Trinix Multiviewer Quick Start Guide
Download the latest
Documentation
Please download the latest documentation
from the Grass Valley Web site.
Install the TMV Boards in
the correct Output Location
The TMV board must be installed in the
following Output ranges:
256X512
Jupiter: 128-159, 160-191, 192-223, 224-255,
256-287, 288-319, 320-351, and 352-383
Encore: 129-160, 161-192, 193-224, 225-256,
257-288, 289-320, 321-352, and 353-384
128X128*
Jupiter: 0-31 and 64-95 only
Encore: 1-32 and 65-96 only
256X256*
Jupiter: 0-31, 64-95, 128-159, and 192-223
Encore: 1-32, 65-96, 129-160, and 193-224
Installing the Trinix Multiviewer
Remove the top and bottom
screw for the rear Output panel.
Fasten the TMV rear panel to the frame
using the provided screws.
Trinix Multi-Viewer
(TMV) Connections
LAN
Connections
Reference
Connections
Discrete Audio
Connections
Monitor
Connections
512X512*
Jupiter: 0-31, 64-95, 128-159, and 192-223
Encore: 1-32, 65-96, 129-160, and 193-224
A TMV board may be placed in any Output
slot for the 128x256 and the 512x1024 Trinix
Routing switchers.
* For optimum power and thermal eciency,
each TMV board in a 128x128, 256x256 or
512x512 Trinix Frame requires two slots; one
slot for the board and an empty adjacent slot.
Follow Grass Valley’s recommended ESD
guidelines as explained in the
TMV Installation and Service Manual.
Remove the rear Output panel and
Place the TMV rear panel into
the Output slot.
Cascading
Connections
From the front of the Trinix frame,
insert the TMV boards into their
corresponding locations and then
lock them into place.
Part # 071881500
Trinix Multiviewer Quick Start Guide Continued
Connect Network
1
Connections
Connect the
TMV LAN to
the CNTL
connection
Connect Reference
2
Connections
Connect the
Facility LAN to
the FAC
connection
Connect MADI Discrete
3
Audio Connections
Connect
Discrete audio
to the MADI
INS connection
Connect Monitor
4
Connections
Connect Multiple
5
TMV Boards
Connect the
first cable
from the
CASCADE OUT
on the first
board to the
CASCADE IN
connection on
the second board.
Connect the
Reference to
the REF
connection
Unused connections
should be terminated
Connect to
the Monitor
connections
as needed
Install the TMV Software on
the TMV PC
Place the TMV CD into the PC and follow the Prompts.
Start the TMV Editor.
See the Trinix Multiviewer Installation and Service Manual.