This product should be used only in accordance with the specications outlined
in this manual. Usage other than what has been specied here may result in
serious injury.
WARNING: THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS, KNOWN
TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR
OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USING.
When using electrical appliances, basic precautions should always be followed to
reduce the risk of re, electric shock and injury to persons, including the following:
Read all instructions before using appliance.•
IMPORTANT - This portable luminaire has a polarized plug (one blade is wider than the other) •
as a feature to reduce the risk of electric shock. This plug will t into a polarized outlet only one
way. If the plug does not t fully in the outlet, reverse the plug. If it still does not t, contact a
qualied electrician. Never use an extension cord unless the plug can be fully inserted. Do not
alter the plug.
To avoid re or shock hazard, plug the appliance directly into a 120V AC electrical outlet.•
Keep the cord out of heavy trafc areas. To avoid re hazard, NEVER put the cord under rugs, •
near heat registers, radiator, stoves or heaters.
To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use •
near water.
Children cannot recognize the hazards associated with the usage of electrical appliances. For •
this reason, always supervise children when they are near the unit.
Always unplug the complete air cleansing system (CACS) before moving it, opening the grill, •
changing lters, cleaning or whenever the air purier is not in use. Be sure to pull by the plug
and not the cord.
NEVER drop or insert any object into any openings.•
WARNINGS
DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, •
after the appliance malfunctions, or if it has been dropped or damaged in any manner.
Call Customer Service at 1.866.603.5900 for assistance.
Use appliance only for intended household use as described in this manual. Any other •
use not recommended by the manufacturer may cause re, electric shock or injury to
persons.
DO NOT use outdoors.•
NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or •
sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. •
Doing so will void your warranty. The inside of the unit contains no user serviceable
parts. All servicing should be performed by qualied personnel only.
DO NOT place anything on top of unit.•
We strongly urge you to use UV resistant goggles or glasses when operating and using •
this device. Protective goggles are available at your local home improvement store.
PRODUCT SPECIFICATIONS AND PARTS
MODEL NUMBER .................... AC5000
DIMENSIONS ........................... 7in W x 10.25in D x 28in H
INPUT VOLTAGE ..................... 120 V 60Hz 0.5A, 58W
REPLACEMENT FILTER
FLT5000
REPLACEMENT BULB
LB5000
BULB........... 8W
E-3E-2
PRODUCT SPECIFICATIONS AND PARTS
Control Panel
Air Outlet
Base
Front of Unit
Carrying
Handle
Air Inlet
Unit Body
Back of Unit
Lock & Release
Button
(for accessing
Filter and Bulb)
Filter
Access
Cover
COMBINATION FILTER
Photocatalyst
and Charcoal
Filter
Pre-Filter
True HEPA Filter
The above illustration shows the multiple ltration layers of the CombinationFilter to
demonstrate the different ltration layers it contains:
1. PRE-FILTER
2. TRUE HEPA FILTER
3. PHOTOCATALYST/
CHARCOAL FILTER
E-4
Power Knob
CONTROL PANEL
UV-C Bulb Switch
Power Indicator
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer
to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit lters the air.
This air cleaner is suggested for use in a single, closed room up to 186 square feet.
Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much
more effective in rooms when all the doors and windows are closed.
TOBACCO SMOKE: 120
This value represents performance that can be expected within the rst 72 hours of operation. Subsequent use may vary with use.
Tested per ANSI/AHAM AC-1 National Standard
What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of ltered air delivered
by an air purier. CADR ratings show the effectiveness of how efcient the air purier is at
capturing ne particules from things like tobacco smoke and plant pollens from the room.
E-5
UV-C and True HEPA
Complete Air Cleansing System (CACS)
INSTALLING & REMOVING FILTER
Improve your indoor air quality with your new Germ Guardian® UV-C and True HEPA
Complete Air Cleansing System. Multiple levels of cleaning include a combination
True HEPA lter that captures allergens, Photocatalyst lter and Charcoal lter to
remove odors. UV-C light technology enhances germ-killing.
Pre-Filter
Captures initial dust and allergen particles.
True HEPA Filter
Captures 99.99% of dust and allergens.
Photocatalyst and Charcoal Filter
Contributes to the control and prevention of the growth of bacteria, germs and mold.
UV-C Light
UV-C light technology works with lters to enhance the elimination of airborne germs
OPERATING INSTRUCTIONS
BEFORE OPERATING THE CACS:
1. Carefully remove your CACS from box and bag.
2. Select a rm, level and at location for the CACS.
* For proper air ow, locate the unit at least 1 foot from any wall or furniture.
* Make sure none of the grills are blocked.
3. Plug the power cord into a 120V AC outlet.
Combination
Filter
includes HEPA,
Charcoal &
Photocatalyst lters
Main Unit
UV-C
Bulb
Bulb
Cover
INSTALLING/REMOVING HEPA FILTER
1. Turn off and unplug the unit.
Lock & Release
Button
Rear Cover
with Air Inlet Grill
IMPORTANT: When moving the CACS, always lift unit by the carrying handle located on back.
OPERATING THE CACS:
1. Turn the CACS ON by rotating POWER KNOB clockwise.
2. Upon turning the CACS ON, the power indicator will be lit and the unit will be in
LOW mode ( ).
3. Rotate the POWER KNOB clockwise further to set the CACS to MEDIUM mode ( ).
4. Continue to rotate the POWER KNOB clockwise to set the CACS to HIGH mode ( ).
5. To activate the UV-C Bulb, press the UV button. Press the button again to turn OFF the
UV-C Bulb.
6. To turn the unit OFF, rotate the POWER KNOB counter-clockwise to OFF mode (•).
E-6
2. Press the Lock & Release
Button and remove the
Rear Cover from the unit.
5. Reattach the Rear Cover of the unit and securely latch into place.
3. Remove the used
Combination Filter and
dispose of it in the
garbage.
4. Insert new Combination
Filter into the unit. Consult
the arrow on the lter for
correct installation direction.
E-7
INSTALLING & REMOVING UV-C BULB
INSTALLING & REMOVING UV-C BULB
INSTALLING & REMOVING UV-C BULB
1. Remove the Rear Cover of the unit by pushing Lock & Release Button (Fig. 1).
FIG. 1
2. After removing the Rear Cover from the unit, remove the Combination Filter (Fig. 2).
4. The UV-C Bulb is removed by rotating it one quarter turn and then sliding it out of the
top and bottom lamp sockets (Fig. 4).
TWIST BULB
Bulb is NOT visible
until the BULB COVER
has been removed.
FIG. 4
1/4 TURN TO
REMOVE.
4. The UV-C Bulb is reinstalled by sliding it into the top and bottom lamp sockets and
rotating it one quarter turn (Fig. 5).
FIG. 2
3. After removing the Combination Filter, use a Philips head screwdriver to remove four (4)
screws and detach the Bulb Cover (Fig. 3).
E-8
FIG. 3
TWIST BULB
1/4 TURN TO
REINSTALL.
FIG. 5
IMPORTANT: The UV-C Bulb should be replaced every 10 - 12 months depending on use.
Please contact Germ Guardian Customer Service at 1.866.603.5900 or visit us at
www.germguardian.com to purchase a replacement bulb.
Replacement UV-C Bulb: LB5000.
E-9
CLEANING & MAINTAINING
TROUBLESHOOTING GUIDE
THE COMBINATION FILTER
The CACS should be cleaned at least once every month and the outer Pre-Filter
attached to the Combination Filter should be cleaned every month. More
frequent cleaning may be required depending on environmental conditions.
PRE-FILTER
Remove the Pre-Filter from the velcro strips on the Combination Filter. (Fig. 6)
Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt.
After cleaning, reattach the Pre-Filter to the Combination Filter.
FIG. 6
HEPA FILTER
Remove the Combination Filter from the back of unit.
Remove the Pre-Filter to expose the HEPA Filter.
When the HEPA Filter turns from white to grey or black it should be replaced with a
new one. If the HEPA Filter is still white, it does NOT need to be replaced.
IMPORTANT: Do NOT try to wash and re-use the Combination Filter. Please contact Germ
Guardian Customer Service at 1.866.603.5900 or visit us at www.germguardian.com to
purchase a replacement lter.
Replacement lter: FLT5000.
NOTE: The Combination Filter is one lter. The multiple layers include: the HEPA Filter,
Charcoal Filter and Photocatalyst Filter.
COMPLETE AIR CLEANSING SYSTEM
Use a clean, dry, soft cloth to wipe the external surface of the unit.
PROBLEMSOLUTION
Unit does not operate.Check that the unit is plugged in.
Call Customer Service 1.866.603.5900.
Unit shuts off unexpectedly.Check that the unit is plugged into a working
electrical outlet.
Check that the HEPA Filter is rmly in place.
Check that the Rear Cover is latched rmly in place.
Call Customer Service 1.866.603.5900.
No air circulating from unit.Unplug unit. Check Charcoal, Photocatalyst and HEPA
Filters.
Clean Charcoal Filter if necessary.
Replace HEPA Filter if necessary.
Increase in noise level.Make sure the lters are clean. Replace if necessary.
LIMITED WARRANTY
To the consumer, Guardian Technologies LLC warrants this product to be free of defects in
materials or workmanship commencing upon the date of the original purchase. Save your
original sales receipt to validate start of warranty period.
If this product should become defective within the warranty period, we will repair or replace
any defective parts free of charge. The complete machine must be delivered pre-paid to any
authorized Guardian Technologies LLC warranty service center. Please include complete
information on the problem, date of purchase, copy of original sales receipt and your name,
address and telephone number. If you are not near a warranty service center, call the factory
for assistance in the US and Canada at 1.866.603.5900.
The warranty does not include unusual wear, damage resulting from accident, or unreasonable
use of the product. This warranty does not cover unauthorized repairs. This warranty gives you
specic legal rights and you may also have other rights (other rights may vary from state to state
in the U.S.A.). Use only Germ Guardian replacement parts.
We consider the registration process important to ensuring superior service to our customers,
however submitting this card to Guardian Technologies LLC is optional and does not affect your
rights to utilize this warranty according to the conditions stated above. If you have any questions
or comments about your product call toll free at 1.866.603.5900 or send comments to:
ATTN Customer Service
Guardian Technologies LLC
7700 St Clair Avenue
Mentor, Ohio 44060
This warranty can also be registered online at www.germguardian.com.
NOTE: Do NOT stick any foreign objects or your ngers inside of the unit.
CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on
and/or in the unit while cleaning as they will damage the product. NEVER
use alcohol or other solvents.
E-10
Guardian Technologies LLC
7700 St Clair Avenue | Mentor, Ohio 44060
1.866.603.5900 | www.germguardian.com
E-11
Additional Products Available
UV-C Room Air Sanitizer
Model No. EV9102
from Germ Guardian
UV-C SANITIZERS
Pluggable UV-C Air Sanitizer
Model No. GG1000
®
UV-C Sanitizer Wand
Model No. LW18
UV-C Mini Sanitizer Wand
Model No. LW9
HEAT SANITIZERS
®
Nursery Sanitizer
Model No. NS2000
Toothbrush Sanitizer
Model No. TS3000
OTHER HEALTHY HOME PRODUCTS
Dry Heat
Table Top Fan
Model No. F1000
AIR CLEANSING SYSTEMS
®
Table Top Complete
Air Cleansing System
Model No. AC4000
Complete Air Cleansing System
Model No. AC6000
Touchless
Soap + Sanitizer
Dispenser
Model No. SD1000
Loading...
+ 15 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.