Grieve Corporation RJ1S User Manual

Ordering Information
Basic Part No. Coil Voltage:
RJ S – C
# of Contacts
1 = SPDT 2 = DPDT
Option
(Blank) = Standard L = LED
Coil V oltage Code
D12 = 12V DC D24 = 24V DC D100 = 100-110V DC A24 = 24V AC A120 = 120V AC A240 = 240V AC
Relays
RJ Series — General Purpose Relays
RJ relays, the newest addition to our relay family, were designed with the same attention-to-detail IDEC is known for. One feature that exem­plifies this is an optional LED. It uses a unique light guide to give you a brighter and more noticeable status indicator from multiple directions.
Key features of the RJ series include:
• Compact size: 12.7 x 27 x 28.8 mm
• Contact rating: 8A (DPDT), 12A (SPDT)
• Operational life: 200K cycles at full resistive load 50 million cycles, no load
• Optional, green, non-polarized LED
• RoHS compliant
RJ1S RJ2S
No. of poles 1 2
Contact Configuration SPDT DPDT
Contact Rating 12A 8A
Contact Material Silver-Nickel alloy
Contact Resistance 50 milliohms max
Operating Time 15 ms max
Release Time 10 ms max
Dielectric Strength
Vibration Resistance
Shock Resistance
Specifications
Mechanical Life
Electrical Life @ Full Rated Load
Operating Temperature -40 to 70º C
Operating Humidity 5 to 85% RH
Dimensions (H x W x D mm) 12.7 x 27 x 28.8
Weight (Approx.) 19g
Between contact and coil 5,000VAC, 1 minute
Between contacts 1,000VAC, 1 minute
Damage limits 10-55Hz, amplitude 0.75mm
Operating extremes 10-55Hz, amplitude 0.75mm
Damage limits
Operating extremes
AC 30,000,000 operations
DC 50,000,000 operations
AC 200,000 operations
DC 100,000 operations
100m/s
1,000m/s
2
min (10G)
2
min (100G)
UL Recognized File No. E555996, Vol 1, sec. 11
CSA Certified File No. LR35144
Consult factory for other voltages.
RJ Series
E
Relays
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC E-3
RJ Series
Type
Contacts Coil Voltage Standard with Indicator Light
SPDT
DPDT
E
Socket Part Numbers (DIN Rail or Panel Mount):
Part Numbers Description
SJ1S-05B SPDT Standard Screw Terminal
Relays
SJ1S-07L SPDT Finger-safe Screw Terminal
SJ2S-05B DPDT Standard Screw Terminal
SJ2S-07L DPDT Finger-safe Screw Terminal
SJ9Z-C Replacement Locking Lever
Relays
Part Numbers
12V DC RJ1S-C-D12 RJ1S-CL-D12
24V DC RJ1S-C-D24 RJ1S-CL-D24
100-110V DC RJ1S-C-D100 RJ1S-CL-D100
24V AC RJ1S-C-A24 RJ1S-CL-A24
120V AC RJ1S-C-A120 RJ1S-CL-A120
240V AC RJ1S-C-A240 RJ1S-CL-A240
12V DC RJ2S-C-D12 RJ2S-CL-D12
24V DC RJ2S-C-D24 RJ2S-CL-D24
100-110V DC RJ2S-C-D100 RJ2S-CL-D100
24V AC RJ2S-C-A24 RJ2S-CL-A24
120V AC RJ2S-C-A120 RJ2S-CL-A120
240V AC RJ2S-C-A240 RJ2S-CL-A240
Coil Ratings at 20ºC (relays with LED indicator)
Coil
Sensitivity
DC Coil
AC Coil (60Hz)
Nominal
Voltage
12V 48mA 271
24V 25.7mA 1,080
100-110V 5.2-5.7mA 18,870
24V 41.1mA 243
240V 4.1mA 21,530
Nominal
Current
Contact Ratings
Resistive Load (Max)
Contact Load Ratings
Contacts Max Power
Allowed
Inductive Load (Max)
Min Applicable Load (reference value) 100mA @ 5VDC 10mA @ 5VDC
Resistive Load (Max)
Inductive Load (Max)
Ratings
Coil Resistance
Power
Consumption
0.53W 70% Max 10% Min
0.9VA 80% Max 30% Min 140%120V 8.1mA 5270
Contact
NO Contact 12A @ 250VAC/30VDC 8A @ 250VAC/30VDC
NC Contact 12A @ 250VAC; 6A @ 30VDC 8A @ 250VAC; 4A @ 30VDC
NO Contact 7.5A @ 250VAC; 6A @ 30VDC 4A @ 250VAC; 4A @ 30VDC
NC Contact 7.5A @ 250VAC; 3A @ 30VDC 4A @250VAC; 2A @ 30VDC
NO Contact AC: 3,000VA; DC: 360W AC: 2,000VA; DC: 240W
NC Contact AC: 3,000VA; DC: 180W AC: 2,000VA; DC: 120W
NO Contact AC: 1,875VA; DC: 180W AC: 1,000VA; DC: 120W
NC Contact AC: 1,875VA; DC: 90W AC: 1,000VA; DC: 60W
Pull-in
Voltage
Drop-Out
Voltage
Max Allowable
RJ1S RJ2S
Voltage
170%
160%
E-4
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC