Grieve Corporation BJDP1 User Manual

160T01005 030220
Standard terminal blocks
Compression clamp
DIN 1 - 3
A
1
Test connector : see section connectors
End stop th. 9 mm BADL V0 End stop th. 9,1 mm BAM V2 End stop Rail Rail Rail Rail
th. 9,1 mm BAM V0 V0 35 x 7,5 x 1 PR3.Z2 35 x 15 x 2,3 PR4 35 x 15 x 1,5 PR5 32 x 15 x 1,5 PR1.Z2
Other end stops, rails and accessories : see section on accessories.
Characteristics
Wire size
IEC UL CSA
Compression Sol id wi re
clamp
Stranded wire
NFC DIN
0,2-4 mm² 22-10 AWG 22-10 AWG
0,22-4 mm² 22-10 AWG 22-10 AWG
Voltage
Rated Pulse Pollution degree
800 V 600 V 600 V
8 kV
3
Current
Rated
32 A 30 A 25 A
Wire size
Rated / Gauge
Wire strip. Recomm. Recomm. Protection
length Screwdriver torque
9,5 mm 4 mm 0,5-0,8 Nm IP 20
.37" .157" 4.4-7.1 lb.in. NEMA 1
4 mm² / A4 10 AWG 10 AWG
Notes
The use of some accessories may decrease the block's voltage rating. For more information, consult us.
BJDP1 permits the interconnection with a terminal block series "M" spacing 16 mm. BJDP3 permits the interconnection with a terminal block series "M" spacing 12 mm. BJDP4 permits the interconnection with a terminal block series "D" spacing 8 mm or a terminal block series "M" spacing 8 or 10 mm.
10
0399 903.02 0103 002.26 0199 306.03 0174 300.17 0168 500.12 0168 700.22 0163 050.04
Spacing 6 mm + 0,05 (.238")
Standard 6 mm block
Accessories
1
2
3
4
5
11
6
7
9
13
14
15
18
21
23
25
27
28
8
12
10
16
17
19
20
22
24
26
29
R
M 4/6...
Colour Type Part numbers
Standard blocks
Grey Blue Orange Yellow Green Red Black White Brown Beige V0 Blue V0
0115 116.07 0125 116.01 0105 002.20 0105 116.16 0105 001.27 0105 032.15 0105 031.14 0105 051.20 0105 209.14 0195 116.00 0199 002.26
0115 116.07
Type Part numbers
1 End section grey
orange
2 End section grey 3 End section grey 4 Circuit separator grey
5 Separator end section grey
6 Separator end section grey 7 Separator end section grey 8 Separator end section grey 9 Separator end section grey
10 Separator end section grey
(for cover CPV) beige
11 Protective cover 12 Protective cover 13 Test socket
14 Test device 15 Test plug
Assembled jumper bar 32 A
16
(without IP20 protection) 32 A
17
Assembled jumper bar 32 A (with IP20 protection) 32 A
18
Jumper bar not assembled 32 A Post + screw + washer
19 Connector plate 20 Screwless jumper bar 32 A
orange IP 20 32 A
21 Jumper 22 Pivoting jumper bar 35 A 23 Alternated jumper bar 35 A 24 Universal jumper bar
25 Comb-type jumper bar 35 A
Insulating tip
26 Shield connector
27 Protection label
Screw for protection label
28 Protection label 29 IDC jumper
See section on markers method
R
FEM6 2,8 mm
blue
FEM6 2,8 mm FEM6 2,8 mm
yellow
FEM6 2,8 mm
green
FEM6 2,8 mm
white
FEM6 2,8 mm
beige
FEM6 V0 V0 2,8 mm
blue
FEM6 V0 V0 2,8 mm
yellow
FEM6 V0 V0 2,8 mm FEM61 (3) 3,0 mm FEM6C (3) 3,0 mm SCM6
blue
SCM6
beige
SCM6 V0 V0 SCF6 3,0 mm
blue
SCF6 3,0 mm
beige
SCF6 V0 V0 3,0 mm SCF61 3,0 mm SCFM6 (3) 3,0 mm SCFEX1 (3) SCFEX3 (3) SCFCV1-2 (3) 3,0 mm SCFCV1-2 V0(3)V0 3,0 mm CPM CPV1-2
(for FEM6C, SCF6(V0) and SCFM6)
(for SCFCV1-2...) AL2 (1) 2 mm AL3 (1) 3 mm DCJ FC2 2 mm FC4 4 mm BJM6 (1) 2 BJM6 (1) 3
32 A
BJM6 (1) 4
32 A
BJM6 (1) 5
32 A
BJM6 (1) 10 BJMI6 (1) 2 BJMI6 (1) 3
32 A
BJMI6 (1) 4
32 A
BJMI6 (1) 5
32 A
BJMI6 (1) 10 BJS6 (1) 20 EV6
35 A
EL6 BJE6.2 (4) 2 BJE6.3 (4) 3
32 A
BJE6.4 (4) 4
32 A
BJE6.5 (4) 5
32 A
BJE6.10 (4) 10 BJB BJP6 (1) BJA6 (1) 10
50 A 70 A 50 A
BJDP1 (1)(2) BJDP3 (1)(2) BJDP4 (1)(2)
spacing 6 <-> spacing 16 spacing 6 <-> spacing 12 spacing 6 <-> spacing 8 or 10
PC6 (4) 2
35 A
PC6 (4) 10 EIP CBM5 0,5 mm CBM8 0,8 mm EP6 4 VSP6 EPU6 AD2,5
11 12
th. th. th. th. th. th. th. th. th. th. th.
th. th. th. th. th. th. th. th. th.
DIA. DIA.
DIA. DIA.
th. th.
2,4 mm 2,4 mm
yellow
poles poles poles poles poles poles poles poles poles poles poles
poles poles poles poles poles
poles
poles poles
blocks
0118 368.16 0128 368.10 0103 126.16 0103 062.21 0103 125.15 0103 312.20 0198 368.17 0199 302.07 0199 305.02 0114 776.23 0114 777.24 0113 003.10 0123 003.12 0193 003.11 0118 707.03 0128 707.05 0198 707.04 0114 202.25 0114 825.05 0103 619.04 0103 620.01 0116 795.11 0196 795.12 0187 312.14 0176 816.12 0163 043.21 0163 261.00 0173 059.03 0007 865.26 0167 860.01 0168 516.25 0168 517.26 0168 518.07 0168 519.00 0168 973.07 0176 663.00 0176 664.01 0176 665.02 0176 666.03 0176 667.04 0174 784.20 0168 604.16 0173 627.21 0299 694.04 0299 695.05 0299 696.06 0299 697.07 0299 702.14 0199 466.23 0174 413.14 0116 541.12 0179 623.03 0179 625.05 0174 781.25 0113 546.14 0113 548.26 0113 550.24 0178 745.14 0178 746.15 0163 427.17 0163 433.15 0107 038.25 0114 205.20
Note : (1) A circuit separator SC may be required with the use of these accessories.
(2) See "Notes". (3) End sections and separators snapped on rails. (4) See section : "Accessories" for other configurations of poles.
ABB Entrelec