Greenheck WTHD series, WTHD-10, WTHD-8, WTHD-14, WTHD-12 Assembly And Installation Instructions Manual

...
PN 472040
1
2
3
4
6
7
1
2
3
4
6
7
1
2
3
4
11
11
10
5
9
7
8
6
C
A
B
D
E
C
D
A
B
D
E
Model WTHD
45° and 90° Weatherhood Accessory
Assembly and Installation Instructions
Assembly and Installation Instructions
Please read and save these instructions for future reference. Read carefully before attempting to
Please read and save these instructions for future reference. Read carefully before attempting assemble, install, operate or maintain the product described. Protect yourself and others by observing
to assemble, install, operate or maintain the product described. Protect yourself and others by all safety information. Failure to comply with instructions could result in personal injury and/or property
observing all safety information. Failure to comply with instructions could result in personal injury damage! Upon receiving unit, check for any damage that may have occurred during transit and report it
and/or property damage! immediately to the shipper. Also verify that all accessory items are accounted for.
Weatherhood Parts List
Parts 45° 90°
1 Top Panel 2 Right Side Panel 3 Left Side Panel 4 Front Diagonal Panel 5 Front Panel 6 Bottom (Brace or Panel) 7 Birdscreen 8 Right Deflection Angle
9 Front Deflection Angle 10 Left Deflection Angle 11 Reinforcing Braces (sizes 54-72 only) 12 Fasteners
     
 
   
Figure 1: 45° Weatherhood
Weatherhood Dimensions
Model A B C D
WTHD-8 111⁄4 (286) 101⁄2 (267) 1 (25) 131⁄4 (337) WTHD-10 133⁄8 (340) 121⁄2 (318) 1 (25) 15 (381) WTHD-12 155⁄8 (397) 141⁄2 (368) 11⁄4 (32) 161⁄2 (419) WTHD-14 175⁄8 (448) 161⁄2 (419) 11⁄4 (32) 18 (457) WTHD-16 195⁄8 (498) 181⁄2 (470) 11⁄4 (32) 191⁄2 (495)
WTHD-18 215⁄8 (549) 201⁄2 (521) 11⁄4 (32) 22 (559) WTHD-20 235⁄8 (600) 221⁄2 (572) 11⁄4 (32) 25 (635) WTHD-24 303⁄8 (772) 29 (737) 11⁄2 (38) 27 (686) WTHD-30 361⁄2 (927) 35 (889) 11⁄2 (38) 291⁄4 (743) WTHD-36 421⁄2 (1080) 41 (1041) 11⁄2 (38) 331⁄4 (845)
45° Weatherhood
WTHD-42 481⁄2 (1232) 47 (1194) 11⁄2 (38) 36 (914) WTHD-48 543⁄4 (1391) 531⁄4 (1353) 15⁄8 (41) 405⁄8 (1032) WTHD-54 607⁄8 (1546) 591⁄2 (1511) 11⁄2 (38) 443⁄4 (1137) WTHD-60 67 (1702) 651⁄2 (1664) 11⁄2 (38) 48 (1219) WTHD-72 791⁄2 (2019) 781⁄8 (1984) 11⁄4 (32) 531⁄4 (1353)
WTHD-8 12 (305) 105⁄8 (270) ¾ (19) 163⁄8 (416) WTHD-10 14 (356) 123⁄4 (324) ¾ (19) 181⁄2 (470) WTHD-12 163⁄8 (416) 151⁄2 (394) ¾ (19) 203⁄8 (518) WTHD-14 183⁄8 (467) 171⁄2 (445) ¾ (19) 221⁄2 (572) WTHD-16 203⁄8 (518) 191⁄2 (495) ¾ (19) 25 (635) WTHD-18 223⁄8 (568) 211⁄2 (546) ¾ (19) 271⁄2 (699) WTHD-20 243⁄8 (619) 231⁄2 (597) ¾ (19) 293⁄4 (756) WTHD-24 313⁄4 (806) 285⁄8 (727) 11⁄2 (38) 36 (914) WTHD-30 377⁄8 (962) 345⁄8 (879) 11⁄2 (38) 401⁄8 (1019) WTHD-36 437⁄8 (1114) 405⁄8 (1032) 11⁄2 (38) 451⁄2 (1156)
90° Weatherhood
WTHD-42 497⁄8 (1267) 465⁄8 (1184) 11⁄2 (38) 491⁄4 (1251) WTHD-48 56 (1422) 523⁄4 (1340) 11⁄2 (38) 551⁄2 (1410) WTHD-54 621⁄4 (1581) 59 (1499) 11⁄2 (38) 611⁄8 (1553) WTHD-60 683⁄8 (1737) 651⁄8 (1654) 11⁄2 (38) 661⁄2 (1689) WTHD-72 807⁄8 (2054) 771⁄2 (1969) 11⁄2 (38) 721⁄8 (1832)
All dimensions shown in inches (millimeters).
Figure 2: 90° Weatherhood
Figures 3 – 5: Weatherhood Dimensions
Sidewall Propeller Fans • 45° and 90° Weatherhood Accessory
1
®
45° Weatherhood Assembly
1. Refer to Figure 1 to identify parts for assembly.
2. Assemble front diagonal panel (4) to right side panel (2) with 5/8 inch (16 mm) length sheet metal screws. Overlap the ange on the front diagonal panel (4), over the right side panel (2).
3. Repeat step 2 for left side panel (3).
4. As shown in Figure 6, assemble the top panel (1) to the front diagonal panel (4) and side panels (2 & 3) overlapping with the anges. Use 5/8 inch (16 mm) length supplied sheet metal screws.
1
4
Figure 6: Assembly
3
6
2
90° Weatherhood Assembly
1. Refer to Figure 2 to identify parts for assembly.
2. Using #12 x 5/8 inch (16 mm) screws, attach side panels (2 & 3) to front panel (5). Overlap the sides with the ange of the front panel.
3
2
5
Figure 8: Assembly
3. Secure the front diagonal panel (4) using #12 x 5/8 inch (16 mm) screws to the front panel (5) and side panels (2 & 3). Overlap the front panel (5) and side panels (2 & 3) with anges of the front diagonal panel (4).
5. Install the bottom panel (6) to the sides using the 5/8 inch (16 mm) length sheet metal screws. Place the bottom panel (6) inside each anged side.
6. Refer to Figure 7 and slide the birdscreen into the bottom of the assembled weatherhood through the openings on the underside. Place birdscreen in the frame and rest on the anges on each side. Fasten screen to each side using the 5/8 inch (16 mm) length sheet metal screws.
Swing birdscreen down into position
Insert birdscreen upward
4
Figure 9
4. Attach top panel (1) to the front diagonal panel (4) and side panels (2 & 3) using #12 x 5/8 inch (16 mm) screws. Overlap the front diagonal (4) and side panels (2 & 3) with the anges of the top panel (1).
1
4
Birdscreen
Figure 7: Insert Birdscreen
2
Sidewall Propeller Fans • 45° and 90° Weatherhood Accessory
2
Figure 10
®
5. Install bottom brace (6) to the inside of side panels (2 & 3) using #12 x 5/8 inch (16 mm) screws.
Figure 11
6
7. Slide birdscreen into the assembled weatherhood through the notches on the underside of the side panels (2 & 3). Work the screen in so the frame of the screen rests on the anges of the front panel (5) and side panels (2 & 3), and bottom brace (6).
7
5a. For sizes 54-72 only: Install reinforcing braces
(11) to the inside of side panels (2 & 3) using #12 x 5/8 inch (16 mm) screws.
11
Figure 12
6. Mount assembled weatherhood to the unit.
Figure 13: Wall Housing
Figure 16: Insert Birdscreen
8. Fasten front and side deectors (8-10) to the front (5) and side panels (2 & 3) and birdscreen with #12 x 3/4 inch (19 mm) tek screws.
10
9
8
Figure 17
Figure 14: Wall Collar
Figure 15: Wall Opening
Sidewall Propeller Fans • 45° and 90° Weatherhood Accessory
3
®
Typical Installation
W.O.
Wall
W.O.
W.O.
Wall
Wall
W.O.
W.O.
W.O.
Wall
Wall
Wall
DANGER
Always disconnect, lock and tag power source before installing or servicing. Failure to disconnect power source can result in re, shock or serious injury.
1. Move weatherhood to desired location.
2. Weatherhood may be mounted directly to the wall or to the fan wall housing or wall collar.
NOTE: Units mounted directly to the wall require a different wall opening (W.O.) size than those mounted in wall housings or wall collars.
DIRECT TO WALL
1. Cut an appropriate sized hole in the wall using the recommended wall opening (W.O.).
2. For a weathertight seal, add silicone to the ange prior to mounting.
3. Mount weatherhood directly to the wall using corrosion-resistant fasteners.
MOUNT TO WALL HOUSING OR WALL COLLAR
1. Cut an appropriate sized hole in the wall using the recommended wall opening (W.O.).
2. For a weathertight seal, add silicone to the ange prior to mounting.
3. Mount weatherhood to the wall housing or wall collar using corrosion-resistant fasteners.
Figure 19: With Wall Housing
Figure 18: Direct To Wall
Recommended Wall Opening (W.O.)
Direct To Wall, see Figure 18
Model
WTHD-8 10½ WTHD-10 12½ (318) WTHD-12 14½ (368) WTHD-14 16½ (419) WTHD-16 18½ (470) WTHD-18 20½ (521) WTHD-20 22½ (572) WTHD-24 29 (737) WTHD-30 35 (889) WTHD-36 41 (1041) WTHD-42 47 (1194) WTHD-48 53¼ (1353) WTHD-54 59½ (1511) WTHD-60 65½ (1664) WTHD-72 781⁄8 (1984)
All dimensions are in inches (millimeters).
45° and 90° Weatherhood
(Square)
(267)
Figure 20: With Wall Collar
Recommended Wall Opening (W.O.)
Wall Housing or Wall Collar, see Figures 19 & 20
WTHD-8 14¼ WTHD-10 16¼ (413) WTHD-12 19¼ (489) WTHD-14 21¼ (540) WTHD-16 23¼ (591) WTHD-18 25¼ (641) WTHD-20 27¼ (692) WTHD-24 33¾ (857) WTHD-30 39¾ (1010) WTHD-36 45¾ (1162) WTHD-42 51¾ (1314) WTHD-48 57¾ (1467) WTHD-54 63¾ (1619) WTHD-60 69¾ (1772) WTHD-72 84¾ (2153)
All dimensions are in inches (millimeters).
(362)
MAINTENANCE
Disconnect and lockout power source before cleaning. Clean weatherhood of any accumulated dirt which would restrict airow.
4
Sidewall Propeller Fans • 45° and 90° Weatherhood Accessory
®
Damper Installation
BROWN
06/06/2008
1/1
BROWN
06/06/2008
1/1
To install an optional damper, refer to Figure 21. Using a pneumatic or electric drill, run the self­drilling screws through the holes provided in the side and bottom damper anges into the wall housing. Check damper for freedom of movement. If an optional damper guard or weatherhood is to be installed, refer to the next section.
Damper Installed Inside
Wall Housing Guard Installation
Attach wall housing guard to wall housing using the 1/4-20 x 3/4 thread cutting screw with washer. Refer to Figure 23.
Wall Housing
Weatherhood (Optional)
Damper
Damper Installed Outside
Wall Housing
Weatherhood (Optional)
Damper
Figure 21
Damper Guard or Weatherhood Installation
To install the damper guard, center guard over damper and fasten to wall housing using the self­drilling screws. Refer to Figure 22. To install the weatherhood, slide the top flange of weatherhood under the flange of wall housing, see Figure 21, and fasten with self-drilling screws.
Figure 23
Fit for Sidewall Propeller Fan Accessories
Figure 24 reveals the correct t for sidewall propeller fans after all optional accessories have been assembled and installed.
Damper Guard
Weatherhood
Figure 22
Wall Housing
Figure 24: Sidewall Propeller Fan Accessories
Sidewall Propeller Fans • 45° and 90° Weatherhood Accessory
5
®
Warranty
Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs.
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice.
Greenheck Sidewall Propeller Fans Catalog provides additional information describing the equipment, fan performance, available accessories, and specication data.
Phone: (715) 359-6171 • Fax: (715) 355-2399 • E-mail: gfcinfo@greenheck.com • Website: www.greenheck.com
6 472040 • Model 45° and 90° Weatherhood Accessory, Rev. 1, July 2008 Copyright 2008 © Greenheck Fan Corp
AMCA Publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans, provides additional safety information. This publication can be obtained from AMCA International, Inc. at: www.amca.org.
Loading...