GW-INSTEK ASR-2100 EU OPT2 Datasheet

The ASR-2000 series, an AC+DC power source aiming for system integration or desktop applications, provides both rated power output for AC output and rated power output for DC output. Nine ASR-2000 output modes are available, including 1) AC power output mode (AC-INT Mode), 2) DC power output mode (DC-INT Mode), 3) AC/DC power output mode (AC+DC-INT Mode), 4) External AC signal source mode (AC-EXT Mode), 5) External AC/DC signal source mode (AC+DC-EXT Mode), 6) External AC signal superposition mode (AC-ADD Mode), 7) External AC/DC signal superposition mode (AC+DC-ADD Mode), 8) External AC signal synchronization mode (AC­SYNC Mode), 9) External AC/DC signal synchronization mode (AC+DC-SYNC Mode).
The ASR-2000 series provides users with waveform output capabilities to meet the test requirements of different electronic component development, automotive electrical devices and home appliance, including 1) Sequence mode generates waveform fallings, surges, sags, changes and other abnormal power line conditions; 2) Arbitrary waveform function allows users to store/upload user-defined waveforms; and 3) Simulate mode simulates power outage, voltage rise, voltage fall, and frequency variations. When the ASR-2000 series power source outputs, it can also measure Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, 40th-order Voltage Harmonic and Current Harmonic. In addition, the Remote sense function ensures accurate voltage output. The Customized Phase Angle for Output On/Off function can set the starting angle and ending angle of the voltage output according to the test requirements. V-Limit, Ipeak­Limit, F-Limit, OVP, OCP, OPP function settings can protect the DUT during the measurement process. In addition to OTP, OCP, and OPP protection, the ASR-2000 series also incorporates the Fan fail alarm function and AC fail alarm function.
The front panel of the ASR-2050/2100 provides a universal socket or a European socket, which allows users to plug and use so as to save wiring time. The ASR-2050R/2100R is 3U height and 1/2 Rack width design, which is compatible with ATS assembly. The ASR-2000 series supports I/O interface and is equipped with USB, LAN, External I/O and optional RS-232C and GPIB.
PANEL INTRODUCTION
Ext I/O
1
11
10
1
10
2
8
2
7
8
9
3
4
7
9
5
6
3
20
12
19
4
5
17
6
18
20
12
19
17
18
13
14
15
16
13
14
15
16
1. Air Inlet
2. LCD Screen
3. Display Mode Select Key
4. Function Keys
5. Scroll Wheel
6. Output Key
7. Hardcopy Key
8. Lock/Unlock Button
9. USB Interface Connector(A Type)
10. Power Switch Button
11. Output Socket
12. External I/O Connector
13. Exhaust Fan
14. Remote Sensing Input Terminal
15. Output Terminal
16. Line Input
17. External Signal Input/External
Synchronized Signal Input
18. RS-232C & GPIB Connectors
19. LAN Connector
20. USB Interface Connector(B Type)
OPERATING AREA FOR ASR-2000 SERIES
A.
AC Output for
ASR-2050/ASR-2050R
DC Output for
ASR-2050/ASR-2050R
The ASR-2000 series is an AC+DC power source that provides rated power output not only at the AC output, but also at the DC output. The operation areas are shown in diagrams.
MEASUREMENT ITEMS FOR ASR-2000 SERIES
B.
RMS Meas Display AVG Meas Display
AC Output for
ASR-2100/ASR-2100R
Model Name
ASR-2050 ASR-2100 ASR-2050R ASR-2100R
Power Rating
500 VA
1000 VA
500 VA
1000 VA
DC Output for
ASR-2100/ASR-2100R
Max. Output Current
5 / 2.5 A
10 / 5 A
5 / 2.5 A
10 / 5 A
Peak Meas Display
Max. Output Voltage
350 Vrms / 500 Vdc 350 Vrms / 500 Vdc 350 Vrms / 500 Vdc 350 Vrms / 500 Vdc
Voltage Harmonic Current Harmonic
The ASR-2000 series provides users with measurement capabilities including Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, 40th-order Voltage Harmonic and Current Harmonic. During the power output, the measurement
SEQUENCE MODE AND APPLICATIONS
C.
Reset Behavior at Voltage DropMomentary Drop in Supply Voltage
There are 10 sets of Sequence mode and each set has 0~999 steps. The time setting range of each step is 0.0001 ~ 999.9999 seconds. Users can combine multiple sets of steps to generate
parameters including Vrms/Irms, Vavg/Iavg and Vmax/Vmin/ Imax/Imin can be switched by users at any time to display the instantaneous calculation reading.
Starting Profile Waveform
Instantaneous Power Failure
the desired waveforms, including waveform fallings, surges, sags, changes and other abnormal power line conditions to meet the needs of the test application.
SIMULATE MODE
SIMULATE MODE
D.
Power Outage
Simulate Mode can quickly simulate different transient waveforms, such as power outage, voltage rise, voltage fall, etc.,
T, IPK HOLD & IPK, HOLD FUNCTIONS
E.
T, Ipk Measurement
T, Ipk Hold is used to set the delay time after the output (1ms ~ 60,000ms) to capture the Ipeak value and keep the maximum value. The update only functions when the measurement value is greater than the original value. The T, Ipk Hold delay time setting can be used to measure surge current at the power on process of the DUT.
Voltage Rise
Voltage Fall
for engineers to evaluate the impact of transient phenomena
on the DUT. Ex: Capacitance durability test.
SLEW RATE MODE
F.
Time Mode Slope Mode
The ASR-2000 series can set the Slew Rate Mode to determine the rise time of the voltage according to the test requirements of the DUT. Slew Rate Mode provides "Time" and "Slope" modes. When setting "Time" mode, ASR-2000 can increase output to 10~90% of
the set voltage within 100 s; and when selecting "Slope" mode,μ ASR-2000 increases output voltage by a fixed rising slope of
1.5V/ s until reaching the set voltage value.μ
Ipk Hold can be used to measure the transient surge current of the DUT at power on without using an oscilloscope and a current probe.
REMOTE SENSE FUNCTION
G.
In addition, if users decide to self-define the rise time of the output voltage, users can flexibly set the rise time of the ASR-2000 series voltage by editing the Sequence mode.
For high current output applications, the voltage drop caused by
large current passing through the load cables will affect the
measurement results. The ASR-2000 series provides the remote
sense function that can sense the voltage drop of the DUT to the
ASR-2000 series and the DUT will be compensated by the ASR-2000
series. The maximum voltage that the remote sense function can
compensate is 5% of the output voltage.
SPECIFICATIONS
ASR-2100/ASR-2100RASR 2050/ASR-2050R-
INPUT RATING (AC) NORMINAL INPUT VOLTAGE
INPUT VOLTAGE RANGE PHASE INPUT FREQUENCY RANGE MAX. POWER CONSUMPTION POWER FACTOR
*1
100Vac 200Vac
MAX. INPUT CURRENT
*1 For an output voltage of 100 V/200 V (100V/200V range), maximum current, and a load power factor of 1..
100Vac 200Vac
AC MODE OUTPUT RATINGS (AC rms)
*3
Setting Range Setting Resolution Accuracy
100 V 200 V
*4
100 V 200 V
*2
VOLTAGE
OUTPUT PHASE MAXIMUM CURRENT
MAXIMUM PEAK CURRENT
POWER CAPACITY
FREQUENCY
OUTPUT ON PHASE DC OFFSET*
*1. 100 V / 200 V range *2. For an output voltage of 17.5 V to 175 V / 35 V to 350 V, sine wave, an output frequency of 45 Hz to 65 Hz, no load, DC voltage setting 0V (AC+DC mode) and 23°C ± 5°C *3. For an output voltage of 1 V to 100 V / 2 V to 200 V, Limited by the power capacity when the output voltage is 100 V to 175 V / 200 V to 350 V. *4. With respect to the capacitor-input rectifying load. Limited by the maximum current. *5. For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum current, and the operating temperature. *6. In the case of the AC mode and output voltage setting to 0 V.
6
Setting Range Setting Resolution
Accuracy
*5
Stability
OUTPUT RATING FOR DC MODE
VOLTAGE
MAXIMUM CURRENT
MAXIMUM PEAK CURRENT
POWER CAPACITY
*1. 100 V / 200 V range *2. For an output voltage of -250 V to -25 V, +25 V to +250 V / -500 V to -50 V, +50 V to +500 V, no load, AC volatge setting 0V (AC+DC mode) and 23 ± 5℃℃ *3. For an output voltage of 1.4 V to 100 V / 2.8 V to 200 V, Limited by the power capacity when the output voltage is 100 V to 250 V / 200 V to 500 V. *4. Within 5 ms, Limited by the maximum current.
OUTPUT VOLTAGE STABILITY
LINE REGULATION LOAD REGULATION RIPPLE NOISE
*1. Power source input voltage is 100 V, 120 V, or 230 V, no load, rated output. *2. For an output voltage of 75 V to 175V/150V to 350V, a load power factor of 1, stepwise change from an output current of 0 A to maximum current(or its reverse), using the output terminal on the rear panel. *3. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel.
*1
*2
*3
*3
Setting Range Setting Resolution Accuracy
100 V 200 V
*4
100 V 200 V
*2
OUTPUT VOLTAGE WAVEFORM DISTORTION RATIO, OUTPUT VOLTAGE RESPONSE TIME, EFFICIENCY
OUTPUT VOLTAGE WAVEFORM DISTORTION RATIO OUTPUT VOLTAGE RESPONSE TIME EFFICIENCY
*1. At an output voltage of 50 V to 175 V / 100 V to 350 V, a load power factor of 1, and in AC and AC+DC mode. *2. For an output voltage of 100 V / 200 V, a load power factor of 1, with respect to stepwise change from an output current of 0 A to the maximum current (or its reverse); 10% ~ 90% of output voltage *3. For AC mode, at an output voltage of 100 V / 200 V, maximum current, and load power factor of 1 and sine wave only.
*3
MEASURED VALUE DISPLAY
VOLTAGE
RMS, AVG Value
PEAK Value
*1
Resolution Accuracy Resolution
*2
*2
Accuracy
CURRENT
RMS, AVG Value
PEAK Value
POWER
Active (W)
Apparent (VA)
Reactive (VAR)
LOAD POWER FACTOR
Resolution Accuracy
Resolution Accuracy
Resolution Accuracy Resolution Accuracy Resolution Accuracy
Range
*3
*4
*5
*5*6
*5*7
Resolution
LOAD CREST FACTOR
Range Resolution
100 Vac to 240 Vac 90 Vac to 264 Vac Single phase, Two-wire 47 Hz to 63 Hz
0 VA or less80
0.95 (typ.)
0.90 (typ.) A8
4A
*1
0.0 V to 175.0 V / 0.0 V to 350.0 V
100 Vac to 240 Vac 90 Vac to 264 Vac Single phase, Two-wire 47 Hz to 63 Hz 1500 VA or less
0.95 (typ.)
0.90 (typ.) 15 A
7.5 A
0.1 V
±(0.5 % of set + 0.6 V / 1.2 V) Single phase, Two-wire
5 A
2.5 A
20 A 10 A 500 VA
10 A 5 A 40 A 20 A 1000 VA
AC Mode: 40.00 Hz to 999.9 Hz, AC+DC Mode: 1.00 Hz to 999.9 Hz
0.01 Hz (1.00 to 99.99 Hz), 0.1 Hz (100.0 to 999.9 Hz)
For 45 Hz to 65 Hz: 0.01% of set, For 40 Hz to 999.9 Hz: 0.02% of set ± 0.005%
0.0° to 359.9° variable (setting resolution 0.1°)
Within ± 20 mV (TYP)
*1
-250 V to +250 V / -500 V to +500 V
0.1 V
±(|0.5 % of set| + 0.6 V / 1.2 V)
5 A
2.5 A
20 A 10 A 500 W
10 A 5 A 40 A 20 A 1000 W
±0.2% or less
0.15% @45 - 65Hz; 0.5% @DC, all other frequencies (0 to 100%, via output terminal)
0.7 Vrms / 1.4 Vrms (TYP)
*1
0.5 % or less 100 us (TYP) 70 % or more
0.1 V For 45 Hz to 65 Hz and DC: ±(0.5 % of reading + 0.3 V/0.6 V)For 40 Hz to 999.9 Hz: ±(0.7 % of reading + 0.9 V/1.8 V)
0.1 V For 45 Hz to 65 Hz and DC: ±(|2 % of reading| + 1 V / 2 V)
0.01 A 0.01 A For 45 Hz to 65 Hz and DC:±(0.5 % of reading+0.02 A/0.02 A); For 45 Hz to 65 Hz and DC:±(0.5 % of reading+0.04 A/0.02 A); For 40 Hz to 999.9 Hz:±(0.7 % of reading + 0.04 A / 0.04 A) For 40 Hz to 999.9 Hz:±(0.7 % of reading + 0.08 A / 0.04 A)
0.1 A 0.1 A
For 45 Hz to 65 Hz and DC:±(|2 % of reading|+0.2 A/0.1 A) For 45 Hz to 65 Hz and DC:±(|2 % of reading|+0.2 A/0.1 A)
0.1 / 1 W 0.1 / 1 W
±(2 % of reading + 0.5 W)
±(2 % of reading + 1 W)
0.1 / 1 VA 0.1 / 1 VA
±(2 % of reading + 0.5 VA) ±(2 % of reading + 1 VA)
0.1 / 1 VAR 0.1 / 1 VAR
±(2 % of reading + 0.5 VAR) ±(2 % of reading + 1 VAR)
0.000 to 1.000 0.000 to 1.000
0.001 0.001
0.00 to 50.00 0.00 to 50.00
0.01 0.01
SPECIFICATIONS
ASR-2100/ASR-2100RASR 2050/ASR-2050R-
HARMONIC VOLTAGE EFFECTIVE VALUE (RMS) PERCENT (%)
(AC-INT and 50/60 Hz only)
HARMONIC CURRENT EFFECTIVE VALUE (RMS) PERCENT (%)
(AC-INT and 50/60 Hz only)
*1. The voltage display is set to RMS in AC/AC+DC mode and AVG in DC mode. *2. AC mode: For an output voltage of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C. DC mode: For an output voltage of 25 V to 250 V / 50 V to 500 V and 23 °C ± 5 °C. *3. An output current in the range of 5 % to 100 % of the maximum current, and 23 °C ± 5 °C. *4. An output current in the range of 5 % to 100 % of the maximum peak current in AC mode, an output current in the range of 5 % to 100 % of the maximum instantaneous current in DC mode,
and 23 °C ± 5 °C. The accuracy of the peak value is for a waveform of DC or sine wave *5. For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % of the maximum current, DC or an output frequency of 45 Hz to 65 Hz, and 23 °C ± 5 °C. *6. The apparent and reactive powers are not displayed in the DC mode. *7. The reactive power is for the load with the power factor 0.5 or lower. *8. An output voltage in the range of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C.
OTHERS PROTECTIONS
DISPLAY MEMORY FUNCTION ARBITRARY WAVE
INTERFACE
Number of Memories Waveform Length Standard
Factory Optional
INSULATION RESISTANCE
Between input and chassis, output and chassis, input and output
WITHSTAND VOLTAGE
Between input and chassis, output and chassis, input and output
EMC
Safety Environment Operating Environment
Operating Temperature Range Storage Temperature Range Operating Humidity Range Storage Humidity Range Altitude
DIMENSIONS & WEIGHT
ORDERING INFORMATION
ASR-2050 ASR-2100 ASR-2050R ASR-2100R
500VA Programmable AC/DC Power Source 1000VA Programmable AC/DC Power Source 500VA Programmable AC/DC Power Source for 3U 1/2 Rack Mount 1000VA Programmable AC/DC Power Source for 3U 1/2 Rack Mount
ACCESSORIES
CD ROM(User Manual, Programming manual), Safety Guide, Power Cord, Mains Terminal Cover Set, Remote Sense Terminal Cover Set, GTL-123 Test Lead, GTL-246 USB Cable
Range Full Scale Resolution Accuracy
Range Full Scale Resolution
Accuracy
USB LAN EXT Control GPIB RS-232C
Up to 40th order of the fundamental wave Up to 40th order of the fundamental wave 175 V / 350 V, 100% 175 V / 350 V, 100%
*8
0.1 V, 0.01% 0.1 V, 0.01% Up to 20th ± (0.2 % of reading + 0.5 V / 1 V); 20th to 40th ± (0.3 % of reading + 0.5 V / 1 V)
Up to 20th ± (0.2 % of reading + 0.5 V / 1 V);
20th to 40th ± (0.3 % of reading + 0.5 V / 1 V) Up to 40th order of the fundamental wave Up to 40th order of the fundamental wave 5 A / 2.5 A, 100% 10 A / 5 A, 100%
*3
0.01 A, 0.01% 0.01 A, 0.01%
Up to 20th ± (1 % of reading + 0.1 A / 0.05 A); 20th to 40th ± (1.5 % of reading + 0.1 A / 0.05 A)
Up to 20th ± (1 % of reading + 0.2 A / 0.1 A);
20th to 40th ± (1.5 % of reading + 0.2 A / 0.1 A)
OCP, OTP, OPP, FAN Fail TFT-LCD, 4.3 inch 10 sets for Store and Recall settings 16 (nonvolatile) 4096 words Type A: Host, Type B: Slave, Speed: 1.1/2.0, USB-CDC MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask
External Signal Input; External Control I/O SCPI-1993, IEEE 488.2 compliant interface Complies with the EIA-RS-232 specifications 500 Vdc, 30 M or moreΩ
1500 Vac, 1 minute
EN 61326-1 (Class A) EN 61326-2-1/-2-2 (Class A) EN 61000-3-2 (Class A, Group 1) EN 61000-3-3 (Class A, Group 1) EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-8/-4-11 (Class A, Group 1) EN 55011 (Class A, Group1) EN 61010-1 Indoor use, Overvoltage Category II 0 °C to 40 °C
-10 °C to 70 °C 20 %rh to 80 % RH (no condensation) 90 % RH or less (no condensation) Up to 2000 m ASR-2000 : 285(W)×124(H)×480(D) (not including protrusions); Approx. 11.5 kg ASR-2000R : 213(W)×124(H)×480(D) (not including protrusions); Approx. 10.5 kg
Specifications subject to change without notice.
ASR-2000GD1BH
OPTIONAL ACCESSORIES
Opt01 : RS-232+GPIB Communication Functions(Factory installed) Opt02 : European Output Outlet only for ASR-2000(Factory installed) GET-003 GET-004 GRA-439-E GRA-439-J GTL-232
Extended Universal Power Socket(ASR-2000R only) Extended European Power Socket(ASR-2000R only) Rack Mount Kit (EIA) Rack Mount Kit (JIS) RS-232C Cable, approx. 2M
GTL-258
GPIB Cable, approx. 2M, including 25 pins Micro-D connector
ASR-001
Air inlet filter
FREE DOWNLOAD
USB Driver
Loading...