Greenheck models SFD and SFB forward-curved
utility fans have been designed for supply, exhaust
and return air applications requiring low to medium
air volumes and pressures. You will receive the
following benefits with these fans:
• Performance ranges from 300 to 25,200 cfm
(510 to 42,815 m3/hr) with static pressures to 3.5in.
wg(872 Pa).
SFD fans are available in four sizes (6, 7½, 9 and
10) with different rpm motors. Capacities range
from 300 to 2700 cfm (510 to 4587 m3/hr) with
static pressures up to 2.5 in. wg (623 Pa).
SFB in ten sizes (9 through 30) with
capacities ranging from 360 to 25,200 cfm
(612 to 42815 m3/hr) and static pressures up
to 3.5 in. wg (872 Pa).
SWB
Belt Drive Utility Fans
• Greenheck utility
fans are designed,
engineered and tested
prior to shipment
to provide years of
smooth, vibration-free
operation with minimal
maintenance.
• Fan location mountings
are unlimited. The fan
may be mounted indoors
or outdoors.
• All fan sizes are tested in our AMCA Accredited
Laboratory, to ensure complete and accurate
performance ratings. All models are licensed to
bear the AMCA Air Performance seal. Performance
as cataloged is assured.
Greenheck’s backward-inclined utility fans have
many advantages; higher operating efficiencies,
non overloading horsepower curve and higher
pressure capability. You will also receive the
following benefits with these fans:
• AMCA Class 1 Performance on Series 200
(sizes210 through 236).
• Performance ranges from 70 to 30,000 cfm
(120to51,000 m3/hr) with static pressures up
to 5in.wg (1250 Pa).
SWB Series 100 in ten sizes (106 through 124)
with capacities from 100 to 11,000 cfm (170 to
19,689 m
(747 Pa).
3
/hr) and static pressures to 3.0 in. wg
SWB Series 200 in sixteen sizes (206 through
236) with capacities from 70 to 30,000 cfm
(120 to 50,970 m3/hr) and static pressures to
5.0 in. wg (1250 Pa).
• Two different series of construction will meet your
exact needs in the most efficient manner.
• Greenheck utility fans are designed, engineered
and tested prior to shipment to provide years of
smooth, vibration-free operation with minimal
maintenance.
• All fan sizes are tested in our AMCA Accredited
Laboratory, to ensure complete and accurate
performance ratings. All models are licensed to
bear the AMCA Air Performance seal. Performance
as cataloged is assured.
SFD, SFB Series 100 and SWB Series 200 models are
listed for electrical (UL/cUL 705) File no. E40001
SWB Series 200 models are listed for grease
removal (UL/cUL 762) File no. MH11745
SWB Series 200 models are listed for Emergency
Smoke Control Systems File No. MH17511
Greenheck Fan Corporation certifies that the model SFD,
SFB and SWB, fans shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA Publication
211 and comply with the requirements of the AMCA Certified
Ratings Program. The certified ratings for Model SFD, SFB
and SWB are shown on pages 13 to 49.
2
Table of Contents
Standard Construction Features ...........................4-5
Temperature Options ............................................... 6
Options and Accessories ...................................... 7-8
Engineering Data ...................................................... 9
Discharge Position and Dimensional Data ....... 10-11
The Quick Build (QB) program makes custom built-to-order products available
to ship in one, three, five, or ten days. This program offers greater flexibility—
your fan can be made-to-order and shipped in as little as one day. Five
configurations of SWB fans are in stock. Other SWB fan sizes are available in
five and ten day QB programs.
Other products are available from our Quick Delivery (QD) program. QD
provides same day shipment of Greenheck products from our strategically
located warehouses throughout the world.
Outstanding Customer Service
Greenheck’s experienced staff is ready to answer your questions
and delivers solutions. Our representatives have a wealth
of industry and product knowledge, they maintain the latest
information and can process orders directly to our factory.
Count on the personal service and expertise from our national and
international representative organizations. To locate the Greenheck representative
nearest you, call 715-359-6171 or visit our Web site at www.greenheck.com
Leading Edge Technical Support
When you need extensive product information, look no further. Greenheck
products are supported by the industry’s best product literature, ranging from
catalogs, installation, operation and maintenance manuals (IOM’s), electronic
media, computer aided product selection (CAPS) program and more. You’ll also
find this information on our Web site at www.greenheck.com
World Class Manufacturing
Greenheck’s skilled production workers use costeffective machines and unique dies designed and built by
our own engineers to add innovative features and greater
strength to our centrifugal utility exhaust fans. Our advanced
manufacturing processes and quality control procedures
always ensure the highest product quality. And just to be
sure you get the peace-of-mind you expect when you specify
Greenheck, our assembly inspectors test run and monitor
every fan before it leaves the factory. Results of these tests
are kept in permanent records for future reference.
3
Standard Construction Features
Wheel
1
SFD and SFB fans have forward-curved
centrifugal wheels constructed of die formed
steel with blades securely riveted to a steel
back plate and rim. Each wheel is statically and
dynamically balanced to precise tolerances.
SWB Series 100 and 200 through size 210 have
backward inclined non-overloading centrifugal
wheels constructed of aluminum. Series 200,
sizes 212 and larger are constructed of steel
or aluminum. Backward-inclined wheels are of
a heavy-gauge material with single-thickness
blades securely riveted or welded to a heavygauge backplate and wheel cone. Each wheel
is statically and dynamically balanced to
precise tolerances.
2
Finish - All structural steel parts are
phosphatized treated and coated with
Greenheck’s Permatector™ for a long lasting
finish. See housing and drive frame information
for specific material and coating.
3
Housing - SFD and SWB Series 100 housings
are constructed from galvanized steel. SFB
and SWB Series 200 fans are constructed of
steel and coated with Permatector™. Both
are available in clockwise or counterclockwise
rotation and are field rotatable to the eight
standard discharge positions. Housing sides
are bonded to the fan scroll with an airtight
lock seam. Full weld is available on SFB and
SWB Series 200 models.
Housing Supports - Housing supports are
4
constructed of structural steel with formed
flanges for extra strength.
5
Mounting Holes - Housing supports have
prepunched mounting holes which allow for
easy installation.
Drive Frame - Drive frames are constructed
6
of rugged, welded steel members supporting
the shaft and bearings to provide rigid
reinforcement for the housing. They are coated
with Permatector™. SFD drive frames are
constructed of galvanized steel, bolted and
available in arrangement 4—SFB and SWB are
arrangement 10.
Fasteners - Corrosion-resistant fasteners
7
are used to secure unit base and blower
scroll assembly.
Motor - Heavy-duty ball bearing motors are
8
carefully matched to the fan load. Open drip
proof, totally enclosed and explosion proof
enclosures are available.
9
Motor Plate - A pivoting motor plate with
adjusting screws make belt tensioning a quick
and easy operation. Excludes SFD.
Inlet Cone - Streamlined inlet cone design
10
provides for low turbulence air intake, reducing
intake losses and sound levels.
Belt Drive Only Features
Drive Assembly - Machined, cast iron pulleys
11
are factory set to the required RPM and are
adjustable for final system balancing. Sized for
a minimum of 150% of driven horsepower.
Fan Shaft - Precision turned, ground and
12
polished solid steel shafts are sized so the
first critical speed is at least 25% over the
maximum operating speed. Stainless steel
shafts are available on SWB Series 200 fans.
Bearings - Heavy-duty, self-aligning pillow
13
block ball bearings are selected for a minimum
L10 life in excess of 100,000 hours (L50 average
life of 500,000 hours) at maximum cataloged
operating conditions.
44
Standard Construction Features
2
7
8
SFD
3
9
5
1
13
11
9
12
13
8
6
5
3
4
SFB
3
2
11
7
2
13
9
12
8
6
5
4
3
11
1
10
4
5
13
6
8
SWB-200 SeriesSWB-100 Series
5
Temperature Options
Testing
High temperature testing was conducted at
Greenheck’s Research and Development
facility with airstream temperatures in
excess of 1000°F (538°C). Temperatures were
monitored at the following critical locations
throughout the tests: bearings, bearing
compartment, motor, motor compartment,
airstream, and fan housing.
Operating Temperatures
Utility set fans are suitable for applications
above normal operating temperatures of
70°F (21°C). Refer to the chart at the right
for operation temperature guidelines and
optional accessories.
High Temperature/Emergency Smoke Control
The SWB Series 200 sizes 212 and larger may
be equipped for emergency smoke removal
applications by specifying a high temperature
option. The table to the right indicates the
construction features included in the high
temperature options enabling exhaust of heat
and smoke at 500°F (260°C) for a minimum of
4 hours or 1000°F (538°C) for a minimum of
15 minutes.
High Temperature Option
•500°F(260°C) for a minimum of 4 hours
•1000°F(538°C) for a minimum of 15 minutes
Temperature ratings tested in accordance to
UL smoke control systems.
Emergency Smoke Control - UL Listed
•500°F(260°C) for a minimum of 4 hours
•1000°F(538°C) for a minimum of 15 minutes
Testing for Emergency Smoke Temperature and Time Guidelines
CodeClass
IRI500°F(260°C)4.00
SBCCI1000°F(538°C)0.25
BSIClass A150°C(302°F)5.00
Class B250°C(482°F)2.00
Class C300°C(572°F)0.50
Class D300°C(572°F)1.00
Class E400°C(752°F)2.00
Operating
Temperatures
and Construction
-20° to 200°F
(-29° to 93°C)
Standard
201° to 300°F
(94° to 149°C)
Heat Slinger/Shaft Seal
301° to 400°F
(149° to 204°C)
Heat Slinger/Shaft Seal
The maximum continuous operating temperature on the SWB is 400°F.
For continuous operating temperatures between 401° and 1000°F use an
Arrangement 1, 9 or 10, backward-inclined centrifugal fan model BISW.
High Temperature SWB Features
Steel Construction
Shaft Seal
Heat Slinger
Weatherhood
UL Label (Power ventilators for smoke
control systems)
Series 100
Galvanized
Tested
Temperature
SWB
Painted
Converted
Temperature
SWB
Series 200
Steel
Aluminum
Airstream
High
Temperature
Option
Time
(Hours)
SFD, SFB
SFDSFB
High
Temperature
Option with UL
Spark-Resistant Construction Options
The following AMCA Standards apply to fan
applications that may involve the handling of
potentially explosive or flammable particles, fumes
or vapors.
•AMCA Type A - All parts in contact with the
airstream are constructed of nonferrous material
(aluminum). Model SWB does not meet AMCA
Type A Spark Resistant Construction because the
shaft is steel.
•AMCA Type B - The fan wheel is constructed
of nonferrous material (aluminum). A nonferrous
(aluminum) rub ring surrounds the fan shaft where
6
6
it passes through the fan housing. Available on all
SWB sizes with an aluminum wheel and rub ring.
•AMCA Type C - The inlet cone is constructed
of nonferrous material (aluminum). A nonferrous
(aluminum) rub ring surrounds the fan shaft where
it passes through the fan housing.
The constructions listed minimize the potential
of ferrous components making contact with each
other that may produce sparks. However, they do
not guarantee against the potential of producing
sparks. The installer must electrically ground all fan
and system components.
Options and Accessories
UL/cUL 762- SWB Series 200
models are listed for grease
removal (UL/cUL 762). The UL/cUL
762 option includes a weatherhood,
threaded drain connection and
bolted access door. Indoor
mounting requires the fan to have
welded scroll construction.
Weatherhood - Available to completely cover the
motor and drive compartments; protecting the shaft,
bearings, motor, and drive components from moisture
and other adverse weather conditions. Weatherhoods
are vented to provide sufficient motor cooling.
Drain Connection - Threaded drain connections can
be provided to drain moisture from the bottom of the
fan housing.
Grease Trap (SWB Only) - Aluminum trap is designed
to collect grease residue and avoid drainage onto roof
surface. Disposable grease absorbents are available for
easy maintenance.
Access Doors - Access doors provide access for
inspection & cleaning. Both bolted or hinged, quick
opening access doors are available on all models
except SFD.
Welded Scroll Construction - Welded scroll
construction is available on SWB Series 200.
Aluminum Construction- Aluminum airstream option
is available on SWB Series 200.
Dampers - Gravity or motorized
parallel blade backdraft dampers
feature sturdy galvanized frames
with prepunched mounting holes,
aluminum blades with felt edges
and balanced design for minimal
resistance to airflow. Backdraft
dampers are not suitable for
downblast or bottom angular downblast discharge
positions. The fan must be supplied with a flanged
outlet to install a backdraft damper directly to the fan.
Heavy-duty dampers are available for high pressure
applications on fans with motors equal to or greater
1
than 7
⁄2 horsepower.
Disconnect Switches - A wide selection
of NEMA rated switches are available
for positive electrical shutoff and safety,
including: dust-tight, rainproof and
corrosion-resistant.
Wiring Pigtail - Allows direct hookup to the power
supply eliminating field wiring to the fan.
Extended Lube Lines - Lubrication lines with grease
fittings are extended from shaft bearings to the base of
the drive frame panel for easy bearing lubrication.
Inlet and Outlet Guards - Constructed of
expanded metal mounted in a steel frame
to provide protection for non-ducted
installations. The guards can be easily
removed for maintenance or inspection.
Flanged Inlet and Outlet - Flanges are welded to the
fan and are available for damper mounting or flanged
duct connections. Inlet flanges have prepunched
mounting holes.
Companion Flange - Connects to the inlet or
outlet flange and then attaches to the ductwork.
Recommended for slip-fit duct connections.
dampers are available on model SWB fans, sizes
112–124 and 212–236. External vanes
are mounted on the inlet flange. Inlet
vane dampers feature zinc-plated steel
blade axles, stainless steel washers and
bearings. Vanes can be used for either
manual or automatic operation, with
controls furnished by others. Maximum
operating temperature is 200°F
Coatings -
available for decorative to acidic applications on SFB
and SWB Series 200. All Greenheck coatings can be
found in the Performance Coatings for Commercial and
Industrial Fans publication.
A wide variety of coatings and colors are
Permatector™ is our standard coating. Typically
used for applications that require corrosion
resistance in indoor and outdoor environments.
Hi-Pro™ Polyester is resistant to salt water,
chemical fumes and moisture in more corrosive
atmospheres. Typically used for applications
requiring superior chemical resistance, excellent
abrasion and outdoor UV protection. This coating
exceeds protective qualities of Air Dried Heresite
and Air Dry Phenolic.
Baked Enamel Decorative Coatings are heat cured
enamels applied either as wet paints or electrostatic
powders. Customers can choose from 16 standard
decorative colors or color match any color.
(93°C).
Heat Slinger and Shaft Seal (all belt models) - Heat
Slinger is an aluminum cooling disc mounted on
the fan shaft between the inboard bearing
and the fan housing. The disc dissipates
heat conducted along the fan shaft.
The shaft seal with an aluminum rub
ring is available for applications where
contaminated or high temperature air
is being handled.
BELT GUARDS - Sturdy three-sided
fabricated steel belt guards provide
protection from rotating pulleys and belts.
The belt guards meet OSHA requirements.
7
Mounting Options
Vibration Isolators
Base-mounted neoprene or spring isolators are available to lessen mechanical vibration and assure quiet
operation. Free-standing, restrained and housed spring isolators are also available. Isolators are sized to
match the weight of each fan.
Free-Standing Open
Spring Mounts -
Type 3, 1-inch Deflection
Free-standing spring
isolators are unhoused
laterally stable steel springs.
They provide a minimum
horizontal stiffness of 0.8
times the rated vertical stiffness and provide an
additional 50% overload capacity. These isolators
are equipped with a top-mounted adjusting bolt
and an acoustical non-skid base. Springs are color
coded or identified to indicate load capacity.
Housed Spring Mounts
Type 4B, 1-inch Deflection
Housed spring isolators
consist of steel springs
assembled into a telescoping
housing with a top-mounted
adjusting bolt and an
acoustical non-skid base.
Housed spring isolators
include resilient inserts to prevent metal-to-metal
contact and provide snubbing for side loads.
Springs provide an additional 50% overload
capacity and are color coded or identified
to indicate load capacity.
Rubber Mounts -
Type 2, 1⁄4-inch and
1
⁄2-inch Deflection
Neoprene mountings
consist of a steel top plate
and base plate completely
embedded in colored (oilresistant) neoprene for easy
identification of capacity. Neoprene mountings are
furnished with a tapped hole in the center. This
enables the equipment to be bolted securely to the
rubber mount.
Restrained Spring
Mounts -
Type 4A, 1-inch Deflection
Restrained spring isolators
consist of laterally stable,
free-standing springs
assembled into a steel
housing. These assemblies
are designed for vertical and horizontal motion
restraint. Restrained spring isolators can be used
for blocking during equipment installation and are
provided with leveling bolts. Springs provide 50%
overload capacity and are color coded or identified
to indicate load capacity. Restrained spring mounts
are recommended for equipment subject to wind
loading or large torquing forces.
Direct Mount - Type A
No base required. Isolators
are attached directly to
equipment. Direct isolation
can be used if equipment
is unitary and rigid without
the use of additional
support. Direct isolation
is not recommended for
equipment having large
overhung loads (e.g. motors on
Arr. 9 fans). If there is any doubt
whether or not equipment can be
supported directly on isolators, use
rails, bases or consult the factory.
Mounting Rails
with Isolators
Isolation mounting rails are
available with ¼-inch of
deflection and either rubber
mount, free-standing open
or restrained spring isolators.
The isolators are mounted
between aluminum rails
that run the length of the fan
base. Isolation rails provide easy
installation on isolated systems,
and are ideal for applications where
there is a large overhung load.
Equipment Supports
Models GESS and GESR equipment supports are available for roof
mounting of all utility fans. Equipment supports are available in a number
of lengths, widths, heights, and can also be built for a pitched roof.
8
Engineering Data
Selection
The first consideration in any fan
selection is the amount of air to be
moved and the resistance to this air
movement. Air volume requirements are
established through specific codes or
accepted industry standards. Once the
air volume is known, system resistance
can be determined by summing up the
losses through the system components.
Duct layout, duct size, coils, filters,
dampers, and fan accessories all affect
system resistance. ASHRAE Guide and
Data Books and manufacturer’s data
on individual system components are
common sources of information available
to the system designer.
In most applications, several fans may
meet the required airflow and system
resistance conditions. An optimum
fan selection requires evaluation of
alternative fan types and fan sizes, as
they relate to initial cost, operating cost,
available space, and allowable sound
levels. The relative importance of these
facts varies with each system.
TWO TYPES OF FANS ARE AVAILABLE:
Effects of Installation on Performance
Fan ratings presented in the performance tables and curves
of this catalog are in accordance with AMCA Standard 210
“Laboratory Methods of Testing Fans for Aerodynamic
Performance Rating.” The AMCA test procedure utilizes an
open inlet and a straight outlet duct to assure maximum static
regain.
Any installation with inlet or discharge configurations
that deviate from this standard may result in reduced fan
performance. Restricted or unstable flow at the fan inlet can
cause prerotation of incoming air or uneven loading of the fan
wheel yielding large system losses and increased sound levels.
Free discharge or turbulent flow in the discharge ductwork will
also result in system effect losses.
The examples below show system layouts and inlet and
discharge configurations which can affect fan performance.
GOODPOOR
POOR
GOOD
POOR
GOOD
1. Backward-inclined utility fans—turn
at twice the speed of forward-curved
fans and feature:
• Higher operating efficiencies
• A non overloading horsepower
curve, which reaches a maximum in
the middle of the normal operation
range
• Stronger wheel design allowing for
operation at higher static pressures
2. Forward-curved fans—typically
have lower performance capabilities
compared to the backward incline
and contain:
• Overloading type wheel (wheel
meaning that changes in
performance can result in significant
brake horsepower changes)
• Forward-curved wheels with lower
sound levels
Comprehensive air performance data for
these utility fans can be found in the fan
tables and fan curves section, starting on
page 13.
7o MAX.
POOR
GOODPOORPOOR
Not Greater than
60o Including Angle
GOOD
GOOD
One Fan Dia.
GOOD
GOOD
Should be at least
1/2 Dia. Impeller
POOR
9
Page HeaderSWB Discharge Position
and Dimensional Data
D
H
J
H
B
H
I
H
E
H
F
H
C
H
G
H
A
CW BAU
B
C
CW UB
I
CW TAU
E
A
CW TH
F
CW TAD
C
CW DB
G
I
CW BAD
D
E
A
CW BH
J
F
CCW BAU
C
B
SWB
D
A
H
Size
106
107
CCW UB
G
D
G
I
CCW TAU
E
D
A
108
J
H
110
113
115
B
116
118
H
120
CCW TH
J
B
F
J
CCW TAD
C
B
124
I
H
206
207
208
210
E
A
H
212
213
CCW DB
I
G
CCW BAD
E
D
F
H
215
216
218
220
222
C
224
H
227
A
CCW BH
F
J
230
233
G
236
H
ABCDEFGHIJ
15
1
(49)
15
1
(49)
15
1
(49)
15
1
(49)
11
2
(68)
1
3
(79)
1
3
(89)
1
4
⁄16
(103)
9
4
⁄16
(116)
13
5
(402)
15
1
(49)
15
1
(49)
15
1
(49)
15
1
(49)
5
2
⁄16
(59)
11
2
(68)
1
3
(79)
1
3
(89)
1
4
⁄16
(103)
9
4
⁄16
(116)
3
5
⁄16
(132)
13
5
(402)
5
(127)
5
6
(168)
⁄16
⁄16
⁄16
⁄16
⁄16
⁄8
⁄2
⁄16
⁄16
⁄16
⁄16
⁄16
⁄16
⁄8
⁄2
⁄16
⁄8
1
⁄8
14
(359)
141⁄8
(359)9¼(235)
141⁄8
(359)
1
⁄8
14
(359)
5
⁄8
17
(448)
191⁄2
(495)
1
⁄4
21
(540)
233⁄8
(594)
251⁄2
(648)
3015⁄16
(786)
141⁄8
(359)
141⁄8
(359)
1
⁄8
14
(359)
141⁄8
(359)
161⁄8
(410)
175⁄8
(448)
191⁄2
(495)
211⁄4
(540)
233⁄8
(594)
251⁄2
(648)
281⁄16
(713)
3015⁄16
(786)
1
28
⁄16
(713)
381⁄8
(968)25(635)
7¼
(184)42(1067)27(686)23(584)
8
(203)
3
46
(1178)
⁄8
SWB Dimensions
1
13
⁄4
⁄4
3
⁄4
⁄15
⁄4
⁄16
7
(198)
713⁄16
(198)
713⁄16
(198)
7
(198)
(251)
10
(273)
103⁄4
(273)
103⁄4
(273)
13
⁄16
10
(273)
7
⁄8
9
13
(346)
151⁄8
(384)
16
(406)
131⁄4
185⁄16
(337)
(368)
(451)
713⁄16
(198)
713⁄16
(198)
7
(198)
713⁄16
(198)
141⁄2
173⁄4
13
(465)
201⁄16
(510)
247⁄16
(621)
103⁄4
(273)
103⁄4
(273)
⁄16
10
(273)
103⁄4
(273)
123⁄8
(314)
97⁄8
(251)
135⁄8
(346)
151⁄8
(384)
169⁄16
(406)
131⁄4
185⁄16
(337)
(368)
141⁄2
(465)
201⁄16
(510)
221⁄8
(562)
173⁄4
247⁄16
(451)
(621)
221⁄8
(562)
211⁄8
(537)29(737)
32
(822)
255⁄8
(651)35(889)
9
(235)
91⁄4
(235)
1
9
(235)
11
(298)
131⁄16
(332)11(279)
5
14
(364)12(305)
1513⁄16
(402)
171⁄4
(438)
211⁄16
(535)
91⁄4
(235)
91⁄4
(235)
1
9
(235)
91⁄4
(235)
1011⁄16
(271)9(229)
113⁄4
(298)
131⁄16
(332)11(279)
145⁄15
(364)12(305)
1513⁄16
(402)
171⁄4
(438)
191⁄16
(484)16(406)
211⁄16
(535)
191⁄16
(484)16(406)
303⁄4
(781)
3
1
⁄4
10
(257)
101⁄8
(257)
101⁄8
(257)
3
⁄4
10
(257)
5
⁄8
12
(324)
141⁄8
(359)
9
⁄16
15
(394)
171⁄8
(435)
183⁄4
(476)
227⁄8
(581)
101⁄8
(257)
101⁄8
(257)
3
⁄4
10
(257)
101⁄8
(257)
115⁄8
(295)
123⁄4
(324)
141⁄8
(359)
151⁄2
(394)
171⁄8
(435)
183⁄4
(476)
205⁄8
(524)
227⁄8
(581)
205⁄8
(524)
271⁄4
(692)
3
⁄8
301⁄4
(768)
327⁄8
(835)
5
⁄8
⁄8
8
(219)
85⁄8
(219)
85⁄8
(219)
1
5
⁄8
⁄8
8
(219)
3
7
⁄4
10
(276)
121⁄8
(308)
1
1
⁄2
13
(337)
145⁄8
(371)
161⁄8
(410)
199⁄16
(497)
85⁄8
(219)
85⁄8
(219)
1
5
⁄8
⁄8
8
(219)
85⁄8
(219)
915⁄16
(252)
107⁄8
(276)
121⁄8
(308)
13¼
(337)
145⁄8
(371)
161⁄8
(410)
1711⁄16
(449)
199⁄16
(497)
1711⁄16
(449)
231⁄4
(591)
2513⁄16
(656)
281⁄16
(713)
1
⁄8
15
(384)
151⁄8
(384)
151⁄8
(384)
15
(384)
⁄8
16
(422)
181⁄2
(470)
⁄4
20
(518)
223⁄8
(568)
241⁄2
(622)
311⁄2
(800)
151⁄8
(384)
151⁄8
(384)
15
(384)
151⁄8
(384)
151⁄8
(384)
165⁄8
(422)
181⁄2
(470)
203⁄8
(518)
223⁄8
(568)
241⁄2
(622)
283⁄4
(730)
311⁄2
(800)
283⁄4
(730)
365⁄8
(930)
11
(292)
111⁄2
(292)
111⁄2
(292)
1
⁄8
11
(292)
5
⁄8
14
(371)
161⁄4
(413)
3
⁄8
17
(451)
195⁄8
(498)
211⁄2
(546)
261⁄4
(667)
111⁄2
(292)
111⁄2
(292)
1
⁄8
11
(292)
111⁄2
(292)
131⁄4
(337)
145⁄8
(371)
161⁄4
(413)
173⁄4
(451)
195⁄8
(498)
211⁄2
(546)
233⁄4
(603)
261⁄4
(667)
233⁄4
(603)
313⁄8
(797)
401⁄4
(1022)35(889)25(635)
441⁄2
(1130)
385⁄8
(981)
1
5
⁄2
⁄8
8
(219)
85⁄8
(219)
85⁄8
(219)
1
5
⁄2
⁄8
8
(219)
5
5
⁄8
10
⁄8
(270)
115⁄8
(295)
3
1
⁄4
12
⁄2
(318)
133⁄4
(349)
147⁄8
(378)
173⁄4
(451)
85⁄8
(219)
85⁄8
(219)
1
5
⁄2
⁄8
8
(219)
85⁄8
(219)
93⁄4
(248)
105⁄8
(270)
115⁄8
(295)
121⁄2
(318)
133⁄4
(349)
147⁄8
(378)
161⁄4
(413)
173⁄4
(451)
161⁄4
(413)
211⁄2
(546)
271⁄4
(692)
All dimensions in inches (millimeters).
10
SFD and SFB Discharge
Page Header
Positions and Dimensional Data
C
B
D
A
H
E
D
A
B
H
I
H
J
H
GJ
IF
Unit SizeABCDEFGHIJ
1
⁄16
87⁄16
SFD-6
SFD-7.5
SFD-9
SFD-10
1
1
1
(27)
1
(32)
5
(33)
15
(49)
(214)
1
⁄4
101⁄4
(260)
⁄16
1113⁄16
(300)
⁄16
14
(356)
SFD Dimensions
59⁄16
(141)
613⁄16
(173)
(197)
91⁄4
(235)
73⁄4
43⁄4
(121)
513⁄16
(148)
61⁄2
(165)
713⁄16
(198)
61⁄2
(165)
73⁄4
(197)
815⁄16
(227)
103⁄4
(273)
SFB Dimensions
61⁄16
(154)
71⁄4
(184)
85⁄16
(211)
101⁄16
(256)
53⁄16
(132)9 (230)
61⁄4
81⁄2
92⁄3
(245)
107⁄9
(274)
123⁄4
(324)
(159)
73⁄16
(183)
(216)
51⁄4
(133)7 (178)
63⁄4
(171)
71⁄2
(191)
81⁄2
(216)
81⁄2
(216)
91⁄2
(241)
111⁄2
(292)
Unit SizeABCDEFGHIJ
3
⁄8
1211⁄16
C
B
E
H
F
A
H
JG
SFB-10
SFB-12
SFB-15
SFB-9
ED
C
H
A
G
H
FI
SFB-18
SFB-20
SFB-22
SFB-25
SFB-27
SFB-30
1
(35)
7
1
(37)
1
2
(57)
11
2
(68)
1
4
(103)
9
4
(116)
5
5
(135)
1
6
(154)
5
(127)
5
6
(168)
⁄16
⁄16
⁄16
⁄16
⁄16
⁄4
⁄16
⁄8
(322)
141⁄2
(368)
(406)
179⁄16
(446)
233⁄8
(594)
251⁄2
(648)
(711)
3011⁄16
(779)
(864)
381⁄8
(968)
16
28
34
81⁄4
(210)7 (178)
95⁄16
22
25
713⁄16
(198)
91⁄16
(230)
915⁄16
(252)
131⁄4
(337)
141⁄2
(368)
16
(406)
173⁄4
(451)
19
(483)
211⁄8
(537)
(237)
1011⁄16
(271)
1113⁄16
(300)
1513⁄16
(402)
171⁄4
(438)
191⁄16
(484)
211⁄16
(535)
(559)
(635)
91⁄2
(241)
103⁄4
(273)
123⁄8
(314)
1311⁄16
(348)
185⁄16
(465)
201⁄16
(510)
221⁄8
(562)
247⁄16
(621)
261⁄2
(673)
29
(737)
815⁄16
(227)
101⁄16
(256)
119⁄16
(294)
1211⁄16
(322)
171⁄8
(435)
183⁄4
(476)
203⁄4
(527)
227⁄8
(581)
241⁄2
(622)
271⁄4
(692)
75⁄8
(194)
89⁄16
(217)
97⁄8
(251)
107⁄8
(276)
145⁄8
(371)
161⁄16
(408)
1711⁄16
(449)
199⁄16
(497)
207⁄8
(530)
231⁄4
(591)
134⁄5
(350)8 (203)
151⁄6
(385)
151⁄6
(385)
163⁄4
(426)
221⁄3
(567)
244⁄9
(621)
284⁄9
(723)
313⁄5
(803)
(838)
363⁄5
(930)
33
91⁄4
(235)
93⁄4
(248)
105⁄8
(270)
133⁄4
(349)
147⁄8
(378)
16
(406)
171⁄2
(445)
187⁄8
(479)
21
(533)
101⁄4
(260)
111⁄2
(292)
131⁄4
(337)
145⁄8
(371)
195⁄8
(498)
211⁄2
(546)
233⁄4
(603)
261⁄4
(667)
283⁄4
(730)
315⁄8
(803)
All dimensions in inches (millimeters).
Model Number Code
The model number code is designed to completely identify the fan. The correct code letters must be specified to
designate the correct construction. The remainder of the model number is determined by the size and performance.
SW B - 1 10 - 3 - CW - TH
Wheel Type
SW - Backward-Incline
SF - Forward-Curved
Series (SWB Only)
100 - Galvanized Construction
200 - PermatectorTM Coated
UB - Upblast
TAU - Top Angular Upblast
TH - Top Horizontal
TAD - Top Angular Downblast
DB - Downblast
BAD - Backward Angular Downblast
BH - Backward Horizontal
BAU - Backward Angular Upblast
11
11
SWB Typical Installations
3 Wheel
Diameters
SFD, SFB and SWB
General Clean Air or Fume Hood (Non–Grease)
The SFD, SFB and
SWB are designed for
applications ranging from
clean air to contaminated
air. Typical installations are
shown below. Installations
must include a means for
Flex
inspecting, cleaning and
servicing the exhaust fan.
SWB
Model SWB Series 100 and 200 are designed for supply, exhaust and return air applications. Tests
were conducted to assure safe, rugged and reliable fans capable of withstanding severe conditions.
Due to the varying airstreams encountered in commercial ventilation, system designers must be
aware of national, state and local codes and guidelines governing these installations.
Flex
3 Wheel
Diameters
SWB, Commercial Kitchen (Grease)
Greenheck’s SWB Series 200 are designed to meet restaurant and foodservice applications. These fans
are UL and cUL Listed for grease removal and have been tested under elevated temperature conditions.
Due to high temperatures and grease-laden airstreams in commercial kitchen ventilation, system designers
must be aware of governing codes and guidelines. The National Fire Protection Association (NFPA) is
the primary source used by many local codes for commercial kitchen ventilation systems. Local code
authorities should be consulted before proceeding with any kitchen ventilation project.
Installation must include a means for inspecting, cleaning and servicing the exhaust fan.
Fans selected for grease removal must include a weatherhood, bolted access door and 1-inch (25 mm)
drain connection. For grease applications where the fan is mounted indoors, the welded scroll option
must be selected. An outlet guard is strongly recommended when the fan discharge is accessible. When
an outlet guard is not ordered with the fan, it must be provided by the installer. An upblast discharge is
recommended. No dampers are to be used in the system.
The fan discharge must be a minimum of 40 inches (1016 mm) above the roof line and the exhaust
duct must be fully welded to a minimum distance of 18 inches (457 mm) above the roof surface.
Upblast Discharge
Optional
Companion
Flange
SWB Series 200 models are
listed for grease removal
(UL/cUL 762).
File no. MH11745
12
**40 in.
(1016 mm)
Per NFPA 96 the fan discharge must be
**
a minumum distance of 40 in. (1016 mm)
above the roof surface.
Weatherhood
3 Wheel
Diameters
Duct
From
Kitchen
Hood
*18 in.
(457 mm)
Per NFPA 96 the duct must
*
be all welded construction
to a minumum distance of
18 in. (457 mm) above the
roof surface.
Page Header
SFD Direct Drive
N
P
B
A
C
EE
M
J
H
D
H
G
F
K
L
DIMENSIONAL DATA
Model
SFD
7.5
10
ABCDEFGHJKLMNP
3
⁄8
51⁄4
16
11
5/8
7
6
(187)
(133)
(406)
(279)
51⁄4
181⁄16
9
(229)
(133)
1
⁄8
10
9
(257)
12
(308)
61⁄4
(159)
1
⁄8
63⁄4
(171)
(459)
205⁄16
(516)
245⁄16
(618)
121⁄4
(311)
133⁄4
(349)
161⁄4
(413)
(16)
5/8
(16)
5/8
(16)
9/16
(14)
1411⁄16
(373)
145⁄16
(364)
177⁄8
(454)
193⁄8
(492)
83⁄16
(208)
81⁄8
(206)
103⁄8
(264)
113⁄8
(289)
11⁄16
(27)
11⁄16
(27)
11⁄16
(27)
11⁄16
(27)
91⁄16
(230)6 (152)
95⁄8
(244)8 (203
103⁄4
(273)
123⁄4
(324)
10
(254)
12
(305)
11⁄4
(32)
11⁄4
(32)
11⁄4
(32)
11⁄4
(32)
7/8
(22)
11⁄8
(29)
13⁄8
(35)
13⁄8
(35)
111⁄4
(286)
1311⁄16
(348)
1513⁄16
(402)
185⁄8
(473)
All dimensions in inches (millimeters) and weight in pounds (kilograms). *Approximate unit weight with largest frame size motor (60 Hz).
Model
Number
Motor HPFan
RPM
0.1250.250.3750.50.7511.251.522.5
Static Pressure in Inches wg
CFM407338232
SFD-6-6B1/61140
BHP0.060.050.03
Sones6.76.04.7
CFM667628585541424
SFD-6-4A1/41725
BHP0.240.220.200.170.13
Sones13.612.812.311.710.5
CFM672612549467
SFD-7.5-6B1/61140
BHP0.160.140.130.10
Sones10.69.89.48.6
CFM10621028988949869775636
SFD-7.5-5A1/21725
BHP0.590.560.530.500.460.380.30
Sones2018.616.815.814.112.711.3
CFM839748645487
SFD-9-4C1/4860
BHP0.180.150.120.09
Sones9.27.87.06.6
CFM115910971028957782
SFD-9-5B1/21140
BHP0.460.420.380.340.26
Sones16.114.914.313.612.3
CFM18061765172516831595150214071298989
SFD-9-15A11⁄21725
BHP1.641.591.541.481.361.241.131.010.70
Sones312928272522212119.3
CFM125911761085965
SFD-10-3C1/3860
BHP0.360.320.290.25
Sones12.311.310.09.2
CFM171316531592152813781163
SFD-10-7B3/41140
BHP0.860.820.770.720.640.52
Sones19.418.517.617.015.713.9
CFM2641260325642525244423622275217919421621
SFD-10-30A31725
BHP3.032.982.932.872.732.602.442.322.011.62
Sones39373635333130292725
Performance certified is for installation Type B - Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).
53⁄16
(132)
63⁄8
(162)
77⁄16
(189)
81⁄2
(216)
Max. Motor
Frame Size
56
56
145T
184T
Weight
*Unit
30
(14)
40
(18)
75
(34)
113
(51)
13
SFB-9 - Belt Drive
167⁄8
(429)
8
(203)
101⁄4
(260)
101⁄8
(257)
24
(610)
133⁄4
(349)
15⁄8
(41)
197⁄8
(505)
131⁄2 (343)
141⁄4(362)
Wheel Diameter = 91⁄2(241)
Shaft Diameter = 3/4 (19)
Outlet Area = 0.454 ft
2
(.042m2)
^Approximate Unit Weight = 120 lb. (54 kg)
All dimensions in inches (millimeters)
For additional discharge positions see page 11
^Weight shown is largest cataloged Open Drip Proof motor
151⁄2
(394)
115⁄16
(287)
20 (508)
65⁄8
(168)
(51)
10
(254)
2
e
v
r
u
c
m
e
t
s
y
s
s
i
h
t
f
o
t
f
e
l
e
h
t
o
t
t
c
e
l
e
s
t
o
n
o
D
Maximum BHP at given RPM = (RPM/1747)
3
Maximum RPM = 2000 and Minimum RPM = 450
Tip Speed (ft/min.) = 2.49 x RPM
Maximum Motor Frame Size = 145T
Model
Number
CFMOV
0.250.50.7511.251.51.7522.252.5
Static Pressure in Inches wg
RPM644
360792
BHP0.03
Sones6.3
RPM681891
4601013
BHP0.050.08
Sones6.811.0
RPM72893010901225
5601233
BHP0.070.110.150.19
Sones7.510.810.110.3
RPM780966112912641382
6601453
BHP0.090.140.180.230.28
Sones8.510.710.310.611.0
RPM838101311661303142215281628
7601674
BHP0.130.180.230.280.340.390.44
Sones9.810.610.711.011.813.214.5
RPM90910641207134014611568166717581845
SFB-9
8601894
BHP0.170.230.280.340.400.460.520.580.64
Sones11.110.911.111.412.614.015.417.018.6
RPM983111812561378149816081706179818831965
9602114
BHP0.230.280.340.400.470.540.610.680.750.82
Sones11.111.511.812.113.414.916.418.019.721
RPM105911741306142615341644174518371923
10602334
BHP0.300.350.420.490.550.630.710.780.86
Sones12.012.212.613.214.315.817.519.121
RPM121613181417152816311728181819111999
12602775
BHP0.480.540.610.690.770.840.921.011.10
Sones14.214.314.615.716.818.119.52123
RPM12971392148215831682177718661949
13602995
BHP0.590.660.720.810.890.981.061.14
Sones15.715.716.117.018.119.52122
RPM13781468155416391736182719151998
14603215
BHP0.710.790.860.941.031.131.2213.31
Sones17.317.217.618.319.6212224
Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (bhp) does not include transmission losses. Performance ratings do not include the
effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only.
14
Page Header
SFB-10 - Belt Drive
193⁄8
265⁄8
(676)
111⁄2
(292)
151⁄8
(384)
(492)
16 (406)
167⁄8(429)
91⁄4
(235)
113⁄4
(298)
21⁄4
(57)
221⁄4
(565)
151⁄2
(394)
12
(305)
203⁄8(518)
22 (559)
Wheel Diameter = 105⁄8(270)
Shaft Diameter = 3/4 (19)
Outlet Area = 0.705 ft
2
(.065m2)
^Approximate Unit Weight = 130 lb. (59 kg)
All dimensions in inches (millimeters)
For additional discharge positions see page 11
^Weight shown is largest cataloged Open Drip Proof motor
81⁄2
(216)
(51)
11
(279)
2
e
v
r
u
c
m
e
t
s
y
s
s
i
h
t
f
o
t
f
e
l
e
h
t
o
t
t
c
e
l
e
s
t
o
n
o
D
Maximum BHP at given RPM = (RPM/1310)
3
Maximum RPM = 1650 and Minimum RPM = 400
Tip Speed (ft/min.) = 2.78 x RPM
Maximum Motor Frame Size = 145T
Model
Number
CFMOV
0.250.50.7511.251.51.7522.252.5
Static Pressure in Inches wg
RPM526
600851
BHP0.05
Sones5.6
RPM575730
7901121
BHP0.080.12
Sones6.29.1
RPM6337778971013
9801390
BHP0.130.180.230.30
Sones7.110.310.310.2
RPM69382894410451144
11701660
BHP0.190.250.320.380.45
Sones8.310.710.310.610.9
RPM76088799410921181126313491430
13601930
BHP0.270.350.420.500.570.640.730.81
Sones9.910.710.711.011.312.013.314.7
RPM82894610491142122913091383145615311603
SFB-10
15502199
BHP0.370.460.540.630.730.810.890.971.021.17
Sones11.111.011.311.612.013.014.215.517.018.7
RPM898100911091196127913571430149915641629
17402469
BHP0.500.600.700.790.891.001.091.181.271.37
Sones11.411.712.112.413.114.215.516.818.119.9
RPM97310771169125613321407147915461611
19302739
BHP0.660.770.870.991.081.201.321.431.53
Sones12.412.713.013.614.515.616.818.119.8
RPM10501145123213161393146115291596
21203008
BHP0.850.971.091.211.331.431.561.69
Sones13.813.914.115.016.017.118.319.8
RPM11281214129913761452152215851647
23103278
BHP1.081.211.341.461.591.721.841.97
Sones15.315.215.616.517.618.82022
RPM1207128513681441151215811645
25003548
BHP1.361.481.631.761.902.042.18
Sones17.116.917.418.319.42122
Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (bhp) does not include transmission losses. Performance ratings do not include the
effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only.
15
SFB-12 - Belt Drive
213⁄8
283⁄8
(721)
131⁄4
(337)
151⁄8
(384)
(543)
93⁄4
(248)
135⁄8
(346)
11⁄2
(38)
221⁄4
(565)
16 (406)
167⁄8(429)
Wheel Diameter = 125⁄8(321)
Shaft Diameter = 3/4 (19)
Outlet Area = 0.856 ft
2
(.08m2)
^Approximate Unit Weight = 147 lb. (67 kg)
All dimensions in inches (millimeters)
For additional discharge positions see page 11
^Weight shown is largest cataloged Open Drip Proof motor
151⁄2
(394)
(305)
12
207⁄8(530)
221⁄2(572)
9
(229)
(51)
13
(330)
2
e
v
r
u
c
m
e
t
s
y
s
s
i
h
t
f
o
t
f
e
l
e
h
t
o
t
t
c
e
l
e
s
t
o
n
o
D
Maximum BHP at given RPM = (RPM/1111)
3
Maximum RPM = 1400 and Minimum RPM = 370
Tip Speed (ft/min.) = 3.30 x RPM
Maximum Motor Frame Size = 145T
Model
Number
CFMOV
0.250.50.7511.251.51.7522.252.5
Static Pressure in Inches wg
RPM455
825964
BHP0.07
Sones5.7
RPM493631
10651244
BHP0.120.18
Sones6.39.3
RPM533665773871
13051525
BHP0.180.250.330.40
Sones7.110.210.310.5
RPM5807038068979831061
15451805
BHP0.260.350.430.520.620.71
Sones8.210.510.611.011.312.0
RPM6327438449311010108711581225
17852086
BHP0.360.470.570.670.770.880.991.09
Sones9.610.711.111.511.813.014.416.0
RPM686789883969104511161185125113131373
SFB-12
20252367
BHP0.490.610.740.850.961.071.191.321.441.56
Sones11.011.411.812.212.714.015.517.018.620
RPM7478379251008108311521217127813401399
22652647
BHP0.670.790.931.061.191.311.441.561.701.84
Sones11.812.212.612.913.915.216.618.119.822
RPM809889971104811221190125413141370
25052928
BHP0.881.001.151.301.451.591.731.872.00
Sones13.013.213.514.115.316.617.919.521
RPM873943101910931162123012921351
27453208
BHP1.131.261.411.581.751.912.062.21
Sones14.514.414.615.616.718.019.521
RPM9371001107111401205127013311390
29853489
BHP1.431.561.721.902.082.262.442.60
Sones16.115.816.217.118.219.62123
RPM1002106211241188125213121371
32253769
BHP1.771.922.082.262.462.662.85
Sones17.817.417.818.719.92123
Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (bhp) does not include transmission losses. Performance ratings do not include the
effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only.
16
Loading...
+ 36 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.