Greenheck ESU-130S Installation Manual

®
Thin-line Louver
Frameless
Application and Design
ESU-130S is a frameless ultra thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into thru-wall air conditioning units.
Standard Construction
Frame . . . . . . . .Frameless
Blades . . . . . . . .Thin-line style, heavy gauge extruded 6063T5
Finish . . . . . . . . .Mill
Minimum Size . . 12.5 in. W x 6 in. H
Maximum Single Section Size . . .96 in. W x 48 in. H
ESU-130S
Options (at additional cost)
• A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paint
*Width and height dimensions furnished
approximately ¼ inch under size.
Free Area Chart (Sq. ft.)
Louver Height Inches
10 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96
10 0.27 0.36 0.62 0.90 1.18 1.46 1.74 2.03 2.22 2.50 2.79 3.07 3.35 3.55 3.83 4.11
12 0.33 0.44 0.76 1.11 1.46 1.80 2.15 2.50 2.74 3.09 3.43 3.78 4.12 4.37 4.71 5.06
15 0.42 0.57 0.98 1.42 1.87 2.31 2.76 3.20 3.51 3.96 4.40 4.84 5.29 5.60 6.05 6.49
18 0.51 0.70 1.20 1.74 2.28 2.82 3.36 3.90 4.29 4.83 5.37 5.91 6.45 6.84 7.38 7.92
21 0.61 0.82 1.41 2.05 2.69 3.33 3.97 4.61 5.06 5.70 6.34 6.98 7.62 8.07 8.71 9.35
24 0.70 0.95 1.63 2.36 3.10 3.84 4.57 5.31 5.83 6.57 7.31 8.04 8.78 9.30 10.04 10.78
27 0.79 1.07 1.84 2.68 3.51 4.35 5.18 6.01 6.61 7.44 8.27 9.11 9.95 10.54 11.37 12.20
30 0.89 1.20 2.06 2.99 3.92 4.85 5.79 6.72 7.38 8.31 9.24 10.18 11.11 11.77 12.70 13.63
33 0.98 1.32 2.27 3.31 4.33 5.36 6.39 7.43 8.15 9.18 10.21 11.24 12.27 13.00 14.03 15.06
36 1.07 1.45 2.49 3.62 4.74 5.87 7.00 8.13 8.93 10.05 11.18 12.31 13.44 14.24 15.36 16.49
39 1.13 1.57 2.70 3.93 5.15 6.38 7.61 8.83 9.70 10.92 12.15 13.38 14.60 15.47 16.69 17.92
42 1.26 1.70 2.92 4.25 5.56 6.89 8.21 9.54 10.47 11.79 13.12 14.44 15.77 16.70 18.02 19.35
45 1.35 1.82 3.14 4.56 5.97 7.40 8.82 10.24 11.25 12.66 14.09 15.51 16.93 17.92 19.35 20.77
48 1.44 1.95 3.35 4.87 6.39 7.91 9.43 10.95 12.02 13.53 15.05 16.58 18.10 19.17 20.68 22.20
Louver Width in Inches
ESU-130SPERFORMANCE DATA
Thin-line Louver
Extruded Aluminum
Airflow Resistance (Standard Air - .075 lb/ft
Pa
in. wg
1
0.9
200
100
90 80
70
60
50
40
30
0.09
20
0.08
0.07
Static Pressure Drop
0.06
0.05
10
0.04
9 8
0.03
7
6
5
0.02
ft/min:
m/s:
Test Size 48 in. x 48 in.
0.8
Standard Air - .075 lb/ft
0.7
0.6
0.5
0.4
0.3
0.2
0.1
200 300 400 500 600 700 800 900 1000 2000 3000
3
Intake
Exhaust
2345678910
3
)
Free Air Velocity
Model ESU-130S resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information.