Permissible Excessive Operating Pressure for
the Discharge Side
Permissible Excessive Operating Pressure for
the Suction Side
MPa4.3
MPa2.5
Sound Pressure Level (H/M/L) dB (A) 50/-/-
Sound Power Level (H/M/L) dB (A) 60/-/-
Dimension (WXHXD) mm720X428X310
Dimension of Carton Box (LXWXH)mm765X350X475
Dimension of Package (LXWXH) mm768X353X490
Net Weight kg22
Gross Weightkg24
Refrigerant R410A
Refrigerant Chargekg0.5
Lengthm5
Gas Additional Chargeg/m20
Outer Diameter Liquid PipemmΦ6
Outer Diameter Gas PipemmΦ9.52
Max Distance Heightm10
Max Distance Lengthm15
Note: The connection pipe applies metric diameter.
Service Manual
The above data is subject to change without notice; please refer to the nameplate of the unit.
4
Technical Information
Service Manual
1.GWH07NA-K3NNE4E 2.GWH07NA-K3NND2E
3.GWH07NA-K3NNB3E 4.GWH07NA-K3NNA8E
Model
5.GWH07NA-K3NNA4E 6.GWH07NA-K3NND1E
7.GWH07NA-K3NND2E 8.GWH07NA-K3NNB5E
9.GWH07NA-K3NNA5E 10.GWH07NA-K3NNE1E
11.GWH07NA-K3NNC7E
1.CA403001401 2.CA149000603
3.CA138007301 4.CA173019301
Product Code
5.CA161013002 CA161013001 6.CA147004802
7.CA149000604 8.CA180010101
9.CA162020601 10.CA404007301
11.CA195007501
Power
Supply
Rated VoltageV~220-240
Rated FrequencyHz50
Phases1
Power Supply ModeIndoor
Cooling CapacityW2250
Heating CapacityW2300
Cooling Power InputW700
Heating Power InputW637
Cooling Power CurrentA3.10
Heating Power CurrentA2.92
Rated InputW1050
Rated CurrentA4.8
Air Flow Volume(SH/H/M/L/SL) m3/h400/360/320/290/Dehumidifying VolumeL/h0.6
EER W/W3.21
COP W/W3.61
SEER W/W/
HSPF W/W/
Application Aream
2
10-16
1.GWH07NA-K3NNE4E/I 2.GWH07NA-K3NND2E/I
3.GWH07NA-K3NNB3E/I 4.GWH07NA-K3NNA8E/I
Model of Indoor Unit
5.GWH07NA-K3NNA4E/I 6.GWH07NA-K3NND1E/I
7.GWH07NA-K3NND2E/I 8.GWH07NA-K3NNB5E/I
9.GWH07NA-K3NNA5E/I 10.GWH07NA-K3NNE1E/I
11.GWH07NA-K3NNC7E/I
1.CA403N01400 2.CA149N00601
3.CA138N07300 4.CA173N19300
Product Code of Indoor Unit
5.CA161N13002 CA161N13000 6.CA147N04801
7.CA149N00602 8.CA180N10100
9.CA162N20600 10.CA404N07300
11.CA195N07500
Fan TypeCross-ow
Diameter Length(DXL) mmΦ85X532
Fan Motor Cooling Speed(SH/H/M/L/SL) r/min1390/1280/1180/1080/Fan Motor Heating Speed(SH/H/M/L/SL) r/min1350/1250/1140/1040/Output of Fan MotorW10
Indoor Unit
Fan Motor RLAA0.15
Fan Motor Capacitor μF1
Input of HeaterW/
Evaporator Form Aluminum Fin-copper Tube
Pipe DiametermmΦ7
Row-n Gapmm2-1.5
Coil Length (LXDXW) mm526X25.4X228.6
Swing Motor ModelMP24AA
Output of Swing Motor W1.5
Fuse A3.15
Sound Pressure Level (SH/H/M/L/SL) dB (A) 37/35/31/28/Sound Power Level (SH/H/M/L/SL) dB (A) 47/45/41/38/Dimension (WXHXD) mm730X255X170
Dimension of Carton Box (LXWXH)mm784X311X236
Dimension of Package (LXWXH) mm787X314X251
Net Weight kg8
Gross Weightkg9.5
Permissible Excessive Operating Pressure for
the Discharge Side
Permissible Excessive Operating Pressure for
the Suction Side
MPa4.3
MPa2.5
Sound Pressure Level (H/M/L) dB (A) 48/-/-
Sound Power Level (H/M/L) dB (A) 58/-/-
Dimension (WXHXD) mm720X428X310
Dimension of Carton Box (LXWXH)mm765X350X475
Dimension of Package (LXWXH) mm768X353X490
Net Weight kg22.5
Gross Weightkg24.5
Refrigerant R410A
Refrigerant Chargekg0.6
Lengthm5
Gas Additional Chargeg/m20
Outer Diameter Liquid PipemmΦ6
Outer Diameter Gas PipemmΦ9.52
Max Distance Heightm10
Max Distance Lengthm15
Note: The connection pipe applies metric diameter.
Service Manual
The above data is subject to change without notice; please refer to the nameplate of the unit.
6
Technical Information
Service Manual
)
%
(
o i t a r y t i c a p a
C
24
2.2 Capacity Curve in Different Outdoor Temperature
CoolingHeating
110
100
90
80
70
60
50
40
Condition
Indoor:DB27
Indoor air flow: Super High
Pipe length:5m
°C
WB19
°C
32 33 34 35 36 37 38 39 40 41 42 43 44 45
Outdoor temp.( ) Outdoor temp.()
°C
120
)%(oitar yticapaC
100
80
60
40
20
0
-10510
2.3 Cooling and Heating Data Sheet in Rated Frequency
Cooling
Rated cooling condition(°C)
(DB/WB)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
27/1935/2407K0.85~1.0
Model
Pressure of gas pipe connecting
indoor and outdoor unit
Inlet and outlet pipe temperature
of heat exchanger
in:8~11
out:11~14
Condition Heating
Indoor:DB20
Indoor air flow: Super High
Pipe length:5m
°C
Fan speed of
indoor unit
in:75~85
out:37~43
Super HighHigh
°C
157-7 -502
Fan speed of
outdoor unit
Heating
Rated heatling condition(°C)
(DB/WB)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
20/-7/607K3.5~3.8
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Model
Pressure of gas pipe connecting
indoor and outdoor unit
Inlet and outlet pipe temperature
of heat exchanger
in:75~85
out:37~43
in:1~3
out:2~5
Fan speed of
indoor unit
Super HighHigh
Fan speed of
outdoor unit
Technical Information
7
3. Outline Dimension Diagram
D
W
40
3.1 Indoor Unit
Service Manual
H
22
Φ55
562
25
Unit:mm
Model WHD
07K730255170
65
Φ55
146
40
8
Technical Information
Service Manual
255
720
3.2 Outdoor Unit
GWH07NA-K3NNC7F/O
GWH07NA-K3NNE4E/O
428
660
440
310
286
Unit:mm
Technical Information
9
4. Refrigerant System Diagram
Indoorunit
Outdoor unit
Accumlator
COOLING
Discharge
Suction
Heatexchanger(evaporator)
Heatexchanger(condenser)
Valve
Valve
Liquidpipeside
Gas pipeside
Compressor
Strainer
Capillary
Cooling and heating model
Service Manual
Indoor unit
Heat
exchanger
(evaporator)
Connection pipe specication:
Liquid pipe:1/4" (6mm)
Gas pipe:3/8" (9.52mm)
Gas pipe
side
Valve
Liquid pipe
side
Valve
Outdoor unit
Discharge
Compressor
Strainer
Suction
Accumlator
4-Way valve
Heat
exchanger
(condenser)
StrainerCapillary
COOLING
HEATING
10
Technical Information
Service Manual
5. Electrical Part
5.1 Wiring Diagram
●Instruction
SymbolSymbol Color SymbolSymbol Color SymbolName
WHWhiteGNGreenCAPJumper cap
YEYellowBNBrownCOMPCompressor
RDRedBUBlueGrounding wire
YEGNYellow/GreenBKBlack//
VTVioletOGOrange//
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
These wiring diagrams are subject to change without notice; please refer to the one supplied with the unit.
Technical Information
Service Manual
34 5678
13
14
15
16
21
temperature
5.2 PCB Printed Diagram
● Top view
No. Name
1Neutral wire of cold plasma
2Terminal of PG Motor
3Neutral wire
4Live wire of cold plasma
54-way valve terminal
6Terminal of outdoor fan
Interface of up&down swing
7
9
10
motor
Feedback interface for PG
8
motor
9Jumper cap
10 Display interface
Interface of ambient
11
temperature sensor
Interface of pipe
12
sensor
13 Compressor control terminal
14 Live wire
15 Fuse
16 Capacitor for indoor fan
● Bottom view
1112
Technical Information
13
6. Function and Control
Icon Display on Remote Cont
Operation introduction of remote controll
Buttons on Remote Controller
1. ON/OFF Butto
Press this button to turn unit on/o
2. MODE Butto
Pressing this button once can select your required mode circularly as below(the corresponding icon
selected)
6.1 Remote Controller Introduction of YX1F
Service Manual
ON/OFF button
AUTO
COOL
DRY
FAN
HEAT
ON/OFF
T-ON T-OFF
_
FANSWING
SLEEP
MODE
+
TIMER
SWING
SLEEP
LOCK
SPEED
MODE button
+/- botton
FAN button
SWING button
SLEEP button
TIMER button
roller
Timer on Timer off
Sending signal
For auto operation
For cooling
For drying
For fan only
For heating
Set temperature
AUTO
COOL
DRY
FAN
HEAT
T-ON T-OFF
SWING
SLEEP
LOCK
SPEED
For air swing
For sleeping
For locking
For setting fan speed
Set time
er
Note:
● This is a general use remote controller, it could be used for the air conditionerswith multifunction; For some function, which the
model doesn't have, if pressthe corresponding button on the remote controller that the unit will keep theoriginal running status.
● When power is connected(stand by condition), you can operate the air conditioner through the remote controller.
● When unit is on, each time you press the button on remote controller, the sending signal icon " " on the display of remote
controller will blink once. If the air conditioner gives out a beep sound, it means the signal has been sent.
● When unit is off, set temperature will be displayed on the remote controller (If the light of indoor unit display is turned on, the
corresponding icon will be displayed);When unit is on, it will display the icon of the on-going function.
n
ff.
n
:
AUTOCOOLDRYFANHEAT
14
will be lit up after the mode is
Technical Information
Service Manual
When selecting auto mode, air conditioner will operate automatically according to ex-factory setting. Set temperature can't be
adjusted and won't be displayed either
FA
ess
FA
3. +/- butto
remote controller will change quickl
4.
Pressing this button can select fan speed circularly as:
5. SWING Butto
Press this button to turn on up&down air swing.
6. SLEEP
Under Cool, Heat, Dry mode, press this button to turn on Sleep function. Press this button to cancel Sleep function. Under Fan
A
Simple operationfi
1.After putting through power
as third notch for this air conditioner.)
. Press FAN button to adjust fan speed. (This function is not available in this air conditioner.)
When selecting cool mode, air conditioner will operate under cool mode. Then press + or -- button to adjust set temperature. Press
N button to adjust fan speed.
When selecting dry mode, air conditioner will operate at low fan speed under dry mode. In dry mode, fan speed can't be adjusted.
When selecting fan mode, air conditioner will operate in fan mode only. Then press FAN button to adjust fan speed.
When selecting heat mode, air conditioner will operate under heat mode. Then press + or -- button to adjust set temperature. Pr
N button to adjust fan speed.
Pressing + or - button once will increase or decrease set temperature by 1 °F(°C). Hold + or -- button for 2s, set temperature on
When setting Timer On, Timer Off or Clock, press + or -- button to adjust the time (See TIMER Button for setting details).
FAN Button
in this air conditioner. Speed 4 is the same with speed 3).
Note:
Under Auto mode, air conditioner will select proper fan speed automatically according to ex-factory setting.
Fan speed can't be adjusted under Dry mode.
uto mode, this function is unavailable.
7. TIMER Button
When unit is on, press this button to set Timer Off. T-OFF and H icon will be blinking. Within 5s, press + or - button to adjust the
time for Timer Off. Pressing + or - button once will increase or decrease the time by 0.5h. Hold + or - button for 2s, time will change
quickly. Release the button after your required set time is reached. Then press TIMER button to confirm it. T-OFF and H icon will
stop blinking.
When unit is off, press this button to set Timer On. T-ON and H icon will be blinking. Within 5s, press + or - button to adjust the
time for Timer On. Pressing + or - button once will increase or decrease the time by 0.5h. Hold + or - button for 2s, time will change
quickly. Release the button after your required set time is reached. Then press TIMER button to confirm it. T-ON and H icon will stop
blinking.
Cancel Timer On/Off: If Timer function is set up, press TIMER button once to review the remaining time. Within 5s, press TIMER
button again to cancel this function.
Note:
Range of time setting is: 0.5~24h
The interval between two motions can't exceed 5s, otherwise the remote controller will exit setting status.
n
y. Release the button after your required set temperature is reached.
SPEED 2 (equals to medium fan speed)SPEED 1 (equals to low fan speed)
SPEED 3 (equals to high fan speed)SPEED 4
n
Button
and
rst
2.Press “
3.Press “+” or “-” button to set your required temperature.(temperature can’t adjusted under AUTO mode)
4.Press “
Technical Information
” button to select your required operation mode: AUTO, COOL, DRY, FA N.
” button to select your required fan speed: auto, fi rst notch, second notch, third notch, fourth notch (fourthnotch is same
“
” button on remote controller to turn on the air conditioner.
15
Service Manual
1. Press the back side of remote controller on the spot marked with
push out the cover of battery box along the arrow direction.
2. Replace two No.7 (AAA
polar are correct
3. Reinstall the cover of battery box.
Note:
window of the indoor unit;
There should be no obstacle between them.
or wireless telephone; Remote controller should be close to indoor unit during
operation.
batteries.
remove
Replacement of Batteries in Remote Controller
, and then
1.5V) dry batteries and make sure the positions of + and --
.
During operation, point the signal sender of the remote controller at the receiving
The distance between signal sender and receiving window should be within 8m.
Signal may be interfered easily in the room where there is fl uorescent lamp
Replace new batteries of the same model when replacement is required.
If you don't use remote controller for a long time, please take out the batteries.
If the display on remote controller is fuzzy or if there's no display, please replace
battery
reinstall
cover of battery box
16
Technical Information
Service Manual
HEALTH SAVE Button
6.2 Remote Controller Introduction of YB1F2(XFAN)
Buttons on remote controller
1
FAN
AIR
HUMIDITY
FILTER
TURBO
AUTO
HEALTH
OPER
X-FAN
HOUR
ON/OFF
ON/OFF Button
2
MODE Button
3
+/- Button
4
FAN Button
5
Button
1
ON/OFF
3
4
FAN
7
8
11
Introduction for icons on display screen
Operation mode
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
:Outdoor ambient temp.
Up&down swing
9
X-FAN
TURBO
Child lock
Sleep mode
Temp. display type
12
Air mode
:Indoor ambient temp.:Set temp.
TEMP
SLEEP
MODE
TIMER
LIGHT
2
5
6
10
13
AUTO
FAN
HEALTH
AIR
HUMIDITY
FILTER
TURBO
6
Button
7
8
X-FAN Button
9
TEMP Button
10
TIMER Button
11
TURBO Button
12
SLEEP Button
13
LIGHT Button
OPER
X-FAN
HOUR
ON/OFF
(Note: X-FAN is same with BLOW)
Set fan speed
Send signal
Health mode
X-fan
Set temperature
Turbo mode
TIMER ON/TIMER OFF
Set time
Light
Left&right swing
Introduction for buttons on remote controller
Note:
This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model
doesnt have, if press the corresponding button on the remote controller that the unit will keep the original running status.
After putting through power, air conditioner will give out a sound and operation indicator "" is ON (red indicator). You can operate the air
conditioner through the remote co ntroller.
At ON status, after each pressing button on remote controller, the signal icon " " on remode controller will ash once. Air conditioner will
give out a sound, which indicates the signal has been sent to air conditioner.
At OFF status, display screen on remote controller displays set temperature. At on status, display screen on remote controller displays
the corresponding start up functions icon.
Technical Information
17
Service Manual
1.ON/OFF button
Press this button can turn on or turn off the air conditioner. After turning on the unit,operation indicator "" on indoor unit is ON (green
indicator. Color may be differ-ent for different models)and indoor unit gives out a sound.
2.MODE button
Press this button can select your required operation mode.
AUTO COOL DRYF ANHEAT
After selecting auto mode, air conditioner will operate automatically according to ambient temperature. Set temperature cant be adjusted
and also cant be displayed. Press "FAN" button can adjust fan speed. Press " " button can adjust swing angle.
After selecting cool mode, air conditioner operates under cool mode. Cool indicator " " on indoor unit is ON. You can press "+" or "-"
button to adjust set temperature. Press "FAN" button can adjust fan speed. Press " " button can adjus t swing angle.
After selecting dry mode, air conditioner operates under dry mode at low speed. Dry indicator " " on indoor unit is ON. Under dry mode,
fan speed cant be adjusted. Press " " button to adjust swing angle.
After selecting fan mode, air conditioner operates only under fan mode, All mode indicators on indoor unit is OFF. Operation indicator is
ON. Press "FAN" button can adjust fan speed. Press " " button to adjust swing angle.
After selecting heat mode, air conditioner operates under heat mode. Heat indicator " " on indoor unit is ON. You can press "+" or "-"
button to adjust set temperature. Press "FAN" button to adjust fan speed. Press " " button to adjust swing angle. (Cooling only unit cant
receive the signal for heating mode.)
Note:
For preventing cold wind, after starting up heating mode, indoor fan will blow fan afterdelaying 1-5min. (Details time is decided by indoor
ambient temperature) Temperature setting range on remote controller: 16oC~30oC(61oF~86oF) . Fan speed setting range: auto, low speed,
medium speed and high speed.
3."+" or "-" button
After each pressing of "+" or "-" button, it can increase or decrease set temperature 1oC(1oF~2oF) . Hold "+" or "-" button, 2s later, set
temperature on remote controller will change quickly. After reaching to your required time, loosen the button. Temperature indicator on
indoor unit will also change accordingly. (Temperature cant be adjusted under auto mode)
Under TIMER ON, TIMER OFF or Clock setting, you can press "+"or "-" button to adjust time. (Refer to TIMER button for details)
4.FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), low( ), medium(), high().
AUTO
Note:
Under AUTO Speed,IDU fan motor will adjust the fan speed (high, medium or low speed) according to ambient temperature.
Fan speed under dry mode is low speed.
5. button
Press this button to start or stop up & down swing function.The remote controller defaults to simple swing condition.
Press "+" button and " " button at the same time at unit OFF to switch between simple swing and static swing; " " blinks for 2 seconds.
In static swing condition, pressing " " button, the swing angle of up & down louver changes as below:
no display
(horizontal louvers
stops at current
position)
If the unit is turned off during swing operation,the louver will stop at present position.
Note:
When selecting " " with remote controller, its auto swing. Horizontal louver of air conditioner will swing up&down automatically at the
maximum angle.
When selecting "" with remote controller, it is the xed position swing. Horizontal louver of air conditioner will stop at
that position as shown by the icon to swing.
6. button
Press this button to start or stop left & right swing function. The remote controller defaults to simple swing condition.
Press "+" button and "" button at the same time at unit OFF to switch between simple swing and static swing; blinks for 2 seconds.
In static swing condition, pressing "" button, the swing angle of left & right louver changes as below:
18
no display
(horizontal
louvers stops
at current
position)
(swing angle is
displayed
dynamically)
Technical Information
Service Manual
If the unit is turned off during swing operation,the louver will stop at present position.
When selecting "" with remote controller, it is the xed position swing. Horizontal louver of air conditioner will stop at
that position as shown by the icon to swing.
When selecting "(
swing angle is displayed dynamically
)" its the circulating swing. Horizontal louver of air conditioner will swing circularly according to
the angle as shown by the icon.
Note:
There is no this function for the units. If press this key, the main unit will click, but it also runs under original status.
7.HEALTH/SAVE button
After pressing HEALTH button, remote controller will switch circularly as below: "HEALTH"→"AIR"→"AIR HEALTH"→"no display"
When selecting "HEALTH" by remote controller, HEALTH function will be started up.
When selecting "AIR" by remote controller, AIR function will be started up.
When selecting "AIT HEALTH", AIR and HEALTH function will be started up.
When theres no display on remote controller, AIR and HEALTH function will be turned off.
AIR function is applicable for some models.
SAVE function:
Under cool mode, press SAVE button and the unit will operate under SAVE mode. Dual-8nixie tube on remote controller displays "SE".
Air conditioner will operate at auto speed. Set temperature cant be adjusted. Press SAVE button again to exit SAVE mode. Air conditioner
turn back to original set speed and set temperature.
This function is applicable to partial of models.
8.X-FAN button
After pressing this button under cooling or dry mode, remote controller displays the character of "X-FAN" and X-FAN function is started up.
Press this button again to cancel X-FAN function. The character of "X-FAN" will disappear.
Note:
After starting up X-FAN function, when turning off the unit, indoor fan will continue to operate for a while at low speed to dry the residual
water inside the indoor unit.
When the unit operates under X-FAN mode, press "X-FAN" button can turn off X-FAN function. Indoor fan stops operation immediately.
9.TEMP button
Press this button can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature on indoor units display.
Temperature is set circularly by remote controller as below:
no display
When selecting " " by remote controller or no display, temperature indicator on indoor unit displays set temperature.
When selecting " " by remote controller, temperature indicator on indoor unit displays indoor ambient temperature.
When selecting "" by remote controller, temperature indicator on indoor unit displays outdoor ambient temperature.
Note:
Outdoor ambient temperature display may cant be selected for some models. When indoor unit receives "" signal, it displays indoor
set temperature.
Only for the model whose indoor unit has dual-8 display.
10.TIMER button
At ON status, press this button once can set TIMER OFF. The character of HOUR and OFF will ash.Press "+" or "-" button within 5s
can adjust the time of TEMER ON. After each pressing of "+" or "-" button, time will increase or decrease half an hour. When holding "+"
or "-" button, 2s later, the time will change quickly until to reach to your required time. After that, press "TIMER" button to conrm it. The
character of HOUR and OFF wont ash again.
Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status.
At OFF status, press this button once can set TIMER ON. Please refer to TIMER off for detailed operation.
Cancel TIMER ON: Press "TIMER" button again under TIMER ON status.
Note:
Time setting range: 0.5-24 hours.
Time interval between two operations cant exceed 5s. Otherwise, remote controller will exit the setting status automatically.
11.TURBO button
When pressing this button under cooling or heating mode, air conditioner will enter into quick cooling or quick heating mode. The
character of "TURBO" is displayed on remote controller. Press this button again to exit turbo function and the character of "TURBO" will be
disappeared on remote controller.
12.SLEEP button
Press this button under cooling, heating mode can start up sleep function."" icon will be displayed on remote controller. Press this button
again to cancel sleep function. "" icon on remote controller will be displayed.
13.LIGHT button
Press this button can turn off the light for indoor units display. "" icon on remote controller will disappear. Press this button again to turn
on the light for indoor units display. "" icon on remote controller will be displayed.
Technical Information
19
Service Manual
signal senderbattery
Cover of battery box
remove
Function introduction for combination buttons
Child lock function
Press "+" and "-" buttons simultaneously can turn on or turn off child lock function. When child lock function is started up, " " icon will be
displayed on remote controller. If operate remote controller " " icon will ash three times, while remote controller wont send signal.
Switchover function for temperature display
After turning off the unit by remote controller, press "-" button and "MODE" button simultaneously to switch between oC and °F.
Operation guide
1. After putting through the power, press "" button on remote controller to turn on the air conditioner.
2. Press "" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT.
MODE
ON/OFF
3. Press "+" or "-" button to set your required temperature. (Temperature cant be adjusted under auto mode).
4. Press "" button to set your required fan speed: auto, low, medium and high speed.
FAN
5. Press "" button to select fan blowing angle.
Replacement of batteries in remote controller
1. Press the back side of remote controller marked with " ", as shown in the g, and then push out the cover of battery box along the arrow
direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
NOTICE
During operation, point the remote control signal sender at the receiving window on indoor unit.
The distance between signal sender and receiving window should be no more than 8m, and there should
reinstall
be no obstacles between them.
Signal may be interfered easily in the room where there is uorescent lamp or wireless telephone; remote
controller should be close to indoor unit during operation.
Replace new batteries of the same model when replacement is required.
When you dont use remote controller for a long time, please take out the batteries.