Greisinger GTMU - MP User guide

WEEE-Reg.-Nr.: DE93889386
T20.0.4X.6C-03
Transmitter for temperature
from version V3.2 Operating Manual GTMU - MP
Content
1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT OF ELBOW-TYPE PLUG (DEPENDING ON TYPE) 3 6 GENERAL INSTALLATION INSTRUCTIONS: 3 7 DESIGN TYPES, DIMENSION 3 8 DISPLAY FUNCTIONS 4
8.1 MEASURING DISPLAY 4
8.2 MIN/MAX VALUE MEMORY 4
9 ERROR AND SYSTEM MESSAGES 4 10 CONFIGURATION OF THE DEVICE 5 11 NOTES TO THE CALIBRATION SERVICES 6 12 SPECIFICATION 6
GREISINGER electronic GmbH
D - 93128 Regenstauf, Hans-Sachs-Straße 26
+49 (0) 9402 / 9383-0+49 (0) 9402 / 9383-33 info@greisinger.de
T20.0.4X.6C-03 Operating Manual GTMU - MP page 2 of 6
This device must not be disposed as “residual waste”. To dispose this device, please send it directly to us (adequately stamped). We will dispose it appropriately and environmentally friendly.
_____________________________________________________ _____________________________________________________________________________
1 Intended use
The device measures the temperature of air or non corrosive / non ionizing gases. The safety instructions (see chapter 3) have to be observed.
The device must not be used for purposes and under conditions for that the device had not been designed. The device must carefully dealt with and has to be used according to the specifications (do not throw, knock, etc.). It has to be protected against dirt. Do not expose the sensor to aggressive gases (like ammonia) for longer time. Avoid condensation, as after drying there may remain residues, which may affect the precision negatively. In dusty environment additional protection has to be applied (special protection caps).
2 General advice
Read through this document attentively and make yourself familiar to the operation of the device before you use it. Keep this document in a ready-to-hand way in order to be able to look up in the case of doubt.
3 Safety instructions
This device has been designed and tested in accordance to the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using it.
1. Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected to any other climatic conditions than those stated under “Specification”. Transporting the device from a cold to a warm environment condensation may result in a failure of the function. In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up.
2. General instructions and safety regulations for electric, light and heavy current plants, including domestic safety regulations (e.g. VDE), have to be observed.
3. If device is to be connected to other devices (e.g. via PC) the circuitry has to be designed most carefully. Internal connection in third party devices (e.g. connection GND and earth) may result in not-permissible voltages impairing or destroying the device or another device connected.
4. Whenever there may be a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may be a risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer time
In case of doubt, please return device to manufacturer for repair or maintenance.
5. Warning: Do not use this product as safety or emergency stop device or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage.
4 Disposal notes
Loading...
+ 4 hidden pages