Document 451329
Hanging Vibration Isolator Kit
®
for Models SP and CSP
Assembly Instructions
Please read these instructions carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage!
4. Install hanging
Assembly
1. Upon receiving kit, check for any damage and
report it immediately to the shipper. Also, check to
see that all parts are accounted for. (See reverse
side for parts list).
2. Determine desired location of mounting bracket on
SP/CSP fan; 9/64 inch diameter holes are factory
prepunched for attaching mounting brackets.
If different locations are desired, drilling will be
required. (See CAUTION).
3. Insert neoprene grommets into large holes in
mounting brackets. Thread one nut into each
1/4-20 threaded support rod (supplied by others)
followed by one flat washer and a shaft sleeve.
Insert end of support rod and sleeve into grommet.
Install another flat washer and nut on end of
support rod, refer to Figure 1.
support rods
using the
following
vibration isolator
centerline
dimensions
shown in table
below.
Isolator Centerline Dimensions
Unit Size A B
B50-B200 4
A50-A190 5
A200-A390 6
A410, A510, A710, A780 9
A700 5
A900-A1050, A1410-A1550 9
A1750, A2150 9
A3600 9
All dimensions shown in inches (millimeters).
Maintenance
All fasteners should be checked for tightness each
time maintenance checks are performed prior to
restarting unit. A proper maintenance program will
help these units deliver years of dependable service.
1/4 - 20
hanging support
rod by others
1
⁄2 (114) 155⁄8 (397)
1
⁄2 (140) 15 (381)
3
⁄4 (171) 153⁄4 (400)
1
⁄4 (235) 193⁄4 (502)
1
⁄2 (140) 253⁄8 (645)
1
⁄4 (235) 251⁄2 (648)
1
⁄4 (235) 363⁄4 (933)
1
⁄4 (235) 471⁄4 (1200)
DANGER
Always disconnect, lock and tag power source
before installing or servicing. Failure to disconnect
power source can result in fire, shock or serious
Figure 1
®
injury.
CAUTION
When drilling be certain not to penetrate motor or
electrical components.
Hanging Vibration Isolator Kit for SP/CSP 1
Hanging Vibration Isolator Parts List
Qty Part No. Item Description
4 370007 Neoprene Grommets
8 415386 1/4-20 Zinc Plated Nuts
8 415084 Zinc Plated Flat Washers
4 472045 3/8 x 1/4 Shaft Sleeves
1/4-20 Threaded Rod
(by others)
1/4-20 Zinc Plated Nut
Zinc Plated Flat Washer
Shaft Sleeve
Neoprene Grommet
Zinc Plated Flat Washer
1/4-20 Zinc Plated Nut
Our Commitment
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice.
Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the
Library under Warranties.
Greenheck’s Centrifugal Ceiling and Cabinet Exhaust Fans
catalog provides additional information describing the
equipment, fan performance, available accessories, and
specification data.
®
Phone: 715.359.6171 • Fax: 715.355.2399 • Parts: 800.355.5354 • E-mail: gfcinfo@greenheck.com • Website: www.greenheck.com
451329 • Hanging Vibration Isolator Kit for SP/CSP, Rev. 5, March 2015 Copyright 2015 © Greenheck Fan Corporation2
AMCA Publication 410-96, Safety Practices for Users and
Installers of Industrial and Commercial Fans, provides
additional safety information. This publication can be
obtained from AMCA International, Inc. at www.amca.org.