Grizzly G0573 User Manual

TWO SPEED
FLOOR AIR FILTER
MODEL G0573
INSTRUCTION MANUAL
COPYRIGHT © DECEMBER, 2004 BY GRIZZLY INDUSTRIAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#BL6811 PRINTED IN CHINA
Some dust created by power sanding, sawing, grind­ing, drilling, and other construction activities contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
• Lead from lead-based paints.
• Crystalline silica from bricks, cement, and other masonry products.
• Arsenic and chromium from chemically treated lumber.
Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to fil ter out microscopic particles.
-
Table of Contents
INTRODUCTION ............................................................................................................................... 2
Foreword .... 2
Contact Info 
SECTION 1: SAFETY .......................................................................................................................
Safety Instructions for
SECTION 2: CIRCUIT REQUIREMENTS ........................................................................................
110V Operation ..........................................................................................................................
SECTION 3: SET UP ........................................................................................................................
Set Up Safety .............................................................................................................................
Items Needed For Set Up .......................................................................................................... 7
Unpacking .. 7
SECTION 4: OPERATIONS ...........................................................................................................
Operation Safety ......................................................................................................................
Operations  10
Available Accessories .............................................................................................................. 10
SECTION 5: MAINTENANCE ........................................................................................................
G0573 Wire Diagram ...............................................................................................................
G0573 Parts Breakdown .......................................................................................................... 13
WARRANTY AND RETURNS ........................................................................................................
Machinery ............................................................................................... 3
10
10
11
12
16
2
3
6
6
7
7
INTRODUCTION
Foreword
We are proud to offer the Model G0573 Two Speed Floor Air Filter. This machine is part of a growing Grizzly family of fine woodworking machinery. When used according to the guidelines set forth in this manual, you can expect years of trouble-free, enjoyable operation and proof of Grizzly’s com mitment to customer satisfaction.
We are pleased to provide this manual with the Model G0573. It was written to guide you through assembly, review safety considerations, and cover general operating procedures.
The specifications, drawings, and photographs illustrated in this manual represent the Model G0573 as supplied when the manual was pre­pared. For your convenience, we always keep current Grizzly manuals available on our website at www.grizzly.com. Any updates to your machine will be reflected in these manuals as soon as they are complete.
Contact Info
If you have any comments regarding this manual, please write to us at the address below:
Grizzly Industrial, Inc.
C
/O Technical Documentation
­Bellingham, WA 98227-2069
We stand behind our machines. If you have any service questions or parts requests, please call or write us at the location listed below.
E-Mail: techsupport@grizzly.com Web Site: http://www.grizzly.com
P.O. Box 2069
Grizzly Industrial, Inc.
1203 Lycoming Mall Circle
Muncy, PA 17756
Phone: (570) 546-9663
Fax: (800) 438-5901
-2-
MACHINE DATA
SHEET
Customer Service #: (570) 546-9663 • To Order Call: (800) 523-4777 • Fax #: (800) 438-5901
MODEL G0573 TWO SPEED FLOOR AIR FILTER
Motor ..............1 3⁄4 HP, 2-Speed, 110 Volt, 1 PH
Amp Draw .............HI = 14 Amps, LO = 12 Amps
Dimensions ............30 1/2"L x 25 3/4" W x 29 3/8"H
Pre-Filter Dimensions ........... 25"L x 25"H x
Primary Filter Dimensions
Weight .....................................................165 lbs.
Airflow .................................... 1500 to 2000 CFM
Pre-Filter Filtration .............................. 3 Microns
Primary Filter Filtration .. .3 Microns (2000 CFM)
24"L x 24"H x 113/4"D
7
/8"D
G0573 Two Speed Floor Air Filter
SECTION 1: SAFETY
For Your Own Safety, Read Instruction Manual Before Operating this Machine
The purpose of safety symbols is to attract your attention to possible hazardous conditions. This
manual uses a series of symbols and signal words which are intended to convey the level of importance of the safety messages. The progression of symbols is described below. Remember that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measures.
Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. It may also be used to alert against unsafe practices.
NOTICE
This symbol is used to alert the user to useful information about proper operation of the machine.
Safety Instructions for Machinery
1. READ THROUGH THE ENTIRE MANUAL BEFORE STARTING MACHINERY.
Machinery presents serious injury hazards to untrained users.
2. ALWAYS USE ANSI APPROVED SAFETY GLASSES WHEN OPERATING MACHINERY. Everyday eyeglasses only
have impact resistant lenses, they are NOT safety glasses.
4. ALWAYS USE HEARING PROTECTION WHEN
Machinery noise can cause permanent hearing damage.
5. WEAR PROPER APPAREL. DO NOT wear loose clothing, gloves, neckties, rings, or jewelry which may get caught in moving parts. Wear protective hair covering to con tain long hair and wear non-slip footwear.
OPERATING MACHINERY.
-
3. ALWAYS WEAR AN ANSI APPROVED RESPIRATOR WHEN OPERATING MACHINERY THAT PRODUCES DUST.
Wood dust is cancer and severe respiratory illnesses.
G0573 Two Speed Floor Air Filter
a carcinogen and can cause
6. NEVER OPERATE MACHINERY WHEN TIRED, OR UNDER THE INFLUENCE OF DRUGS OR ALCOHOL. Be mentally alert
at all times when running machinery.
-3-
Safety Instructions for Machinery
7. ONLY ALLOW TRAINED AND PROP­ERLY SUPERVISED PERSONNEL TO OPERATE MACHINERY. Make sure
operation instructions are safe and clearly understood.
8. KEEP CHILDREN AND VISITORS AWAY.
Keep all children and visitors a safe dis­tance from the work area.
9. MAKE WORKSHOP CHILD PROOF. Use padlocks, master switches, and remove start switch keys.
10. NEVER LEAVE WHEN MACHINE IS RUNNING. Turn power OFF and allow all
moving parts to come to a complete stop before leaving machine unattended.
11. DO NOT USE IN DANGEROUS
ENVIRONMENTS. DO NOT use machin-
ery in damp, wet locations, or where any flammable or noxious fumes may exist.
12. KEEP WORK AREA CLEAN AND WELL
LIT. Clutter and dark shadows may cause
accidents.
13. USE A GROUNDED EXTENSION CORD RATED FOR MACHINE AMPERAGE.
Undersized cords overheat and lose power. Replace extension cords if they become damaged. DO NOT use extension cords for 220V machinery.
16. MAKE SURE GUARDS ARE IN PLACE AND WORK CORRECTLY BEFORE USING MACHINERY.
17. REMOVE ADJUSTING KEYS AND WRENCHES. Make a habit of checking for
keys and adjusting wrenches before turn ing machinery
18. CHECK FOR DAMAGED PARTS
BEFORE USING MACHINERY. Check
for binding and alignment of parts, broken parts, part mounting, loose bolts, and any other conditions that may affect machine operation. Repair or replace damaged parts.
19. USE RECOMMENDED ACCESSORIES.
Refer to the instruction manual for recom mended accessories. The use of improper accessories may cause risk of injury.
20. DO NOT FORCE MACHINERY. Work at the speed for which the machine or acces sory was designed.
21. SECURE WORKPIECE. Use clamps or a vise to hold the workpiece when practi­cal. A secured workpiece protects your hands and frees both hands to operate the machine.
22. DO NOT OVERREACH. Keep proper foot ing and balance at all times.
ON.
-
-
-
-
14.
ALWAYS DISCONNECT FROM POWER SOURCE BEFORE SERVICING MACHINERY. Make sure switch is in
position before reconnecting.
15. MAINTAIN MACHINERY WITH CARE. Keep blades sharp and clean for best and safest performance. Follow instructions for lubricating and changing accessories.
-4-
OFF
23. MANY MACHINES WILL EJECT WORKPIECE TOWARD OPERATOR.
Know and avoid conditions that cause the workpiece to "kickback."
24. ALWAYS LOCK MOBILE BASES BEFORE OPERATING MACHINERY
G0573 Two Speed Floor Air Filter
.
Additional Safety for Air Filters
1. FILTER USE. This filter unit is only designed
to remove very fine wood particles from the air. DO NOT use this machine to filter or collect liquids (especially flammables), metal shavings, lead paint, or asbestos. DO NOT use this machine to dissipate smoke, fumes, or when spraying paint.
2. FILTER REMOVAL. Unplug machine before removing filter. Removing primary fil­ter exposes the impeller, which may cause serious injury during contact if the machine is connected to the power source.
3. PROBLEMS WITH MOVING PARTS. Problems concerned with moving parts or
accessories must be investigated and cor­rected with the power disconnected and after the fan blade come to a complete stop.
4. EXPLOSION RISK. Suspended dust par-
ticles in conjunction with an ignition source may cause an explosion. Do not operate this machine in areas where explosion risks would be high if dust were dispersed into the area. Areas of high risk include, but are not limited to, areas near pilot lights or open flames.
5. BURNING OR SMOKING MATERIAL
Avoid collecting any material that is burning or smoking, including matches, cig
and hot ashes.
arettes,
6. MACHINE OPERATION. Always operate the machine with the filter in place
the primary filter is removed, the impeller is exposed to the unfiltered opening.
7. FILTER CLEANING AND REPLACEMENT. Wear a respirator and safety glasses when changing or replacing filters. Empty dust into an approved container and dispose of properly.
8. OPERATING DIFFICULTIES. If at any time
you are experiencing difficulties perform­ing the intended operation machine! Then contact our service depart­ment or ask a qualified expert how the operation should be performed.
9. ALLERGIC REACTIONS. Be aware that certain woods may cause an allergic reac
tion in people and animals, especially when exposed to fine dust. Make sure you know what type of wood dust you will be exposed to in case there is a possibility of an allergic reaction. Always wear an ANSI approved respirator!
10.LEAD-PAINT DUST OR ASBESTOS FIBERS. This machine will not protect
.
against lead-paint dust or asbestos fibers. These materials must be collected with spe cial equipment due to high hazard to human health. DO NOT attempt to collect these materials with this machine.
, stop using the
. When
-
-
Like all machines there is danger associ­ated with the Model G0573. Accidents are frequently caused by lack of familiarity or failure to pay attention. Use this machine with respect and caution to lessen the pos sibility of operator injury. If normal safety precautions are overlooked or ignored, seri ous personal injury may occur.
G0573 Two Speed Floor Air Filter
No list of safety guidelines can be complete. Every shop environment is different. Always consider safety first, as it applies to your individual working conditions. Use this and
-
-
other machinery with caution and respect. Failure to do so could result in serious per­sonal injury, damage to equipment, or poor work results.
-5-
SECTION 2: CIRCUIT REQUIREMENTS
110V Operation
Electrocution or fire could result if this machine is not grounded correctly or
Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro cess. DO NOT connect the machine to the power source until instructed to do so.
-
Amperage Draw
The 1 3⁄4 HP motor on the Model G0573 will draw the following amps:
Motor Load ....................................... 12-14 Amps
if your electrical configu ration does not comply with local and state codes. Ensure compliance by checking with a qualified electrician!
-
Circuit Breaker Requirements
Install your machine on a dedicated circuit to reduce the possibility of tripping the circuit break er. If the circuit breaker frequently trips, have the circuit inspected by a qualified electrician. Never use a larger circuit breaker than stated below, or you will increase the risk of fire.
Circuit Breaker .........................................
15 Amp
Plug Type
The Model G0573 is supplied with an inverted­type 5-15 plug. You must insert an extension cord receptacle over the inverted plug and then insert the male part of the extension cord into a 5-15 wall receptacle.
-
This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two-pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.
Extension Cords
Make sure the cord is rated Standard Service (grade S) or better.
The extension cord must contain a ground wire and plug pin.
-6-
Use at least a 16 gauge cord.
DO NOT use a cord longer than 50 feet!
G0573 Two Speed Floor Air Filter
.
Loading...
+ 16 hidden pages