USE & CARE INSTRUCTIONS
Table Top Multi-Layer
Air Puri er
Model No. AC4010
1-Year Limited Warranty
www.germguardian.com
1.866.603.5900
REV0810
Replacement Filter No: FLT4010
To Order Contact Customer Service
1.866.603.5900 or log on to www.germguardian.com
English E - 1
French F - 1
Spanish S - 1
Date Purchased
month ________
year _________
E-1
INTRODUCTION
Thank you for purchasing the Germ Guardian®
Table Top Multi-Layer Air Purier.
PLEASE READ AND SAVE THESE INSTRUCTIONS.
Filter
Filter Door
SAFETY PRECAUTIONS
Please read the following precautions carefully before operating the Table Top
Multi-Layer Air Purier. Failure to do so could result in a re hazard, electrical
shock, bodily injury or damage to the unit.
WARNING: THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS
PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS,
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH
DEFECTS OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USING.
Do not damage, pull, twist, bend or place heavy objects on the electrical cord.•
Never handle the electrical cord with wet hands.•
Do not alter the plug in any way.•
Do not use with extension cords.•
Never tug on the electrical cord to unplug the unit from the outlet.•
Unplug the unit before cleaning, installing or replacing lters.•
If the electrical cord becomes damaged, please contact a qualied •
technician for repair.
Do not place ngers or foreign objects into the airow openings of the unit.•
Operate the unit in a well-ventilated area.•
Do not operate unit with any power supply other than the one provided.•
Do not operate the unit outdoors.•
Do not operate the unit near ammable gases.•
Do not operate the unit in humid or wet places such as a bathroom.•
Do not use chemical sprays near the unit, they will accumulate on the lter •
and potentially cause harmful fumes.
Do not operate the unit in an area with a high oil content, such as mechanical •
oil or cooking oil, over time it will deteriorate the lter.
Never look directly at the UV-light bulb when lit.•
Make sure all lters are correctly installed before running the unit.•
This is not a toy and is not intended for use by children. For adult use only.•
Children cannot recognize the hazards associated with the usage of electrical •
appliances. For this reason, always supervise children when they are near the unit.
Do not defeat interlock switch.•
Power/Speed Knob
Vent
Safety
Switch
UV Bulb
8. Power Supply
Modication not approved by the party responsible for compliance could void user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on; the user is encouraged to try to correct the interference by one or more of
the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and the receiver.
3. Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
E-2 E-3
INSTALLATION
The lter can be found packaged inside the Air Purier. It is recommended
to replace the lter every six months to maintain optimal performance.
Replacement lter model number is FLT4010.
Installing the Filter
1. Unplug the air purier from the electrical outlet.
2. Lift to release the lter cover.
3. Gently pull lter from unit (*and
remove bag from the lter if the
unit is new).
INSTALLATION
Features: The lter is an all-in-one multi-stage lter.
Layers of air cleaning include:
1. Charcoal removes odors and smoke.
2. HEPA captures 99.97% of airborne dust and allergens.
3. PCO captures and dissolves airborne allergens and mold.
4. UV-light bulb works with lter to kill germs.
Cleaning the Unit
WARNING: To avoid serious injury from electric shock, the
unit must be turned OFF and unplugged from the power outlet
prior to any cleaning.
1. TURN THE UNIT OFF AND UNPLUG THE UNIT FROM THE
POWER OUTLET.
2. Clean unit with a soft, damp cloth only. DO NOT pour or splash
water on the unit or use any abrasive type cleaner. Clean all
external surfaces, especially the air intake grills and air outlet.
3. Reposition the unit, plug power cord into power outlet
and turn ON.
TROUBLESHOOTING GUIDE
4. Replace lter into compartment.
Make sure the dark gray side
faces up towards you.
5. To install new lter reverse steps 1-4.
Do NOT insert lter with
white pleated side facing up.
Dark gray side should
always face upwards.
PROBLEM SOLUTION
Unit doesn't operate.
No air circulating from unit.
Increase in noise level.
Filter door does not
close properly.
Check that unit is plugged in.
Check Safety Switch: Remove lter. Check
small metal safety switch. Switch cannot be
bent inside the unit.
Call Customer Service at 1.866.603.5900.
Unplug unit: Check lter and
remove bag before rst use.
Make sure lter is clean.
Replace. Unplug unit: Open
bottom, remove lters and
make sure fan is clear.
Check that the installation of the
lter is correct.