Because of the variety of uses for the products described in this publication,
those responsible for the application and use of this control equipment must
satisfy themselves that all necessary steps have been taken to assure that each
application and use meets all performance and safety requirements, including
any applicable laws, regulations, codes and standards.
The illustrations, charts, sample programs and layout examples shown in this
guide are intended solely for purposes of example. Since there are many
variables and requirements associated with any particular installation,
Allen-Bradley does not assume responsibility or liability (to include intellectual
property liability) for actual use based upon the examples shown in this
publication.
Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley
office), describes some important differences between solid-state equipment
and electromechanical devices that should be taken into consideration when
applying products such as those described in this publication.
Reproduction of the contents of this copyrighted publication, in whole or part,
without written permission of Rockwell Automation, is prohibited.
Throughout this manual we use notes to make you aware of safety
considerations:
ATTENTION
Identifies information about practices or circumstances
that can lead to personal injury or death, property damage
or economic loss
!
Attention statements help you to:
• identify a hazard
• avoid a hazard
• recognize the consequences
IMPORTANT
Allen-Bradley is a trademark of Rockwell Automation
Identifies information that is critical for successful
application and understanding of the product.
European Communities (EC)
Directive Compliance
If this product has the CE mark it is approved for installation within the
European Union and EEA regions. It has been designed and tested to meet
the following directives.
EMC Directive
This product is tested to meet the Council Directive 89/336/EC
Electromagnetic Compatibility (EMC) by applying the following standards, in
whole or in part, documented in a technical construction file:
• EN 50081-2 EMC — Generic Emission Standard, Part 2 — Industrial
Environment
• EN 50082-2 EMC — Generic Immunity Standard, Part 2 — Industrial
Environment
This product is intended for use in an industrial environment.
Low Voltage Directive
This product is tested to meet Council Directive 73/23/EEC Low Voltage,
by applying the safety requirements of EN 61010-1 safety requirements for
electrical equipment for measurement, control and laboratory use--Part 1
General Safety Requirements.
This equipment is classified as open equipment and must be mounted as
instructed in an enclosure during operation to provide safety protection.
Preface
Manual Objectives
Who Should Use This
Manual
Counter/Timer Mode
Explanation
The purpose of this manual is to provide you with the additional information
necessary to apply the 700-HX Multifunction Digital Timer. Described in this
manual are methods for applying and troubleshooting this product.
This manual is intended for qualified personnel responsible for setting up and
servicing these devices. You must have previous experience with and a basic
understanding of wiring diagrams, configuration procedures, related
equipment, and safety precautions.
In this manual we refer to the Timer Output Modes with the following
designations:
A: Signal ON delay 1
A-1: Signal ON delay 2
A-2: Power ON delay 1
A-3: Power ON delay 2
For Further Information
B: Repeat cycle 1
B-1: Repeat cycle 2
D: Signal OFF delay
E: One Shot
F: Cumulative
Z: ON/OFF-duty adjustable repeat cycle
toff: Repeat cycle OFF start
ton: Repeat cycle ON start
Note: In this manual the 700-HX Multifunction Digital Timer will be referred
to as “700-HX.”
Relays and Timers Selection Guide
• Publication 700-SG003A-EN-P
1Publication 70 0-UM002 A-EN-D July 2001
Product Overview
Chapter
1
Bill of Material
Your 700-HX Multifunction Digital Timer product package includes the
following items:
A mode: Signal ON-Delay 1
A-1 mode: Signal ON-Delay 2
A-2 mode: Power ON-Delay 1
A-3 mode: Power On-Delay 2
B mode: Repeat Cycle 1
B-1 mode: Repeat Cycle 2
D mode: Signal OFF-delay
E mode: One Shot
F mode: Cumulative
Z mode
toff
ton
0.000…9.999 s
0.000…99.99 s
0.000…999.9 s
0.000…9999 s
0.000…99 min. 59 s
0.000…999.9 min.
0.000…9999 min.
0.000…99 h 59 min.
0.000…999.9 h
0.000…9999 h
700-HN100
700-HN125
SPDT8
1Publication 700-UM002A-EN-D - July 2001
1-2 Product Overview
Accessories
(Order Separately)
Cat. No.DescriptionPkg. Qty.
70 0-HN100Screw Terminal Tube Base Sockets — Panel or DIN Rail
Mounting Guarded Terminal Construction
8-pin for use with Bulletin 700-HX timing relays. Order
must be for 10 sockets or multiples of 10.
70 0-HN125Screw Terminal Tube Base Sockets — Panel or DIN Rail
Mounting
Open Style Construction
8-pin for use with Bulletin 7 00-HX t iming relays. Order must
be for 10 sockets or multiples of 10. No retainer clip
required.
19 9-DR1DIN Rail Mounting Pack
Standard 35 x 7.5 mm DIN Rail, 1 meter long, 10 rails per
package. Order must be for 10 rails or multiples of 10.
700-HN108Specialty Socket
8-pin backwired socket with solder terminals for use with
Bulletin 700-HX timing relays. Order must be for 10 sockets
or mult iples of 10 .
70 0-HN130Frame Adapter
For flush or door mounting of all Bulletin 700-HR and -HX
timers.
700-HN132Protective Cover
Helps prevent tampering of timing and mode settings.
Provides a degree of protection against water and dirt from
entering the front of the relay. For use with all Bulletin
700-HRs and -HX timing relays.
70 0-N40Pre-printed identification tags— contains 10 sheets of
pre-printed and blank tags. Each sheet contains 13 sets of
the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and
117 blank tags. Tags are peel-off with sticky backing for
easy placement on relays.
10
10
10
10
1
1
10
Publication 700-UM002A-EN-D - July 2001
70 0-N41Blank identification t ags— contains 1 0 sheets of blank
identification tags for customer specialized printing. Each
sheet contains 546 blank tags. Tags are peel-off with sticky
backing for easy placement on relays.
10
Product Features
Chapter
2
Block diagram
I/O Functions
Output circuit
(Basic
insulation)
Display circuit
Input circuit
Note: Power circuit is not insulated from the input circuit.
In putsStart signalStops t iming in A-2 and A-3 (power ON delay)
ResetResets present value. (In elapsed time mode, the
Gate ➊Inhibits timer operation.
OutputsControl ou tput (OUT)Outputs take place according to designated
Internal control
circuit
Power supply
circuit
modes.
Start timing in other modes.
present value returns to 0; in remaining time
mode, the present value returns to the set value.)
Count inputs are not accepted and control out put
turns OFF while reset input is ON.
Reset indicator is lit while reset input is ON.
operating mode when timer reaches
corresponding set value.
Key switch
circuit
(See note.)
➊ Gate capability not available.
1Publication 700-UM002A-EN-D - July 2001
2-2 Product Features
Engineering Data
(Reference Values)
)
4
1,000
500
100
50
Switching operations ( 10
10
250V A C cos =0.4
0 123 45
30V DC L/R=7 ms
Specifications
250V DC/30V
cos =1
Load current (A)
Reference:A maximum current of 0.15 A can be switched
at 125V DC (cosφ=1) and a maximum current of 0.1 A
can be switched if L/R is 7 ms. In both cases, a life of
100,000 operations can be expected. The minimum
applicable load is 10 mA at 5V DC (failure level: P).
Electrical Ratings
Pilot Duty RatingNEMA B300
Rated supply voltage100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible
ripple: 20%(p-p) max.)
Operating voltage range85%…110% of rated supply voltage
Power consumption100…240V AC
24V AC/12…24V DC
Inrush Current100…240V AC
24V AC/12…24V DC
120V AC
4.3 VA
3.4 VA/1.7 W
3 A
5 A
30 A
15 A
Make 240V AC
120V AC
3 A
1.5 A
Break 240V AC
Hp at 120V AC1/4 Hp
Hp at 240V AC1/3 Hp
Mechanical
Mounting methodFlush mounting, surface mounting, DIN mount ing
Display7-segment, negative transmissive LCD;
Present value (red, 8 mm high characters); Set value (green,
4 mm high characters)
Digits4 digits
TimerTime ranges0.000…9.999 s, 0.00…99.99 s, 0.0…999.9 s, 0…9999 s,
0 min. 0.0 s…99 min. 59 s, 0.0…999.9 min., 0 h 00 min.…99
h 59 min., 0.0 h…999.9 h, 0 h…9999 h
Timer modesElapsed time (Up), remaining t ime (Down), selectable
Output modesA, A-1, A-2, A-3, B, B-1, D, E, F, Z, ton or toff
Input methodNo-voltage input via:NPN transistor or switching of contact
Start , reset, gateMinimum input signal width: 1 or 20 ms (selectable)
Power resetMinimum power-opening time: 0.5 s (Except for A-3, B-1, and
F mode)
Control outputSPDT contact output: 5 A at 250V AC, resistive load
(cosine=1)
Minimum applied load: 10 mA at 5V DC (failure level: P,
reference value)
External Power SupplyNo
Key ProtectYes
Memory backupEEP-ROM (overwritten 100,000 times min.), which can store
data for 2 0 years min.
Accuracy of Operating Time and Setting Error ➊Power-ON start: +-0.01% +-50 ms max.*
* to be rated against set value
Signal start: +- 0.005 +-30 ms max. *
* to be rated against set value
Signal start at transistor out put model: +- 0.005% +-3 ms
max. ➋
If the set value is within the sensor waiting time
(250 ms max.)
➊ The values are based on the set value.
❷ The value is applied for a minimum pulse width of 1 ms.
Characteristics
Insulation resistance100 MΩ min. (at 500V DC)
Diele ctric strength20 00V AC, 50/60Hz for 1 min. between current-carrying terminals and
non-current-carrying metal parts
(1000V AC for 24V AC/12 to 24V DC type),
10 00V AC, 50/60 Hz for 1 min. between non-continuous contacts
Noise immunity'+-1.5 kV (between power terminals) for 100 to 240V AC, +-480V for 24V AC/12
to 24VDC, and +-600V (between input terminals), square-wave noise by noise
Vibr ation resistanceMalfunction10 …55 Hz with 0 .35 mm single amplitude each in three directions for 10 min.
Shock resistanceMalfunction
Life e xpectancyMechan ical10 million operations min.
Electrical10 0,0 00 operations min. (5 A at 250V AC, resistive load)
EMC(EMI) EN61326
2
(approx. 10 G) each in three directions
98 m/s
Emission Enclosure: EN55011 Group1 class A
Emission AC mains: EN55011 Group1 class A
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level2)
8 kV air discharge (level3)
Immunity RF-interference: EN61000-4-3: 10 V/m
Publication 700-UM002A-EN-D - July 2001
2-4 Product Features
Approved standardsUL508, CSA C22.2 No.14
Conforms to EN61010-1/IEC61010-1
(Pollution degree 2/ overvoltage category II)
Conforms to VDE0106/P 100 (Finger Protection), conforms to NEMA output
rating (N/F)
Enclosure rat ingsPanel surface:IP66 and NEMA Type 4 (indoors) ➊
WeightApprox. 100 g
➊
An attached waterproof packing is necessary to ensure IP66 waterproofing between the
700-HX and installation pan.
Nomenclature
Indicator
A Reset Indicator (orange)
B Key Protection Indicator (orange)
C Control Output Indicator (orange)
D Present Value
Character height: 11.5 mm
E Time Unit Display (orange):
(If the time range is 0 min, 0 h, 0.0 h,
or 0 h 0 min, this display flashes to
indicate timing operation.)
F Set Value (green)
Character height: 6 mm
G Set Value 1, 2 Display
Operation Key
D
A
B
C
G
H
I
E
F
J
K
Front View
H Mode Key
(Changes modes and setting items)
I Reset Key
(Resets present value and output)
J Up Keys 1 to 4
K Down Keys 1 to 4
Front color: Gray
Switches
LM
L Key-protect Switch
(default setting) OFF
ON
M DIP Switch
Case color: Gray
Publication 700-UM002A-EN-D - July 2001
Settings for Advanced
9
Functions
Power ON
Run mode
See note 1.See note 2.
3 s min.3 s min.
Functions
For details on operations in run mode, refer to 3-9.
Note:1. If the mode is switched to the function setting mode during operation,
operation will continue.
2. Changes made to settings in function setting mode are enabled for the
first time when the mode is changed to run mode. Also, when settings
are changed, the timer is reset (time initialized and output turned OFF).
Press the mode button for several seconds to display the Time Range setting
screen.
Chapter
3
Function setting mode
Set the time range using the keys.
Time range
s
Timer mode
Output mode
Output time
Input signal
width
Key protect
level
Set the timer mode using the keys.
Set the output mode using the keys.
Set each digit for the output time using the corresponding keys.
(If the output time is set to 0.00, is displayed.)
Displayed for modes A, A-1, A-2, A-3, B, and B-1 only.
Set the key protect level using the keys.
sshs
iA-1 jiA-2 jiA-3 jib-1 jib jid jiE jiF jiZ jiA j
‘
i1 ms ji20 ms j
cc
Time Range List
Display
Set Value
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9,999 s
0 min 01 s to 99 min
0.1 min to 999.9 min
1 min to 9,999 min
0 h 01 min to 99 h 5
0.1 h to 999.9 h
1 h to 9,999 h
0.001s to 9.999 s
1Publication 700-UM002A-EN-D - July 2001
3-2 Functions
Explanations of Functions
Time Range (
Set the range to be timed in the range 0.000 s… 9,999 h. Use the operation
keys if these settings are required.
Timer Mode (
Set either the elapsed time (UP) or remaining time (DOWN) mode.
Output Mode (
Set the output mode. The possible settings are A, A-1, A-2, A-3, B, B-1, D, E,
F, and Z. (For details on output mode operation, refer to “Timing Charts” on
page 3-10.)
Output Time (
When using one-shot output, set the output time for one-shot output (0.01…
99.99 s). One-shot output can be used only if the selected output mode is A,
A-1, A-2, B, or B-1. If the output time is set to 0.00, hold is displayed, and the
output is held.
timr
timm
outm
otim
)
)
)
)
Input Signal Width (
Set the minimum signal input width (20 ms or 1 ms) for signal and reset
inputs. The same setting is used for all external inputs (signal and reset). If
contacts are used for the input signal, set the input signal width to 20 ms.
Processing to eliminate chattering is performed for this setting.
Key Protect Level (
Set the key protect level.
When the key-protect switch in set to ON, it is possible to prevent setting
errors by prohibiting the use of certain operation keys by specifying the key
protect level (KP-1 to KP-5). The key protect indicator is lit while the
key-protect switch is set to ON. Confirm the ON/OFF status of the
key-protect switch after the 700-HX is mounted to the panel.
iflt
kypt
)
)
Publication 700-UM002A-EN-D - July 2001
Functions 3-3
(See note)
Note: Factory-set to OFF
ON
OFF
Key protect indicator
LevelMeaning
KP-1
(default
setting)
Prohibits changing the mode to timer/ twin
timer selection mode or function setting
mode. The 700-HX can only be used in run
mode.
KP-2Prohibits changing the mode to timer/twin
timer selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of the reset key.
KP-3Prohibits changing the mode to timer/twin
timer selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of the up and down
keys.
KP-4Prohibits changing the mode to timer/twin
timer selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of the reset, up and
down keys.
KP-5Prohibits changing the mode to timer/twin
timer selection mode or function setting
mode. The 700-HX can only be used in run
mode. Also prohibits use of any operation
keys.
Publication 700-UM002A-EN-D - July 2001