Guardian EyeSafe G1200, EyeSafe G1201 Installation, Operation And Maintenance Manual

Valve Components
A
600-664R
B
600-628R
C
AP600-666
D
AP600-665
E
600-629R
F
AP600-640
G
450-005
G1200/G1201 EyeSafe™ Faucet Mounted Eyewashes
Actuating Knob (pkg of 2)
Inlet O-Ring (pkg of 2)
Valve Stem with O-Rings and Spring
Diverter with O-Rings
Neoprene Washer (pkg of 2)
Faucet Control Valve Assembly
Outlet Aerator Assembly
Parts List
B C D
A
E
F
Inlet Adapters (included with unit)
AP400-009
Additional Adapters (ordered separately)
AP400-012 AP400-015
G1200 Components
A
250-046R
B
AP450-110R
(1) 15/16”-27 Male Adapter with O-Ring, (1) 13/16”-27 Male Adapter with O-Ring, (1) 3/8” NPS Male Adapter with O-Ring
(1) 13/16”-24 Female Adapter with O-Ring
(1) 3/4” Female Hose Adapter with O-Ring
Dust Cover with Strap (pkg of 2)
Aerator Assembly (pkg of 2)
A
B
A
G1201 Components
A
250-046R
B
AP450-110R
Guardian Equipment 312 447 8100 TELEPHONE 1140 N North Branch St 312 447 8101 FACSIMILE Chicago, IL 60642 gesafety.com
Dust Cover with Strap (pkg of 2)
Aerator Assembly (pkg of 2)
B
rev. 0418 / © 2018 Guardian Equipment
Installation, Operation and Maintenance
G1200/G1201 EyeSafe™ Faucet Mounted Eyewashes
Installation
1. Remove present aerator or other fitting from faucet outlet.
2. Mount the EyeSafe™ unit to faucet spout. The EyeSafe™ inlet has a 55/64”-27 female thread.
Note: Due to the variety of faucets, it may be necessary to use an adapter to mount the EyeSafe™ unit on the
faucet spout. Three adapters are furnished with the unit; a larger adapter with 15/16”-27 thread size to fit Delta and American Standard faucets, a smaller adapter with 13/16”-27 thread size to fit Kohler and other faucets, and a 3/8” NPS adapter to fit WaterSaver faucets. Important: When mounting EyeSafe™ to faucet, be careful not to overtighten adapter.
3. If necessary, use a 13/16” or adjustable wrench to adjust the angle of the outlet heads to obtain the desired angle for the eyewash water flow.
4. Attach the enclosed sign to wall or backsplash behind sink.
Use
1. Turn on cold water side of faucet. Important: Use only cold water when EyeSafe™ unit is in operation. Hot water may cause scalding or other injury.
2. Pull knob on EyeSafe™ unit forward to activate the eyewash. Water pressure will hold the eyewash in operation, thus leaving the user’s hands free.
3. To return to normal faucet operation, push knob back to original position and activate faucet control valve.
Note: When the faucet is turned off during eyewash activation, the pull-knob will return to original position
automatically.
Maintenance
1. Periodic cleaning of the eyewash aerators is advisable to assure proper water flow.
2. Keep plastic float-off covers on outlet heads when the unit is not in use.
3. The EyeSafe™ unit, like all emergency eyewash and shower equipment, should be tested weekly.
Guardian Equipment 312 447 8100 TELEPHONE 1140 N North Branch St 312 447 8101 FACSIMILE Chicago, IL 60642 gesafety.com