USE & CARE INSTRUCTIONS

Digital

Air Cleaning System

with UV-C, True HEPA & Odor Reduction

Model No. AC5250

5-Year Limited Warranty www.guardiantechnologies.com

1.866.603.5900

REV0811

Replacement Filter No: Filter

(FLT5000, FLT5111)

To Order Contact Customer Service

1.866.603.5900 or log on to www.guardiantechnologies.com

English E - 1 French F - 1 Spanish S - 1

Date Purchased month ________

year _________

E-1

WARNINGS

This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.

Warning: The cords, wires and/or cables supplied with this product contain chemicals, including lead or lead compounds, known to the state of California to cause cancer and birth defects or other reproductive harm. Wash hands after using.

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

Read all instructions before using appliance.

IMPORTANT - This portable luminaire has a polarized plug (one blade is wider than the other) as a feature to reduce the risk of electric shock. This plug will fit into a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use an extension cord unless the plug can be fully inserted. Do not alter the plug.

To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.

Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.

To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.

Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the unit.

Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.

NEVER drop or insert any object into any openings.

DO NOT run cord under carpeting.

DO NOT cover cord with throw rugs, runners, or similar coverings.

DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

WARNINGS

DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.

Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.

DO NOT use outdoors.

NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.

DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

DO NOT place anything on top of unit.

WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

PRODUCT SPECIFICATIONS AND PARTS

MODEL NUMBER

.................... AC5250

 

REPLACEMENT FILTER

DIMENSIONS

7in W x 10.25in D x 28in H

 

FILTER C (FLT5000)

 

REPLACEMENT BULB

WEIGHT

10.55 lbs

 

 

LB5000

 

INPUT VOLTAGE

120 V 60Hz 60W, 0.5 A

 

 

 

BULB

8W

 

 

 

 

 

 

 

 

This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA. US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product.

The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model’s CADR for Dust and the electrical energy it consumes, or CADR/Watt.

E-2

E-3

PRODUCT SPECIFICATIONS AND PARTS

 

Carrying

Control Panel

Handle

 

 

Lock & Release

 

Button

Air Inlet

(for accessing

Filter and Bulb)

Air Outlet

 

Filter

 

Access

 

Cover

 

Unit Body

Base

 

Front of Unit

Back of Unit

 

CONTROL PANEL

SETTINGS

HEPA Reset

Display Screen

 

TIMER SET

FAN SPEED SELECTION

Button

Button

UV-C ON/OFF

POWER ON/OFF

Button

Button

 

 

Power Indicator

 

Light

Digital Air Cleaning System

Improve your indoor air quality with your new germguardian® Air Cleaning System. Multiple levels of cleaning include a combination True HEPA filter that captures allergens, and Charcoal filter to remove odors. UV-C light technology enhances germ-killing.

Pre-Filter*

Captures initial dust and allergen particles.

Charcoal Filter* (aka Activated Carbon)

Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs and mold.

True HEPA Filter

Captures 99.99% of dust and allergens.

UV-C Light

UV-C light technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.

*Pre-Filter and Charcoal Filter are combined into one layer that attaches to the HEPA Filter.

AIR CLEANING LAYERS

Lock & Release

Button

 

 

 

 

 

 

 

 

 

 

Combination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UV-C

 

 

 

 

Filter C

 

Rear Cover

Main Unit

 

Bulb

 

 

 

 

includes Pre,

 

with Air Inlet Grill

 

 

 

 

UV-C

 

Charcoal & True

 

 

 

 

 

 

 

 

 

 

HEPA filters

 

 

 

 

 

 

 

 

 

Metal

 

 

 

 

 

 

 

 

 

 

Shield

 

 

 

 

E-4

E-5

Installing/removing COMBINATION filter

1. Turn off and unplug the unit.

2. Press the Lock & Release

3. Remove the used

Button and remove the

 

Combination Filter (Filter C)

Rear Cover from the unit.

 

and dispose of it in

 

 

 

the garbage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.Before inserting new filter, connect two filter pieces together. Be sure the white, pleated side of each filter piece is facing the same direction, then slide the plastic tabs together and lock filter pieces in place. Your new combination filter is now ready to be inserted into air purifier.

5.Insert filter system into the unit. Consult the arrow on the filter for correct installation direction.

6. Reattach the Rear Cover of the unit and securely latch into place.

OPERATING INSTRUCTIONS

Before operating the air purifier:

1.Carefully remove your air purifier box and bag.

2.Remove rear cover, remove filter from bag, then return filter to unit.

3.Select a firm, level and flat location for the air purifier.

*For proper air flow, locate the unit at least 1 foot from any wall or furniture.

*Make sure none of the grills are blocked.

4.Plug the power cord into a 120V AC outlet.

IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.

Operating the Air purifier:

1. Turn unit power ON.

2. Select fan speed MODE 1 - 5

(1 = lowest speed setting; 5 = highest speed setting)

3. Select UV-C ON or OFF using UV-C Power Button.

4. TIMER: If you prefer to run the purifier for a specific number of hours, you can select between 1 and 8 hours on the display.

*Filter Replacement Indicator: The HEPA reset light on the control panel will illuminate indicating that it is time to replace your filter. Replace the filter according to directions (E-7) then insert pen tip into HEPA Reset area on control panel to restart the system. Depending on usage, filter will last approximately 6 months. See “Cleaning & Maintaining Filter (E-11) for proper care of filter.

E-7

E-6

Guardian AC5250, AC5250PT User Manual

Installing & Removing UV-C Bulb

1. Remove the Rear

2. After removing

3. After removing the

Cover of the unit

the Rear Cover

Combination Filter,

by pushing Lock &

from the unit,

use a Philips head

Release Button.

remove the

screwdriver to

 

Combination Filter.

remove four (4)

 

 

screws and detach

 

 

the UV-C Metal

 

 

Shield.

4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit. (Fig. 4).

until the UV-C METAL SHIELD has been removed.

FIG. 4

TWIST BULB 1/4 Turn TO REMOVE.

Replacement bulb: LB5000 available at 866.603.5900 or www.guardiantechnologies.com

5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit. .

Cleaning & Maintaining

the combination Filter

The air purifier should be cleaned at least once every month and the outer Pre-/

Charcoal Filter attached to the HEPA Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions.

PRE-/CHARCOAL FILTER

Remove the Pre-/Charcoal Filter from the velcro strips on the True HEPA Filter. (Fig. 6) Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt. After cleaning, reattach the Pre-/Charcoal Filter to the True HEPA Filter.

TRUE HEPA FILTER

Remove the Combination Filter from the back of unit. Remove the Pre-/Charcoal Filter to expose the HEPA Filter.

When the HEPA Filter turns from white to grey or black it should be replaced with a new one. If the HEPA Filter is still white, it does NOT need to be replaced.

IMPORTANT: Do NOT try to wash and re-use the Combination Filter. Please contact Customer Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement filter.

Replacement filter: FILTER C (FLT5000 or FLT5111)

NOTE: The Combination Filter is one filter system. The multiple layers include: the Pre-/Charcoal Filter and the True HEPA Filter.

AIR PURIFIER

Use a clean, dry, soft cloth to wipe the external surface of the unit.

E-8

E-9

Clean Air Delivery Rate

From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.

This air cleaner is suggested for use in a single, closed room up to 193 square feet.

Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much more effective in rooms when all the doors and windows are closed.

TOBACCO SMOKE: 125+

This value represents performance that can be expected within the first 72 hours of operation. Subsequent use may vary with use.

Tested per ANSI/AHAM AC-1 National Standard

What is CADR?

CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particules from things like tobacco smoke and plant pollens from the room.

NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.

CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product.

NEVER use alcohol or other solvents.

troubleshooting guide

PROBLEM

SOLUTION

Unit does not operate.

Check that the unit is plugged in.

 

Call Customer Service 1.866.603.5900.

Unit shuts off unexpectedly.

Check that the unit is plugged into a working

 

electrical outlet.

 

Check that the HEPA Filter is firmly in place.

 

Check that the Rear Cover is latched firmly in place.

 

Call Customer Service 1.866.603.5900.

No air circulating from unit.

Unplug unit. Check Pre-/Charcoal and HEPA Filters.

 

Clean Pre-/Charcoal Filter if necessary.

 

Replace HEPA Filter if necessary.

Increase in noise level.

Make sure the filters are clean. Replace if necessary.

limited warranty

To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. Save your original sales receipt to validate start of warranty period.

If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. The complete machine must be delivered pre-paid to any authorized Guardian Technologies LLC warranty service center. Please include complete information on the problem, date of purchase, copy of original sales receipt and your name, address and telephone number. If you are not near a warranty service center, call the factory for assistance in the US and Canada at 1.866.603.5900.

The warranty does not include unusual wear, damage resulting from accident, or unreasonable use of the product. This warranty does not cover unauthorized repairs. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.). Use only Guardian Technologies replacement parts.

We consider the registration process important to ensuring superior service to our customers, however submitting this card to Guardian Technologies LLC is optional and does not affect your rights to utilize this warranty according to the conditions stated above. If you have any questions or comments about your product call toll free at 1.866.603.5900 or send comments to:

ATTN Customer Service Guardian Technologies LLC 7700 St Clair Avenue Mentor, Ohio 44060

This warranty can be registered online at www.guardiantechnologies.com.

 

Guardian Technologies LLC

 

 

7700 St Clair Avenue | Mentor, Ohio 44060

 

E-10

1.866.603.5900 | www.guardiantechnologies.com

E-11

Loading...
+ 14 hidden pages