GW Instek GCM-303 User Manual

Please read this instruction manual before using the meter and keep it properly for contingent use.
PRECAUTION:
To avoid danger and damage happened during operation, the following symbols are used as points for attention.
:Warning:
Improper use of the meter may bring hurt or even death to body. Please read the operation carefully.
:Caution:
Improper use of the meter may bring hurt or even death to body. Please read the operation carefully.
:Dual insulation
:AC - (Alternating Current) voltage / current
:DC - (Direct Current) voltage
:Grounding - Earth Terminal
Warning
To prevent electricalshock or fire!
4
Before measurement, make sure that the test leads
1
and function switch has been set properly. Before switching among functions, remove the test
1
leads off the measured object. Before measurement, make sure the circuit current
1
of object won't exceed the maximum measurement range.
1
Do not use this meter if any crack or damage occurred in the case or test leads.
1
Do not open the case of meter or the battery lib during measurement.
1
Please keep your hands behind the guard ring of test leads while measuring with test leads.
1
Please keep your hands below the guard ring of the meter while measuring with sensoring jaw.
1
Before proceeding resistance measurement, turn off the power to the circuit under test first.
1
Never use the meter in rainy or humid environment or with wet hands.
1
Before proceeding current measurement, make sure to remove the test leads from the input terminals.
-1- -2-
Warning
To prevent damage to the meter or electrical
4
shock!
According to the safety standard, the maximum voltage input power is classified as follows to protect the users against transient impulse voltage in power lines.
Over-voltage Category (CAT.) Maximum input voltage
CAT II 600V
Caution
1
Do not use the meter near equipment emitting noise or under an environment with sudden temperature change; otherwise, unstable or erroneous reading will appear.
1
Take the batteries out of the meter if it will be left idle for a long time.
1
After measurement, switch the function knob back to
OFF position. As there will be slight power consumption
under auto power off mode.
1
Please position the conductor in the center of jaw in order to ensure the accuracy of measurement while measuring current.
1
Please make sure to keep out of high current to ensure the accuracy of measurement while measuring current.
1
Do not use organic solvent to clean the meter but with a soft cloth if necessary.
1
Do not expose the meter under direct sunshine or extreme temperature or in moisture places.
1
When the measurement values appear irregularly
or the symbol displays, replace the batteries immediately to ensure normal operation.
( 1 ) NAME OF PARTS
j
2
1
k l
3
10
4
AC
CLAMP METER AUTO RANGE
A
OFF
5
9
COM
MAX
SELECT
V
V
CAT
600V
11
m
6
7
n
8
6
Jaw
Position the conductor in the center of jaw in order to ensure the accuracy of reading while measuring current.
Opening of the jaw Guard ring
Keep your hands below the guard ring of the meter while measuring with sensoring jaw.
Clamp trigger
Press down the trigger to open the jaw.
Function switch knob
OFF
Turn off the power
A
AC current measurement
V
AC voltage measurement
V
DC voltage measurement
Resistance measurement
Diode / Continuity check
/
MAX key
Press MAX key during measurement, symbol will
MAX
appear on the LCD; and the maximum value will be locked and renewed instantaneously. To cancel this function, just press MAX key again and
ymbol will disappear.
s
Note:
This function is only
applicable to , &
A V
MAX
V
-3-
-4-
7
SELECT key
Transform between diode and continuity check.
8
Name plate
Mark product brand and model number
9
LCD Display
MAX
Show measurement symbols, units and values
AUTO
(2) MEASURING INSTRUCTIONS
n AC Current Measurement ( )
Measuring range: 200A~600A (2 ranges, auto-ranging)
1.Set the function switch knob on
2.Press down the clamp trigger to open the jaw, place one conductor in the center of the jaw (as below drawing), then read the value when it stabilizes.
Note:
3.The meter will choose the appropriate range to measure
Please put the conductor in the center of jaw in order to avoid serious inaccuracy
A
A
Symbols / Units Description
Lit when in DC mode measurement Lit when in AC mode measurement Negative polarity indicator Lit when in continuity check
AUTO
Auto-ranging indicator Low battery indicator Unit for current measurement
,
,,
MAX
Unit for voltage measurement Unit for resistance measurement Maximum value lock indicator Lit when in diode measurement Measured value display
10
COM Terminal
For connecting the negative input end (black test lead) for DCV, ACV,
11
+
terminal
&
,
measurement
For connecting the positive input end (red test lead) for DCV, ACV,
&
,
measurement
automatically.
4.When measurement finished, set the function switch
knob OFF position to turn off the meter.
on
Note:
If the measurement is conducted in a place with dim light, you may press MAX key to lock the value measured and read it in other places with proper illumination.
MAX
AC AC
CLAMPMETER AUTO RANGE
SELECT
V
V
A
OFF
-6--5-
OFF
CLAMPMETER AUTO RANGE
V
A
SELECT
V
MAX
nnAC Voltage Measurement ( )
V
Measuring range: 2V-600V (4 ranges, auto-ranging)
1.Set the function switch knob on
V
2.Plug the black test lead into COM terminal and the red one into terminal
+
3.Connect the test leads to the cir uit under test and then
c
read the value when it stabilizes
4.The meter will choose the appropriate range to
AC
CLAMPMETER AUTO RANGE
OFF
MAX
SELECT
V
V
A
measure automatically
5.When measurement finished, set the function switch knob
n OFF position to turn off
o
he meter.
t
COM
600V
n Resistance Measurement ( )
Measuring range: 200 -20M (6 ranges, auto-ranging)
1.Set the function switch knob on
2.Plug the black test lead into COM terminal and the red one into terminal
3.Connect the test leads to the circuit under test and then read the value when it stabilizes
4.The meter will choose the appropriate range to measure automatically
5.When measurement finished, set the function switch knob on OFF position to turn off the meter.
: Before undergoing resistance measurement,
firstly switch off the power to the circuit under test and fully discharge the capacitor.
+
DC Voltage Measurement ( )
V
Measuring range: 200mV-600V (5 ranges, auto-ranging)
1.Set the function switch knob on
V
2.Plug the black test lead into COM terminal and the red one into terminal
+
3.Connect the test leads to the circuit under test and then read the value when it
MAX
AC
stabilizes
4.The meter will choose the
CLAMPMETER AUTO RANGE
OFF
SELECT
V
V
A
12
V
appropriate range to measure
utomatically
a
6.When measurement finished,
COM
600V
set the function switch knob on OFF position to turn off the meter.
-7- -8-
AC
CLAMPMETER AUTO RANGE
A
OFF
COM
MAX
SELECT
V
V
CAT
600V
n Diode Check ( )
1.Set the function switch knob on
2. Symbol will appear on the LCD
3.Connect the test leads to the diode and then read the value when it stabilizes
(A)Forward-bias Diode Test
Connect black test lead to the cathode and red one to the anode
Silicon diode value reading approximate 0.5~0.7V Germanium diode value reading approximate 0.5~0.7V
Note that reading close to 0V represents a short­circuit and "OL" symbol indicates an open-circuit.
Red testing lead
n Continuity Measurement ( )
1.Set the function switch knob on
2.Press SELECT key until symbol appears on LCD
3.Plug the black test lead into COM terminal and the red one into terminal
4.Connect the test leads to the circuit under test. If circuit is continuous or less than 60 ( beeper will sound
5.When measurement finished, set the function switch knob on OFF position to turn off the meter.
+
_
+
20 ), the
A
MAX
AC
CLAMPMETER AUTO RANGE
SELECT
V
V
A
OFF
B
COM
600V
Black testing lead
(B)Reverse-bias Diode Test
Connect black test lead to the anode and red one to the cathode. Normally, it shows OL on display, indicating that the diode under test is normal. The diode is defective if the display gives a certain voltage level.
4.When measurement finished, set the function knob
on OFF position to turn off the meter.
-9- -10-
switch
AC
CLAMPMETER AUTO RANGE
OFF
COM
MAX
SELECT
V
V
A
600V
AC
CLAMPMETER AUTO RANGE
OFF
COM
MAX
SELECT
V
V
A
600V
(3) AUTO POWER OFF (POWER-SAVING)DEVICE
When power on the meter and you don't touch any key or function switch knob for 15 minutes, the meter will turn the power off automatically. One minute before the meter shut down, the alarm sounds to warn the users. Once the meter turns the power off already, you can press the MAX key to regenerate the meter again.
(4) Replacing Batteries
If symbols appears, the batteries fall below the normal operation voltage. Replace them with 2 new batteries. (Standard UM-4 or R03 AAA batteries)
CAUTION
l
Before replacing batteries, make sure to disconnect the clamp meter from the circuit under test.
l
Replace two new batteries at the same time, and make sure you put the batteries at correct polarities.
(5) Battery Replacement Steps
1.Abort the measuring action
2.Turn the function switch knob back to OFF
3.Remove the screw on the back of casing (as drawing)
4.Open the battery lid
5.Load the new batteries
6.Install the battery lid into the casing
a
nd fasten it with the screw
Remove the screw on the back of casing
WARNING
TOAVOID ELECTRICAL SHOCK, REMOVETEST LEADS BEFORE OPENING CASE.
DANGER
DO NOTUSE ON BARE CONDUCTORS.
PLEASE READ MANUAL FOR SAFETY BEFORE USING.
USE BATTERY 1.5V X2
AAA SIZE
1.5V
SIZE "AAA"
(6) Specification
1. General Specification:
l
Max Clamp Size:
l
Measurement Functions:
l
Additional Functions:
l
LCD Display:
Unit & function indication, 1999 digits as maximum reading, negative polarity indicator, overload indicator ( "OL" indicating overload of resistance, beeper, diode), indicating low battery.
Range:
l
Sampling Rate:
l
Operation Temperature/Humidity:
l
Auto-ranging
0 C~50 C (32 F~122 F) / below 80% R.H. (no condensation)
Storage Temperature/Humidity:
l
-10 C~60 C (14 F~140 F) / below 70% R.H. o condensation)
(n
Power Supply:
l
batteries
Battery Life:
l
Alkaline batteries approx. 400 hours General batteries approx. 240 hours
Dimensions:
l
Weight:
l
1.5V
SIZE "AAA"
approx. 200g (batteries included)
189mm(L) x 71mm(W) x 37mm(H)
30mm or 10x35mm
,,,
,,
V
V
A
Max hold, auto power off
approx. 3 times per second
2 pcs of standard UM-4 or R03 AAA
Battery lid
-11- -12-
l
Comply
l
Accessories:
with
Safety Standard:
AAA 1.5V ..............2 (inside the case)
Test leads.......................................1
Instruction manual ..........................1
Carrying case.................................1
l
Optional Accessories:
AC Line Splitter
(Direct measuring with no necessity to split the wire away by negative and positive independently. Hence, it also can amplify
he small current by 10 times for easy reading)t
2. Electrical Specification:
Environment temperature/ humidity: rdg: reading digits dgt: decimal digits
IEC 61010-1 600V CAT Pollution degree 2
X1
X10
_
+
23
5 C/ below 80% R.H.
ll
n DCV measurement (set on )
V
n Resistance measurement (set on )
k
k
k
k
k
k
n Diode check (set on )
n
ACA measurement (set on )
GCM-302
n
ACV measurement (set on )
GCM-302
GCM-303
-13- -14-
A
GCM-303
V
n Continuity check (set on )
Specification and outward appearance of the product described above may be revised for modification without prior notice.