Groen (2)HY-5EF General Manual

HyPerSteam Pressureless Steamer
Description
Steamer shall be a Groen Model (2)HY-5E stainless steel double stacked pressureless steamer, each with a self­contained atmospheric 15.5 KW electric steam generator, per bulletin 140808 as follows:
Construction
Each steamer cavity and cabinet shall be all stainless steel construction with removable right and left side pan­els providing access to internal components.
Steamer doors are all stainless steel with strong continu­ous hinge and are field reversible for left or right swing, doors shall be provided with a one piece, replaceable seal. Easy open handle and latch shall provide positive lock and seal when door is pushed or slammed shut.
Hidden magnetic door switch cuts power to blower and shuts down power to generator when that door is opened. Pan support racks shall be polished stainless steel and removable for easy cleaning. A stainless steel condensate collection tray is positioned under each cavity door.
Finish
Cabinet exterior including doors shall be finished to a #3 uniform finish. Cavity interiors are polished stainless steel. Control panel face plates shall be smudge resistant polyester film, ensuring maximum ease in cleaning and maintaining an attractive appearance.
UL Listing
Steamer shall be UL listed.
Sanitation
Unit shall be designed and manufactured to meet NSF codes and be NSF listed. Unit shall allow operator to delime steam generator through deliming port on top, without tools or service call. Push button auto-clean feature is standard.
Controls
Steamer controls shall include an ON-OFF power but­ton; 60 minute mechanical timer, with continuous steam setting; and READY light which indicates when cavity is warm and ready for steaming. Auto-clean button initiates deliming cycle for each unit.
Performance Features
Each steamer shall have a powerful side mounted blower, which increases steam velocity and provides efficient steam distribution throughout cavity and between loaded pans. Steam generator delivers 3.1 KW power input per 2 1/2” deep steam pan.
Heat up time to READY shall be 10 minutes or less, under normal conditions. Cavity is kept warm and ready for instant steam between loads. No cavity warm up required, after READY light comes on.
delime indicator light warns operator of need to delime steam generator. Unit will shut off if water level is low. When power is turned “off”, unit automatically blows down the steam generator to reduce sediment build-up.
Model (2)HY-5E Shown
Atmospheric Steam Generator
Each unit shall have an electric heated rear mounted steam generator to provide atmospheric steam to the chamber at a temperature of approximately 212°F. Steam generator has an electric water sensor. Electric heating elements are replaceable from the side.
Pan Capacity
Pan Size Per Cavity Total
12 x 20 x 1” 10 20
12 x 20 x 2 1/2” 5 10
12 x 20 x 4” 3 6
Installation
Unit requires two 208, 240 or 480 volt, single or three phase electric service connections. Unit requires dual 3/4” NH cold water supply lines and 2” free venting drain.
Water Supply Requirements
All steam systems are subject to contamination and failure due to mineral content found in all water supplies. To minimize service problems, a Groen PureSteem Water Treatment System is recommended.
Options/Accessories
Groen PureSteem Water Treatment System Single cold water connection adaptor
Origin of Manufacture
Steamers shall be designed and manufactured in the United States.
models (2)HY-5E/EF
10 Pan Total Capacity Stainless Steel Stacked Pressureless Steamers
Table Top or Stand Mounted Self-Contained Electric Heated
Short Form
Unit shall be a Groen double stacked HyPerSteam pressureless steamer Model (2)HY-5E each with self­contained, atmospheric electric heated steam generator, per bulletin 140808. All stainless steel construction with powerful blower to circulate steam within each cavity. Standard operating controls including: 60 minute mechanical timer, constant steam setting, ready light and CLEAN cycle button to initiate deliming. Simple generator deliming through deliming port on top. Doors are field reversible, with easy open latch and hidden magnetic door switch. The atmospheric steam generators require no pressure gauge or switches, have automatic drain and 15.5 KW power input. Unit shall come up to steam in 7-10 minutes from a cold start, and provide warm cavity-instant steam capability. See other side for electric, water and drain connections required. Made in the U.S.A.
Applications
Pasta Rice Vegetables (Fresh & Frozen) Seafood (Fresh & Frozen) Poultry Potatoes Eggs Meats Reheat Cook-Chill & Prepared Foods
1055 Mendell Davis Drive, Jackson, MS 39272 888-994-7636, unifiedbrands.net
Please reference our website for the most updated product information and specifications.
Groen HyPerSteam, Page 4
140808C
Revised 08/09
74.5
64.61
38.2
1
44.0
3
3
AMPS
240
KW
MAX.
PHASE
VOLTAGE
208
480
3 19.1
1 32.3
15.5
15.5
15.5
15.5
15.5
15.5
ELECTRICAL REQUIREMENTS
(EACH UNIT)
8
1 1/4
TABLE TOP OR COUNTER (CUSTOMER PROVIDED)
[203]
[32]
3
21 11/16
3
15 19/32
[76]
[551]
[76]
[397]
REAR OF TABLE
OR COUNTER
TABLE TOP OR COUNTER
OPTIONAL 4 LEGS
MOUNTING HOLES IN BASE USE 3/8" 16 BOLTS WHICH
MUST NOT EXTEND INTO STEAMER BY MORE THAN 3/8" [10]
30 13/16
[783]
SERVICE CONNECTIONS & NOTES:
1 DRAIN CONNECTION: 2" [50.8] TUBE (DRAIN FREE VENTING).
2
3
TWO ELECTRICAL CONNECTIONS: 1" [25.4] CONDUIT FITTING
4
MINIMUM REAR AND SIDE CLEARANCE: REAR = 6 "[152.4] LEFT SIDE = 2" [50.8] RIGHT SIDE = 2 [50.8]
21 5/8
[549]
46 1/2 [1181]
2 3
1
11/16
[17]
15
[381]
3
[520]
20 1/2
2
SIDE VIEW
OPTIONAL SUPPORT STAND
21 9/16
[548]
6
[152]
1 1/2
[38] MINIMUM
2 5/8
[67] MAXIMUM
UNTREATED WATER SUPPLY CONNECTION
DETAIL VIEW
OF WATER CONNECTIONS
REAR OF STEAMER
DIMENSIONS IN BRACKETS [ ] ARE MM.
5
1
1
1 1/4
[32]
1
1 5/8
[41]
UNIT FUSE
BOX
17 3/8
[441]
[765]
30 1/8
4
[152]
6
[51]
2
4
[772]
33 3/8
FRONT VIEW
UNIT FUSE
BOX
FINISHED FLOOR
64 3/8
[1635] MIN
[470]
18 1/2
[51]
2
4
3
[597]
23 1/2
[511]
20 1/8
1
[851]
33 1/2
[597]
23 1/2
39
[991]
3
3
2
COLD WATER SUPPLY AT 30 TO 60 PSIG WITH A FLOW RATE OF 0.75 - 1.50 GPM PER CAVITY (1.50 - 3.00 GPM TOTAL) AND WITH A 3/4" NH CONNECTION.
TREATED WATER SUPPLY CONNECTION
Models (2)HY-5E/EF
P/N 126000 REV B
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2009 Unified Brands. All Rights Reserved. DOVER® and the DOVER® Logo are registered trademarks in the United States [and various other countries] of Unified Brands, a wholly-owned subsidiary of Dover Corporation.