Gree GWHN1407X2B8NK1BA, GWCN1809X2B8NK1BA, GWCN14B8NK1BA, GWHN14B8NK1BA, GWCN18B8NK1BA Owner's Manual

...
GREE ELECTRIC APPLIANCESI NC.OF ZHUHAI
GREE ELECTRIC APPLIANCESINC.OF ZHUHAI
C GREE 66163019 (GB4706.32-2004) V1.0
GWCN14(07X2)B8NK1BA GWHN14(07X2)B8NK1BA
GWCN18(09X2)B8NK1BA GWHN18(09X2)B8NK1BA
OWNER'S MANUAL
Thank you for choosing GREE air conditioner, for correct operation, please read this owner's manual carefully before operating the unit and keep it carefully for consultation.
GREEN HARBOR
Models:
GWCN14(07X2)B8NK3BA GWHN14(07X2)B8NK3BA
GWCN18(09X2)B8NK3BA GWHN18(09X2)B8NK3BA
GWHN1(0X2)B8NKBA
GWHN18(09X2)B8NKBA
■                  ................................
■                  ................................
■                        ..........................
■                            ......................
■                .................................12
■              ...................................
■                     .............................
CONTENTS
Operation and maintenance
Notices for operation
Models and specifications
Notices for operation
Names and functions of each part
Operation of wireless remote control
Clean and care
Troubleshooting
■                    .............................19
■                .................................20
■                .................................22
■                                 ...............
■                  ...............................17
Installation service
Notices for installation
Install indoor unit
Install outdoor unit
Test operation and check after installation
Thank you for choosing this air conditioner, please read this owner's
manual carefully before operating the unit and keep it carefully for consultation.
Installation dimension diagram
items should be forbidden
This symbol stands for the
items should be followed
This symbol stands for the
Please read the following carefully before operating.
WARNING
When having a burning smell
or smoke, please turn off the power
supply and contact with the service
may be damaged, and may cause
center .
If the abnormity still exists, the unit
electric shock or fire.
Don't operate the air conditioner
with wet hands.
Otherwise, it can cause electric shock or fire.
Never cut off or damage power cables and control wires. If the power cable and signal control wire were
damaged, change them by professional
Power must adopts the special
circuit to prevent fire.
Otherwise, it can cause electric
shock or fire.
Be sure to pull out the power
plug as the air conditioner not in use
for a long time.
Otherwise, the accumulated dusts
that may cause overheating or fire.
Never damage the electric wire
or use the electric wire, which is not
appointed.
Otherwise, it will cause overheating
or fire.
When cleaning, it is necessary
to stop driving and turn off the power
supply.
Cut off power supply
Otherwise, it may cause electric
shock or damage.
Rated voltage of this air cond­itioner 230V, with a tolerable fluctu­ation at The compressor will vibrate sharply if the voltage is
too low, resulting in damage to refrigerating system. Electrical elements are easy to damage if the voltage is too high.
The power supply must adopt
the special circuit that with air switch
protection and assure it has enough capacity. The unit will be turned on or off according to your requirement
automatically, please do not turn on
or turn off the unit frequently, othe-
rwise disadvantage effect may be caused to the unit.
Operation and maintenance-Notices for operation
±23V.
5℃
Earth:The ground
be connected!
If not, please ask the qualified person­nel to install. Furthermore, don't conn­ect each wire to the gas pipe, water
pipe, drainage pipe or any other impr-
oper places.
It can preclude the electricity wasted.
Keep room coo-
er than outside
about
Don't leave windows and
doors open for a long time
while operating the air conditi­oner.
Don't block the air intake or outlet
vents of both the outdoor and indoor
units.
Keep combustible spray away
from the units more than 1m.
It can cause
fire or explosion.
capacity or cause a malfunction.
It can decrease the air conditioning capacity.
Please note whether the install-
ed stand is firm enough.
If it is damaged, it may lead to the fall of the unit and cause injury.
As falling off the outdoor unit can be dangerous.
Don't step on the top of the outdoor unit or place something on it.
Don't attempt to repair
the air conditioner by yourself.
The wrong repair will lead to
electric shock or fire, so
you should contact
Notices for use
Be sure t
Otherwise, the accumulated dust
may cause fire or electric shock.
Earth:The ground
be connected!
If not, please ask the qualified person­nel to install. Furthermore, don't conn­ect each wire to the gas pipe, water
pipe, drainage pipe or any other impr-
oper places.
Select the most appropriate
temperature.
It can preclude the electricity wasted.
Keep room cool-
er than outside
about
Don't leave windows and
doors open for a long time
while operating the air conditi­oner.
Don't block the air intake or outlet
vents of both the outdoor and indoor
units.
Keep combustible spray away
from the units more than 1m.
It can cause fire
or explosion.
It can decrease the air conditioning
capacity or cause a malfunction.
It can decrease the air conditioning capacity.
Please note whether the install-
ed stand is firm enough.
If it is damaged, it may lead to the fall of the unit and cause injury.
As falling off the outdoor unit can be dangerous.
Don't step on the top of the outdoor unit or place something on it.
Don't attempt to repair
the air conditioner by yourself.
The wrong repair will lead to
electric
shock or fire, so you should contact with the service center for r
epairing.
Notices for use
Be sure to turn off the power
plug when not using the air co-
nditioner for a long time.
Otherwise, the accumulated dust
may cause fire or electric shock.
Swing louver
Don't blow the wind to animals and plants
directly. It can cause bad
influence to them.
Don't insert your hands or stick into the air
intake or outlet vents.
Splashing water on the air conditioner can
cause electric
shock and malfunction.
Don't place heater near the air
conditioner.
Or CO toxicosis may occur for imcomplete burning.
Don't apply the cold wind to the body for a
long time.
It can cause health problems.
Don't use the air conditioner for other purposes,
such as drying clothes, preserving foods, etc.
Notices for use
The power cords of this air conditioner adopt
X-type connection, please don't cut off or damage
the power cords and control cords. If they are
damaged, please ask the qualified personnel to
change them.
To adjust the airflow and direction appropriately.
At operating the louvers of air conditioner could be
adjusted by pressing the SWING button on wireless
remote control to change the airflow direction.
Guide louver
Models and specifications
***
Air volume (m
/h)
Model
Function
If there is any change, please see the nameplate for actual data.
Cooling capacity (W)
(3℃/23℃,4℃/26℃)
Heating capacity(W)
Rated voltage(V)
Rated frequency
Cooling/heating power current(A)
Cooling/heating power input(W)
Cooling/heating rated input(W)
Refrigerant volume (kg)
Water proof level
outline dimensioon
Climate type
Isolation
(Indoor/outdoor)weight (kg)
(WXHXD) cm
Noise(indoor/outdoor)dB(A)
Indoor unit:
Outdoor unit:
The above parameters are tested according to GB/T7725-2004, moreover, the cooling capacity, heating capacity, noise index are tested before leaving factory;
The max. input power are tested under the max. cooling condition
(27℃/--,24℃/18℃)
and max. heating condition
Indoor/outdoor
Cooling only
900×2 / --
36/58
430×2
730×2 / --
R22  0.85×2
T1
I
8×2 / 65
3.2×2 / --
2200×2
GWCN14(07X2)B8NK1BA
IP
900×2 / 910×2
36/58
430×2
730×2 / 755
×2
R22  0.90×2
8×2 / 65
3.2×2 / 3.4×2
2200×2
GWHN14(07X2)B8NK1BA
Cooling and heating
--
2400×2
50Hz
230V~
Cooling only
810×2 / --
36/56
430×2
650×2 / --
R410A 0.88×2
8×2 / 65
2.9×2 / --
2100×2
GWCN14(07X2)B8NK3BA
810×2 / 830×2
36/58
430×2
650×2 / 670×2
R410A 0.90×2
8×2 / 65
2.9×2 / 3.0×2
2100×2
GWHN14(07X2)B8NK3BA
Cooling and heating
--
2250×2
1000×2 / 1050×2
36/58
430×2
745×2 / 770×2
R407C 0.80×2
8×2 / 65
3.3×2 / 3.4×2
2100×2
GWHN14(07X2)B8NK2BA
Cooling and heating
2400×2
74.0×25.0×18.0
95.0×70.0×41.
Models and specifications
***
Air volume (m
/h)
Model
Function
If there is any change, please see the nameplate for actual data.
Cooling capacity (W)
(3℃/23℃,4℃/26℃)
Heating capacity(W)
Rated voltage(V)
Rated frequency
Cooling/heating power current(A)
Cooling/heating power input(W)
Cooling/heating rated input(W)
Refrigerant volume (kg)
Water proof level
outline dimensioon
Climate type
Isolation
(Indoor/outdoor)weight (kg)
(WXHXD) cm
Noise(indoor/outdoor)dB(A)
Indoor unit:
Outdoor unit:
The above parameters are tested according to GB/T7725-2004, moreover, the cooling capacity, heating capacity, noise index are tested before leaving factory;
The max. input power are tested under the max. cooling condition
(27℃/--,24℃/18℃)
and max. heating condition
Indoor/outdoor
Cooling only
1200×2 / --
36/58
430×2
955×2 / --
R22  0.80×2
T1
I
8×2 / 65
4.2×2 / --
2500×2
GWCN18(09X2)B8NK1BA
IP
1200×2 / 1200×2
36/58
430×2
955×2 / 1050×2
R22  0.90×2
8×2 / 65
4.2×2 / 4.6×2
2500×2
GWHN18(09X2)B8NK1BA
Cooling and heating
--
2850×2
50Hz
230V~
Cooling only
1235×2 / --
39/58
500×2
920×2 / --
R410A 0.75×2
8×2 / 65
4.1×2 / --
2600×2
GWCN18(09X2)B8NK3BA
1250×2 / 1250×2
39/59
500×2
995×2 / 1030×2
R410A 0.90×2
8×2 / 65
4.4×2 / 4.5×2
2600×2
GWHN18(09X2)B8NK3BA
Cooling and heating
--
2900×2
1150×2 / 1200×2
39/58
500×2
950×2 / 950×2
R407C 0.95×2
8×2 / 65
4.2×2 / 4.2×2
2500×2
GWHN18(09X2)B8NK2BA
Cooling and heating
2800×2
74.0×25.0×18.0
95.0×70.0×41.
*
*
*
*
* *
*
24℃
-
27℃
43
21℃
18℃
Notices for operation
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
Anti-freezing function
If the unit is running in COOL mode and in low termperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0, the indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
The unit absoebs heat from outdoor air,carrys and emits the heat in indoors to make indoor air temperature higher. Its heating capacity would be lower according to the low weather of outdoor ambient.
This heating air circulation system can enhance the indoor temperature
in a short while. If outdoor temperature got lower, please operate with the other heating ventilating
equipments.
Defrosting:
When outdoor temperature is low but with high humidity, after a long while running, frost will form on outdoor unit, that will affect the heating effect, at this time,
the auto defrosting function will act, the heat running will stop for 8-10mins.
During the auto defrost, the fan motors of indoor unit and outdoor unit will stop. During the defrost, the indoor indicator flashes, the outdoor unit may emit vapor.
This is due to the defrosting, it isn't malfunction.
After defrost finished,the heating will recover automatically.
Anti-freezing function:
In "HEAT" mode, under the following three states, if indoor heat exchanger didn't reach certain
temperature, indoor fan would not operate to prevent blowing out cool air:
(Within 3mins)
1.Heating starts. 2.After Auto defrosting finished. 3.Heating under the low temperature.
The conditions of unit can't normally run
The following temperature range protection device may act, that may cause stop running.
"HEAT"
running
Under the relative humidity above 80%( doors and windows opened) when cooling or dehu­midifying for a long time, there will be dew drip off near the air vent.
"COOL"
running
"DRY"
running
Outdoor temp above
Outdoor temp below
Indoor temp. above
Outdoor temp above
Indoor temp. below
Indoor temp. below