Greenheck DCR 100 User Manual

Page 1
RCS Actuators
A.C. Voltages
MAR100 MAR120 MAR160 MAR250 MAR800
D.C. Voltages
DCR100 DCR160 DCR250 DCR800
Models
For on/off and modulating control of:
butterfly or plug valves
Multi-turn valve types
Rotary dampers
Rotating equipment
Typical Application
Standard: -40°F to +150°F
-40°C to +65°C
Optional: -60°F to +150°F
-50°C to +65°C
(Note: With Heaters Installed)
Optional: Compliance to NFPA 130, capable of operation after exposure to ambient temperature of 482°F (250°C) for a minimum of 1 hour
Temperature Range
115 VAC, 1 Phase, 50/60 Hz. 230 VAC, 1 Phase, 50/60 Hz. 24 VAC, 1 Phase, 50/60 Hz. 220 VAC, 3 Phase, 60 Hz. 440 VAC, 3 Phase, 60 Hz. 12 VDC 24 VDC
Voltage
1,500 to 10,000 inch pounds (13.5 to 112 newton meters)
Torque Range
NEMA 4/6/7 Enclosure
MAR Models Only
Canadian Standards Association
CSA NRTL/C—Enclosure 4 and 6
CSA NRTL/C—Class I, Divisions 1 & 2,
Groups C & D
CSA NRTL/C—Class II, Divisions 1 & 2,
Groups E, F & G
CSA NRTL/C—Approved to UL standard
No. 429, Electrically Operated Valves
CSA NRTL/C—Approved to UL
Standard No. 1203, Electrical Equipment for use in Explosion - proof And Dust - Ignition - proof Hazardous(Classified) Locations
Approvals
MAR Models Only
Canadian Standards Association
CSA NRTL/C—Enclosure 4
Approvals
NEMA 4 Enclosure
1.25 to 60 seconds for 90° revolution
6.6 and 12 RPM for multi-turns
Speed Range
AC (Single and Three Phase)Voltages
4 – SPDT Switches, PTC Heater
DC Voltages
2 – SPDT (High Current) Switches
Standard Features
MAR 100, 250
Page 2
The percentage of time the electric motor is energized vs. the time it is at rest, in reversing duty and with the actuator running at it’s rated load - maximum published torque.
Duty Cycle
• 12 motor starts (corrections) per minute.
• At the rated duty cycle for that model.
• With the speed of operation a minimum of 15 seconds for 90° or slower.
• With positioning accuracy of (+/-) 1% of total span.
Standard Modulating Duty Rating
* (N.L.A.) — No Load Ampere (L.R.A.) — Locked Rotor Ampere (1) — Open/Close Service (2) — Open/Close or Modulating Service
115 & 230 VAC, 1 Phase, 50/60 Hz.
MAR
Current Ratings Current Ratings
115 VAC 230 VAC
N.L.A.* L.R.A.* N.L.A.* L.R.A.*
.55 1.55 .25 .85
.50 .60 .30 .35
.35 .55 .20 .35
3.30 7.40 1.30 3.60
3.30 7.40 1.30 3.60
.75 1.65 .70 1.05
.60 1.60 .35 .90
.65 .70 .45 .50
.50 .60 .30 .35
3.30 7.40 .90 3.40
3.30 7.40 .90 3.40
1.60 2.20 1.00 1.25
1.10 1.80 .70 1.05
.75 1.65 .50 .95
.65 .70 .30 .35
3.30 7.40 .90 3.40
1.60 2.20 1.00 1.20
.55 1.55 .50 .95
3.30 7.40 .90 3.40
3.30 7.40 .90 3.40
Model
Output Torque Type Speed of Operation Duty Cycle Rating Duty Cycle Rating
Inch Pounds (N.m) 60 Hz. (50 Hz.) 115 Vac, 1Ph., 50/60 Hz. 230 Vac, 1Ph., 50/60 Hz.
MAR100-16 1,500 (169) Part Turn 16 seconds/90° 100% 50%
(19 seconds/90°)
(2) (2)
MAR100-30 1,800 (203) Part Turn 30 seconds/90° 100% 50%
(35 seconds/90°)
(2) (2)
MAR100-60 2500 (282) Part Turn 60 seconds/90° 100% 50%
(70 seconds/90°)
(2) (2)
MAR120-1.25 1,500 (169) Part Turn 1.25 seconds/90° 25% 25%
(2 seconds/90°)
(1) (1)
MAR120-1.25 1,500 (169) Multi-Turn 12 RPM 25% 25%
MT (10 RPM)
(2) (2)
MAR160-8 1,920 (217) Part Turn 8 seconds/90° 50% 50%
(9 seconds/90°)
(1) (1)
MAR160-16 2,000 (226) Part Turn 16 seconds/90° 75% 50%
(19 seconds/90°)
(2) (2)
MAR160-30 2,500 (282) Part Turn 30 seconds/90° 75% 50%
(35 seconds/90°)
(2) (2)
MAR160-60 2,800 (316) Part Turn 60 seconds/90° 100% 50%
(70 seconds/90°)
(2) (2)
MAR250-3 3,500 (395) Part Turn 3 seconds/90° 25% 50%
(4 seconds/90°)
(1) (1)
MAR250-3MT 3,500 (395) Multi-Turn 5 RPM 25% 50%
(4 RPM)
(2) (2)
MAR250-8 3,000 (339) Part Turn 8 seconds/90° 40% 50%
(9 seconds/90°)
(1) (1)
MAR250-16 4,000 (452) Part Turn 16 seconds/90° 50% 50%
(19 seconds/90°)
(2) (2)
MAR250-30 5,000 (565) Part Turn 30 seconds/90° 50% 50%
(35 seconds/90°)
(2) (2)
MAR250-60 5,000 (565) Part Turn 60 seconds/90° 75% 50%
(70 seconds/90°)
(2) (2)
MAR800-12 7,500 (847) Part Turn 12 seconds/90° 25% 25%
(14 seconds/90°)
(1) (1)
MAR800-30 10,000 (1,130) Part Turn 30 seconds/90° 40% 50%
(35 seconds/90°)
(2) (2)
MAR800-60 10,000 (1,130) Part Turn 60 seconds/90° 75% 50%
(70 seconds/90°)
(2) (2)
MAR1600-70 21,000 (2,373) Part Turn 70 seconds/90° 25% 50%
(82 seconds/90°)
(2) (2)
MAR 48,000 (5,424) Part Turn 170 seconds/90° 25% 50%
4000-170 (200 seconds/90°)
(2) (2)
Note — Multi-turn models are available with the following number of turns:
1.4, 5, 8, 13, 18, 26 or 50. Must be specified when the order is placed.
To operate multiple actuators in parallel from a single signal requires isolating relays in the field wiring. Consult factory.
Isolation Relays
Page 3
Standard: Four - single pole, double throw type (SPDT) with an option for 2 additional
Ratings: UL and CSA listed.
15 amp & 1/2 H.P. at 125 or 250 VAC 1/2 amp at 125 VDC; 1/4 amp at 250 VDC Lamp Load: 5 amp at 120 VAC
Optional: All double pole,
double throw type (DPDT).
Ratings: UL and CSA listed.
10 amp at 125/250 VAC (form ZZ); 1/2 H.P. at 125 VDC; 3/4 H.P. at 250 VAC
Limit Switches (MAR Models)
Ratings: UL and CSA listed.
MIL-PRF-8805 Qualified Listing 25 amp at 277 VAC; 1 H.P. at 125 VAC; 2 H.P. at 250 VAC
Limit Switches (DCR Models)
Model
Output Torque Type No Load Duty Cycle Rating Duty Cycle Rating
Inch Pounds (N.m)
Speed of Operation
12 VDC 24 VDC
DCR100-30 2,000 (225) Part Turn 11.5 seconds/90° 50% (2) 50% (2)
DCR160-16 2,200 (248) Part Turn 5.5 seconds/90° 50% (1) 50% (1)
DCR160-60 3,600 (406) Part Turn 22 seconds/90° 50% (2) 50% (2)
DCR250-8 3,000 (339) Part Turn 3.2 seconds/90° 50% (1) 50% (1)
DCR250-16 4,000 (452) Part Turn 5.7 seconds/90° 50% (1) 50% (1)
DCR250-30 5,000 (565) Part Turn 11.2 seconds/90° 50% (2) 50% (2)
DCR800-30 10,000 (1,130) Part Turn 13.3 seconds/90° 50% (2) 50% (2)
DCR800-60 10,000 (1,130) Part Turn 23 seconds/90° 50% (2) 50% (2)
12 & 24 VDC
DCR
Model
Output Torque Type Speed of Operation Duty Cycle Rating
Inch Pounds (N.m) 60 Hz. (50 Hz.) 24 VAC
MAR100-16 1,500 (169) Part Turn 16 seconds/90° 50% (2)
(19 seconds/90°)
MAR100-30 1,800 (203) Part Turn 30 seconds/90° 75% (2)
(35 seconds/90°)
MAR100-60 2,500 (282) Part Turn 60 seconds/90° 100% (2)
(70 seconds/90°)
MAR160-30 2,500 (282) Part Turn 30 seconds/90° 75% (2)
(35 seconds/90°)
MAR160-60 2,800 (316) Part-Turn 60 seconds/90° 75% (2)
(70 seconds/90°)
MAR250-60 5,000 (565) Part Turn 60 seconds/90° 50% (2)
(70 seconds/90°)
24 VAC
MAR
Current Ratings Current Ratings
12 VDC 24 VDC
N.L.A.* L.R.A.* N.L.A.* L.R.A.*
.90 5.80 .50 2.40
1.00 12.50 .75 6.80
.90 5.80 .50 2.40
1.00 22.00 .75 12.30
1.00 22.00 .75 12.30
1.00 12.50 .75 6.80
1.00 22.00 .75 12.30
1.00 12.50 .75 6.80
Current Ratings
24 VAC
N.L.A.* L.R.A.*
5.60 6.00
2.40 4.50
1.80 3.80
4.50 5.00
2.40 4.50
4.50 5.00
* (N.L.A.) — No Load Ampere (L.R.A.) — Locked Rotor Ampere (1) — Open/Close Service (2) — Open/Close or Modulating Service
To operate multiple actuators in parallel from a single signal requires isolating relays in the field wiring. Consult factory.
Isolation Relays
PTC (Positive Temperature Coefficient) Heater standard in an AC Voltage Models
Heater
Page 4
The percentage of time the electric motor is energized vs. the time it is at rest, in reversing duty and with the actuator running at it’s rated load - maximum published torque.
Duty Cycle
• 12 motor starts (corrections) per minute.
• At the rated duty cycle for that model.
• With the speed of operation a minimum of 15 seconds for 90° or slower.
• With positioning accuracy of (+/-) 1% of total span.
Standard Modulating Duty Rating
Note — Multi-turn models are available with the following number of turns:
1.4, 5, 8, 13, 18, 26 or 50. Must be specified when the order is placed.
Model
Output Torque Type Speed of Operation Duty Cycle Rating Duty Cycle Rating
Inch Pounds (N.m) 60 Hz. (50 Hz.) 220 Vac, 3Ph., 60 Hz. 440 Vac, 3Ph., 60 Hz.
MAR100-16 1,500 (169) Part Turn 16 seconds/90° 25% 25%
(19 seconds/90°)
MAR120-1.25 1,500 (169) Part Turn 1.25 seconds/90° 25% 25%
(2 seconds/90°)
MAR120-1.25 1,500 (169) Multi-Turn 12 RPM 25% 25%
MT (10 RPM)
MAR160-8 1,920 (217) Part Turn 8 seconds/90° 25% 25%
(9 seconds/90°)
MAR160-16 2,000 (226) Part Turn 16 seconds/90° 25% 25%
(19 seconds/90°)
MAR250-3 3,500 (316) Part Turn 3 seconds/90° 25% 25%
(4 seconds/90°)
MAR250-3MT 3,500 (316) Multi-Turn 5 RPM 25% 25%
(4 RPM)
MAR250-16 4,000 (452) Part Turn 16 seconds/90° 25% 25%
(19 seconds/90°)
MAR250-30 5,000 (565) Part Turn 30 seconds/90° 25% 25%
(35 seconds/90°)
MAR250-60 5,000 (565) Part Turn 60 seconds/90° 25% 25%
(70 seconds/90°)
MAR800-12 7,500 (847) Part Turn 12 seconds/90° 25% 25%
(14 seconds/90°)
MAR800-30 10,000 (1,130) Part Turn 30 seconds/90° 25% 25%
(35 seconds/90°)
MAR800-60 10,000 (1,130) Part Turn 60 seconds/90° 25% 25%
(70 seconds/90°)
MAR 21,000 (2,373) Part Turn 70 seconds/90° 25% 25%
1600-70 (80 seconds/90°)
MAR 48,000 (5,424) Part Turn 170 seconds/90° 25% 25%
4000-170 (200 seconds/90°)
220 & 440 VAC, 3 Phase, 60 Hz.
MAR
Current Ratings Current Ratings
220 VAC 440 VAC
N.L.A.* L.R.A.* N.L.A.* L.R.A.*
.34 1.20 .15 .75
1.60 3.50 .82 1.80
1.60 3.50 .82 1.80
.34 1.20 .15 .75
.34 1.20 .15 .75
1.60 3.50 .82 1.80
1.60 3.50 .82 1.80
.34 1.20 .15 .75
.34 1.20 .15 .75
.34 1.20 .15 .75
1.60 3.50 .82 1.80
.34 1.20 .15 .75
.34 1.20 .15 .75
1.60 3.50 .82 1.80
1.60 3.50 .82 1.80
* (N.L.A.) — No Load Ampere (L.R.A.) — Locked Rotor Ampere (1) — Open/Close Service (2) — Open/Close or Modulating Service
Note — Multi-turn models are available with the following number of turns: 1.4, 5, 8, 13, 18, 26 or 50. Must be specified when the order is placed.
MAR 100, 250
7.08
©2008 Dresser, Inc. RCS and DRESSER are registered trademarks of Dresser, Inc.
Industrial Products Group Dresser, Inc.
16240 Port Northwest Drive Houston, Texas 77041-2645 USA
Ph: 832.590.2306 Fax: 713.849.2879 Toll Free Phone: 800.945.9898 Email: rcs@dresser.com
www.dresser.com