Grass Valley Trinix Multiviewer Quick Start

Trinix Multiviewer Quick Start Guide
Download the latest Documentation
Please download the latest documentation from the Grass Valley Web site.
Install the TMV Boards in the correct Output Location
The TMV board must be installed in the following Output ranges:
256X512
Jupiter: 128-159, 160-191, 192-223, 224-255, 256-287, 288-319, 320-351, and 352-383 Encore: 129-160, 161-192, 193-224, 225-256, 257-288, 289-320, 321-352, and 353-384
128X128*
Jupiter: 0-31 and 64-95 only Encore: 1-32 and 65-96 only
256X256*
Jupiter: 0-31, 64-95, 128-159, and 192-223 Encore: 1-32, 65-96, 129-160, and 193-224
Installing the Trinix Multiviewer
Remove the top and bottom screw for the rear Output panel.
Fasten the TMV rear panel to the frame using the provided screws.
Trinix Multi-Viewer (TMV) Connections
LAN Connections
Reference Connections
Discrete Audio Connections
Monitor Connections
512X512*
Jupiter: 0-31, 64-95, 128-159, and 192-223 Encore: 1-32, 65-96, 129-160, and 193-224
A TMV board may be placed in any Output slot for the 128x256 and the 512x1024 Trinix Routing switchers.
* For optimum power and thermal eciency, each TMV board in a 128x128, 256x256 or 512x512 Trinix Frame requires two slots; one slot for the board and an empty adjacent slot.
Follow Grass Valley’s recommended ESD guidelines as explained in the TMV Installation and Service Manual.
Remove the rear Output panel and Place the TMV rear panel into the Output slot.
From the front of the Trinix frame, insert the TMV boards into their corresponding locations and then lock them into place.
Part # 071881500
Trinix Multiviewer Quick Start Guide Continued
Connect Network
1
Connections
Connect the TMV LAN to the CNTL connection
Connect Reference
2
Connections
Connect the Facility LAN to the FAC connection
Connect MADI Discrete
3
Audio Connections
Connect Discrete audio to the MADI INS connection
Connect Monitor
4
Connections
Connect Multiple
5
TMV Boards
Connect the first cable from the CASCADE OUT on the first board to the CASCADE IN connection on the second board.
Connect the Reference to the REF connection
Unused connections should be terminated
Connect to the Monitor connections as needed
Install the TMV Software on the TMV PC
Place the TMV CD into the PC and follow the Prompts. Start the TMV Editor. See the Trinix Multiviewer Installation and Service Manual.