Grundfos SB Series, SBA Series, SB HF Series, SB 3-25, SB 3-35 Installation And Operating Instructions Manual

...
SB, SBA
Installation and operating instructions
GRUNDFOS INSTRUCTIONS
English (GB) Installation and operating instructions

English (GB)

Original installation and operating instructions
These installation and operating instructions describe Grundfos SB, SBA and SB HF.
Sections 1-5 give the information necessary to be able to unpack, install and start up the product in a safe way.
Sections 6-10 give important information about the product, as well as information on service, fault finding and disposal of the product.
CONTENTS
Page
1. General information

1.1 Hazard statements

1.2 Notes
2. Receiving the product
2.1 Inspecting the packaging
2.2 Scope of delivery
3. Installing the product
3.1 Location
3.2 Mechanical installation
3.3 Pump position
3.4 Connecting the outlet hose or pipe
3.5 Non-return valve for SB pumps
3.6 Electrical connection
4. Starting up the product
4.1 SBA starting and stopping conditions
5. Handling and storing the product
5.1 Handling the product
5.2 Storing the product
5.3 Frost protection
6. Product introduction
6.1 Product description
6.2 SB pumps
6.3 SB HF pumps
6.4 SBA pumps
6.5 SBA dry-running protection
6.6 Intended use
6.7 Pumped liquids
6.8 Identification
7. Maintaining the product
8. Fault finding the product
9. Technical data
9.1 Operating conditions
9.2 Mechanical data
9.3 Electrical data
9.4 Dimensions
10. Disposing of the product
2
2 3
3
3 3
3
3 5 6 6 6

1. General information

7
1.1 Hazard statements
8
8
The symbols and hazard statements below may appear in Grundfos installation and operating
8
instructions, safety instructions and service
8
instructions.
8 8
9
9 9 9 9 9 9 9
10
10
11
13
13 13 14 14
15
Read this document before you install the product. Installation and operation must comply with local regulations and accepted codes of good practice.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Make sure that the system in which the pump is incorporated is designed for the maximum pump pressure.
This pump has been evaluated for use with water only.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious personal injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious personal injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate personal injury.
2
The hazard statements are structured in the following way:
SIGNAL WORD
Description of hazard
Consequence of ignoring the warning.
- Action to avoid the hazard.

1.2 Notes

The symbols and notes below may appear in Grundfos installation and operating instructions, safety instructions and service instructions.
Observe these instructions for explosion­proof products.
A blue or grey circle with a white graphical symbol indicates that an action must be taken.
A red or grey circle with a diagonal bar, possibly with a black graphical symbol, indicates that an action must not be taken or must be stopped.
If these instructions are not observed, it may result in malfunction or damage to the equipment.
Tips and advice that make the work easier.

2. Receiving the product

2.1 Inspecting the packaging

On receipt of the product, do the following:
1. Check that the product is as ordered. If the product is not as ordered, contact the supplier.
2. Check that no visible parts have been damaged. If any visible parts have been damaged, contact the transport company.

2.2 Scope of delivery

The box contains the following items:
• 1 pump
• 1 adapter
• 1 installation and operating instructions
• 1 quick guide
• 1 floating inlet strainer, for side inlet variant only
• 1 non-return valve, for SB only.

3. Installing the product

Observe local regulations concerning limits for manual lifting or handling.
CAUTION
Crushing of feet
Minor or moderate personal injury
- Use safety shoes when handling the pump.
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before you start any work on the product. Make sure that the power supply cannot be accidentally switched on.

3.1 Location

Install the pump in a frost-free location. Before the pump is submerged in the well or tank,
make sure that the well or tank does not contain sand or solid sediment.
Install the pipe so that the pump is not exposed to mechanical stress.
English (GB)
3
3.1.1 Maximum installation depth
Max.
13 m/43 ft
Max.
20 m/66ft
SBA 3-35 SBA 3-45
Min.
5 cm/2 inch
Min. 10 cm/ 4 inch
English (GB)
Product
Maximum installation depth [m]
SB 10
SBA 10
SB HF 15
3.1.2 Highest tapping point for SBA pumps
Install SBA pumps so that the height between the pump and the highest tapping point does not exceed these values:
SBA 3-35: 13 m. SBA 3-45: 20 m.
SB and SBA pump with a float switch and side inlet
Fig. 2 Minimum space for SB and SBA pump in
a well or tank
SB HF pump with a float switch
TM06 7644 4016TM07 1399 1518
Fig. 1 Highest tapping point for SBA
3.1.3 Minimum space
Pumps installed with a float switch require a free space between the float switch and the wall to ensure free movability.
Pumps with side inlet require a free space between the floating inlet strainer and the wall.
If you install the pump in a well or tank, the minimum free space must be as shown in figs 2 and 3.
Pumps installed without a float switch require a space that corresponds to the physical dimensions of the pump.
4
TM06 7648 4116
Fig. 3 Minimum space for SB HF pump. This
example shows installation in a well
3.1.4 Vertical placement of SB HF pump
Tank installation of SB HF
Place the pump on the bottom of the tank. The pump must not run dry.
Well installation of SB HF
Install the pump so that the pump inlet is at least 1 m above the bottom of the well to avoid suction of sand and impurities. See fig. 3.
Use rigid metal pipes to hang the pump, and secure the pipes with brackets at the top of the well.
Do not use the power cable to hang the pump above the bottom of the well.
Secure the pump by attaching a wire to the lifting eye on the top of the pump. Do not hang the pump on the lifting wire.
3.1.5 Adjustment of the float switch
To make sure that the float switch can start and stop the pump, adjust the start and stop level by changing the free cable length between the float switch and the lifting handle.
A reduced free cable length results in more starts and stops and a small difference in level. The minimum free cable length is 10-18 cm. See fig. 4.
• An increased free cable length results in fewer starts and stops and a large difference in level.
Make sure that the float switch can move freely. Make sure that the stop level does not fall below the
pump inlet strainer.

3.2 Mechanical installation

3.2.1 Lifting the product
Lift the pump by the lifting handle. Never lift the pump by the power cable. Tie a rope to the lifting handle or lifting eye instead.
Do not lift the product by the power cable. Lift the product by means of a rope.
English (GB)
Fig. 4 Minimum free cable length for float
switch
Fig. 5 Lifting the pump
TM07 1355 1618
TM07 1402 1518
5

3.3 Pump position

15 °
90 °
0 °
3
/4"
1"
English (GB)
3.3.1 Pump position of SB and SBA
Use the pump in the vertical position as shown in fig.
5.
Fig. 6 Position of SB, SBA pumps
3.3.2 Pump position of SB HF
The pump is suitable for both vertical and horizontal installation. However, the pump shaft must never fall below the horizontal plane. See fig. 7.

3.4 Connecting the outlet hose or pipe

Product
SB G 3/4 or 1
SBA G 3/4 or 1
SB HF G 1 1/4
The outlet hose or pipe can be connected to the pump outlet port by means of an adapter. You can also connect a pipe directly to the pump outlet.
SB and SBA pumps include an adapter. Cut off the adapter so that it matches the outlet port diameter.
TM06 7643 4016TM07 1400 1518
Fig. 8 SB and SBA adapter
External pipe thread [inch]

3.5 Non-return valve for SB pumps

Connect the non-return valve to the SB pump outlet. The non-return valve has G 1" threads for connection to the adapter or the pipe.
TM06 7645 2715TM06 7646 4016
Fig. 7 Position of SB HF pumps
6
Fig. 9 Non-return valve

3.6 Electrical connection

DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before you start any work on the product. Make sure that the power supply cannot be accidentally switched on.
- The pump must be earthed.
DANGER
Electric shock
Death or serious personal injury
- The protective earth of the socket outlet must be connected to the protective earth of the pump. The plug must therefore have the same PE connection system as that of the socket outlet. If not, use a suitable adapter.
We recommend that you fit the permanent installation with a residual-current circuit breaker, RCCB, with a tripping current less than 30 mA.
DANGER
Electric shock
Death or serious personal injury
- If the pump is used for cleaning or other maintenance of swimming pools, garden ponds or similar places, make sure that the pump is supplied through a residual-current circuit breaker, RCCB, with a tripping current of 30 mA.
3.6.1 Thermal protection
The pump has a built-in thermal switch and requires no additional motor protection. If the pump is running without water, or if it is otherwise overloaded, the built-in thermal switch will cut out. When the motor has cooled to normal temperature, it will restart automatically.
3.6.2 Connecting to external controller
SB
SB pumps must be connected to an external controller. We recommend a Grundfos Pressure Manager: net.grundfos.com/qr/i/97506325
SBA
SBA pumps have an integrated control unit.
SB HF
SB HF pumps must be connected to an external controller. We recommend a Grundfos Pressure Manager: net.grundfos.com/qr/i/97506325
3.6.3 Power supply failure
In case of a power supply failure, the pump restarts automatically when power returns and runs for at least 10 s.
English (GB)
DANGER
Electric shock
Death or serious personal injury
- Connect pumps that are delivered without cable and/or plugs to an external main switch with a minimum contact gap of 3 mm in all poles.
Make sure that there is at least 3 m free cable above the liquid level.
Check that the supply voltage and frequency correspond to the values stated on the pump nameplate.
The electrical connection must be carried out by an authorised electrician in accordance with local regulations.
7