Certificate Number: 510040.001
The Quality System of:
Thomson Inc, and it’s wordwide Grass Valley division affiliates DBA
GRASS VALLEY
Headquarters
400 Providence Mine Rd
Nevada City, CA 95959
United States
15655 SW Greystone Ct.
Beaverton, OR 97006
United States
10 Presidential Way
Suite 300
Woburn, MA 01801
United States
Kapittelweg 10
4827 HG Breda
The Nederlands
7140 Baymeadows Way
Ste 101
Jacksonville, FL 32256
United States
2300 So. Decker Lake Blvd.
Salt Lake City, UT 84119
United States
Rue du Clos Courtel
CS 31719
35517 Cesson-Sevigné Cedex
France
1 rue de l’Hautil
Z.I. des Boutries BP 150
78702 Conflans-Sainte
Honorine Cedex
France
Technopole Brest-Iroise
Site de la Pointe du Diable
CS 73808
29238 Brest Cedex 3
France
40 Rue de Bray
2 Rue des Landelles
35510 Cesson Sevigné
France
Spinnereistrasse 5
CH-5300 Turgi
Switzerland
Brunnenweg 9
D-64331 Weiterstadt
Germany
Carl-Benz-Strasse 6-8
67105 Schifferstadt
Germany
Including its implementation, meets the requirements of the standard:
ISO 9001:2008
Scope:
The design, manufacture and support of video and audio hardware and software products and
related systems
.
This Certificate is valid until: June 14, 2012
This Certificate is valid as of: June 14, 2009
Certified for the first time: June 14, 2000
H. Pierre Sallé
President
KEMA-Registered Quality
The method of operation for quality certification is defined in the KEMA General Terms
And Conditions For Quality And Environmental Management Systems Certifications.
Integral publication of this certificate is allowed.
KEMA-Registered Quality, Inc.
4377 County Line Road
Chalfont, PA 18914
Ph: (215)997-4519
Fax: (215)997-3809
CRT 001 073004
ccredited By:
ANAB
A
JUPITER
CONTROL SYSTEM
Release Notes
Software Version 7.9.0
071827513
NOVEMBER 2010
Contacting Grass Valley
International
Support Centers
Local Support
Centers
(available
during normal
business hours)
France
24 x 7
Australia and New Zealand: +61 1300 721 495Central/South America: +55 11 5509 3443
Middle East: +971 4 299 64 40 Near East and Africa: +800 8080 2020 or +33 1 48 25 20 20
Europe
+800 8080 2020 or +33 1 48 25 20 20
Hong Kong, Taiwan, Korea, Macau: +852 2531 3058 Indian Subcontinent: +91 22 24933476
This document describes new product enhancements that are provided in
the 7.9.0 version of the Jupiter Control system. The installation procedure
that should be used to upgrade a Jupiter system to the 7.9.0 version is also
described in this document (See the
NoteThis release only supports the English version of the Windows XP Profes-
sional Operating system.
Upgrading to 7.9.0 section).
NOVEMBER 2010
New Features in Jupiter Release 7.9.0 AccuSwitch
The 7.9.0 version of the Jupiter AccuSwitch Control system software has the
following enhancements and changes:
•Support for the CM-4400.
•Pro-Bel SW-P-08 Protocol.
•The Remote PC feature is no longer supported.
These features provide customers with improved control, convenience, and
flexibility when connecting and using Jupiter’s control panels.
Each of these features is described in detail below.
Support for the CM-4400
The 7.9.0 version of Jupiter supports the CM-4400, which is the new hardware platform for the AccuSwitch software.
You must set the Subnet Mask and Gateway IP addresses to run the 7.9
version of Jupiter on the CM-4400; these settings are not required on the
CM-4000.
JUPITER — Release Notes7
Version 7.9.0
Set the Subnet Mask and
Gateway IP Addresses
Setting the Subnet Mask and Gateway IP Addresses
Follow these steps to set the Subnet Mask and Gateway IP addresses:
1. Open the Jupiter Network Suite (JNS).
2. Select the Jupiter Settings option from the Tools menu (Tools> Jupiter
Settings). The Jupiter Settings dialog will then appear.
Figure 1. The Jupiter Settings Dialog
3. Enter the Subnet Mask and Gateway IP Addresses for your system. See
your System Administrator for this information.
NoteGrass Valley recommends that you enter the IP address of your Jupiter PC
and use 255.255.255.0 for the Subnet Mask if there is no Gateway. However,
only enter this information if your System Administrator does not provide the
needed information.
4. Click the Ok button to apply the changes.
8JUPITER — Release Notes
Pro-Bel SW-P-08 Protocol
CM 4000
P8R or P08 protocol
“Hi speed serial” port
or
“Port 4”
Pro-Bel router
Any available serial port
The 7.9.0 version of the Jupiter system supports two new protocol drivers,
for AccuSwitch, that implement parts of the Pro-Bel SW-P-08 protocol. The
first driver is implemented as a standard Remote Router control interface.
The second driver is implemented as an Automation, or as a Control panel,
interface.
Figure 2. Pro-Bel SW-P-08 Router Switcher Setup
Pro-Bel SW-P-08 Protocol
This section will describe the needed setup and configuration steps to use
the Pro-Bel SW-P-08 protocol for:
•Jupiter Router control
•Remote Router control
Jupiter Router Control
You will need to configure the Jupiter CM-4000 or CM-4400 to use a Pro-Bel
SW-P-08 Router Control port. This is accomplished by adding entries in the
Serial Protocol and MPK Devices tables.
For steps to configure a CM-4000 or CM-4400 or modifying, compiling, and
validating a configuration set, see the CM 4000 Control Module or the CM4400 Control Module manuals.
NoteThese steps assume that the CM-4000 or CM-4400 has been configured
properly.
Entering Serial Protocol Information
You may need to modify the Configuration set that is currently active; if so,
Grass Valley recommends that you make a copy for editing before making
these changes.
For more information about modifying the Configuration set, please see
the CM-4000 or CM-4400 Control Module manuals.
JUPITER — Release Notes9
Version 7.9.0
Protocol
Baud Rate
NoteOn the Title bar of the Jupiter Configurator application you will see the name
of the Configuration set. Make sure that the configuration set that is opened
is the correct set that you want to change.
Follow these steps to enter or modify the Serial Protocol table:
1. Select the Serial Protocol option from the Jupiter menu (Jupiter > Serial
Protocol). The Serial Protocol table will then open (Figure 3).
Figure 3. Example of the Serial Protocol Table
2. Double−click the protocol box that is associated with the Serial port. A
drop-down list will show the possible protocol types.
3. Select the P08 (SW-P-08 Control Panel) protocol.
4. Click anywhere else in the table to close the entry. The default Baud
rates will be selected automatically; however, the Baud rate may be
changed by clicking the drop down menu (Figure 4).
Figure 4. The P08(SW-P-08 Control Panel) Protocol on The Serial Protocol Table
5. Click the Apply button and then save your changes.
NoteThe serial line parameters are:
•38400 Baud
•8 data bits
•No parity
•1 stop bit
•The baud rate is adjustable