GSI PNEG-566 User Manual

PNEG-733
Top Dry Systems
PNEG-
'DWH--11
6SHFLILFDWLRQV
SHIPPING INFORMATION
All LTL shipments incur a 5% handling charge on net,
(maximum up to $75.00).
All UPS shipments under $100.00 incur a $9.00 charge.
TOPDRY
April 4, 2011
2
TOPDRY
Table of Contents
Warranty ........................................................ Page 4
Specications and Drying Rates..................................... Page 5
Bin Specications (U.S. & Metric Measurements) ......................... Page 6
Batch Series Drying Rates (U.S. Measurements) ......................... Page 7
Autoow Series Drying Rates (U.S. Measurements) . . . . . . . . . . . . . . . . . . . . . . . Page 8
Batch Series Drying Rates (Metric Measurements) ........................ Page 9
Autoow Series Drying Rates (Metric Measurements)..................... Page 10
Capacity Conversions...............................................Page 11
Price Lists and Weights........................................... Page 12
Grain Drying Systems (Batch) ....................................... Page 13
Grain Drying Systems (Autoow) ..................................... Page 14
Controls .....................................................Pages 15-16
Duct Packages with Stairs and Ladders..............................Page 17-18
Aeration Floors .................................................Page 19-20
Series 2000 Fan/Heater Units .....................................Page 21-22
Roof Vents ...................................................... Page 23
Entrance Sheets.................................................. Page 24
Aeration Systems ...............................................Page 24-25
Accessories ..................................................... Page 26
Unloading Equipment ............................................Page 27-30
Quoting Information and Quote Forms .............................. Page 31
Miscellaneous Cost Recommendations ................................ Page 31
Comparisons .................................................... Page 32
Batch Quoting..................................................Page 33-34
Autoow Quoting ...............................................Page 35-36
Necessary Information for Quoting.................................... Page 37
Autoow Conversion Price Lists and Weights ......................Page 38-41
April 4, 2011
3
9101239_1_CR_rev7.DOC (revised July 2009)
Limited Warranty
The GSI Group, LLC. (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, whichever is earlier. The end­user’s sole remedy (and GSI’s only obligation) is to repair or replace, at GSI’s option and expense, products that in GSI’s judgment, contain a material defect in materials or workmanship. Expenses incurred by or on behalf of the end-user without prior written authorization from the GSI Warranty Group shall be the sole responsibility of the end-user.
Warranty Extensions: The Limited Warranty period is extended for the following products:
Product Warranty Period
AP Fans and Flooring
Performer Series Direct Drive Fan Motor
3 Years
All Fiberglass Housings Lifetime All Fiberglass Propellers Lifetime
Cumberland Feeding/Watering Systems
Feeder System Pan Assemblies 5 Years ** Feed Tubes (1.75" & 2.00") 10 Years * Centerless Augers 10 Years * Watering Nipples 10 Years *
Grain Systems
Grain Bin Structural Design 5 Years
Grain Systems Farm Fans Zimmerman
Portable & Tower Dryers 2 Years Portable & Tower Dryer Frames and Internal Infrastructure †
5 Years
GSI further warrants that the portable and tower dryer frame and basket, excluding all auger and auger drive components, shall be free from defects in materials for a period of time beginning on the twelfth (12
th
)
month from the date of purchase and continuing until the sixtieth (60
th
) month from the date of purchase (extended warranty period). During the extended warranty period, GSI will replace the frame or basket components that prove to be defective under normal conditions of use without charge, excluding the labor, transportation, and/or shipping costs incurred in the performance of this extended warranty.
* Warranty prorated from list price: 0 to 3 years – no cost to end-user 3 to 5 years – end-user pays 25% 5 to 7 years – end-user pays 50% 7 to 10 years – end user pays 75%
** Warranty prorated from list price: 0 to 3 years – no cost to end-user 3 to 5 years – end-user pays 50%
† Motors, burner components and moving parts not included. Portable Dryer screens included. Tower Dryer screens not included.
Conditions and Limitations:
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE. SPECIFICALLY, GSI MAKES NO FURTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE IN CONNECTION WITH: (i) PRODUCT MANUFACTURED OR SOLD BY GSI OR (ii) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT, REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY FOR A PARTICULAR PURPOSE, OR DESIGN OF SUCH PRODUCTS.
GSI shall not be liable for any direct, indirect, incidental or consequential damages, including, without limitation, loss of anticipated profits or benefits. The sole and exclusive remedy is set forth in the Limited Warranty, which shall not exceed the amount paid for the product purchased. This warranty is not transferable and applies only to the original end-user. GSI shall have no obligation or responsibility for any representations or warranties made by or on behalf of any dealer, agent or distributor.
GSI assumes no responsibility for claims resulting from construction defects or unauthorized modifications to products which it manufactured. Modifications to products not specifically delineated in the manual accompanying the equipment at initial sale will void the Limited Warranty.
This Limited Warranty shall not extend to products or parts which have been damaged by negligent use, misuse, alteration, accident or which have been improperly/inadequately maintained. This Limited Warranty extends solely to products manufactured by GSI.
Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the location and installation of products manufactured or sold by GSI.
Limited Warranty
TOPDRY
April 4, 2011
4
TOPDRY
Specications & Drying Rates
April 4, 2011
5
U.S Measurements (Shelled Corn)
TOPDRY
Bin
Diameter
Batch Autoow
Batch Size
(BU)
Grain in Process
(BU)
Dump Size
(BU)
Rings
Eave
Height
Peak
Height
Batch Autoow
Maximum
Storage
(BU)
Maximum
Storage
(BU)
5 18’-5” 25’-0” 4,813 4,373 6 22’-1” 28’-8” 6,198 5,758
24’ 1,000 560 187
7 25’-9” 32’-4” 7,583 7,143 8 29’-5” 36’-0” 8,968 8,528 9 33’-1” 39’-8” 10,353 9,913
10 36’-9” 43’-4” 11,738 11,298
5 18’-5” 26’-9” 7,459 6,804
6 22’-1” 30’-5” 9,623 8,968 7 25’-9” 34’-1” 11,787 11,132
30’ 1,500 845 282
8 29’-5” 37’-9” 13,951 13,296
9 33’-1” 41’-5” 16,115 15,460 10 36’-9” 45’-1” 18,279 17,624 11 40’-5” 48’-9” 20,443 19,788
6 22’-1” 32’-6” 13,859 12,914
7 25’-9” 36’-2” 16,974 16,029
36’ 2,160 1,215 405
8 29’-5” 39’-10” 20,089 19,144
9 33’-1” 43’-6” 23,204 22,259 10 36’-9” 47’-2” 26,319 25,374 11 40’-5” 50’-10” 29,434 28,489
Note: Maximum storage is estimated with 12” aeration oor, level to bottom of fan entrance, with upper batch lled.
Metric Measurements (Shelled Corn)
Batch Autoow
Bin
Diameter
Batch Size
(MT)
Grain in Process
(MT)
Dump Size
(MT)
Rings
Eave
Height
Peak
Height
5 5.61 m 7.62 m 122.25 111.07
6 6.73 m 8.74 m 157.43 146.25
7.32 m (24’)
25.4 14.22 4.75
7 7.85 m 9.86 m 192.61 181.43 8 8.97 m 10.97 m 227.79 216.61 9 10.08 m 12.09 m 262.97 251.79
10 11.20 m 13.21 m 298.15 286.97
5 5.61 m 8.15 m 189.46 172.82 6 6.73 m 9.27 m 244.42 227.79
9.14 m (30’)
38.1 21.46 7.16
7 7.85 m 10.39 m 299.39 282.75 8 8.97 m 11.51 m 354.36 337.72
9 10.08 m 12.62 m 409.32 392.68 10 11.20 m 13.74 m 464.28 447.65 11 12.32 m 14.86 m 519.25 502.61
6 6.73 m 9.91 m 352.02 328.02
7 7.85 m 11.02 m 431.14 407.14
10.97 m (36’)
54.86 30.86 10.29
8 8.97 m 12.14 m 510.26 486.26
9 10.08 m 13.26 m 589.38 565..38 10 11.20 m 14.38 m 668.50 644.50 11 12.32 m 15.49 m 747.63 723.62
Note: Maximum storage is estimated with 12” aeration oor, level to bottom of fan entrance, with upper batch lled.
April 4, 2011
6
Prices and Specications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com
Batch Autoow
Maximum
Storage
(MT)
Maximum
Storage
(MT)
TOPDRY
Batch Series 24’ Dia. 1-Fan 30’ Dia. 1-Fan 30’ Dia. 2-Fan 36’ Dia. 1-Fan 36’ Dia. 2-Fan
Fan &
Heater
Unit(s)
15 H.P.
36” Fan
3.5
Million
BTU
15 H.P.
40” Fan
6.25
Million
BTU
Plenum
Temper-
ature F°
140
160
180
140
160
180
Batch Series - Shelled Corn
(U.S. Measurements)
Moisture
Content
Bu/Hr
Wet Basis
20% 398 2.5 4.61 3.3 728 1.9 521 4.1 841 2.6
25% 252 3.8 292 5.1 461 3.3 330 6.5 533 4.0
30% 157 6.1 182 8.2 288 5.2 206 10.4 333 6.5
20% 474 2.0 550 2.8 869 1.8 622 3.4 1004 2.1
25% 300 3.2 348 4.4 550 2.7 394 5.4 636 3.4
30% 178 5.2 218 6.8 344 4.4 246 8.7 397 5.4
20% 607 1.6 677* 2.4* 1,112 1.4 694* 3.4* 1,284 1.6
25% 384 2.6 429* 3.7* 704 2.1 440* 5.2* 814 2.7
30% 240 4.0 268* 6.0* 440 3.4 274* 8.3* 508 4.2
20% 486 2.0 562 2.7 650 3.3 1,022 2.1
25% 308 3.1 356 4.2 411 5.2 647 3.3
30% 192 4.9 222 6.7 257 8.4 404 5.3
20% 580 1.6 670 2.2 775 2.8 1,219 1.8
25% 367 2.6 425 3.5 491 4.4 772 2.8
30% 230 4.2 265 5.6 306 7.1 482 4.5
20% 742 1.3 858 1.8 890* 2.6* 1,560 1.4
25% 470 2.0 543 2.7 564* 4.1* 988 2.2
30% 294 3.3 339 4.4 352* 6.5* 617 3.5
Batch
Time
Hours
Bu/Hr
Batch
Time
Hours
Bu/Hr
Batch
Time
Hours
Bu/Hr
Batch
Time
Hours
Bu/Hr
Batch
Time
Hours
20% 638 2.4 717 2.9 1,142 1.9
140
30 H.P.
Fan
10.25
Million
BTU
40 H.P.
42” Fan
10.25
Million
BTU
* Insufcient burner BTUs for 45 deg. ambient temp rating exclude loading time.
160
180
140
160
180
25% 405 3.6 454 4.7 723 2.9
30% 253 5.9 284 7.5 452 4.7
20% 762 2.0 856 2.5 1,363 1.5
25% 482 3.1 542 4.0 863 2.5
30% 302 4.9 338 6.4 539 4.0
20% 975 1.5 1,095 2.0 1,744 1.3
25% 618 2.4 694 3.1 1,105 2.0
30% 386 3.9 433 4.9 690 3.2
20% 726 2.1 810 2.7
25% 460 3.3 513 4.2
30% 287 5.2 320 6.7
20% 867 1.8 966 2.2
25% 549 2.7 612 3.5
30% 343 4.4 382 5.6
20% 1,110 1.4 1,236 1.8
25% 702 2.1 783 2.7
30% 439 3.4 489 4.4
Est. at temp 45 deg. F, rel. humidity 65% Use only as a guide, conditions will vary capacities.
1/3 CFM/bu
cooling rate
Prices and Specications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com
April 4, 2011
7
Fan &
Heater
Unit(s)
15 H.P.
36” Fan
3.5
Million
BTU
15 H.P.
40” Fan
6.25
Million
BTU
TOPDRY
Autoow Series - Shelled Corn
(U.S. Measurements)
Autoow Series 24’ Dia. 1-Fan 30’ Dia. 1-Fan 30’ Dia. 2-Fan 36’ Dia. 1-Fan 36’ Dia. 2-Fan
Plenum Temper­ature F°
160
180
200
160
180
200
Moisture
Content
Wet Basis
Bu/Hr
Dump
Interval
Min
Bu/Hr
Dump
Interval
Min
Bu/Hr
Dump
Interval
Min
Bu/Hr
Dump
Interval
Min
Bu/Hr
20% 528 21.6 557 31.9 939 18.9 993 25.8
25% 334 34.1 353 50.4 595 29.9 629 40.7
30% 209 54.6 220 80.8 371 47.9 393 65.2
20% 675* 16.8* 713* 24.9* 1,202 14.8 1,271 20.1
25% 428* 26.6* 451* 39.4* 761 23.4 805 31.8
30% 267* 42.6* 282* 63.1* 475 37.4 503 51.0
20% 791* 14.4* 835* 21.3* 1,407* 12.6* 1,488* 17.2*
25% 501* 22.7* 529* 33.6* 891* 19.9* 943* 27.2*
30% 313* 36.4* 330* 53.9* 557* 32.0* 589* 43.5*
20% 648 17.5 711 25.0 1,154 15.4 1,269 20.2
25% 411 27.7 450 39.5 731 24.3 803 31.9
30% 256 44.4 281 63.3 457 39.0 502 51.1
20% 830* 13.7* 909* 19.5* 1,477 12.0 1,623 15.8
25% 525* 21.6* 576* 30.9* 936 19.0 1,028 24.9
30% 328* 34.7* 360* 49.5* 584 30.4 642 39.9
20% 971* 11.7* 1,065* 16.7* 1,730* 10.2* 1,901* 13.4*
25% 615* 18.5* 674* 26.4* 1,096* 16.2* 1,204* 21.3*
30% 384* 29.6* 421* 42.2* 684* 26.0* 752* 34.1*
Dump
Interval
Min
20% 740 15.4 806 22.0 819 31.3 1,452 17.6
160
30 H.P.
42” Fan
10.25
Million
BTU
40 H.P.
42” Fan
10.25
Million
BTU
* Insufcient burner BTUs for 45 deg. ambient temp rating exclude loading time.
180
200
160
180
200
25% 469 24.3 511 34.8 519 49.4 920 27.8
30% 293 38.9 319 55.8 324 79.1 574 44.6
20% 947 12.0 1,032 17.2 1,048 24.4 1,858 13.8
25% 600 19.0 653 27.2 664 38.6 1,177 21.7
30% 375 30.4 408 43.6 415 61.8 735 34.8
20% 1,109 10.2 1,208 14.7 1,227 20.8 2,176 11.7
25% 702 16.2 765 23.2 777 32.9 1,378 18.6
30% 439 25.9 478 37.2 486 52.8 861 29.8
20% 920 19.3 950 26.9
25% 583 30.5 602 42.6
30% 364 48.9 376 68.2
20% 1,178 15.1 1,216 21.0
25% 746 23.8 770 33.3
30% 466 38.2 481 53.3
20% 1,379 12.9 1,424 18.0
25% 873 20.3 902 28.4
30% 545 32.6 563 45.5
Est. at temp 45 deg. F, rel. humidity 65% Use only as a guide, conditions will vary capacities.
1/3 CFM/bu
cooling rate
April 4, 2011 8
Prices and Specications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com
TOPDRY
Batch Series - Shelled Corn
(Metric Measurements)
Fan &
Heater
Unit(s)
11.19 kW
91.44 cm
1.125
Million
kCal
11.19 kW
101.6 cm
1.125
Million
kCal
Batch Series
Plenum
Temper-
ature C°
60
71
82
140
160
180
7.32m Dia. 1-Fan
Moisture
Content
Bu/Hr
Wet Basis
20% 10.1 2.5 11.7 3.3 18.5 1.9 13.2 4.1 21.4 2.6
25% 6.4 3.8 7.4 5.1 11.7 3.3 8.2 6.5 13.5 4.0
30% 4.0 6.1 4.6 8.2 7.2 5.2 5.2 10.4 8.5 6.5
20% 12.0 2.0 14.0 2.8 22.1 1.8 15.8 3.4 25.5 2.1
25% 7.6 3.2 8.8 4.4 14.0 2.7 10.0 5.4 16.2 3.4
30% 4.8 5.2 5.5 6.8 8.7 4.4 6.2 8.7 10.1 5.4
20% 15.4 1.6 17.2 2.4* 28.2 1.4 17.6 3.4* 32.6 1.6
25% 9.8 2.6 10.9 3.7* 17.9 2.1 11.2 5.2* 20.7 2.7
30% 6.1 4.0 6.8 6.0* 11.2 3.4 7.0 8.3* 12.9 4.2
20% 12.3 2.0 14.3 2.4 16.5 3.3 25.9 2.1
25% 7.8 3.1 9.0 4.2 10.4 5.2 16.4 3.3
30% 4.9 4.9 5.6 6.7 6.5 8.4 10.3 5.3
20% 14.7 1.6 17.0 2.2 19.7 2.8 31.0 1.8
25% 9.3 2.6 10.8 3.5 12.5 4.4 19.6 2.8
30% 5.8 4.2 6.7 5.6 7.8 7.1 12.3 4.5
20% 18.9 1.3 21.8 1.8 22.6* 2.6* 39.6 1.4
25% 11.9 2.0 13.8 2.7 14.3* 4.1* 25.1 2.2
30% 7.5 3.3 8.6 4.4 8.9* 6.5* 15.7 3.5
Batch
Time
Hours
9.14m Dia. 1-Fan
Bu/Hr
Batch
Time
Hours
9.14m Dia. 2-Fan
Bu/Hr
Batch
Time
Hours
10.97 Dia.
1-Fan
Bu/Hr
Batch
Time
Hours
10.97 Dia.
Bu/Hr
2-Fan
Batch
Time
Hours
20% 16.2 2.4 18.2 2.9 29.0 1.9
140
22.37 kW
106.6 cm
1.125
Million
kCal
29.83 kW
106.6 cm
2.5
Million
kCal
* Insufcient burner BTUs for 45 deg. ambient temp rating exclude loading time.
160
180
140
160
180
25% 10.3 3.6 11.5 4.7 18.4 2.9
30% 6.4 5.9 7.2 7.5 11.5 4.7
20% 19.4 2.0 21.7 2.5 34.6 1.5
25% 12.3 3.1 13.8 4.0 21.9 2.5
30% 7.7 4.9 8.6 6.4 13.7 4.0
20% 24.8 1.5 27.2 2.0 44.3 1.3
25% 15.7 2.4 17.6 3.1 28.1 2.0
30% 9.8 3.9 11.0 4.9 17.5 3.2
20% 18.5 2.1 20.6 2.7
25% 11.7 3.3 13.0 4.2
30% 7.3 5.2 8.1 6.7
20% 22.0 1.8 24.5 2.2
25% 13.9 2.7 15.5 3.5
30% 8.7 4.4 9.7 5.6
20% 28.2 1.4 31.4 1.8
25% 17.8 2.1 19.9 2.7
30% 11.2 3.4 12.4 4.4
Est. at temp 45 deg. F, rel. humidity 65% Use only as a guide, conditions will vary capacities.
1/3 CFM/bu
cooling rate
Prices and Specications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com
April 4, 2011
9
Autoow Series - Shelled Corn
(Metric Measurements)
TOPDRY
Fan &
Heater
Unit(s)
11.19 kW
91.44 cm
1.125
Million
kCal
11.19 kW
101.6 cm
1.125
Million
kCal
Autoow Series
Plenum Temper­ature C°
60
71
82
140
160
180
Wet Basis
7.32m Dia. 1-Fan
Moisture
Content
Bu/Hr
Dump
Interval
Min
20% 13.4 21.6 14.1 31.9 23.9 18.9 25.2 25.8
25% 8.5 34.1 9.0 50.4 15.1 29.9 16.0 40.7
30% 5.3 54.6 5.6 80.8 9.4 47.9 10.0 65.2
20% 17.1 16.8* 18.1 24.9* 30.5 14.8 32.3 20.1
25% 10.9 26.6* 11.5 39.4* 19.3 23.4 20.4 31.8
30% 6.8 42.6* 7.2 63.1* 12.1 37.4 12.8 51.0
20% 20.1 14.4* 21.2 21.3* 35.7 12.6* 37.8 17.2*
25% 12.7 22.7* 13.4 33.6* 22.6 19.9* 24.0 27.2*
30% 8.0 36.4* 8.4 53.9* 14.1 32.0* 15.0 43.5*
20% 16.5 17.5 18.1 25.0 29.3 15.4 32.2 20.2
25% 10.4 27.7 11.4 39.5 18.6 24.3 20.4 31.9
30% 6.5 44.4 7.1 63.3 11.6 39.0 12.8 51.1
20% 21.1* 13.7* 23.1* 19.5* 37.5 12.0 41.2 15.8
25% 13.3* 21.6* 14.6* 30.9* 23.8 19.0 26.1 24.9
30% 8.3* 34.7* 9.1* 49.5* 17.8 30.4 16.3 39.9
20% 24.7* 11.7* 27.1* 16.7* 43.9* 10.2* 48.3* 13.4*
25% 15.6* 18.5* 17.1* 26.4* 27.8* 16.2* 30.6* 21.3*
30% 9.8* 29.6* 10.7* 42.2* 17.4* 26.0* 19.1* 34.1*
9.14m Dia. 1-Fan
Bu/Hr
Batch
Time
Hours
9.14 Dia. 2-Fan
Batch
Bu/Hr
Time
Hours
10.97 Dia.
1-Fan
Bu/Hr
Batch
Time
Hours
10.97m Dia. 2-Fan
Bu/Hr
Batch
Time
Hours
20% 18.8 15.4 20.5 22.0 20.8 31.3 36.9 17.6
140
22.37 kW
106.6 cm
1.125
Million
kCal
29.83 kW
106.6 cm
2.5
Million
kCal
* Insufcient burner BTUs for 45 deg. ambient temp rating exclude loading time.
160
180
140
160
180
25% 11.9 24.3 13.0 34.8 13.2 49.4 23.4 27.8
30% 7.4 38.9 8.1 55.8 8.2 79.1 14.6 44.6
20% 21.1 12.0 26.2 17.2 26.6 24.4 47.2 13.8
25% 15.2 19.0 16.6 27.2 16.9 38.6 29.9 21.7
30% 9.5 30.4 10.4 43.6 10.5 61.8 18.7 34.8
20% 28.2 10.2 30.7 14.7 31.2 20.8 55.3 11.7
25% 17.8 16.2 19.4 23.2 19.7 32.9 35.0 18.6
30% 11.2 25.9 12.1 37.2 12.3 52.8 21.9 29.8
20% 23.4 19.3 24.1 26.9
25% 14.8 30.5 15.3 42.6
30% 9.2 48.9 9.6 68.2
20% 29.9 15.1 30.9 21.0
25% 18.9 23.8 19.6 33.3
30% 11.8 38.2 12.2 53.3
20% 35.0 12.9 36.2 18.0
25% 22.2 20.3 36.2 18.0
30% 13.8 32.6 14.3 45.5
Est. at temp 45 deg. F, rel. humidity 65% Use only as a guide, conditions will vary capacities.
1/3 CFM/bu
cooling rate
April 4, 2011 10
Prices and Specications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com
TOPDRY
Conversion Rates
(All Series)
Crop
(Common Types)
Canola 140° F (corn dry time) x 1.60 (corn drying capacity) x 0.60
Corn 180° F dry time given in specs. drying capacity given in specs.
White Corn 140° F (corn dry time) x 1.45 (corn drying capacity) x 0.45
Milo / Sorghum 140° F (corn dry time) x 1.60 (corn drying capacity) x 0.60
Soybean 150° F (corn dry time) x 1.55 (corn drying capacity) x 0.55
Sunower 140° F (corn dry time) x 0.75 (corn drying capacity) x 1.75
Wheat 160° F (corn dry time) x 1.60 (corn drying capacity) x 0.60
Plenum Temperature
Recommended
Crop
(Common Types)
Canola 1 Metric Ton (@ 56 lb / bu) = 39 bu
Conversion Formula (time)
New Production Rate
Conversion to Metric Tons
Conversion from bushels to Metric Tons
Conversion Formula (bu)
New Production Rate
Corn 1 Metric Ton (@ 56 lb / bu) = 39 bu
White Corn 1 Metric Ton (@ 56 lb / bu) = 39 bu
Milo / Sorghum 1 Metric Ton (@ 56 lb / bu) = 39 bu
Soybean 1 Metric Ton (@ 60 lb / bu) = 36.75 bu
Sunower 1 Metric Ton (@ 32 lb / bu) = 68.9 bu
Wheat 1 Metric Ton (@ 60 lb / bu) = 36.75 bu
April 4, 2011
11
Loading...