Portable Datalogger
Product Guide
Versatile Dataloggers for a Wide Variety of Applications
COMPACT LOGGER - GL100 SERIES
midiLOGGER
GL840
series
DATALOGGERS
midiLOGGER
GL240
Portable Dataloggers
20ch isolated, multi-channel datalogger
Max.
sampling
Multifunction analog inputs
Pulse/Logic inputs
*1: WLAN is available in limited
A/D converter
20 mV to 100 V
TC: R, S, B, K, E, T, J, N, W (WRe5-26)
RTD: Pt100, Pt1000 (IEC750), JPt100 (JIS)
0 to 100% (the B-530 option is required)
Pulse
4ch (Accumulating, Instant, or Rotation)
*2
Logic
4ch
Humidity,
Voltage,
Pulse/Logic
channels
Flexible input system for wide array of applications
WLAN (option) capable for remote monitoring
Maximum sampling rate up to 10 ms
Extended memory capacity using SD memory card
Combine GL100 and GL840 by using WLAN
*2
Capable of up to 100VDC on GL840-M and
300VDC on GL840-WV
regions. *2: Select either Pulse or Logic input, and use optional input/output cable (B-513). *3: Sampling rate is dependent
Max.
*4
sampling
Multifunction analog inputs
Voltage
Temp.
Humidity
*3
Pulse/Logic inputs
A/D converter
20 mV to 100 V
TC: R, S, B, K, E, T, J, N, W (WRe5-26)
0 to 100% (the B-530 option is required)
Pulse
4ch (Accumulating, Instant, or Rotation)
*2
Logic
4ch
Humidity,
Voltage,
Pulse/Logic
on the number of channels used
channels
*2
Multifunction input in 10 isolated channels
Maximum sampling rate up to 10 ms
Extended memory capacity using SD memory card
WLAN (option) capable for remote monitoring
Combine GL100 and GL240 by using WLAN
*4: 4–20mA input requires B-551 Shunt Resistor.
.
*4
*3
Combining GL100-WL and GL240*/GL840
GL100-WL can be connected to the GL240* or GL840 as a remote sensor
GL100CompactLOGGER
series
Supports a wide array of measur ements with swappable sensors/modules
Connect to a PC or smart device via wireless LAN
Powered by USB or AA alkaline batteries
*4
*1: WLAN is available in limited regions
*4: 4–20mA input requires B-551 Shunt Resistor
GS sensors
One sensor slot is available for connecting one GS sensor from
the GL100 to the GL840 or the GL240.
Sensors
Temp./Humidity
GS-TH
Temp.: -20 to 85¡C
Humidity: 0 to 100% RH
Dew-point temp., Accumlated temp.
Dual port adapter
Dual port adapter
GS-DPA
Connects two sensors of
GS-TH, GS-CO2, GS-LXUV.
Extension cable
Extension cable for
input module
GS-EXC
Cable length: 1.5 m
Acceleration/Temp.
GS-3AT
Try-axial: max. 10 G
Temp.: -10 to 50¡C
Input terminal / Adapter
Thermistor terminal
GS-4TSR
: -40 to 120
Temp.
4ch
4ch
Thermistor sensor
Normal type
GS-103AT-4P
¡C*
* It varies by the sensor.
Logic or Pluse
Ultrathin type
GS-103JT-4P
Carbon dioxide (CO2)
GS-CO2
CO
concentration:
2
0 to 9999 ppm
Current sonsor adapter
GS-DPA-AC
50, 100, 200 A
Max.
Single-phase,
2ch
three-phase power system
AC current sensor
Illuminance/UV
GS-LXUV
Illuminance: 0 to 200 klx
UV intensity: 0 to 30 mW/cm
Accumlated Illuminance and UV
Voltage/Temp. terminal
GS-4VT
Voltage: max. 50 V
4ch
Temp.: TC K or T
4ch
Logic or Pluse
200 A100 A50 A
2