Be sure to read all of the following notes before attempting to use the GL100 Petit LOGGER.
1. Note on the CE Marking
The GL100 Petit LOGGER complies with the following standards.
• EN 61326-1 (Class A) standard based on the EMC directive (2004/108/EC)
• EN 61010-1:2010 3rd standard based on the LVD directive (2006/95/ EC)
• EN 301 489-17/-1, EN 300 328 standards based on the R&TTE directive (1999/5/EC)
Although the GL100 complies with the above-mentioned standards, be
sure to use it correctly in accordance with the instructions and notes provided in this manual.
Moreover, use of the GL100 by incorrect procedures may result in
damage to the GL100 or may invalidate its safeguards. Please confirm all of its notes regarding use and other related information to ensure correct use.
2. Warning
This is a Class A product according to the EMC directive. In a domestic
environment, this product may cause radio interference or may be affected by radio interference to the extent that proper measurement cannot be performed.
3. Notes on Radio Law
This GL100-WL contains a wireless module that Radio Law certified.
Make sure to note the following points:
Do not remove the technical standards compliance label. Do not use
the device if it does not have a label on it.
This GL100 uses the 2.4GHz frequency band.
The following devices and transmitters use the same frequencies and should not be used near this GL100:
• Microwave ovens
• Pacemakers and other industrial, science, and medical devices
• Radio transmitters used in mobile body identification devices on factory production lines, etc. (transmitters requiring licensing)
• Specified low-power radio transmitters (transmitters not requiring licensing) Communications may become slower or impossible due to radio interference.
The signal may be weak or communications may become slower or
impossible depending on the circumstances this GL100 is used in. Take particular note of steel-reinforced, metal, concrete, and other structural materials that can inhibit radio waves.
This GL100 is meant for use in Japan, the US, and Europe. It has not
been certified for use under any other country’s radio laws. The following are each region’s certification marks.
Japan
R 201-135002
Canada
Contains IC ID:9154A-GS1011MIPS
4. Notes for Safe Operation
(1) When connected to high-voltage signal through an analogue signal from
4ch voltage / temperature terminal (GS-4VT), do not touch the central line of the input terminal’s signal line. There is a risk of electric shock due to high voltage.
5. Notes on Functions and Performance
(1) Use AA alkaline batteries. Using other types of batteries may cause
damage to the device.
(2) Using the module, sensor, etc. with the vent hole covered may result in
inaccurate measurements.
US
Contains FCC ID:YOPGS1011MIPS
Europe
CE Mark
(3) Using this GL100 in the following environments may cause inaccurate
measurements or damage:
• Places with high temperatures or high humidity, such as direct sunlight and heaters. Allowable temperature range: -10 to 50°C, allowable humidity range: 0 to 80% RH, non-condensing
If Condensation Occurs
Condensation occurs in the form of water droplets on the device surfaces and interior when the GL100 is moved from a cold location to a warm one. Using the GL100 with condensation will cause the GL100 to malfunction. Wait until the condensation has evaporated before turning on the power.
CAUTION
When Temperature and humidity sensors (GS-TH) and GL100-N/GL100-WL are used at the same time, they should be used in the GL100-N/GL100-WL operating environment.
• Locations subject to excessive salt spray or heavy fumes from corrosive gas or solvents.
• Excessively dusty locations.
• Locations subject to strong vibrations or shock.
• Locations subject to surge voltages and/or electromagnetic interference.
(4) If the GL100 becomes soiled, wipe it off using a soft, dry cloth. Do not use
the organic solvents (such as thinner or benzene).
(5) Do not use the GL100 in the vicinity of other devices which are
susceptible to electromagnetic interference.
(6) Measured results may not conform to the stated specifications if the
GL100 is used in an environment which is subject to strong electromagnetic interference.
(7) Position the input signal cables as far away as possible from any other
cables which are likely to cause electromagnetic interference.
(8) GS-TH Temperature and Humidity Sensors:
• Humidity sensors measure the change in dielectric capacity of water adsorption. As a result, humidity from organic materials such as fine particles or exhaust gas may have an effect on the sensor. Use in environments with large quantities of these organic materials may lead to significant measurement inaccuracies.
(9) GS-CO2 CO2 Sensor:
• Because exhaled CO2 may have an effect on the sensor readings, do not use the sensor to take measurements near the face. Additionally, should air flow to the sensor be blocked, it will result in inaccurate readings, so be sure to keep vent holes open.
(10) GS-LXUV Illumination / Ultraviolet Sensor
When measuring illumination or ultraviolet light that can have harmful effects on the eyes or skin, be sure to use protective eyewear, shielding, etc.
• If the sensor becomes dirty it may affect measurements, so wipe it with a soft cloth when it becomes dirty.
• Take care to avoid cracking the sensor when handling it. If the sensor is damaged or cracked it may affect measurements, so replace the sensor.
(11) Others
• The GS-TH temperature and humidity sensor, the GS-CO2 CO2 sensor, and the S-LXUV illumination / ultraviolet sensor may gradually deteriorate over time depending on usage circumstances and environment, so we recommend periodically replacing these sensors every year or so.
• The GL100-N/GL100-WL units meet IP54 standards when the sensor or sensor module is connected and then the connector cover and battery cover are closed. Note that you cannot use the GL100-N/GL100WL units with devices that do not meet IP54 standards (except for the 3-axis acceleration sensor) when sensors and sensor modules are located in the same environments. Additionally, when there is deterioration or damage to the gasket on the connector cover or battery cover of the GL100-N/GL100-WL, it no longer meets IP54 standards, so be sure to either periodically replace them or have them repaired.
• If the non-optional device is connected to the GL100-N/GL100-WL’s module connection terminal or the GS-DPA branch adapter connector, the GL100-N/GL100-WL or branch adapter may be damaged. Please do not connect it.
6. Operating Environment
This section explains the operating environment for the GL100.
1)
Ambient Temperature and Humidity ( Use the GL100 within the following ranges)
• Temperature range: -10 to 50°C
• Humidity range: 20% to 80% RH, non-condensing
2) Environment
• This GL100 meets IP54 standards for simple waterproofing and dustproofing but should not be used in environments that the sensor and/or module are not designed for.
• See part (3) of Section 5 (Notes on Function and Performance).
3) Installation Category (Overvoltage Category)
• The GL100 belongs to Installation Category II defined in IEC 60664-1.
• Never use the GL100 for Installation Category III or IV.
4) Overvoltage Category
• Overvoltage categories as defined by IEC 61010 are as follows: GL100-N/GL100-WL: Overvoltage category I When connected to a PC/AC adapter: Overvoltage category II
*
Be sure to use either a commercially available AC adapter or a PC (with a
IEC 60950-1 certified Limited Power Source USB output) with this GL100.
* Furthermore, do not use this GL100 with IEC 61010-defined
overvoltage category III or IV.
5) Altitude
• This GL100 can be used at altitudes up to 2,000m.
6) Power
• Two alkaline batteries or a USB cable connection (5V, 200 mA or higher) can be used to provide power.
7) Degree of Contamination
This GL100 is IEC 60664-1-certified for use in up to Contamination Degree 2.
8) Use
• This GL100 is intended for use as industrial equipment.
(This GL100 is designed for indoor use. Do not use in the following locations.)
Notes on the Use of This Manual
(1)
All rights reserved. No part of this publication may be reproduced, stored
in a retrieval system, or transmitted, in any form or by any means, without the prior written permission of Graphtec Corporation.
(2) The specifications and other information in this manual are subject to
change without notice.
(3) While every effort has been made to supply complete and accurate
information about this product, please address any inquiries about unclear information, possible errors, or other comments to your sales representative or nearest Graphtec vendor.
(4) Notwithstanding the preceding paragraph, Graphtec Corporation assumes
no liability for damages resulting from the use of the information contained herein or of the product.
About Registered Trademarks
Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and elsewhere. Other company names and product names included in this manual are registered trademarks or trademarks of their respective companies.
Copyright
All copyrights regarding this manual belong to Graphtec Corporation.
Conventions Used in This Manual
To promote safe and accurate use of the GL100 as well as to prevent human injury and property damage,safety precautions provided in this manual are ranked into the five categories described below. Be sure you understand the difference between each of the categories.
This category provides information that, if ignored,
DANGER
WARNING
CAUTION
HIGH TEMPERATURE
ELECTRICAL SHOCK
is highly likely to cause fatal or serious injury to the operator.
This category provides information that, if ignored, is likely to cause fatal or serious injury to the operator.
This category provides information that, if ignored, could cause physical damage to the GL100.
This category provides information that, if ignored, is likely to cause burns or other injury to the operator due to contact with high temperature.
This category provides information that, if ignored, is likely to expose the operator to electrical shock.
Description of Safety Symbols
The symbol indicates information that requires careful attention (which includes warnings). The point requiring attention is described by an illustration or text within or next to the symbol.
The symbol indicates action that is prohibited. Such prohibited action is described by an illustration or text within or next to the symbol.
The symbol indicates action that must be performed. Such imperative action is described by an illustration or text within or next to the symbol.
Safety Precautions
In the event of a malfunction, remove the batteries and do not attempt to use the device.
Attempting to use the device when
malfunctioning may cause an electrical shock or fire. Remove the batteries immediately and request repairs.
Do not use the device in the event that it is producing smoke, is unusually hot, is producing an unusual smell, or other similar circumstances.
Attempting to use the device when
malfunctioning may cause an electrical shock or fire. Immediately move the device to a non-flammable location and, after confirming it is safe, remove the batteries and request for repairs.
Do not allow the device to get wet.
This can cause an electrical
shock or fire hazard. Be especially careful when using the device near windows during rain or snow or in coastal areas.
If fluid or foreign matters enters inside the GL100, turn off the Power switch and disconnect the power cord from the electrical socket.
Use in such status may cause a fire hazard
due to electrical shock or current leakage.
Contact your sales representative
or nearest Graphtec vendor to request repair.
Safety Precautions
Do not put the device in any of the following places when installing it:
locations in direct contact with oily smoke or steam
• locations with direct sunlight
• locations that experience temperatures outside the operating range
Putting the device into places like these
may cause short circuiting, heat, deformation of the case, electrical shocks, fires and malfunctions.
Do not use the device in locations with severe mechanical vibration or large amounts of electrical static.
Such location may impair the
GL100’s performance.
Use the specified batteries.
Using the device with other batteries may
cause electrical shock or fire hazard.
The batteries and exterior of the
LOGGER may be very hot.
HIGH
TEMPERATURE
Do not touch the device with wet hands.
This can cause an electrical
shock or malfunction.
When using the GL100-WL, note the following:
If you have an implantable pacemaker or
implantable defibrillator installed, radio signals from the device may have an effect on the operation of your implantable pacemaker or implantable defibrillator.
When using the GL100-WL, note the following:
Turn off the device in places where
wireless radio signal use is restricted, such as on aircrafts and in hospitals. The device can have an effect on electronic devices, medical devices, etc., and may cause malfunctions.
Do not use the device in any way not specified in this instruction manual. There is a danger that protective provisions will have not been put in place.
This GL100 is not meant for use with lifesaving devices or devices with mission-critical high reliability or high safety requirements (medical devices, aerospace devices, shipping devices, nuclear power devices, etc.). In the event that this GL100 causes injury or property damage when used under these circumstances, the maker assumes absolutely no responsibility and is not liable.
WARNING
Do not use the device for unintended purposes.
Do not use the device for uses other than
measuring.
Do not insert foreign objects into the device.
Inserting metallic objects or flammable
objects into the device may cause an electrical shock or fire.
Keep away from children.
Do not setup the device in a place within
the measuring location that children can reach. They may swallow the device and/or injure themselves.
Do not use the device if it is damaged.
This can cause an electrical
Use prohibited Use prohibited
Avoid water
Use prohibited Use prohibited
shock or fire hazard.
Never disassemble or remodel the GL100.
Modifying this GL100 may
cause an electrical shock or fire due to short circuiting and generating heat.
Do not input voltage that exceeds the permissible input voltage range that is specified on the GL100’s label.
Exceeding the specified
voltage input range may cause electrical shock or a fire hazard.
No disassembly
CAUTION
Do not put heavy objects on top of the device nor climb on top of the device.
Loss of balance may cause falling, which
may cause injury or malfunction.
Do not insert fingers or other foreign objects into connectors or gaps in the device.
This can cause injury or malfunction.
Do not clean the logger using a volatile solvent (such as thinner or benzine).
Cleaning with volatile solvents
may impair the GL100’s performance. If the GL100 becomes dirty, wipe it with a
Prohibited Prohibited
Strict
observance
Don't touch
with wet hands
Strict
observance
Prohibited Prohibited
Prohibited Prohibited
clean, soft cloth.
Be careful of gradual deterioration over time.
Vibration and/or gradual deterioration
over time may cause battery terminal contacts to not work properly.
Be careful of static electricity.
Static electricity may damage the
device. To prevent this from happening, touch a different metal object to discharge any built-up static electricity before touching the GL100.
Remove the batteries when the device is not used for long periods.
Battery leakage may cause
malfunction.
When using the GL100-WL in a medical establishment, note the following rules:
Please turn off the power of this product
in hospital wards..
Each medical institution has
its own usage prohibitions in various areas. Be sure to follow these.
When using the GL100-WL, note the following:
In the event that the device has an effect
on automatic electronic devices such as cars or elevators, immediately turn the GL100-WL off.
The module connection terminal is for use only with separately sold sensors and modules. Do not connect any other devices. Doing so may damage the GL100.
CAUTION
Strict
observance
Strict
observance
503-10 Shinano-cho, Totsuka-ku Yokohama 244-8503, Japan
August 1, 2014
GL100-UM-851
QUIT
STATUS
POWER
ENTER
MENU
START
STOP
2
Preparations Before Measurement
3 Operating Procedure 4 Measurement Procedure
GL100 Series
GL100-N/GL100-WL
Quick Start Guide
Thank you very much for buying this GRAPHTEC product. This product can measure according to the application by
connecting a wide variety of measurement sensors, terminals, and adapters (hereafter "modules"), which are sold separately from the GL100-N/GL100-WL.
These directions describe preparations and cautions before measurement.
For connection and operation instructions for each module, please refer to the corresponding USER'S MANUAL.
To ensure safety, please read the operation instructions, etc. For details on the warnings and how to handle this module, please
read the USER'S MANUAL included on the CD-ROM (included in the GL100 packaging)
Confirmation of the exterior
After opening the package, please confirm that there are no problems (scratches and dirt) on the exterior before use.
Confirmation of the attached items.
Quick Start Guide (this book): 1 •CD-ROM: 1
USB cable (MicroB-A approximate 0.5 m): 1
If by any chance faults are found, please contact the store where you bought the item.
* Please note that items mentioned in this book may change without
prior notice.
MANUAL-GL100-E604309261
1 Part Names
This section describes the name and function of each part.
9. Hook bracket
Within connector cover
4. microSD slot
5. USB I/F terminal
6. Alarm output terminal
1. Monitor ..........................
2. Operation key ...............
3.
Module connection terminal ...
4. microSD slot .................
5. USB I/F terminal ...........
6. Alarm output terminal ....
7. Battery cover .................
8. Mounting screw holes ...
9. Hook bracket .................
10. Connector cover .........
1. Monitor
7. Battery cover
10. Connector cover
2. Operation key
3. Module connection terminal
8. Mounting screw holes
The settings and measured values are displayed. Key operation is performed on the screen.
MENU key :
Information about the measurement condition settings and this module is displayed.
key : Used to select when operating the menu.
ENTER key :
QUIT key :
Used to confirm when operating the menu. Used to return to the previous screen or display
the free-running screen when setting the menu.
START/STOP key : Used to start/stop the measurement.
STATUS lamp :
The measurement information of this module
is displayed in orange.
POWER lamp :
The power supply status is displayed in green. Used to connect to various measurement module. Used to insert microSD card. Used to communicate and power supply with USB cable. Alarm signal is output from this terminal. Two AA batteries are housed in the alkaline battery cover. The size of the mounting screw holes is M4 × L5. A metal fixing that suspends and secures the product. This is the cover for each connector.
This module can be powered by alkaline batteries, an AC adapter (USB cable connection) or a PC (USB cable connection).
* When the power is supplied, it is ready for operation by holding down the
[MENU] key.
1. How to install the batteries
(3) Insert 2 size AA
alkaline batteries.
*Make sure to insert the
batteries the right way.
(2) Remove the
back cover.
(1) Loosen the screws
on the back cover.
(4) Attach the back cover
and tighten the screws.
Make sure to use two size AA alkaline batteries. Do not use zinc-carbon batteries or nickel hydride (rechargeable) batteries.
2. How to connect to power supply (USB cable connection)
(1) Connecting AC adapter Connect this module to a
commercial AC adapter using a USB cable.
Make sure to use an AC adapter rated 5V (at least 1A)
Smartphone chargers cannot be used, because they
usually have overcharge protection lines that may identify this module as being fully charged and stop output.
(2) How to connect to PC
Use the attached USB cable and connect the USB I/F terminal to a PC.
Make sure to use a USB cable connection rated 5V (at least 200mA)
Do not connect via a USB hub.
Reference 1: The recommended power sources for each combination of modules are listed below.
Temperature and humidity measurement 3-axis acceleration / Temperature Measurement 4ch voltage / temperature measurement 4ch thermistor temperature measurement Illuminance / Ultraviolet measurement CO2 measurement AC current / power measurement Temperature and humidity + CO2 measurement Temperature and humidity + illumination / UV measurement CO2 + illumination / UV measurement
*: The GS-DPA listed is a measurement that uses the branch adapter for GS.
A : Full operation B : This works on alkaline batteries. C : This works on alkaline batteries, but power consumption is relatively high, the
operating time will be shorter.
D : Cannot be used as a power source
Setting items
Connect USB I/F terminal.
Sensor module connected
GS-TH GS-3AT GS-4VT GS-4TSR GS-LXUV GS-CO2 GS-DPA-AC GS-DPA+GS-TH+GS-CO2
GS-DPA+GS-TH+GS-LXUV
GS-DPA+GS-CO2+GS-LXUV
Built-in
B B C B B D B D
B
D
USB cable
connection
alkaline battery
A A A A A A A A
A
A
3. How to connect modules
When powered on, the main module will automatically recognize sensors when they are connected. Please connect the module in accordance with the message on the screen.
(1) How to connect modules directly
This module can be connected directly to a sensor.
(2) How to use a branch adapter and connect a module
When using the branch adapter for GS (GS-DPA, sold separately) you can use two modules.
Branch adapter
for GS
Temperature
and humidity sensor
Note: The modules that can be used together are:
• Temperature and humidity sensor + CO2 sensor
Temperature and humidity sensor + illumination / ultraviolet sensor
• CO2 sensor + illumination / ultraviolet sensor
Illumination / ultraviolet
sensor
(3) How to connect using extension cable
When connecting and using the extension cable for GS (GS-EXC, sold separately) between this module and a sensor or a branch adapter for GS, the module’s cable can be lengthened by 1.5 m.
When using a branch adapter, please connect it to the module
after attaching the module to the branch adapter.
The sensor module cannot be recognized when it is attached
directly after the branch adapter has been connected to the module. If it is not recognized, please reconnect it.
Do not connect a main module other than connectable
modules to branch adapter.
CO2 sensor
1. Measurement condition setting
After connecting a module, a variety of measurement settings are enabled. (1) Press [ENTER] key after
connecting the module.
GL 10 0-* *                
 S le epi ng! !                E NT ER  key  t o s ta rt   
QU IT  ke y t o  Pow er  Of f
BA T  LAN                    
•When the message above is displayed, the module can bereplaced.
•When the [QUIT] key is pressed during this message is displayed, it goes into power-off mode. The GL100 is ready for operation by holding down [MENU] key.
(2) The sensor conditions are
loading into the product.
 G L1 00 - ** *           I ni ti a li zi ng!!  
When the message above is displayed, the module should not be replaced.
(3) After processing, free-running screen is displayed.
1. Data recording status display
STOP :
Recording stoppped
ARMED
:
Awaiting recording start
REC
: Recording
8. Measured value display
4. Battery replacement display
5. LAN: displayed when the wireless
2. Alarm display
RE C    A LM.           1:2 8
   +0 .0 1 V     L: OF F    +0 .1 0 V     L: OF F    +0 .5 0 V     L: OF F    +1 .0 0 V     L: OF F
BA T  LAN  SD      S :3 0.0 s
LAN connection is enabled.
3. Current time
9. Logic etc. settings display
7. Sampling interval
6. Displayed only when accessing SD card
(4) Pressing [MENU] key goes to setting menu mode.
1. Setting mode display
3. Settings Display
Press the and operation keys to move the cursor. The item the cursor is on can be changed.
Reference 2: Example settings listing for a 4ch voltage / temperature terminal sensor module.
Page
1/10
AMP
2/10
LOGIC
3/10
DATA
4/10
TRIGGER
5/10
ALARM
6/10
I/F
7/10
MAIL
8/10
OTHER-1
9/10
OTHER-2
10/10
INFORMATION
A MP ]                 1/1 0 CH     In put     Ra ng e     AL L:  TE MP▽     TC -K ▽    
Setting mode
2. Setting mode
1:  T EMP ▽    T C-K ▽     2:  T EMP ▽    T C-K ▽     3:  T EMP ▽    T C-K ▽     4:  T EMP ▽    T C-K ▽    
4. Setting items
Press the [ENTER] key to display the setting screen for the item with displayed (e.g. TEMP ).
Example of items
Input (4ch) Input Mode (4ch) Sampling TRIG Setting Alarm WLAN
(Available for GL100-WL only) Notification (Available for GL100-WL only) Date/Time TEMP UNIT Body, sensor 1, sensor 2
page display
(e.g. 1/10: page 1 of 10) Press the [MENU] key
or use the and keys to change the page.
< Example of operation >
We will now explain the temperature setting procedures for a 4ch voltage / temperature terminal.
1. Press the [MENU] key to display the settings mode screen.
2. Press the key and move to the CH input you want to set.
3. Press the [ENTER] key. Move to TEMP using the and keys, then press the [ENTER] key to select it.
4. Next, move to the range using the and keys, then press the [ENTER] key to select it. Move to TC-K using the and keys, then press the [ENTER] key to select it.
5. Press the [QUIT] key to return to the free-running screen from the setting screen.
Other items can also be set using the same procedure.
The setting items may vary depending on the module connected. Please refer to the USER'S MANUAL for each module.
2. Initial setting (OTHER-1 setting screen)
O TH ER- 1]            7/1 0
Da te /Ti me:  ▽              Sc re en  Sav :O ff▽          LC D  Bri ght ne ss: Of f▽    La ng uag e:   E ngl is h▽    Fa ct ory  IN T:  ▽          
1. Date / Time setting
• Set Date/Time ([ENTER] key).
• Mode: Display mode can be changed
• Date/Time: Use keys to change the date
2. Screen Sav (screen saver) setting After the set amount of time, the screen will automatically turn off.
Press a key to turn the screen back on.
3. LCD brightness setting The LCD brightness can be set to one of four levels.
4. Language setting (The default display language is English.) Onscreen content can be switched between English and Japanese.
5. Factory INT (factory initialization) setting The settings are reset to default values (factory default setting).
The information other than some functions of the language and I/F, etc. will be reset, so please use caution.
1. Measurement start / stop
(1) Set the measurement conditions according to various modules.
(2) Set the settings below when recording the data.
• Set the sampling in DATA setting screen.
• Set the data recording conditions in TRIGGER setting screen.
• When recording the data into the microSD card, insert the microSD card into the microSD slot.
Gently push the microSD card into the slot until it is locked. * Make sure to insert the card
the right way
When mounting, the STATUS lamp will turn on while it checks the amount of available space. Please wait until it turns off.
(3)
Press the [START/STOP] key when the settings are complete to begin measuring.
microSD slot
microSD
When ejecting the microSD card, push it in gently, then remove the card.
(4) To stop the measurement, press the [START/STOP] button once more.
After stopping, data will be written onto the microSD card. Please do not remove the card until the module’s STATUS lamp turns off. Removing the microSD card too early may cause data to not be written correctly.
5
Wireless LAN Connection (GL100-WL only)
1. Connecting Wireless LAN (GL100-WL only)
When using a wireless LAN connection, it is necessary to set a receiving PC, cell phone connection, etc. (For details, refer to the USER'S MANUAL (PDF) on the CD-ROM included with this module)
(1) Display I/F screen
(2) Set wireless conditions in WLAN MODE.
AP (base unit), Station (child unit)
(3) Set a variety of other settings
DHCD, TCP/IP, SSID, Security, Key
The communication distance may change depending on the obstructions and structures in the area. Real-time data transfer has a maximum speed of 500 ms. Be sure to check the measurement conditions before use.
I /F ]                  */ * WL AN  Mo de: AP ▽            DH CP :Of f▽                  TC P/ IP:     ▽               SS ID :GL 100 _a 1be ee ▽     Se cu rit y:W PA 2▽           Ke y: *** *** ** *** *▽      
6 Specifications
GL100-N / GL100-WL specifications
Item
Input channel number Input terminal shape Input method External input/output PC I/F
Built-in memory device
Backup function
Monitor Display contents
Wireless LAN (GL100-WL only)
Functions USB I/F
Alarm output type
Memory content Simple waterproof body Vibration proof Rated power
Power supply
Usage environment External dimensions [W×D×H] (approximate) Weight (approximate)
*1: The IP54 can only be used when the GL100 and module are connected, and the connector
503-10 Shinano-cho, Totsuka-ku Yokohama 244-8503, Japan
Wireless LAN
cover and battery cover are closed. We recommend replacing the packing periodically.
This depends on the type of module to be used.
Alarm output 1 channel USB (Micro-B connector) Wireless LAN (GL100-WL only) * ON/OFF can be set (It is set to ON at the factory.) Main Memory: approximate 4.9M Byte External memory: microSD card (Please use a commercially available product) * 1 file cannot exceed 1.9GB. * A microSD card which supports sleep mode is recommended
TS4GUSDHC4 (Transcend) etc. Setup conditions: EEPROM Clock: Backup capacitor Time need for backup during battery exchange: approx. 10 hours (at 23°C) Graphic monochrome display (128×64 dot) Measured values, settings, etc. Note: Recorded data cannot be viewed on this module.
Please use the included application software. Standards: IEEE 802.11b Communication distance: approx. 40 m *
It depends on the surrounding obstacles and environmental conditions Real-time data transfer rate: 500 ms maximum Real-time display, measured data readout, module settings (PC application) Real-time display, measurement data readout, module settings (Android / iOS smartphone application), Email reception function Note: GL100-WL only Insulation switching type by photo coupler Rating: 30V, 50 mA (power dissipation 150 mW) Recorded Data
1
IP54 * Automobile parts Type 1 Class A equivalent GL100-N: Max. 3.0VA, GL100-WL: Max. 3.5VA * It depends on the type of module to be used. AA alkaline batteries 2 pcs., USB Bus power * USB cable for Micro B-A is included.
Batteries and USB AC adapter (5V 1A or more) are not included
-10 to 50°C, 80% RH or less (non-condensing) 66 × 100 × 27 mm (not including protruding parts)
GL100-N : 125 g, GL100-WL : 130 g