盐雾测试报告
Issue Date
2016/11/7
Salt Spray Test Report
样品名称:
Name of Sample
型号:
Model
货号:
Cat
客户:
Client
实验人:
Experimenter
授权签字人/职务:
批准日期:
Report No.
A2016110501
Drill Bit Set
AKT2120, AKT2115, AKT2126, AKT2121
6073952, 6162928, 6057961, 6206327
Argos
Hans Hou
Haydn Cui / Director of Test Center
Result: PASS details on following pages
宝时得科技(中国)有限公司检测中心
Positec TechnologyChinaCo.Ltd. Testing Center
注意事项 No.18. Dongwang Road,Suzhou Industrial Park,Suzhou,Jiangsu,China Remarks Pos:215123 Tel:0512-67631888-6305 Email:Wensheng.Ni@positecgroup.com
1.报告无检测公章无效;
This report is only valid with the seal of Positec Technology (China) Co.,Ltd. Testing Center.
2.未经检测中心书面批准,不得部分复制此报告;
This report shall not be reproduced except in full.
3.检测结果仅对所测样品负责。
The results refer only to the investigated samples.
4.对检测报告若有异议,应于收到报告之日起十五日内向本实验室提出;
If differ in opinion of this report,please notify our lab within 15days.
Page 2
检测报告
Test Report
盐雾测试报告
Salt Spray Test Report
AKT2120: 50 Piece Drill Bit Set. AKT2115: 70 Piece Drill Bit Set. AKT2126: 150 Piece Drill Bit Set. AKT2121: 246 Piece Drill Bit Set.
2016/11/5-6
Equipment number
6GA420110615
样品名称
Sample Name
厂家
Manufacturer
申请单位
Application by
申请人;
Applicant
样品图片
Photo of Samples
依据标准或技术文 件:
Reference criterion/document s
本实验使用的主要 设备:
Main Equipments of measurement used in this test
Drill Bit Set
丹阳恒友
Danyang Hengyou
Quality Dept. of
Company
姓名: 候万义 Name:Hans Hou
实验方案
Test manual
设备名称
Equipment Name
Salt Spray Test Chamber
样品型号
Sample Designation
检测数量
Amount of Samples
检测目的
Test Purpose
电话:0512-65152888 Tel:
According to test standard ISO 9227: 2012 1, The workpiece 5% (neutral) salt spray test, test temperature is 35. 2, Spray: intermittent. 3, Test time: 24h.
AKT2120 AKT2115 AKT2126 AKT2121
4PCS
Quality Improving
Test
Please refer to page below.
型号
Model
YW01-002 2017/9/18
样品参数
Specification
送样日期
Arrival date in Lab.
检测日期
Test Date
地址 : 东旺路18号 Address:18#, Dongwang Road
校准有效日期
Next Calibration
2016/11/4
设备编号
检测结果
Test Result
样品编号
Sample NO.
A2016110501-01
A2016110502-02
A2016110503-03
A2016110504-04
说明
Explanation
结论 Conclusion
编制
Compiled by
签名
Signature
报告编号 Report NO
PASS
记录
record
After 24 hours, test surface has no red phenomenon such as corrosion, bubble, crack.In addition to other suspended impurities.
After 24 hours, test surface has no red phenomenon such as corrosion, bubble, crack.In addition to other suspended impurities.
After 24 hours, test surface has no red phenomenon such as corrosion, bubble, crack.In addition to other suspended impurities.
After 24 hours, test surface has no red phenomenon such as corrosion, bubble, crack.In addition to other suspended impurities.
1, The workpiece 5% (neutral) salt spray test, test temperature is 35. 2, Spray: intermittent. 3, Test time: 24h.
According to the test from ISO 9227: 2012, The test result good based on ISO 10289:2001
Huabo Li
日期
Date
2016/11/7
审核
Inspected by
签名
Signature
Xiaohui Zhang
日期
Date
A2016110501
判定
Verdict
OK
OK
OK
OK
2016/11/7
page 1 of 2
表单号:PTC-03-035 修订日期:2016-02-25 修改状态:04
表单号:PTC-03-035 修订日期:2016-02-25 修改状态:04
Page 3
Sample Photo/s:
检测报告
Test Report
----------------------------------End of Report---------------------------------
报告编号
Report No.
表单号:PTC-03-035 修订日期:2016-02-25 修改状态:04
表单号:PTC-03-035 修订日期:2016-02-25 修改状态:04
A2016110501
page 2 of 2