Greenheck SP110L Installation Manual

Document 99045144B
Model SP110L/SP80L
®
Lighted Multi-Speed
Ceiling Exhaust Fan
Installation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble,
Please read and save these instructions for future reference. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by observing all safety
install, operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property damage!
information. Failure to comply with instructions could result in personal injury and/or property damage!
Model SP110L / SP80L
Service Parts
Key
Greenheck
No.
10 435117 Grille Assembly (includes 11, 12, 13) 11 435111 Grille Spring (2 req’d) 12 435118 Lens 13 435119 Bulb, GU24 18W 3500K FL (2 req’d)
Part No.
1 435100 Mounting Frame 2 435101 Knockout Plate & Screws 3 435102 Housing 4 435103 Wiring Panel/Harness Assembly
5
6 435106 Duct Connector - 6" 7 435114 6" to 4" Reducer (model SP80L only) 8 435108 Blower Wheel 9 435115 Scroll Assembly
434112 Control Assembly & Motor (SP80L) 435113 Control Assembly & Motor (SP110L)
Description
Easy installation in both new construction and retrofit.
1
2
3
4
5
6
7
8
9
11
12
13
10
Table of Contents
Warnings and Cautions ............................................ 2
Typical Installation .................................................... 2
New Construction Installation .................................. 3
Retrofit Installation ...................................................7
®
Operation ................................................................ 11
Cleaning and Maintenance ..................................... 12
Troubleshooting ...................................................... 12
Our Commitment .................................................... 12
SP Ceiling Exhaust Fans
1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire­rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this fan with any solid-state speed control device.
8. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
9. This unit must be grounded.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
1. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS
PRODUCT IN A WALL.
2. To avoid motor bearing damage and noisy and/ or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and requirements.
CAUTION
NOT FOR USE IN A COOKING AREA
Typical Installation
• Installation is the same for:
Joists I-Joists Trusses
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position between joists from 14" to 24" on center.
SP Ceiling Exhaust Fans
2
HOUSING
POWER CABLE*
Seal gaps
around
Housing.
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
FAN
ROUND
DUCT*
Seal duct
joints with
tape.
OR
ROUND
ELBOWS*
ROOF CAP* (with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
®
New Construction Installation
Tools needed
Power screwdriver with a Phillips bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter
1 - Remove Packaging
Parts Bag holds Knockout Plate and six (6) screws
Remove Instruction Sheet
Materials needed
• 6" round metal ducting recommended for best performance. Use of other ducting is acceptable but
may impact performance.
• Roof cap or wall cap (built-in damper recommended)
• Tape to seal duct connections
• Electrical wiring and supplies per local code requirements
• 4W (max.) C7-type night light bulb
Remove CFL Bulbs
from protective packaging
Punch out Mask from
packaging. See Step 6.
2 - Install Mounting Frame
3
2
1
4
®
SP Ceiling Exhaust Fans
3
New Construction Installation
3 - Snap-in and Secure Housing
2
snap!
1
4
4 - Attach Duct Connector and Ducting
Top and bottom flanges go outside Housing
Insert tab into slot inside Housing
1
6" Ducting
Tape
Screws from Parts Bag
3
3
4" Ducting
Tape
Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place. Do not crimp
Housing.
Screw from Parts Bag
2
Tape
SP Ceiling Exhaust Fans
4
6" to 4" Reducer provided in select models
®
New Construction Installation
5 - Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Attach cable clamps to
1
Knockout Plate. Knockout Plate mounts to outside of Housing and may be oriented as desired.
3
Fan
(2) 2-FUNCTION
CONTROLS
MODE SELECT SWITCH
MASTER
ON/OFF SWITCH
FAN
BLK
WHT WHT
LINE
IN
GRD GRD
BLK
Light
LIGHT
NIGHT LIGHT
Connect wires
2
BLK BLU
WHT
RED RED (Rated Level)
BLK
BLK*
(* Adjustable Level)
LIGHT
REDRED
NIGHT LIGHT
FAN
WHT
WHT
WHT
UNITSWITCH BOX
4
Screw from Parts Bag
BLACK WHITE BLUE
MODE
SELECT
MASTER
ON/OFF
SWITCH
FAN
(2) 2-FUNCTION CONTROLS
(purchase separately)
®
RED GROUND
(green or bare)
SWITCH
LIGHT
NIGHT LIGHT
BOX
120 VAC
LINE IN
LIGHT
RECEPTACLE
WIRES
KNOCKOUT
PLATE
FAN
RECEPTACLE
LIGHT
RECEPTACLE
FAN
RECEPTACLE
WIRES
SP Ceiling Exhaust Fans
5
New Construction Installation
6 - Insert Mask and Finish Ceiling
• Install ceiling material.
• Cut out around Housing.
7 - Install Grille
Mask protects unit during construction. Remove before installing Grille.
8 - Install Bulbs
1
2
3
3
Night Light
(purchase separately)
SP Ceiling Exhaust Fans
6
1
2
4
NOTE: See Page 11 for Operations, Page 12 for Cleaning and Maintenance, and Troubleshooting.
®
Retrofit Installation
Tools needed
Power screwdriver with a Phillips bit Phillips screwdriver Ruler Flathead screwdriver Pencil Pliers Drywall saw Wire insulation stripper Claw hammer or pry bar Wire cutter Utility knife
1 - Remove Packaging
Remove Instruction Sheet
Parts Bag holds Knockout Plate and six (6) screws
2 - Switch Off Power
WARNING
Before removing existing fan, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Materials needed
• Tape to seal duct connections
• Existing rigid duct will require the addition of a short length of flexible duct
• Electrical wiring and supplies per local code requirements
• 4W (max.) C7-type night light bulb
Remove CFL Bulbs
from protective packaging
Punch out Mask from
packaging. See Step 12.
3 - Enlarge Ceiling Opening and Remove Existing Fan
12" (30.5 cm)
11" (27.9 cm) parallel with joists
Existing ductwork and
1
wiring left in place
4 - Examine Wiring
Examine the existing wiring to make sure it is not damaged. If any damage is found,
DO NOT CONTINUE INSTALLATION of this product. Contact a qualified person(s) for repair.
2
®
SP Ceiling Exhaust Fans
7
Retrofit Installation
5 - Remove Blower Assembly
2
Both sides
6 - Remove Wiring Panel
1
Set aside screw
1
Set aside Blower Assembly
3
Set aside Wiring Panel
2
3
7 - Insert Mounting Frame
4
3
1
Remove screws from Mounting Frame and set aside
5
2
Bend up four tabs
SP Ceiling Exhaust Fans
8
®