Grizzly G9849 User guide

Page 1
G9849
10
20
30
40
50
60
70
80
90
0
0
.5
.4
.9
.3
.8
.2
.7
.1
.6
.001'' 0—1''
20
10
90
80
70
60
50
40
30
0
ON
OFF
Magnetic Base/Dial
Indicator Combo
The Model G9849 Magnetic Base/Dial Indicator Combo features a 0.001" resolution, 1" range, and a 2" easy-to-read dial. The indicator is supplied with a decade counter, adjustable markers and a dial face lock. The magnetic base features an ON/OFF switch, a magnetic base for both tubular and flat mounting, a stout column, fine-tune adjustment knob and 2 positioning joints. This tool will allow you to accurately and quickly measure runout, lead, and motion. Please familiarize yourself with the terminology of the components to maximize the effective use of this tool.
2
1
3
6
4
5
Figure 1. Indicator components.
Listed below are the dial indicator components. Match the description with the corresponding part number in the illustration above.
1. The adjustable markers can be moved along the circumference of the dial.
2. The dial lock secures the dial face after being rotated around the indicator body.
3. On the scale, the distance between the lines equals 0.001" (one thousandths of an inch).
4. These numbers represent 0.010" (ten thou- sandths of an inch).
5. The contact point touches the surface to be measured.
6. Each number on the decade counter repre- sents one full rotation of the needle and is equal to 0.100" (one hundred thousandths of an inch).
-1-
1
2
8
3
7
6
5
4
Figure 2. Magnetic base components.
Below is a list of the magnetic base compo­nents.
1. The column supports the mounting assem- bly.
2. The lock knobs secure the mounting assem- bly after adjustments are made.
3. The indicator mounting stud fastens indicator to the boom.
4. The ON/OFF switch for the magnet.
5. The magnetic base. One mounting surface
on the back and one on the bottom.
6. The fine-tune adjustment knob allows the indicator to be adjusted in small increments.
7. One of 2 pivot joints that allows articulation of the mounting assembly.
8. The boom supports the mounting assembly.
© 2002 Grizzly Industrial, Inc.
Page 2
Dial IndicatorMagnetic Base
The magnetic base supports the column and the mounting assembly. To assemble the column to the base:
1. Locate the flat washer in the package con­taining the column/mounting assembly and attach the washer to the threaded end of the column.
2. Thread the column into the threaded hole on the top of the magnetic base until it stops turning.
3. Finish tightening the column by turning the jam nut with an
11
⁄16" wrench.
The indicator must be secured to the base prior to use. Please refer to Figure 4 while reading these instructions.
1. Loosen the lock knob that secures the mounting stud to the boom and remove the stud.
2. Unscrew and remove the knurled nut and flat washer from the mounting stud, and insert the threaded end of the stud into the flange on the back of the dial indicator.
The stud can be inserted from the left- or the right-hand side, depending on your mounting needs.
3. Attach the washer and thread the knurled nut back onto the threads on the stud. Insert the plain end of the stud into the pivot joint. Be mindful that this pivot joint has 2 holes and only one is sized correctly for the stud. Also, it may be necessary to rotate the sleeve on the pivot joint to correctly align the parts so the stud can be inserted.
Figure 3. Mounting the column.
4. Tighten the lock knob for the pivot joint.
5. Tighten the knurled nut with a flat blade
screwdriver to lock the dial into place.
Figure 4. Mounting the indicator onto the
mounting stud.
-2-
© 2002 Grizzly Industrial, Inc.462402622
Page 3
Basic Operations
10
20
30
40
50
60
70
80
90
0
0
.5
.4 .9
.3 .8
.2
.7
.1
.6
.001' ' 0—1''
20
10
90
80
70
60
50
40
30
0
90˚
Adjusting the Assembly
The dial indicator can be used in many ways and the magnetic base can be positioned on flat or round surfaces. The list below detail guidelines for use:
1. Use the ON/OFF switch on the magnetic base whenever moving the unit to help avoid
marring the surface that it is resting on and to prevent sudden jarring which could damage the internal components of the indicator.
2. Make adjustments to the support assembly only with the base magnetically secured to a steel or iron object. This will help guard against damage to the indicator should the base fall.
3. Loosen the lock knobs to adjust the height and angle of the support boom. Trying to defeat the locks to move the indicator a small amount will cause premature wear on the system.
The magnetic base and indicator can be posi­tioned in many ways. The bottom of the magnetic base is notched to allow for mounting to curved surfaces as well as having a ground, flat surface. The back of the base is ground flat for mounting as well. Care must be taken to secure the base to a suitable surface. Hanging the base upside­down or from the side of a machine may cause the unit to fall. Also, sheet metal may not have the mass need to properly support the unit. Dropping the dial indicator will reduce its accuracy and may make it unusable.
4. Gently, try to rock the base after turning the switch to the ON position to ensure that the setup is secure.
Figure 5. The support assembly can be posi­tioned in any fashion by loosening the 2 pivot
joints.
Figure 6. The indicator can be oriented in any
direction by loosening the mounting stud, loos-
ening the boom and raising the boom along the
column.
fine-tune adjustment knob
-3-
462402622
Figure 7. Fine tuning the dial to read zero or
any other reference point is made easy with the
fine-tune adjustment knob.
© 2002 Grizzly Industrial, Inc.
Page 4
Setting the Contact Point
10
20
30
40
50
60
70
80
90
0
0
.5
.4
.9
.3
.8
.2
.7
.1
.6
.001'' 0—1''
20
10
90
80
70
60
50
40
30
0
10
20
30
40
50
60
70
80
90
0
0
.5
.4
.9
.3
.8
.2
.7
.1 .6
.001'' 0—1''
20
10
90
80
70
60
50
40
30
0
C
L
90˚
One of the most important setup issues with a dial indicator is to make sure the contact point is perpendicular to its expected motion or to the motion of the object to be tested. Failure to ensure proper setup will result in an error in mea­surement. Please refer to Figure 7 and 8.
Reading the Dial
0.400"
0.017"
Figure 9. The dial reads 0.417".
The dial indicator is calibrated to read 0.001" and has a range of 1". When the contact point is not touching anything, the pointers for each dial will read “under” the zero inch mark.
Figure 8. The indicator is positioned perpendic-
ular to the axis of a round bar. When the bar is turned, the runout or lateral motion is indicated
by motion of the needle.
Another important note about setup is that the contact point must be resting against the part before any change can be indicated. It is there­fore necessary to adjust the unit so the needle has moved to ensure a proper measurement. Use the fine-tune adjustment knob illustrated in
Figure 7.
Dial Lock
Loosening the dial lock allows the dial face to be rotated. This can be helpful when an absolute measurement is desired and changing the adjust­ments to the column, boom and fine adjustment knob are difficult or impractical. In Figure 9 the dial face has been rotated.
-4-
It is important to understand that the pointers rotate in opposite directions as the contact point is depressed. The pointer for the large dial rotates clockwise and the pointer for the smaller dial rotates counterclockwise when the contact point is depressed. You must keep track of the number of revolutions for the smaller dial! The first revolu­tion is indicated by the numbers on the outer ring of the numbers and the second revolution is indi­cated by the innermost numbers. The example in Figure 9 indicates 0.417".
As with the decade counter, the main dial has a second set of numbers. These can be used to keep track of the actual motion of the contact point when it is released.
The dial indicator can also be set up to be used as a range tester. There are 2 adjustable mark- ers that can be positioned on the dial face. A range can then be checked. In the example in Figure 9, the adjustable markers have been set to measure between 0.030" and 0.065". Again, if a larger range than 0.100" is needed, the revolu­tions of the pointer on the smaller dial will have to be counted.
462402622
Adjustable Markers
© 2002 Grizzly Industrial, Inc.
Loading...