Grieve Corporation ETR-901 Installation Manual

INSTRUCTION MANUAL
MANUAL NO. 17
48mm, 1/16 DIN Solid State Temperature
Controller - Relay Output - Solid State
Output - For Heating -
Model Series: ETR-901, ETR-902, ETR-905
ETR-901
ETR-902
ETR-905
25
32” (45mm) square. Aminimum of 4” (102mm) in depth is required for electrical clearances of rear terminal connections. The following specifications are common to all models:
INPUT
Thermocouple (T/C): Type K, J. Specified on
Control Label.
RTD: PT 100 ohm DIN (
=
.00385) or JIS (
=
.00392) Two or Three-Wire.
Cold Junction Automatic
Compensation:
Input Break Protection: Built-in, upscale on open
sensor and output off. Input Impedance: 10M ohm. Common Mode
Rejection (CMR): CMRR 120 dB, Min.
Normal Mode
Rejection (NMR): NMRR 60 dB, Min. (60Hz)
CONTROL OUTPUT
Relay–Heating: SPDT relay, 3 amps
maximum resistive load at
120V/240VAC, 24VDC.
Optional: 3-32VDC: For control of solid state
relay.
CONTROL MODES
On-Off: Hysteresis: 5.0% of scale
symmetrically above and below the set point.
Proportional: Proportional Band fixed at
5% of scale. Standard relay cycle time, 20 seconds. 1 second for SSR controls.On ETR-905, manual reset is 4% of scale, externally adjustable.
INDICATION
Output: Red LED, heater on.
Green LED, heater off.
SET POINT
Resolution: ETR-901, 902: 0.2% of
SPAN.
ETR-905: least significant
digit.
Accuracy: ETR-901, 902: 0.2% of
SPAN.
ETR-905: least significant
digit.
2
Mounting Dimensions
Lead Termination
MANUAL RESET ADJUSTMENT
(Applies to the ETR-905 only.)
When the process stabilizes, approximately one half hour after adjusting set point, an adjustment in reset may also be necessary. Start with the reset adjustment pointing to zero. If the temperature indication stabilizes above the set point temperature, then adjust the reset to the minus side. If the temperature indication stabilizes below the set point temperature, then adjust to the plus side. By turning this adjustment once or more, the indicated temperature should eventually match the set point temperature. It is very important to wait approximately 15 minutes after each adjustment to allow the system to stabilize.
WIRING
All wiring should conform to local and national codes:
Following Diagrams for ETR-901 and ETR-902 Models:
(Do not operate 120 volt controls on 240 volts.)
Diagram 1: For 120VAC operation and relay output.
An external magnetic contactor must be used if the heater load exceeds 360 watts.
Diagram 2: For 120VAC operation and 3-32VDC
output. For use with solid-state relay for heater control. Solid-state relays can be single or three-phase.
Following Diagrams for ETR-905 Model:
Diagram 3: For 90-264VAC operation and relay
output. An external magnetic contactor must be used if the heater load exceeds 3 amps.
Diagram 4: For 90-264VAC operation and 3-32VDC
output. For use with a solid-state relay for heater control. Solid-state relays can be single or three-phase.
NOTE: The use of motor starters in place of magnetic contactors should be avoided. They have very large inductive loads that can damage the controllers relay.
POWER
Rating: ETR-901 and 902 models
110/220VAC
NOT field
selectable ±15%, 50/60Hz.
ETR-905 model 90-
264VAC. 24V AC/DC
models available on special
order.
Consumption: Less than 3VA.
ENVIRONMENTAL & PHYSICAL
Operating Temperature: 10° to 125°F (-12 to 52°C). Humidity: 10 to 90% RH (non-
condensing). Insulation: 20M ohm Min, (5000VDC). Breakdown: 2000VAC, 50/60Hz,
1 minute. Vibration: 10 - 55Hz, Amplitude
1.0mm.
Shock: 660 ft./S
2
(20g).
Weight: 9 oz. (250 grams)
DIMENSIONS
H 17⁄8” (48mm)
W 17⁄8” (48mm)
D 33⁄4” (95mm)
Depth behind panel 33⁄8
(86mm)
Panel Cutout: 1
25
32” sq. (45mm sq.)
DIN Case: Plastic, full plug-in
construction, with screw
terminals on rear,
adjustable brackets for
panel mounting.
MOUNTING
When mounting the instrument, it is important the control remains within the ambient temperature range of 10 to 125°F. Mounting it in any position is permissi­ble. After inserting the control into the panel, secure it with the two mounting brackets provided with each unit.
Mounting Bracket
1-25/32"
(45mm)
1-25/32"
(45mm)
Panel Cutout
Panel
3 3/8"
(86mm)
3 3/4"
(95mm)
9/16"
5/16"
SPADE TONGUE CONNECTOR FOR NO. 6 STUD
3/8"
20 Ga. Wire