Guardian AC5000 User Manual [en, es, fr]

USE & CARE INSTRUCTIONS
Guardian Technologies LLC
26251 Bluestone Blvd. | Euclid, Ohio 44132
1.866.603.5900 | www.guardiantechnologies.com
Air Cleaning System
with UV-C, True HEPA & Odor Reduction
Model No. AC4825/AC5000
www.guardiantechnologies.com
1.866.603.5900
REV0914
Replacement Filter/AC4825 22” Model: Filter (FLT4825) Replacement Filter/AC5000 28” Model: Filter (FLT5000)
To Order Contact Customer Service
1.866.603.5900 or log on to www.guardiantechnologies.com
B C
English E - 1 French F - 1 Spanish S - 1
Date Purchased
month ________ year _________
E-1
READ AND SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNINGS
Failure to comply with the warnings listed below may
result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
WARNING: THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USING.
(CALIFORNIA CODE OF REGULATIONS PROPOSITION 65)
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
• Read all instructions before using appliance.
• IMPORTANT - This appliance has a polarized plug (one blade is wider than the other). To reduce
the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
• To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
• Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs,
near heat registers, radiator, stoves or heaters.
• To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
• Children cannot recognize the hazards associated with the usage of electrical appliances. For
this reason, always supervise children when they are near the unit.
• Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or
whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
• NEVER drop or insert any object into any openings.
• DO NOT run cord under carpeting.
• DO NOT cover cord with throw rugs, runners, or similar coverings.
• DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and
where it will not be tripped over.
• DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after
the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer
Service at 1.866.603.5900 for assistance.
• Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
• DO NOT use outdoors.
• DO NOT place anything on top of unit.
WARNINGS
Failure to comply with the warnings listed below may
result in electric shock or serious injury.
• NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
• DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
• WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/ccleanup
1-866-284-4010
This product earned the ENERGY STAR by meeting strict energy efficiency guidelines
set by the US EPA. US EPA does not endorse any manufacturer claims of healthier
indoor air from the use of this product.
The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between
the model’s CADR for Dust and the electrical energy it consumes, or CADR/Watt.
PRODUCT SPECIFICATIONS
MODEL NUMBER SERIES: AC4825 DIMENSIONS: 10.25”L x 6.75”W x 21.5”H WEIGHT: 8.65 pounds INPUT VOLTAGE: 120 V, 60Hz, 55W, 0.5 Amps REPLACEMENT FILTER: Filter B (FLT4825) REPLACEMENT BULB: LB4000 BULB: 4W WARRANTY: 3-Year Limited Warranty
MODEL NUMBER SERIES: AC5000 DIMENSIONS: 11”L x 6.75”W x 27.25”H WEIGHT: 10.95 pounds INPUT VOLTAGE: 120 V, 60Hz, 60W, 0.5 Amps REPLACEMENT FILTER: Filter C (FLT5000) REPLACEMENT BULB: LB5000 BULB: 8W WARRANTY: 5-Year Limited Warranty
E-2 E-3
Control Panel
PRODUCT PARTS
Carrying Handle
AIR CLEANING SYSTEM
Improve your indoor air quality with your new Germ Guardian® Air Cleaning System. Multiple levels of cleaning include a combination True HEPA filter that captures allergens, and Charcoal filter to remove odors. UV-C light technology enhances germ-killing.
PRE-FILTER*
Captures initial dust and allergen particles.
Air Outlet
Base
Air Inlet
Unit Body
FRONT OF UNIT BACK OF UNIT
CONTROL PANEL
UV-C Bulb Button/
Power Knob
HEPA/UV Bulb Reset
Lock & Release Button
(for accessing Filter and Bulb)
Filter Access Cover
CHARCOAL FILTER*
Contributes to the control and prevention of the growth of bacteria, germs and mold.
TRUE HEPA FILTER
Captures 99.99% of dust and allergens.
UV-C LIGHT
UV-C light technology works with filters to enhance the elimination of airborne germs Titanium Dioxide is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
*Pre-Filter and Charcoal Filter are combined into one layer that attaches to the HEPA Filter.
AIR CLEANING LAYERS
AC4825 SERIES
Lock & Release Button
UV-C Bulb
UV-C Metal Shield
Power Indicator/ Change Filter Indicator
Main Unit
Combination Filter B
includes Pre/ Charcoal & True HEPA filters
Rear Cover
with Air Inlet Grill
E-5E-4
AIR CLEANING LAYERS
INSTALLING & REMOVING COMBINATION FILTER
AC5000 SERIES
Main Unit
OPERATING INSTRUCTIONS
UV-C Bulb
UV-C Metal Shield
Combination Filter C
includes Pre/ Charcoal & True HEPA filters
Lock & Release Button
Rear Cover
with Air Inlet Grill
CHANGE FILTER INDICATOR
The green power light on the air cleaner will turn red and flash continuously indicating that it is time to replace the filter. Replace the filter according to the directions then press the UV control button and hold for 3 seconds to restart the system. The light will turn back to green. Depending on usage, filter will last approximately 6 months.
REPLACE FILTER
1. Turn off and unplug
the unit.
2. Press the Lock & Release
Button and remove the Rear Cover from the unit.
3. Remove the used Combination Filter.
4. Insert new Combination Filter into the unit. Consult the arrow on the filter for correct installation direction.
BEFORE OPERATING THE AIR PURIFIER:
1. Carefully remove your air purifier from box and bag.
2. Select a firm, level and flat location for the air purifier. * For proper air flow, locate the unit at least 1 foot from any wall or furniture. * Make sure none of the grills are blocked.
3. Plug the power cord into a 120V AC outlet.
IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.
5. Reattach the Rear Cover of the unit and securely latch into place.
6. Push and hold UV Control Button for 3 seconds to reset Filter Change Indicator.
OPERATING THE AIR PURIFIER:
1. Turn the air purifier ON by rotating POWER KNOB clockwise.
2. Upon turning the air purifier ON, the power indicator will be lit (green) and the unit will be in LOW mode ( ).
3. Rotate the POWER KNOB clockwise to set the air purifier to MEDIUM ( ) or High mode ( ).
4. To activate the UV-C Bulb, press the UV button. Press the button again to turn OFF the UV-C Bulb.
5. To turn the unit OFF, rotate the POWER KNOB counter-clockwise to OFF mode (•).
E-6 E-7
Check out our on-line Filter Reminder and Replacement program.
www.guardiantechnologies.com
CLEANING & MAINTAINING
AC4825 SERIES
THE COMBINATION FILTER
The air purifier should be cleaned at least once every month and the outer Pre-/Charcoal Filter attached to the HEPA Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions.
PRE-/CHARCOAL FILTER
Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt.
Filter Package includes:
1-Piece True HEPA Filter 1-Piece Pre-/Charcoal Filter
Filter lasts approximately 6-8 months depending on use
TRUE HEPA FILTER
Remove the Combination Filter from the back of unit. Remove the Pre-/Charcoal Filter to expose the HEPA filter. When the HEPA Filter turns from white to grey or black it should be replaced with a new one. If the HEPA filter is still white, it does NOT need to be replaced.
Create ONE COMPLETE COMBINATION FILTER
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
This air cleaner is suggested for use in a single, closed room up to 155 square feet.
Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much more effective in rooms when all the doors and windows are closed.
TOBACCO SMOKE: 100+ AC4825
This value represents performance that can be expected within the first 72 hours of operation. Subsequent use may vary with use.
Tested per ANSI/AHAM AC-1 National Standard
AC5000 SERIES
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
This air cleaner is suggested for use in a single, closed room up to 193 square feet.
Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much more effective in rooms when all the doors and windows are closed.
TOBACCO SMOKE: 125+ AC5000
This value represents performance that can be expected within the first 72 hours of operation. Subsequent use may vary with use.
Tested per ANSI/AHAM AC-1 National Standard
IMPORTANT: Do NOT try to wash and re-use the Combination Filter. Please contact Customer
Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement filter.
What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particules from things like tobacco smoke and plant pollens from the room.
AC4825 Series Replacement Filter FILTER B (FLT4825) AC5000 Series Replacement Filter FILTER C (FLT5000)
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit. CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in
NOTE: The Combination Filter is one filter system. The multiple layers include: the
Pre-/Charcoal Filter and the True HEPA Filter.
the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.
AIR PURIFIER
Use a clean, dry, soft cloth to wipe the external surface of the unit.
E-8 E-9
INSTALLING & REMOVING UV-C BULB
INSTALLING & REMOVING UV-C BULB
CHANGE BULB INDICATOR
The blue light on the front of air cleaner will begin to flash continuously when it is time to replace the UV-C bulb. Replace the bulb according to the directions then press the UV control button and hold for 3 seconds to restart the system. The light should remain a constant blue.
REPLACE BULB
Continue reading below for remaining instructions on how to Install & Remove the UV-C Bulb for the AC4825 Series and the AC5000 Series.
1. Remove the Rear Cover of the unit by pushing Lock & Release Button.
2. After removing the Rear Cover from the unit, remove the Combination Filter.
AC4825 SERIES
AC5000 SERIES
TWIST BULB 1/4 TURN TO REMOVE BULB
3. After removing the
Combination Filter, use a Philips head screwdriver to remove four (4) screws and detach the UV-C Metal Shield.
5. The UV-C Bulb is reinstalled by reversing the process in Step 4.
6. Push and hold UV Control Button for 3 seconds to reset UV Bulb Change Indicator.
REPLACEMENT BULB: LB5000
AVAILABLE AT 866.603.5900 OR WWW.GUARDIANTECHNOLOGIES.COM
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and twisting the bulb 1/4 turn. Remove from unit.
Bulb is NOT visible until the UV-C METAL SHIELD has been removed.
IMPORTANT: The UV-C Bulb should be replaced every 10 - 12 months depending on use.
Please contact Customer Service at 1.866.603.5900 or visit us at
PULL UV-C BULB STRAIGHT OUT OF UNIT
Bulb is NOT visible until the UV-C METAL SHIELD
3. After removing the Combination Filter, use a Philips head screwdriver to remove two (2) screws and detach the UV-C Metal Shield.
5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.
6. Push and hold UV Control Button for 3 seconds to reset UV Bulb Change Indicator.
REPLACEMENT BULB: LB4000
AVAILABLE AT 866.603.5900 OR WWW.GUARDIANTECHNOLOGIES.COM
E-10 E-11
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit.
has been removed.
www.guardiantechnologies.com to purchase a replacement bulb.
Loading...
+ 14 hidden pages