17 rue du Petit Albi-BP 8244
95801 Cergy Pontoise
Cergy, France
Rennes, France
Rue du Clos Courtel
Cesson-Sevigne, Cedex
France
2300 South Decker Lake Blvd.
Salt Lake City, UT 84119
United States
Including its implementation, meets the requirements of the standard:
ISO 9001:2000
Scope:
The design, manufacture and support of video hardware and software products and
related systems.
This Certificate is valid until:June 14, 2009
This Certificate is valid as of:August 30, 2006
Certified for the first time:June 14, 2000
H. Pierre Sallé
President
KEMA-Registered Quality
The method of operation for quality certification is defined in the KEMA General Terms
And Conditions For Quality And Environmental Management Systems Certifications.
Integral publication of this certificate is allowed.
KEMA-Registered Quality, Inc.
4377 County Line Road
Chalfont, PA 18914
Ph: (215)997-4519
Fax: (215)997-3809
CRT 001 073004
Accredited By:
ANAB
SFP Optical Converters
1310NM-DRL, 1310NM-DTL, 1310NM-TRL OPTIONS
Installation Manual
071848900
DECEMBER 2006
Contacting Grass Valley
International
Support Centers
Local Support
Centers
(available
during normal
business hours)
France
24 x 7
Australia and New Zealand: +61 1300 721 495Central/South America: +55 11 5509 3443
Middle East: +971 4 299 64 40 Near East and Africa: +800 8080 2020 or +33 1 48 25 20 20
Europe
+800 8080 2020 or +33 1 48 25 20 20
+800 8080 2020 or +33 1 48 25 20 20
Hong Kong, Taiwan, Korea, Macau: +852 2531 3058 Indian Subcontinent: +91 22 24933476
This manual describes the features of a fiber optic submodule option in the
Kameleon Media Processing System and the 8900 Series used in the
GeckoFlex frame. Refer to the laser compliance information in the
GeckoFlex Frames Instuction Manual for safety information
As part of this module family, it is also subject to Safety and Regulatory
Compliance described in the 2000 Series and 8900 GeckoFlex frame and
power supply documentation (see the 2000 Series Frames Instruction Manual
and the GeckoFlex Instruction Manual).
SFP Optical Converters — Installation Manual7
Preface
8SFP Optical Converters — Installation Manual
SFP Optical Converter
Submodule Options
Introduction
This manual accompanies the optical/electrical converter submodule
options for fiber ready modules in the Kameleon 2000 Series and the
GeckoFlex 8900 Series. The low power, single mode SFP (Small-form Factor
Pluggable)/LC 1310nm optical converters include the following models:
•1310NM-DRL – Dual receiver (2 inputs),
•1310NM-DTL – Dual transmitter (2 outputs), or
•1310NM-TRL – Transceiver (1 input/1 output).
The fiber ready modules currently available in the Grass Valley Kameleon
2000 and GeckoFlex 8900 Series are listed below:
Kameleon 2000 Fiber Ready Modules
•2031RDA-SM SD Reclocking DA with Single-Mode Fiber I/F
•2031RDA-MM SD Reclocking DA with Multimode Fiber I/F
•2040RDA-FR Fiber Ready Wideband DA
•2040RDA-16FR Fiber Ready Wideband DA (16 outputs)
GeckoFlex 8900 Series Fiber Ready Modules
•8947RDA-FR SD/HD Distribution Amplifier
•8949MDA-CFR SD/HD Monitoring Distribution Amplifier
•8949MDA-SFR SD/HD Monitoring Distribution Amplifier
•8985FSP HD/SD Frame Sync, Proc Amp
•8985FS SD/HD Frame Sync
•8985PRC SD/HD Proc Amp
•8995UPC SD to HD Upconverter
•8995DNC HD to SD Downconverter
SFP Optical Converters—Installation Manual9
Kameleon 2000 Fiber Ready Modules
Kameleon 2000 Fiber Ready Modules
This section describes the installation and cabling of the SFP fiber optic submodules for the fiber ready modules in the Kameleon 2000 Series.
Installation
CAUTION The Fiber Optic submodule is static sensitive. Use static handling precautions
when installing or removing the submodule.
The SFP submodule installs in the connector cage on the rear module corresponding to the front module in the 2000 frame. Figure 1 illustrates a rear
module using the 2040RDA-16FR as an example.
The submodule is hot-pluggable and may be installed or removed with
power applied to the main module. The submodule type is identified by
name on the label or can be identified by the direction of the two arrows on
the label (Rx-Rx, Tx-Tx, or Tx-Rx).
Input
Figure 1. Rear Module Installation for 2040RDA-16FR
SFP Submodule
Outputs J1 – J8
J6J7J8
J15J16J17
J5J3J4J2J1
J14J12J13J11J10
Outputs J9 – J16
connector cage
2040
RDA-16
J9
To install the optional SFP submodule, refer to Figure 2 on page 11.
1. Locate the cage connector on the top right of the rear module
corresponding to the front module.
2. With the submodule handle in the up position, slide the metal casing,
label side up, into the cage connector on the rear module.
NoteWhen installed properly, the front end of the submodule will line up with the
BNCs. Do not try to force it in further.
8269_02
10SFP Optical Converters—Installation Manual
Cabling
Dual Optical Receiver
Kameleon 2000 Fiber Ready Modules
Figure 2. Installing SFP Submodule
Label
Arrow Indicators
Handle in
up position
8269_11
All cabling to the 2040RDA module sets is done on the corresponding rear
module at the back of the 2000 frame. Cabling to each of the submodule
types is described below.
With a dual optical receiver (1310NM-DRL) submodule installed, one of
the optical inputs can be configured as the module input (instead of the
coax BNC).
With the submodule handle in the up position, connect an optical input to
the left (Optic 1) or right (Optic 2) side of the optical connector as shown in
Figure 3.
Use local or remote controls to configure one of the optical inputs as the
module input as described in the instruction manual for the specific
module.
Figure 3. Dual Receiver Optical Inputs
8269_12
Optic 1 (Input)Optic 2 (Input)
SFP Optical Converters—Installation Manual11
Kameleon 2000 Fiber Ready Modules
Dual Optical Transmitter
With a dual optical transmitter (1310NM-DTL) submodule installed, the
output signal can be accessed from both optical outputs, Optic 1 (left) and
Optic 2 (right), in addition to the coax BNC outputs.
With the submodule handle in the up position, connect optical cables to one
or both outputs as shown in Figure 4.
These outputs must then be enabled with either local or remote configuration controls.
Figure 4. Dual Transmitter Optical Outputs
8269_13
Optic 1 (output)Optic 2 (output)
Optical Transceiver
With the optical transceiver (1310NM-TRL) submodule installed, the
2 input (right) can be configured as the module input (instead of the
Optic
coax BNC input) and the Optic
output (in addition to the coax BNC outputs).
For an optical input to the module, place the submodule handle in the up
position and connect the fiber cable to the Optic 2 input (right) as shown in
Figure 5. Use local or remote controls to configure this as the module input.
The output signal can also be accessed from the Optic 1 (left) connector
shown in Figure 5. Place the submodule handle in the up position and
connect an optical cable to this output. This output must be enabled with
local or remote configuration controls.
Figure 5. Dual Transceiver Optical Input and Output
1 output (left) can be enabled as a module
8269_14
Optic 1 (output)Optic 2 (input)
12SFP Optical Converters—Installation Manual
GeckoFlex Fiber Ready Modules
This section of the manual describes the installation and cabling of the SFP
fiber optic submodule for the fiber ready modules in the GeckoFlex 8900
frame. The front and rear modules must be installed first according to the
instructions in the specific GeckoFlex 8900 manual.
Installation
CAUTION The Fiber Optic submodule is static sensitive. Use static handling precautions
when installing or removing the submodule.
After the front and rear modules have been installed, install the SFP Fiber
Optic submodule option into the rear module metal cage labeled FIBER
Figure 6 on page 14). The SFP submodule is hot-pluggable and may be
(
installed or removed with power applied to the module.
NoteThe submodule type is identified by name on the label or can be identified by
the direction of the two arrow indicators on the label.
GeckoFlex Fiber Ready Modules
1. Slide the fiber optic device into the metal fiber cage with the label and
handle to the right.
2. Push the device in as far as it will go without forcing it. It will not go
completely into the cage.
3. Cable the fiber optic connectors according to the instructions given in
Cabling on page 11.
SFP Optical Converters—Installation Manual13
GeckoFlex Fiber Ready Modules
Cabling
Cabling to the fiber optic submodule is the same for all GeckoFlex modules
as shown in
Note8985FSP modules shipped before June/2006 have the fiber inputs and
Figure 6. Installing Fiber Optics Submodule
Figure 6.
outputs reversed. Refer to the 8985FSP Instruction Manual for verion 1.0.0
software for cabling information.
J7J9J8
Fiber Optic Cabling
1310NM-DRL
Fiber Rx 2
Handle
FIBER
Label
Arrow Indicators:
1310-DRL
1310-DTL
1310-TRL
Fiber Rx 1
Fiber Tx 2
Fiber Tx 1
Fiber Tx 2
Fiber Rx 1
1310NM-DTL
1310NM-TRL
8489_01
14SFP Optical Converters—Installation Manual
Configuration
Specifications
Configuration
Once the submodules have been installed and cabled, refer to the specific
2000 and 8900 module instruction manuals for configuration and operation
information. In most cases, the fiber inputs and outputs must be enabled
using onboard local controls or through the web page GUI.
Manuals are available on-line at no cost at this link:
http://www.thomsongrassvalley.com/docs/
From this location, select Broadcast Products, then Modular Products.
Table 1. Optical Submodule Specifications
ParameterValue
Fiber Inputs
Connector
Fiber mode
Minimum input power
Input signal formatsSerial digital component video conforming to the following formats:
Fiber Outputs
Connector
Fiber mode
Output power
Signal typeSerial digital component video conforming to the following formats: