Gree GPC08AH-A3NNC3B, GPC09AH-A3NNC3B, GPC10AH-A3NNC3B Owner's Manual

GPC08AH-A3NNC3B
GPC09AH-A3NNC3B GPC10AH-A3NNC3B
MODEL:
Change for Life
Portable Air Conditioner
Owner's Manual Residential Air Conditioners
manual carefully before operation and retain it for future reference.
Air Conditioners, please read this owner’s
SUMMARY 1
WORKING PRINCIPLE
1
STRUCTURE
3
OPERATING METHODS
4
Environmental temperature
6
OPERATION OF WIRELESS REMOTE CONTROL
7
DRAINAGE METHOD 11
10
ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE
13
MAINTENANCE
15
Names and functions of wireless remote control
7
Guide for operation- General operation
9
MALFUNCTION ANALYSIS
16
SAFE NOTE AND NOTICE
17
AFTER SALES SERVICE
18
Functions and operation methods of control panel
Guide for operation- Optional operation
9
5
Introduction for special function
Changing batteries and notices
9
CONTENTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Thank you for your selection, please read this instruction carefully before operating and keep it for consultation.
Mobile Air Conditioner is a type of small, multifunctional and movable air conditioner that contains
functions of COOL, DRY and separate ventilation, and it can be moved freely according to different
location and occasion, it is suitable for office and houses especially those with many rooms.This
product also contains the advantages of compact configuration, excellent process, elegant
appearance, convenient moving, low cost and low noise.
Note: Please read this instruction carefully before operating the unit. This instruction is only for
reference the specification parameters are subject to be changed without notice.
Under function of fan motor, indoor airflow changed into cooled air through evaporator then
blew out, while the indoor airflow changed into heated air though condenser then blew out.
There are 2 flues designed on structure of this unit: heated air is discharged from rear air outlet
vent on back air conditioner while cooled air from front air outlet vent of the unit. After guide
louver, gentle and steady cooled airflow is produced to reach needed cooling effect.
Working principle
SUMMARY
WORKING PRINCIPLE
- 1
-
evaporator
fluel
capillary
flue2
condenser
cool air
fan motor
heat air
Usage Location
1.Where room area is smaller than 15m ,and wall(or building)has well heat insulation effect.As shown
in following figure,if unit is in shown location,the cooling effect will bebetter.
2.If room area is larger than 20m ,for example workshop or factory,the unit can only offer cooled air to
partial area(as shown in following figure),and people in this area can enjoy better cooling effect.
- 2-
When only used as dehumidifier,remember to take off heat discharge pipe from unit and install it onto unit when the unit is used as air conditioner.Since partial indoor air will be heated as heat air and discharged to outside by discharge pipe after cyc-ling then outdoor air will enter to maintain balance air pressure,thus the air conditioner will only lower temperature of partial re-gional air of indoor room instead of turning entire indoor air to a lower temperature.
2
2
WORKING PRINCIPLE
window or wall
discharge pipe
cooled air
Heated air
Cooling
Flow direction
of cooled air
Mobile AC
Heat air
Room
region
1.5~2m
60~70
(Sector cooling area)
Rear
Air outlet vent
Upper air inlet grille
Lower air inlet grille
Control panel
Guide louver
Swing louver
Wheel
Power
Filters
Remote conrtoller box
cord
Front
STRUCTURE
- 3-
Power
The temp.range of this unit is16 35for cooli-
ng and ranges from 6
35 for dehumidifying
the unit.
It is better to adopt power lead with pick up current above 15A to prevent
sudden drop of voltage when the unit is running.
It is necessary to exchange broken power hose by special power hose.
When it is necessary to change power hose or maintain,please contact the
seller and have them repaired by professional personnel.
Earth must be conducted reliably and should connect to special earthing.
equipments in building to ensure well earth.
Do not replace fuse by steel or copper and capacity for fuse should be pro-
per.it is forbidden to fix power on blade or sharp objects to prevent creep-
age leaded by mangled wire.
Circuitry must be installed and fixed by professional personnel following
te national wiring regulations.Creepage protect switch with enough capa-
Place the unit on horizontal floor when using and ma-
intain a distance for above 50cm from walls,surface
of flammable objects or other obstructions.
city and.
Check before connecting power:
The normal running fluctuation range of voltage of the unit is 10% of
value listed on nameplate.Too high or too low of voltage will influence
OPERATING METHODS
15A solenoid hea t tripping air switch must be contained in circuitry. It is forbidden to connect earth
wire to water pipe or gas pipe,plug off power plug or cut off power supply when the unit is not going
to be used.
Earth
Power must contain reliable earth wire
Gas pipe
Water pipe
- 4-
Applyrange for COOL and DRY
Disposal requirement