![](/html/44/44bb/44bb81fbe9df7992368779a6989751f6004abd16694ca2b99293c4de0eff6f1e/bg1.png)
Great Plains Mfg., Inc.
Installation Instructions
Hydraulic Sprayer Pump
Scot High Volume
Used with:
TS750
•
TS1000
•
General Information
These instructions explain how to install the Scot high-volume
hydraulic pump. Powered by the tractor h ydr aulics , the high-volume pump pressurizes the sprayer contents f or high application
rates.
These instructions apply to:
507-058A PUMP - TS HIGH VOLUME HYD
Manual Update
Refer to the sprayer operator’s manual for detailed information
on safely operating, adjusting, troubleshooting and maintaining
the Scot high-volume hydraulic pump. Refer to the parts manual
for part identification.
Assembly Instructions
Refer to Figure 1.
1. Mount pump (1) on pump mount
using 3/8-inch bolts (2), washers
and nuts.
2. Use a t-bolt clamp (3) to connect
2-inch hose to adaptor on pump
inlet (4). Use a worm clamp (5) to
connect other end of hose to
hose barb on four-wa y cross .
NOTE: If sprayer is equipped with a
flush and rinse system, connect inlet
hose to fitting below three-way valve
on sprayer.
3. Use a t-bolt clamp (6) to connect
1 1/2-inch hose to elbow outlet (7)
on pump. Use a worm clamp (8)
to connect other end of hose to
Whirlfilter on sprayer.
4. Install hydraulic hoses (9) onto to
pump. Install a coupler (10) on
end of each hydraulic hose.
5. Using cable tie, secure hoses in
hose label (11) about 18 inches
from tractor quick couplers. Position label so port A hose is indicated for cylinder retraction and
port B hose is indicated for cylinder extension.
6. Tighten all clamps and fittings.
When you see this symbol, the subsequent instructions and
warnings are serious - follow without exception. Your life and
!
!
the lives of others depend on it!
• TS750 and TS1000 Operator’s Manual . . . . . . . . .500-104M
• TS750 and TS1000 Parts Manual . . . . . . . . . . . . . 500-071P
Before You Start
On page 2 is a detailed listing of parts included in the pump pack-
age. Use this list to inventory parts received.
Definitions
NOTE: Useful information related to the preceding topic.
© Copyright 1998 Printed 10/26/98
■
17391
Figure 1
Mounting Pump
507-526M
1
![](/html/44/44bb/44bb81fbe9df7992368779a6989751f6004abd16694ca2b99293c4de0eff6f1e/bg2.png)
Assembly
507-058A Pump - TS High Volume Hyd
Your Kit Includes:
Qty. Part No. Part Description
1 507-068L PUMP - SCOT 2 X 2 CENTR HYD
1 800-124C CLAMP WRM DRV #24 SS (1.061 800-144C CLAMP WRM DRV #40 SS (2.061 800-207C CLAMP T-BOLT STRAP (2.18-2.
1 800-208C CLAMP T-BOLT STRAP (1.81-2.
1 800-303C CABLE TIE 2 DIA MIN - BLK
2 802-017C HHCS 3/8-16X1 GR5
2 803-068C NUT HEX FLANGE 3/8-16 PLT
2 804-011C WASHER FLAT 3/8 USS PLT
2 811-390C HH1/2R1 087 3/4MORB
2 811-394C CP 3/4FORB MALE QD
1 817-348C PLASTIC HOSE LABEL
1 830-095C AD 2MNPT X 2HB POLYPROP
1 830-305C EL 2 MNPT X 1 1/2 HB
6.833 990-124R HOSE 2 ID EPDM SUCTION
2.458 990-181R HOSE 1 1/2 ID 150PSI EPDM
Great Plains Mfg., Inc.
Scot High Volume Hydraulic Sprayer Pump 507-526M 4/8/04
2