27 automatic measurements
Multi-language menu (12
languages)
Math operation: Addition,
Subtraction, Multiplication, FFT, FFT RMS
Zoom FFT
Data logging
Go-NoGo testing
Edge, Video, Pulse Width triggers
Probe factor from 0.1X~2000X
voltage/current
Interface
USB 2.0 full-speed interface for
saving and recalling data
Calibration output
External trigger input
USB B type (slave) interface for
remote control
PictBridge Printer compatible
Package Contents and Accessories
Standard Accessories
Part Number Description
82DS-112AUEA1
User Manual CD
82DS-112AUMA1
Quick Start Guide
(this document) GTP-070A-4 for GDS-1072A-U
Passive probe,
70MHz, 10x, 1x GTP-100A-4 for GDS-1102A-U
Passive probe,
100MHz, 10x, 1x GTP-150A-2 for GDS-1152A-U
Passive probe,
150MHz, 10x, 1x Region Dependent
Power cord x1
Front Panel
Description
1. LCD display 2. Function keys
3. Variable knob 4. Vertical position knob
5. VOLTS/DIV knob 6. Horizontal position
knob
7. Menu keys 8. Trigger level knob
9. Horizontal menu key 10. Trigger keys
11. TIME/DIV knob 12. EXT TRIG
13. Ground Terminal 14. CH2 Terminal
15. CH1/CH2 Math keys 16. CH1 Terminal
17. Probe Compensation
output
18. USB A type port
19. Power Switch
Rear Panel
Description
1. Security lock slot 2. Fuse socket
3. Power cord socket 4. CAL output
5. USB B type port
Setting up the Oscilloscope
This section describes how to set up the oscilloscope properly including adjusting the handle, connecting a signal, adjusting the scale, and compensating the probe. Before operating the oscilloscope in a new environment, run these steps to make sure the oscilloscope is functionally stable.
1. Pull both bases of the handle out slightly.
2. Turn to one of the three
preset positions.
3. Connect the power cord.
4. Press the power switch. The
display will become active in approximately 10 seconds.
5. Reset the system by
recalling the factory settings. Press the Save/Recall key, then Default Setup.
6. Connect the probe between the Channel1 input
terminal and probe compensation signal output (2Vp-p, 1kHz square wave).
7. Set the probe attenuation voltage to x10.
Optional Accessories
Part Number Description
GTL-242 USB 2.0 Cable, type
A-B
GTL-110 Test Lead (BNC-
BNC)
GSC-006 Soft carry case
Display and Panel Overview
Display Overview
1
2 3 4
5
6789
10
Description
1. Trigger position 2. Waveform position
3. Trigger status 4. Acquisition
5. Menu 6. Trigger condition
7. Frequency 8. Horizontal status
9. Vertical status 10. Waveform marker
8. Press the Autoset key. A
square waveform will appear in the center of the display.
9. Press the Display key, then
Type and select the vector waveform type.
10. Turn the adjustment point on the probe to flatten
the square waveform edge.
Over
Compensation
Normal
Under
Compensation
11. Setting up the oscilloscope is complete. You may
start to use the oscilloscope.
SPECIFICATIONS
The specifications apply when the oscilloscope is powered on for at least 30 minutes under +20°C~+30°C.
Model Specific Specifications
GDS-1072A-U Bandwidth (–3dB)
DC coupling: DC ~ 70MHz AC coupling: 10Hz ~ 70MHz
Bandwidth Limit
20MHz (3dB)
Trigger Sensitivity
0.5div or 5mV (DC ~ 25MHz)
1.5div or 15mV (25MHz~70MHz)
External Trigger Sensitivity
~ 50mV (DC~25MHz) ~ 100mV (25MHz~70MHz)
Rise Time
< 5.8ns approx.
G
DS-1102A-U
Bandwidth (–3dB)
DC coupling: DC ~ 100MHz AC coupling: 10Hz ~ 100MHz
Bandwidth Limit
20MHz (3dB)
Trigger Sensitivity
0.5div or 5mV (DC ~ 25MHz)
1.5div or 15mV (25MHz~100MHz)
External Trigger Sensitivity
~ 50mV (DC~25MHz) ~ 100mV (25MHz~100MHz)
Rise Time
< 3.5ns approx.
G
DS-1152A-U
Bandwidth (–3dB)
DC coupling: DC ~ 150MHz AC coupling: 10Hz ~ 150MHz
Bandwidth Limit
20MHz (3dB)
Trigger Sensitivity
0.5div or 5mV (DC ~ 25MHz)
1.5div or 15mV (25MHz~150MHz)
External Trigger Sensitivity
~ 50mV (DC~25MHz) ~ 100mV (25MHz~100MHz)
Rise Time
< 2.3ns approx.
Common Specifications
Vertical Sensitivity
2mV/div~10V/Div (1-2-5 increments)
Accuracy
± (3% x |Readout|+0.1div + 1mV)
Bandwidth
See model-specific specifications
Rise Time
See model-specific specifications
Input Coupling
AC, DC, Ground
Input Impedance
1M±2%, ~15pF
Polarity
Normal, Invert
Maximum Input
300V (DC+AC peak), CAT II
Math Operation
+, –, ×, FFT, FFT rms
Offset Range
2mV/div~50mV/div: ±0.4V 100mV/div~500mV/div: ±4V 1V/div~5V/div: ±40V 10V/div : ±300V
Trigger Sources
CH1, CH2, Line, EXT
Modes
Auto, Normal, Single, TV, Edge, Pulse
Coupling
AC, DC, LF rej, HF rej, Noise rej
Sensitivity
See model-specific specifications
Holdoff
40ns ~ 2.5s
E
xternal Trigger
Range
DC: ±15V, AC: ±2V
Sensitivity
See model-specific specifications
Input Impedance
1M±2%, ~15pF
Maximum Input
300V (DC+AC peak), CATII
H
orizontal
Range
1ns/div~50s/div, 1-2.5-5 increment Roll: 50ms/div – 50s/div
Modes
Main, Window, Window Zoom, Roll, X-Y
Accuracy
±0.01%
Pre-Trigger
10 div maximum
Post-Trigger
1000 div
X
-Y Mode
X-Axis Input
Channel 1
Y-Axis Input
Channel 2
Phase Shift
±3° at 100kHz
Signal Acquisition Real-Time
1G Sa/s maximum
Equivalent
25G Sa/s maximum
Vertical Resolution
8 bits
Record Length
Maximum; 2M points (1 channel), 1M points (2 channels)
Acquisition
Normal, Peak Detect, Average
Peak Detection
10ns (500ns/div ~ 50s/div)
Average
2, 4, 8, 16, 32, 64, 128, 256
C
ursors and Measurement
Voltage
Vpp, Vamp, Vavg, Vrms, Vhi, Vlo, Vmax, Vmin, Rise Preshoot/ Overshoot, Fall Preshoot/ Overshoot
Time
Freq, Period, Rise Time, Fall Time, + Width, – Width, Duty Cycle
Delay
FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF
Cursors
Voltage difference (ΔV) and Time difference (ΔT) between cursors
Auto Counter
Resolution: 6 digits, Accuracy: ±2% Signal source: All available trigger source except the Video trigger
C
ontrol Panel Function
Autoset
Automatically adjust Vertical Volt/div, Horizontal Time/div, and Trigger level
Save/Recall
Up to 15 sets of measurement conditions and waveforms
Display LCD
5.6 inch, TFT, brightness adjustable
Resolution (dots)
234 (Vertical) x 320 (Horizontal)
Graticule
8 x 10 divisions
Display Contrast
Adjustable
I
nterface
USB Slave Connector
USB1.1 & 2.0 full speed compatible (flash disk not supported)
USB Host connector
Image (BMP) and waveform data (CSV)
P
robe Compensation Signal
Frequency range
1kHz ~ 100kHz adjustable, 1kHz step
Duty cycle
5% ~ 95% adjustable, 5% step
Amplitude
2Vpp±3%
P
ower Source
Line Voltage
100V~240V AC, 47Hz~63Hz
Power Consumption
18W, 40VA maximum
Fuse Rating
1A slow, 250V
O
peration Environment
Storage Temperature
-10°C~60°C, no condensation
Relative humidity
93% @ 40°C 65% @ 41°C~60°C
D
imensions and Weight
Dimensions
310(W) x 142(H) x 140(D) mm
Weight
Approx. 2.5kg
Probe Specifications
GTP-150A-2 (GDS-1152A-U) Probe Position
Position x10 Position x1
Attenuation Ratio
10:1 1:1
Bandwidth
DC ~ 150MHz DC~6MHz
Input Resistance
10M when used with 1M input
1M when used with 1M input
Input Capacitance
17pF approx. 47pF approx.
Maximum Input Voltage
500V CAT I, 300V CAT II (DC+Peak AC) Derating with frequency
300V CAT I, 150V CAT II (DC+Peak AC) Derating with frequency
Temperature
–10°C ~ 55°C
Relative Humidity
85% @35°C
Safety Standard
EN 61010-031 CAT II
G
TP-100A-4 (GDS-1102A-U)
Probe Position
Position x10 Position x1
Attenuation Ratio
10:1 1:1
Bandwidth
DC ~ 100MHz DC~6MHz
Input Resistance
10M when used with 1M input
1M when used with 1M input
Input Capacitance
14.5~17.5pF approx.
85~115pF approx.
Maximum Input Voltage
600Vpk, Derating with frequency
200Vpk, Derating with frequency
Temperature
–10°C ~ 50°C
Relative Humidity
85% @35°C
Safety Standard
EN 61010-031 CAT II
GTP-070A-4 (GDS-1072A-U) Probe Position
Position x10 Position x1
Attenuation Ratio
10:1 1:1
Bandwidth
DC ~ 70MHz DC~6MHz
Input Resistance
10M when used with 1M input
1M when used with 1M input
Input Capacitance
28pF~32pF 120pF~220pF
Maximum Input Voltage
600Vpk, Derating with frequency
200Vpk, Derating with frequency
Temperature
–10°C ~ 50°C
Relative Humidity
85%
Safety Standard EN 61010-031 CAT II
Dimensions
V
ID
/
EMI
TV
ID
/S
TLOV
V
ID
/
S
TLOV
U
N
EM
UN
E
M
2
HCH
TAM
1
HC
Acquire Display Utility Help
Run/Stop
VARIABLE
FORCE
Autoset
Cursor
SINGLE
Hardcopy
Measure Save/Recall
LEVEL
REGGIRTLATNOZI
R
OHLACITREV
CH1
CAT300V
M
15pF
MAX. 300Vpk
1
CH2
EXT TRIG
CAT
300V
M
15pF
MAX. 300Vpk
1
YX
310.0
341.5
142.0
162.3
115.1
149.0
159.0
150 MHz 1 G Sa/s
Digital Storage Oscilloscope
GDS-1152A-U
EC Declaration of Conformity
We
GOOD WILL INSTRUMENT CO., LTD.
No.7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. No. 69, Lushan Road, Suzhou New District Jiangsu, China declares that the below mentioned product
GDS-1072A-U, GDS-1102A-U, GDS-1152A-U
Are herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Law of Member States relating to Electromagnetic Compatibility (2004/108/EC) and Low Voltage Equipment Directive (2006/95/EC). For the evaluation regarding the Electromagnetic Compatibility and Low Voltage Equipment Directive, the following standards were applied:
EMC
EN 61326-1 : EN 61326-2-1:
Electrical equipment for measurement, control and laboratory use –– EMC requirements (2006)
Conducted and Radiated Emissions CISPR11: 2003+A1: 2004+A2: 2006
Electrostatic Discharge IEC 61000-4-2: 2001
Current Harmonic EN 61000-3-2: 2006
Radiated Immunity IEC 61000-4-3: 2006+A1: 2007
Voltage Fluctuation EN 61000-3-3: 1995+A1: 2001+A2 : 2005
Electrical Fast Transients IEC 61000-4-4: 2004+Corr.1 : 2006+Corr.2 : 2007
-------------------------
Surge Immunity IEC 61000-4-5: 2005
-------------------------
Conducted Susceptibility IEC 61000-4-6: 2003+A1: 2004+A2: 2006
-------------------------
Power Frequency Magnetic Field IEC 61000-4-8: 2001
-------------------------
Voltage Dips/ InterruptsIEC 61000­4-11: 2004
Safety
Low Voltage Equipment Directive 2006/95/EC Safety Requirements
IEC/EN 61010-1: 2001