Chapter 1 Safety ..................................................................................................................................................4
Safety Guidelines ............................................................................................................................... 4
Safety Instructions .............................................................................................................................. 5
Chapter 2 Recommended Method for Full Floor Installation ..........................................................................7
Fan Placement Diagram ..................................................................................................................... 7
Grain Systems Recommended Method for Full Floor Installation ...................................................... 8
Chapter 3 Grandstand Identification ...............................................................................................................10
20 Gauge Grandstand Identification ................................................................................................. 10
Chapter 4 Flashing Installation ........................................................................................................................11
Grain Systems Formed Flashing Installation .................................................................................... 11
Chapter 5 Grandstand Layout at Center Well for Recirculating System .....................................................12
Chapter 6 33' Cut-Lok/Cor-Lok Plank Order ...................................................................................................13
Chapter 7 33' Grandstand Layout for Recirculating System ........................................................................14
33' 20 Gauge Grandstand Layout for Recirculating
System Cut-Lok or 18 Gauge Cor-Lok Floors .................................................................................. 14
Chapter 8 33' Grandstand Layouts, 33' Maximum Wall Height .....................................................................15
33' Cor-Lok/Cut-Lok and 20 Gauge Grandstand Layout
2.66" Corrugated Bins 5 Rings and 6 Rings
4.00" Corrugated Bins 4 Rings ......................................................................................................... 15
33' Cor-Lok/Cut-Lok and 20 Gauge Grandstand Layout
2.66" Corrugated Bins 7 Rings and 4.00" Corrugated Bins 5 Rings ................................................ 16
33' Cor-Lok/Cut-Lok and 20 Gauge Grandstand Layout
2.66" Corrugated Bins 8 Rings and 4.00" Corrugated Bins 6 Rings ................................................ 17
33' Cor-Lok/Cut-Lok and 20 Gauge Grandstand Layout
2.66" Corrugated Bins 9 Rings ......................................................................................................... 18
33' Cor-Lok/Cut-Lok and 20 Gauge Grandstand Layout
2.66" Corrugated Bins 10 Rings and 4.00" Corrugated Bins 7 Rings .............................................. 19
33' Cor-Lok/Cut-Lok and 20 Gauge Grandstand Layout
2.66" Corrugated Bins 11 Rings and 4.00" Corrugated Bins 8 Rings .............................................. 20
33' Cor-Lok/Cut-Lok and 20 Gauge Grandstand Layout
2.66" Corrugated Bins 12 Rings and 4.00" Corrugated Bins 9 Rings .............................................. 21
Chapter 9 20 Gauge Floor Support Requirements .........................................................................................22
20 Gauge Grandstand Chart - 2.66" Corrugation ............. ... ... .... ... ... ....................................... ... ... ... 22
20 Gauge Grandstand Chart - 4.00" Corrugation ............. ... ... .... ... ... ....................................... ... ... ... 23
Chapter 10 Flashing Support at Stiffeners .....................................................................................................24
Stiffener Flashing Support Instructions for Internal Universal Stiffeners ........................................ 24
Chapter 11 Air Flow Support Instructions ......................................................................................................25
Installation of Air Flow Supports .................................................................................................. ... 25
Chapter 12 Warranty ......................................................................................................................................... 31
SEE PAGE 22 AND PAGE 23 FOR 20 GAUGE
FLOOR SUPPORT REQUIREMENTS.

1. Safety

Safety Guidelines
This manual contains information that is important for you, the owner/operator, to know and understand. This information relates to protecting personal safety and preventing equipment problems. It is the responsibility of the owner/operator to inform anyone operating or working in the area of this eq uipment of these safety guidelines. To help you recognize this information, we use the symbols that are defined below. Please read the manual and pay attention to these sections. Failure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
NOTE indicates information about the equipment that you should pay special attention.
4 PNEG-219 33' Cor-Lok and Cut-Lok Flooring
1. Safety
Safety Instructions
Our foremost concern is your safety and the safety of others associated with this equipment. We want to keep you as a customer. This manual is to help you understand safe operating proced ures and some problems which may be encountered by the operator and other personnel.
As owner and/or operator, it is your responsibility to know what requirements, hazards and precautions exist, and to inform all personnel associated with the equipment or in the area. Safety precautions may be required from the personnel. Avoid any alterations to the equipment. Such alterations may produce a very dangerous situation where SERIOUS INJURY or DEATH may occur.
This equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.
Follow Safety Instructions
Carefully read all safety messages in this manual and safety signs on your machine. Keep signs in good condition. Replace missing or damaged safety signs. Be sure new equipment components and repair parts include the current safety signs. Replacement safety signs are available from the manufacturer.
Learn how to operate the machine and how to use controls properly. Do not let anyone operate without instruction.
Keep your machinery in proper working condition. Unauthorized modifications to the machine may impair the function and/or safety and affect machine life.
If you do not understand any part of this manual or need assistance, contact your dealer.
Rotating Flight
Grain augers can kill or dismember. Keep clear of all augers and never enter the bin unless all
power is disconnected and locked out. Failure to do so will result in serious injury or death.
Read and Understand Manual
Rotating Flight
PNEG-219 33' Cor-Lok and Cut-Lok Flooring 5
1. Safety
Prepare for Emergencies
Be prepared if fire starts. Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance service,
hospital and fire department near your telephone.
Wear Protective Clothing
Wear close fitting clothing and safety equipment appropriate to the job.
Keep Emergency Equipment Quickly Accessible
Eye Protection
Remove all jewelry.
Long hair should be tied up and back.
Safety glasses should be worn at all times to protect eyes from debris.
Wear gloves to protect your hands from sharp edges on plastic or steel parts.
Wear steel toe boots to help protect your feet from falling debris. Tuck in any loose or dangling shoe strings.
A respirator may be needed to prevent breathing potentially toxic fumes and dust.
Wear hard hat to help protect your head.
Gloves
Steel Toe Boots
Respirator
Hard Hat
6 PNEG-219 33' Cor-Lok and Cut-Lok Flooring

2. Recommended Method for Full Floor Installation

Fan Placement Diagram
For uniform air flow, place the fans in relation to the unloading tube as shown in Figure 2A. Floor planks should be perpendicular to the unloading tube.
Figure 2A
PNEG-219 33' Cor-Lok and Cut-Lok Flooring 7
2. Recommended Method for Full Floor Installation
Grain Systems Recommended Method for Full Floor Installation
Using the GSI recommended method for full floor installation should save construction time and eliminate the problem of improper installation which could invalidate your warranty. Note the following dimensions as shown in Figure 2B.
Dimension “A” is the leg-to-leg spacing along the centerline of a given plank.
Dimension “B” is the amount of stagger between supports under adjacent planks and is half of Dimension “A”.
Dimension “C” is the distance from the center of the unload auger to the nearest rows of supports and is half of Dimension “B”.
Dimensions “A”, “B” and “C” are shown on the appropriate grandstand layout for wall heights under 32 feet. For taller bins, grandstand quantity as well as dimensions “A” and “B” are given on Page 22 and
Page 23 for 20 gauge.
1. Layout centerlines of tank. Make sure one centerline is in line with the direction of the flooring planks while the other centerline is perpendicular with the flooring planks. See Figure 2B.
2. From the centerline that is perpendicular to the flooring planks, measure the distance of “C” Dimension and mark a chalk line. See Figure 2B.
3. From the line chalked in the previous step, measure over the distance of “B” Dimension and chalk another line. Repeat this procedure across the bin until reaching the wall in both dire ctions. When completed, there should be a set of parallel lines (perpendicular to the floor planks) with “B” Dimension distance between each line. See Figure 2B.
Chalked lines referred to Step 2
Figure 2B
8 PNEG-219 33' Cor-Lok and Cut-Lok Flooring
2. Recommended Method for Full Floor Installation
IMPORTANT: First piece of flooring must start at the
proper distance from centerline of bin. Refer to floor layout on Page 13. First piece may need to be trimmed for length to fit at the proper location.
Figure 2C
4. Install flooring starting at the bin wall on the opposite side of the unload auger. Floor planks should be placed perpendicular to the unload auger with the outside edge the correct distance from the center of the bin. bin wall and the open channel edge is facing towards the center of the bin.
(See Figure 6A on Page 13.)
Be sure the flat edge of the floor plank is facing the
(See Figure 2C.)
Position the supports for the first/shortest floor plank according to the number of bin rings and corrugation as shown in the illustrations the flashing to flooring and bin wall to hold plank in place. (
on Pages 14-21
or stated in the charts on
See Page 11
Page 22 and Page 23
for flashing installation.)
. Attach
5. POSITION THE NEXT ROW OF SUPPORTS ACCORDING TO THE CHALK LINES and support
layout. The straight tab should “snap” under the first (previous) floor piece. After the support s in the row are correctly positioned, install the next floor piece by hooking the open channel edge under the outside hooks of the floor supports. Push down sharply on the edge of the floor piece until it snaps into the previous floor piece. (See Figure 2C.) Continue this p rocess for the rest of th e floor cutting planks for center and intermediate wells as needed. See Figure 5A on Page 12 for center well support locations.
NOTE: Whenever there is more than Dimension B divided by three inches (B/3") of plank unsupported
beside the bin wall, there should be a support on that plank or a support on each of the planks adjacent to it such that no more than Dimension B divided by three inches (B/3") is unsupported. For example: 2.66" bin with 8 rings has a “B” dimension of 22". Take 22"/3" = 7.33" (Round to 7"). Therefore, there should be no more than 7" of unsupported floor plank.
PNEG-219 33' Cor-Lok and Cut-Lok Flooring 9

3. Grandstand Identification

20 Gauge Grandstand Identification
20 Gauge
Plenum Clearance Grandstand Color Code
11-7/8" Blue 14-3/8" White
17-3/16" Yellow
Figure 3A
10 PNEG-219 33' Cor-Lok and Cut-Lok Flooring