TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting
means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including firerated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the
outdoors.
7. Do not use this fan with any solid-state speed
control device.
8. Acceptable for use over a tub or shower when
connected to a GFCI (Ground Fault Circuit
Interrupter) - protected branch circuit.
9. This unit must be grounded.
CAUTION
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
1. This product is designed for installation in ceilings
up to a 12/12 pitch (45 degree angle). Duct
connector must point up. DO NOT MOUNT THIS
PRODUCT IN A WALL.
2. To avoid motor bearing damage and noisy and/
or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
3. Please read specification label on product for
further information and requirements.
CAUTION
NOT FOR USE IN A COOKING AREA
Typical Installation
• Installation is the same for:
Joists I-Joists Trusses
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position between
joists from 14" to 24"
on center.
SP Ceiling Exhaust Fans
2
HOUSING
POWER
CABLE*
Seal gaps
around
Housing.
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
FAN
ROUND
DUCT*
Seal duct
joints with
tape.
OR
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
®
New Construction Installation
Tools needed
Power screwdriver with a Phillips bit
Phillips screwdriver
Flathead screwdriver
Pliers
Wire insulation stripper
Wire cutter
1 - Remove Packaging
Parts Bag holds
Knockout Plate
and six (6) screws
Remove
Instruction
Sheet
Materials needed
• 6" round metal ducting recommended for best
performance. Use of other ducting is acceptable but
may impact performance.
• Roof cap or wall cap (built-in damper recommended)
• Tape to seal duct connections
• Electrical wiring and supplies per local code
requirements
• 4W (max.) C7-type night light bulb
Remove CFL Bulbs
from protective packaging
Punch out Mask from
packaging. See Step 6.
2 - Install Mounting Frame
3
2
1
4
®
SP Ceiling Exhaust Fans
3
New Construction Installation
3 - Snap-in and Secure Housing
2
snap!
1
4
4 - Attach Duct Connector and Ducting
Top and bottom flanges
go outside Housing
Insert tab into slot
inside Housing
1
6" Ducting
Tape
Screws from Parts Bag
3
3
4" Ducting
Tape
Position Housing
between joists and
crimp channel
on both sides of
Mounting Frame
to lock Housing in
place. Do not crimp
Housing.
Screw from
Parts Bag
2
Tape
SP Ceiling Exhaust Fans
4
6" to 4" Reducer provided in select models
®
New Construction Installation
5 - Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation
location.
• Use proper UL-approved connectors to secure wiring
to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Attach cable clamps to
1
Knockout Plate. Knockout Plate
mounts to outside of Housing
and may be oriented as desired.
3
Fan
(2) 2-FUNCTION
CONTROLS
MODE
SELECT
SWITCH
MASTER
ON/OFF
SWITCH
FAN
BLK
WHTWHT
LINE
IN
GRDGRD
BLK
Light
LIGHT
NIGHT
LIGHT
Connect wires
2
BLKBLU
WHT
REDRED (Rated Level)
BLK
BLK*
(* Adjustable Level)
LIGHT
REDRED
NIGHT
LIGHT
FAN
WHT
WHT
WHT
UNITSWITCH BOX
4
Screw from
Parts Bag
BLACK
WHITE
BLUE
MODE
SELECT
MASTER
ON/OFF
SWITCH
FAN
(2) 2-FUNCTION CONTROLS
(purchase separately)
®
RED
GROUND
(green or bare)
SWITCH
LIGHT
NIGHT
LIGHT
BOX
120 VAC
LINE IN
LIGHT
RECEPTACLE
WIRES
KNOCKOUT
PLATE
FAN
RECEPTACLE
LIGHT
RECEPTACLE
FAN
RECEPTACLE
WIRES
SP Ceiling Exhaust Fans
5
New Construction Installation
6 - Insert Mask and Finish Ceiling
• Install ceiling material.
• Cut out around Housing.
7 - Install Grille
Mask protects unit
during construction.
Remove before
installing Grille.
8 - Install Bulbs
1
2
3
3
Night Light
(purchase separately)
SP Ceiling Exhaust Fans
6
1
2
4
NOTE: See Page 11 for Operations, Page 12 for
Cleaning and Maintenance, and Troubleshooting.
®
Retrofit Installation
Tools needed
Power screwdriver with a Phillips bit
Phillips screwdriverRuler
Flathead screwdriverPencil
PliersDrywall saw
Wire insulation stripperClaw hammer or pry bar
Wire cutterUtility knife
1 - Remove Packaging
Remove
Instruction
Sheet
Parts Bag holds
Knockout Plate
and six (6)
screws
2 - Switch Off Power
WARNING
Before removing existing fan, switch power off at
service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
Materials needed
• Tape to seal duct connections
• Existing rigid duct will require the addition of a short
length of flexible duct
• Electrical wiring and supplies per local code
requirements
• 4W (max.) C7-type night light bulb
Remove CFL Bulbs
from protective packaging
Punch out Mask from
packaging. See Step 12.
3 - Enlarge Ceiling Opening and Remove Existing Fan
12" (30.5 cm)
11" (27.9 cm)
parallel with joists
Existing ductwork and
1
wiring left in place
4 - Examine Wiring
Examine the existing wiring to make sure it is not
damaged. If any damage is found,
DO NOT CONTINUE INSTALLATION of this product.
Contact a qualified person(s) for repair.
2
®
SP Ceiling Exhaust Fans
7
Retrofit Installation
5 - Remove Blower Assembly
2
Both sides
6 - Remove Wiring Panel
1
Set aside
screw
1
Set aside
Blower Assembly
3
Set aside
Wiring Panel
2
3
7 - Insert Mounting Frame
4
3
1
Remove screws
from Mounting
Frame and set aside
5
2
Bend up
four tabs
SP Ceiling Exhaust Fans
8
®