This unit generates, uses, and can radiate radio
frequency energy. If the unit is not properly installed and
used in accordance with this guide, it may cause
interference with radio communications. Operation with
non-certified peripheral devices is likely to result in
interference with radio and television reception. This
equipment has been tested and complies with the limits
in accordance with the specifications in:
FCC Part 15, Subpart B
CE EN50081-1:1992
CE EN50082-1:1992.
CONTACT MIRANDA
For technical assistance, please contact the Miranda
Technical Support centre nearest you:
The ADC-191p is the industry’s smallest component
analog video to 4:2:2 serial digital video ADC. This
product automatically detects 525-line and 625-line CAV
signals and provides a 4:2:2 serial digital output signal
conforming to the SMPTE 259M-C standard. Both
SMPTE/EBU and Betacam CAV sources are supported.
In addition, this feature-packed unit delivers ease-of-use,
a simplified design, easy installation and operation.
Y
B-Y
R-Y
COMPONENT IN
ADC4:2:2 OUT
Parallel
to serial
Figure 1: ADC-191p functional block diagram
1.2 Features
Automatic 525-line and 625-line format input
detection
Input standards supported: SMPTE/EBU and
Betacam
Time-base corrected and VTR-type sources
supported
Bi-color LED providing error status on input 4:2:2
signal
Very small packaging aluminum extruded body
ADC-191p | 1
Guide to Installation and Operation
2.0 Physical Layout
Figure 2 illustrates the ADC-191p’s major parts and their
locations. SMPTE/EBU or Betacam sources are
connected to the CAV input BNCs and the 4:2:2 serial
digital output is provided by the 4:2:2 output BNC. Error
status is provided by the status LED and mode settings
are configured by two 3-position slide switches. Finally,
the power source is connected to the power connector.
.
CAV inputs
3-position slide switches
Status LED
4:2:2 output
Figure 2: Physical layout of the ADC-191p
Power connector
2 | ADC-191p
Guide to Installation and Operation
3.0 Installation
3.1 Power Supply
The power supplies LKS-WSA and LKS-WSE, for 110 V
and 220 V operation respectively, are used to power the
ADC-191p. Each power supply provides a regulated +5
VDC@750 mA power source. The ADC-191p employs a
mini XLR-3 connector for its power needs. Figure 3
provides a detailed pinout of the male connector.
(male connector-facing)
13
Pin 1: Shield
Pin 2: GND
Pin 3: +5 VDC
2
Figure 3: Power connector pinout
ADC-191p | 3
Guide to Installation and Operation
3.2 CAV Inputs
The CAV inputs consist of green, blue, and red color
coded male BNC connectors. Male connectors are
provided so as to connect the ADC-191p directly to
source equipment. The supported CAV input standards
are SMPTE/EBU and Betacam. The Betacam standard
can be set with or without setup. The input Y/B-Y/R-Y
signals are to be connected to the green, blue, and red
BNCs respectively
Refer to section 4.0, Operation in order to select the
desired input CAV standard.
.
3.3 4:2:2 Output
The 4:2:2 serial digital output signal is provided by the
BNC labeled 4:2:2 OUT. The 4:2:2 output signal
conforms to the SMPTE 259M-C standard..
4 | ADC-191p
Guide to Installation and Operation
4.0 Operation
4.1 Switch Settings
Figure 4 shows the slide switch locations and functions.
Figure 4: ADC-191p switch settings
Input format switch (SW1)
SMPTE: For SMPTE/EBU CAV inputs, set SW1 to
this position. The Y/B-Y/R-Y inputs are to
be connected to the green, blue, and red
connectors respectively.
BETA 0: For BETA sources with 0 IRE setup, set
SW1 to this position.
BETA 7.5: For BETA sources with 7.5 IRE setup, set
SW1 to this position.
Input stability switch (SW2)
VTR: Set SW2 to VTR if the CAV inputs are VTR-
type or non-time based corrected signals.
Studio: For stable studio CAV sources, set SW2 to
this position.
ADC-191p | 5
Guide to Installation and Operation
4.2 Status LED
The bi-colored status LED is provided to identify any
input errors. The following lists the possible situations.
Green: Indicates the ADC-191p is powered and has
detected a valid CAV input signal.
Red: Indicates an error with the input signal has
been detected or simply, there is no input
signal installed.
6 | ADC-191p
Guide to Installation and Operation
5.0 Specifications
Input
Signal: Y, B-Y, R-Y 1 Vp-p nominal
with sync
Return loss: > 35 dB up to 5 MHz
Connector: 3 captive cables with 75 Ω male
BNCs
Output
Signal: 4:2:2 SMPTE 259M-C (270 Mbps)
Return loss: > 15 dB up to 270 MHz
Jitter: < 10 ns p-p
Connector : 75 Ω BNC
Processing performance
Signal path: 10 bits
Quantization: 12 bits
Freq. response: ±0.5 dB to 5 MHz
Processing delay: 3 lines
Electrical
Voltage requirement: +5 VDC
Power consumption: <3 W
Power connector: Mini XLR-3
Mechanical
Overall size: 102 mm x 25 mm x 18 mm
(4” x 1” x 0.7”)
Power cable length: 127 mm (5”)
Full spec. temp. range: 0° C (32° F) to 30° C (86° F)
ADC-191p | 7