Portable Datalogger
Product Guide
Versatile Dataloggers for a Wide Variety of Applications
COMPACT LOGGER - GL100 SERIES
midiLOGGER
GL840
series
DATALOGGERS
midiLOGGER
GL240

Portable Dataloggers
20ch isolated, multi-channel datalogger
Max.
sampling
Multifunction analog inputs
Pulse/Logic inputs
*1: WLAN is available in limited
A/D converter
20 mV to 100 V
TC: R, S, B, K, E, T, J, N, W (WRe5-26)
RTD: Pt100, Pt1000 (IEC750), JPt100 (JIS)
0 to 100% (the B-530 option is required)
Pulse
4ch (Accumulating, Instant, or Rotation)
*2
Logic
4ch
Humidity,
Voltage,
Pulse/Logic
channels
Flexible input system for wide array of applications
WLAN (option) capable for remote monitoring
Maximum sampling rate up to 10 ms
Extended memory capacity using SD memory card
Combine GL100 and GL840 by using WLAN
*2
Capable of up to 100VDC on GL840-M and
300VDC on GL840-WV
regions. *2: Select either Pulse or Logic input, and use optional input/output cable (B-513). *3: Sampling rate is dependent
Max.
*4
sampling
Multifunction analog inputs
Voltage
Temp.
Humidity
*3
Pulse/Logic inputs
A/D converter
20 mV to 100 V
TC: R, S, B, K, E, T, J, N, W (WRe5-26)
0 to 100% (the B-530 option is required)
Pulse
4ch (Accumulating, Instant, or Rotation)
*2
Logic
4ch
Humidity,
Voltage,
Pulse/Logic
on the number of channels used
channels
*2
Multifunction input in 10 isolated channels
Maximum sampling rate up to 10 ms
Extended memory capacity using SD memory card
WLAN (option) capable for remote monitoring
Combine GL100 and GL240 by using WLAN
*4: 4–20mA input requires B-551 Shunt Resistor.
.
*4
*3
Combining GL100-WL and GL240*/GL840
GL100-WL can be connected to the GL240* or GL840 as a remote sensor
GL100CompactLOGGER
series
Supports a wide array of measur ements with swappable sensors/modules
Connect to a PC or smart device via wireless LAN
Powered by USB or AA alkaline batteries
*4
*1: WLAN is available in limited regions
*4: 4–20mA input requires B-551 Shunt Resistor
GS sensors
One sensor slot is available for connecting one GS sensor from
the GL100 to the GL840 or the GL240.
Sensors
Temp./Humidity
GS-TH
Temp.: -20 to 85¡C
Humidity: 0 to 100% RH
Dew-point temp., Accumlated temp.
Dual port adapter
Dual port adapter
GS-DPA
Connects two sensors of
GS-TH, GS-CO2, GS-LXUV.
Extension cable
Extension cable for
input module
GS-EXC
Cable length: 1.5 m
Acceleration/Temp.
GS-3AT
Try-axial: max. 10 G
Temp.: -10 to 50¡C
Input terminal / Adapter
Thermistor terminal
GS-4TSR
: -40 to 120
Temp.
4ch
4ch
Thermistor sensor
Normal type
GS-103AT-4P
¡C*
* It varies by the sensor.
Logic or Pluse
Ultrathin type
GS-103JT-4P
Carbon dioxide (CO2)
GS-CO2
CO
concentration:
2
0 to 9999 ppm
Current sonsor adapter
GS-DPA-AC
50, 100, 200 A
Max.
Single-phase,
2ch
three-phase power system
AC current sensor
Illuminance/UV
GS-LXUV
Illuminance: 0 to 200 klx
UV intensity: 0 to 30 mW/cm
Accumlated Illuminance and UV
Voltage/Temp. terminal
GS-4VT
Voltage: max. 50 V
4ch
Temp.: TC K or T
4ch
Logic or Pluse
200 A100 A50 A
2

Datalogger Channel Extension Capabilities on the GL840
The standard configuration of GL840s come with a detachable terminal.
The Multi-input model (GL840-M) has a removable terminal B-564, and the
Withstand Voltage model (GL840-WV) has a removable terminal B-565.
Example of standard configuration expanded to 40 channels
To add or expand additional channels, the original terminal from the
main body connects with the B-566 Terminal Base allowing you to add
additional terminals for up to 200 channels or 10 terminal blocks.
Expand channels by
connecting Terminals and Base
20ch
20ch
20ch
Options and Accessories
Model Item GL240 GL840 series GL900 series GL7000 series
B-513 Input/Output cable for GL series Yes Yes Yes Yes
B-514 DC drive cable Yes Yes Yes N/A
B-530 Humidity sensor Yes Yes Yes Yes
B-564 Input terminal (M type) N/A Yes N/AN /A
B-565 Input terminal (WV type)
B-566 N/A Yes N/AN /A
B-567-05,-20 Connection cable N/A Yes N/AN /A
B-568 Wireless LAN unit Yes Yes N/AN /A
B-569 Battery pack Yes Yes Yes N/A
ACADP-20 AC power adapter Yes Yes N/AN /A
ACADP-90 AC power adapter N/AN /A Yes N/A
RIC-10 Probe set for Logic input N/AN /A N/A Yes
RIC-142 Input cable, BNC - BNC N/AN /A Yes Yes
RIC-143 Input cable, Banana - BNC N/AN /A Yes Yes
RIC-144 Clip, Alligator (small size) for RIC-143,147 N/AN /A Yes Yes
RIC-145 Clip, Alligator (middle size) for RIC-143,147 N/AN /A Yes Yes
RIC-146 Clip, Grabber for RIC-143,147 N/AN /A Yes Yes
RIC-147
B-551
Base of input terminal
Input cable, Banana - BNC (High voltage)
High precision 250ohm shunt resistor for
4–20mA current loop
N/A Yes N/AN /A
N/AN /A Yes
YesYesYes
Yes
N/A
by connecting Terminals and Base
20ch
B-513
Input / Output cable
B-566
Base of input terminal
ACADP-90
AC power adapter
Shunt Resistor B-551
Expand and extend channels
with Extension Cables
Extension Cable* (B-567)
available in 50cm and 2 m
20ch20ch
*Max extension length up to 20 metersMaximum 10 Terminal Blocks can be connected to one GL840-M or GL840-WV
RIC-142
Input cable
B-564
Input terminal (M type)
B-569
Battery pack
RIC-143, -144, -145, -146, -147
Input cable, Clip
RIC-146
RIC-145
RIC-144
B-514
DC drive cable
B-567-05 or -20
Connection cable
RIC-10
Probe set for Logic input
B-530
Humidity sensor
B-568
Wireless LAN unit
B-565
Input terminal (WV type)
ACADP-20
AC power adapter
RIC-143
RIC-147

Download on the
App Store
• Due to the possibility of equipment or PC failure, data files on the instrument is not guaranteed to be stored on the memory. Please backup your data to avoid data loss.
• Brand names and product names listed in this brochure are the trademarks or registered trademarks of their respective owners.
• Items mentioned are subject to change without notice. For more information about product, please check the web site or contact your local representative.
Use equipment correctly and safely!
• Use only in accordance with product’s user manual
•
To avoid malfunction or an electric shock by current leakage or voltage, please ensure a ground connection and use according to the specification.