PNEG-1810 Bin Manager Temperature Cable Support Bracket Instr uc tio ns3
1. Introduction
READ THIS MANUAL carefully to learn how to properly use and install equipment. Failure to do so could
result in personal injury or equipment damage.
INSPECT the shipment immediately upon arrival. The customer is responsible for ensuring that all
quantities are correct. The customer should report and note any damage or shortage on the bill of
lading to justify their claim to the transport company.
THIS MANUAL SHOULD BE CONSIDERED a permanent part of your equipment and should be easily
accessible when needed.
This warranty provides you the assurance that the company will back its products when defects appear
within the warranty period. In some circumstances, the company also provides field improvements, often
without charge to the customer, even if the product is out of warranty. Should the equipment be abused,
or modified to change its performance beyond the factory specifications, the warranty will become void
and field improvements may be denied.
4PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
2. Safety
DANGER
WARNING
CAUTION
NOTICE
This is the safety alert symbol. It is used to alert you
to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible
injury or death.
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION, used with the safety alert symbol, indicates a
hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE is used to address practices not related to
personal injury.
DANGER indicates a hazardous situation which, if not
avoided, will result in death or serious injury.
Safety Guidelines
This manual contains information that is important for you, the owner/operator, to know and understand.
This information relates to protecting personal safety and preventing equipment problems. It is the
responsibility of the owner/operator to inform anyone operating or working in the area of this equipment
of these safety guidelines. To help you recognize this information, we use the symbols that are defined
below. Please read the manual and pay attention to these sections. Failure to read this manual and its
safety instructions is a misuse of the equipment and may lead to serious injury or death.
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions5
2. Safety
This product has sharp edges, which may cause serious injury. To avoid injury, handle
sharp edges with caution and always use proper protective clothing and equipment.
General Safety Statement
Our foremost concern is your safety and the safety of others associated with grain handling equipment.
This manual is to help you understand safe operating procedures and some problems that may be
encountered by the operator and other personnel.
As owner and/or operator, you are responsible to know what requirements, hazards, and precautions
exist, and inform all personnel associated with the equipment or in the area. Safety precautions may be
required from the personnel. Avoid any alterations to the equipment, which may produce a very dangerous
situation, where SERIOUS INJURY or DEATH may occur.
You should consider the location of the bin site relative to power line locations or electrical transmission
equipment. Contact your local power company to review your installation plan or for information
concerning required equipment clearance. Clearance of portable equipment that may be taken to the bin
site should also be reviewed and considered. Any electrical control equipment in contact with the bin
should be properly grounded and installed in accordance with National Electric Code provisions and other
local or national codes.
This product is intended for the use of grain storage only. Any other use is a misuse of the product.
Sidewall bundles or sheets must be stored in a safe manner. The safest method of storing sidewall
bundles is laying horizontally with the arch of the sheet upward, like a dome. Sidewall sheets stored on
edge must be secured so that they cannot fall over and cause injury. Use care when handling and moving
sidewall bundles.
Personnel operating or working around equipment should read this manual. This manual must be
delivered with equipment to its owner. Failure to read this manual and its safety instructions is a misuse
of the equipment.
6PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
2. Safety
Follow Safety Instructions
Carefully read all safety messages in this manual and
safety signs on your machine. Keep signs in good
condition. Replace missing or damaged safety signs. Be
sure new equipment components and repair parts include
the current safety signs. Replacement safety signs are
available from the manufacturer.
Learn how to operate the machine and how to use controls
properly. Do not let anyone operate without instruction.
Keep your machinery in proper working condition.
Unauthorized modifications to the machine may impair
the function and/or safety and affect machine life.
If you do not understand any part of this manual or need
assistance, contact your dealer.
Read and Understand Manual
Practice Safe Maintenance
Understand service procedures before doing work. Keep area
clean and dry.
Never lubricate, service, or adjust machine while it is in operation.
Keep hands, feet, and clothing away from rotating parts.
Keep all parts in good condition and properly installed. Fix
damage immediately . Replace worn or broken p arts. Remove any
built-up grease, oil, and debris.
Maintain Equipment
and Work Area
Safety Instructions
Our foremost concern is your safety and the safety of others associated with this equipment. We want to
keep you as a customer. This manual is to help you understand safe operating procedures and some
problems that may be encountered by the operator and other personnel.
As owner and/or operator, it is your responsibility to know what requirements, hazards, and precautions
exist, and to inform all personnel associated with the equipment or in the area. Safety precautions may be
required from the personnel. Avoid any alterations to the equipment. Such alterations may produce a very
dangerous situation where SERIOUS INJURY or DEATH may occur.
This equipment shall be installed in accordance with the current installation codes and applicable
regulations, which should be carefully followed in all cases. Authorities having jurisdiction should be
consulted before installations are made.
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions7
2. Safety
Prepare for Emergencies
Be prepared if fire starts.
Keep a first aid kit and fire extinguisher handy.
Keep emergency numbers for doctors, ambulance service,
hospital, and fire department near your telephone.
Keep Emergency Equipment
Quickly Accessible
Wear Protective Clothing
Wear close-fitting clothing and safety equipment appropriate
to the job.
Remove all jewelry.
Tie long hair up and back.
Wear safety glasses at all times to protect eyes from debris.
Wear gloves to protect your hands from sharp edges on
plastic or steel parts.
Wear steel-toed boots to help protect your feet from falling
debris. Tuck in any loose or dangling shoestrings.
A respirator may be needed to prevent breathing potentially
toxic fumes and dust.
Wear a hard hat to help protect your head.
Wear appropriate fall protection equipment when working at
elevations greater than six feet (6').
Eye Protection
Gloves
Steel-Toed Boots
Respirator
Hard Hat
Fall Protection
8PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
3. Decals
The manufacturer does not warrant any roof damage caused by excessive vacuum or internal
pressure from fans or other air moving systems. Adequate ventilation and/or “makeup air” devices
should be provided for all powered air handling systems. The manufacturer does n ot recommend
the use of downward flow systems (suction). Severe roof damage can result fro m any blockage of
air passages. Running fans during high humidity/cold weather conditions can cause air exhaust
or intake ports to freeze.
CAUTION!
Excessive vacuum (or pressure) may
damage roof. Use positive aeration
system. Make sure all roof vents are
open and unobstructed. Start roof
fans when supply fans are started.
Do not operate when conditions exist
that may cause roof vent icing.
DC-969
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions9
3. Decals
Rotating flighting will
kill or dismember.
Flowing material will
trap and suffocate.
Crusted material will
collapse and suffocate.
Keep clear of all augers.
DO NOT ENTER this bin!
Failure to heed these
warnings will result in
serious injury or death.
If you must enter the bin:
1. Shut off and lock out all power.
2. Use a safety harness and safety line.
3. Station another person outside the bin.
4. Avoid the center of the bin.
5. Wear proper breathing equipment or respirator.
DC-GBC-1A
ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring,
24" porthole door cover and roof manway cover. If a decal has been damaged or is missing in any of these
locations, contact the manufacturer for a free replacement decal.
GSI Decals
1004 E. Illinois St.
Assumption, IL. 62510
Phone: 1-217-226-4421
10PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
3. Decals
ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring,
24" porthole door cover and roof manway cover. If a decal has been damaged or is missing in any of these
locations, contact the manufacturer for a free replacement decal.
GSI Decals
1004 E. Illinois St.
Assumption, IL. 62510
Phone: 1-217-226-4421
WARNING
DON’T
DO
UNLOADING INSTRUCTIONS:
1. Use CENTER FLOOR OUTLET ONLY until NO grain
remains above this outlet.
2. Side floor outlets to be used ONLY when above
condition is satisfied.
3. Lock all side floor outlets to avoid accidental
premature use.
4. See manufacturers instructions for proper use of
factory supplied sidedraw (wall) discharge systems.
Failure to heed these warnings
could result in serious injury, death,
structural damage or collapse of tank.
DC-GBC-2A
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions11
4. Temperature cable location
18'-30' Temperature Cable Locations
Figure 4A
12PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
33'-36' Temperature Cable Locations
4. Temperature cable location
Figure 4B
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions13
4. Temperature cable location
39'-42' Temperature Cable Locations
Figure 4C
14PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
48' Temperature Cable Locations
4. Temperature cable location
Figure 4D
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions15
4. Temperature cable location
54'-60' Temperature Cable Locations
Figure 4E
16PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
5. Temperature cable support packages for eave height of less than or equal to 40' 5"
Eave Heights of Less than or Equal to 40' 5"
1. All 18' through 42' packages shall span one roof panel.
2. A rafter support system will be necessary for temperature cable installation in farm tanks 18' through
42' in diameters that have eave height less than 40' 4".
3. All packages include hanging angles and a cable support channel.
4. Each set of rafters should carry only one temperature cable.
5. If it is desired to support the cable from the flange of the support channel, it will be necessary to
reinforce the flange with a 12" section of 3" x 3" x 3/16" angle.
6. No more than one cable should be supported from a pair of roof panels.
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions17
5. Temperature cable support packages for eave height of less than or equal to 40' 5"
Table 1
Temperature Cable Package Part #
BMGR-1800-EF
BMGR-2124-EF
BMGR-2730-EF
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 19.
18'-30' Temperature Cable Support Assembly for Farm Roofs with
Eave Heights of 40' 5" or Less
18PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
Figure 5A
5. Temperature cable support packages for eave height of less than or equal to 40' 5"
Table 2
DiameterRoof Support Channel Part #
18'CRP-4694
21'-24'CRP-4693
27'-30'CRP-4989
Table 4
T emperature Cable Packages Part #
BMGR-1800-IF
BMGR-2124-IF
BMGR-2730-IF
Table 3
DiameterRafter Location
18'
Align 1st Hole in Top of Rafter with 2nd Roof Rib Hole
21'
Align 1
st
Hole in Top of Rafter with 2nd Roof Rib Hole
24'
Align 1st Hole in Top of Rafter with 3rd Roof Rib Hole
27'
Align 1
st
Hole in Top of Rafter with 2nd Roof Rib Hole
30'
Align 1st Hole in Top of Rafter with 2nd Roof Rib Hole
18'-30' Temperature Cable Support Assembly for Farm Roofs with
Eave Heights of 40' 5" or Less (Continued)
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions19
Figure 5B
5. Temperature cable support packages for eave height of less than or equal to 40' 5"
Table 5
Temperature Cable Package Part #
BMGR-3336-EF
BMGR-3942-EF
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 21.
33'-42' Temperature Cable Support Assembly for Farm Roofs with
Eave Heights of 40' 5" or Less
20PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
Figure 5C
5. Temperature cable support packages for eave height of less than or equal to 40' 5"
Table 7
DiameterRafter Location
33'
Align 1st Hole in Top of Rafter with 2nd Roof Rib Hole
36'
Align 2nd Hole in Top of Rafter with 3rd Roof Rib Hole
39'
Align 2nd Hole in Top of Rafter with 4th Roof Rib Hole
42'
Align 1
st
Hole in Top of Rafter with 2nd Roof Rib Hole
Table 6
Temperature Cable Package Part #
BMGR-3336-IF
BMGR-3942-IF
33'-42' Temperature Cable Support Assembly for Farm Roofs with
Eave Heights of 40' 5" or Less (Continued)
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions21
Figure 5D
5. Temperature cable support packages for eave height of less than or equal to 40' 5"
33'-42' Temperature Cable Support Assembly for Farm Roofs with
Eave Heights of 40' 5" or Less (Continued)
Figure 5E
22PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Eave Heights of Less than or Equal to 40' 5"
1. All 48' packages shall span three (3) roof panels.
2. The package includes bracing Z-channels for the roof rafters. Hanging angle and cable
support channels.
3. Each set of rafters carry only one temperature cable.
4. Once the farm roof system has been installed, installation of the cable support packages may
proceed as follows.
5. If it is desired to support the cable from the flange of the support channel, it will be necessary to
reinforce the flange with a 12" section of 3" x 3" x 3/16" angle.
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions23
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Temperature Cable Package Part #
BMGR-4880-EF
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 25.
48' Temperature Cable Support Assembly for Farm Roofs with
Eave Heights of 40' 5" or Less
Figure 6A
24PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Temperature Cable Package Part #
BMGR-4800-IF
48' Temperature Cable Support Assembly for Farm Roofs with Eave
Heights of 40' 5" or Less (Continued)
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions25
Figure 6B
6. Temperature cable support system for eave height of less than or equal to 40' 5"
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 27.
24' Temperature Cable Support Assembly for 2 Post Bins with
Farm Roof and No Height Restrictions
Figure 6C
26PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Temperature Cable Package Part #
BMGR-24002EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 28.
24' Temperature Cable Support Assembly for 2 Post Bins with Farm
Roof and No Height Restrictions (Continued)
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions27
Figure 6D
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Temperature Cable Package Part #
BMGR-24002IC
24' Temperature Cable Support Assembly for 2 Post Bins with Farm
Roof and No Height Restrictions (Continued)
Figure 6E
Figure 6F
28PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Temperature Cable Package Part #
BMGR-27002EC
BMGR-30002EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 30.
27'-30' Temperature Cable Support Assembly for 2 Post Bins with
Farm Roof and No Height Restrictions
Figure 6G
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions29
6. Temperature cable support system for eave height of less than or equal to 40' 5"
27'-30' Temperature Cable Support Assembly for 2 Post Bins with
Farm Roof and No Height Restrictions (Continued)
Figure 6H
30PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Temperature Cable Package Part #
BMGR-36002EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 32.
36' Temperature Cable Support Assembly for 2 Post Bins with
Farm Roof and No Height Restrictions
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions31
Figure 6I
6. Temperature cable support system for eave height of less than or equal to 40' 5"
Temperature Cable Package Part #
BMGR-36002IC
36' Temperature Cable Support Assembly for 2 Post Bins with
Farm Roof and No Height Restrictions (Continued)
Figure 6J
Figure 6K
32PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
7. Temperature cable support packages for eave height greater than 40' 5"
Eave Heights Greater than 40' 5"
1. All 27' through 36' packages shall span one roof panel.
2. A rafter support system will be necessary for temperature cable installation in commercial tanks
27' through 36' in diameters that have an eave height of greater than 40' 4".
3. All packages include hanging angle and cable support channel.
4. Each set of rafters should carry only one temperature cable.
5. If it is desired to support the cable from the flange of the support channel, it will be necessary to
reinforce the flange with a 12" section of 3" x 3" x 3/16" angle.
6. No more than one cable should be supported from a pair of roof rafters.
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions33
7. Temperature cable support packages for eave height greater than 40' 5"
Temperature Cable Package Part #
BMGR-2700-EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 35.
27' Temperature Cable Support Assembly for 3 Post Bins with
Farm Roof and No Height Restrictions
Figure 7A
34PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
7. Temperature cable support packages for eave height greater than 40' 5"
See Pages 29 and 30 for rafter installation instructions.
Rafters span one roof panel.
Temperature Cable Package Part #
BMGR-2700-IC
27' Temperature Cable Support Assembly for 3 Post Bins with Farm
Roof and No Height Restrictions (Continued)
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions35
Figure 7B
7. Temperature cable support packages for eave height greater than 40' 5"
Temperature Cable Package Part #
BMGR-3000-EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 37.
30' Temperature Cable Support Assembly for 3 Post Bins with
Farm Roof and No Height Restrictions
Figure 7C
36PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
7. Temperature cable support packages for eave height greater than 40' 5"
See Pages 29 and 30 for rafter installation instructions.
Rafters span one roof panel.
Temperature Cable Package Part #
BMGR-3000-IC
30' Temperature Cable Support Assembly for 3 Post Bins with Farm
Roof and No Height Restrictions (Continued)
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions37
Figure 7D
7. Temperature cable support packages for eave height greater than 40' 5"
Temperature Cable Package Part #
BMGR-3300-EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 39.
33' Temperature Cable Support Assembly for 3 Post Bins with
Farm Roof and No Height Restrictions
38PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
Figure 7E
7. Temperature cable support packages for eave height greater than 40' 5"
Temperature Cable Package Part #
BMGR-3300-IC
33' Temperature Cable Support Assembly for 3 Post Bins with
Farm Roof and No Height Restrictions (Continued)
Figure 7F
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions39
Figure 7G
7. Temperature cable support packages for eave height greater than 40' 5"
Temperature Cable Package Part #
BMGR-3600-EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 41.
36' Temperature Cable Support Assembly for 3 Post Bins with
Farm Roof and No Height Restrictions
Figure 7H
40PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
7. Temperature cable support packages for eave height greater than 40' 5"
See Pages 31 and 32 for 36' roof rafter installation instructions.
Roof rafters span one roof panel.
36' Temperature Cable Support Assembly for 3 Post Bins with
Farm Roof and No Height Restrictions (Continued)
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions41
Figure 7I
7. Temperature cable support packages for eave height greater than 40' 5"
See Pages 31 and 32 for 36' roof rafter installation instructions.
Roof rafters span one roof panel.
36' Temperature Cable Support Assembly for 3 Post Bins with
Farm Roof and No Height Restrictions (Continued)
42PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
Figure 7J
8. Temperature cable support packages for commercial roofs
Commercial Roofs
1. All packages shall span three (3) roof panels.
2. Each set of rafters should carry only one temperature cable.
3. Once the commercial roof system has been installed, installation of the cable support packages may
proceed as follows.
4. Should the angle location be such that the rafter splices coincide with the angle placement, the angle
should be slide one way enough to align the angle holes with the splice bolts or miss the splice bolts.
5. If it is desired to support the cable from the flange of the support channel, it will be necessary to
reinforce the flange with a 12" section of 3" x 3" x 3/16" angle.
6. No more than one cable should be supported from a pair of roof rafters.
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions43
8. Temperature cable support packages for commercial roofs
Temperature Cable Package Part #
BMGR-3942-EC
BMGR-4800-EC
External mount instructions continue on Page 49.
Internal mount instructions continue on Page 45.
39'-48' Temperature Cable Support Assembly for Commercial
Roofs and No Height Restrictions
Figure 8A
44PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
8. Temperature cable support packages for commercial roofs
39'-48' Temperature Cable Support Assembly for Commercial
Roofs and No Height Restrictions (Continued)
Figure 8B
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions45
8. Temperature cable support packages for commercial roofs
Temperature Cable Package Part #
BMGR-3942-IC
BMGR-4800-IC
39'-48' Temperature Cable Support Assembly for Commercial
Roofs and No Height Restrictions (Continued)
Figure 8C
46PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
8. Temperature cable support packages for commercial roofs
54'-60' Temperature Cable Support Assembly for Commercial
Roofs and No Height Restrictions
Figure 8D
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions47
8. Temperature cable support packages for commercial roofs
54'-60' Temperature Cable Support Assembly for Commercial
Roofs and No Height Restrictions (Continued)
Figure 8E
48PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
8. Temperature cable support packages for commercial roofs
Typical 2 Rib External Mounting of Temperature Cable Bracket
Figure 8F
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions49
NOTES
50PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions
9. Warranty
9101239_1_CR_rev7.DOC (revised July 2009)
GSI Group, LLC Limited Warranty
The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship
under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale,
14 months from arrival at port of discharge, whichever is earlier. The end-user’s sole remedy (and GSI’s only obligation)
is to repair or replace, at GSI’s option and expense, products that in GSI’s judgment, contain a material defect in materials
or workmanship. Expenses incurred by or on behalf of the end-user without prior written authorization from the GSI
Warranty Group shall be the sole responsibility of the end-user.
Warranty Extensions:
The Limited Warranty period is extended for the following products:
ProductWarranty Period
Performer Series Direct Drive Fan Motor3 Years
AP Fans and Flooring
Cumberland
Feeding/Watering
Systems
Grain SystemsGrain Bin Structural Design5 Years
Grain Systems
Farm Fans
Zimmerman
All Fiberglass HousingsLifetime
All Fiberglass PropellersLifetime
Feeder System Pan Assemblies5 Years **
Feed Tubes (1-3/4" and 2.00")10 Years *
Centerless Augers10 Years *
Watering Nipples10 Years *
Portable and Tower Dryers2 Years
Portable and Tower Dryer Frames and
Internal Infrastructure †
5 Years
* Warranty prorated from list price:
0 to 3 years - no cost to end-user
3 to 5 years - end-user pays 25%
5 to 7 years - end-user pays 50%
7 to 10 years - end-user pays 75%
** Warranty prorated from list price:
0 to 3 years - no cost to end-user
3 to 5 years - end-user pays 50%
† Motors, burner components
and moving parts not included.
Portable dryer screens included.
Tower dryer screens not included.
GSI further warrants that the portable and tower dryer frame and basket, excluding all auger and auger drive components,
shall be free from defects in materials for a period of time beginning on the twelfth (12
and continuing until the sixtieth (60
th
) month from the date of purchase (extended warranty period). During the extended
th
) month from the date of purchase
warranty period, GSI will replace the frame or basket components that prove to be defective under normal conditions of
use without charge, excluding the labor, transportation, and/or shipping costs incurred in the performance of this
extended warranty.
Conditions and Limitations:
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH
ABOVE. SPECIFICALLY, GSI MAKES NO FURTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OR USE IN CONNECTION WITH: (I) PRODUCT MANUFACTURED OR SOLD BY GSI OR (II) ANY ADVICE,
INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT, REPRESENTA TIVE OR
EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY
FOR A PARTICULAR PURPOSE, OR DESIGN OF SUCH PRODUCTS.
GSI shall not be liable for any direct, indirect, incidental or consequential damages, including, without limitation, loss of
anticipated profits or benefits. The sole and exclusive remedy is set forth in the Limited Warranty, which shall not exceed
the amount paid for the product purchased. This warranty is not transferable and applies only to the original end-user. GSI
shall have no obligation or responsibility for any representations or warranties made by or on behalf of any dealer, agent
or distributor.
GSI assumes no responsibility for claims resulting from construction defects or unauthorized modifications to products
which it manufactured. Modifications to products not specifically delineated in the manual accompanying the equipment at
initial sale will void the Limited Warranty.
This Limited Warranty shall not extend to products or parts which have been damaged by negligent use, misuse, alteration,
accident or which have been improperly/inadequately maintained. This Limited Warranty extends solely to products
manufactured by GSI.
Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the
location and installation of products manufactured or sold by GSI.
PNEG-1810 Bin Manager Temperature Cable Support Bracket Instruc tions51
This equipment shall be installed in accordance with
the current installation codes and applicable
regulations, which should be carefully followed in all