Monitor
Remotely
PC
Current
Streamlined Operation
Monitoring
away from facility
Power
Easy Installation
Equipment
Distribution
board
Check on site!
Electric
energy
Monitor or Analyze
Facility Conditions
Agricultural
facility
AC current
sensor
microSD
memory card
Smart
device
Power measurement with GL100 Easy measurement with PC or Smart device
Easy to monitor current and power value.
Power system Main body Adapter
Single phase
Three phase
1 1 1
1 1 2
WLAN
Internet
Internet
Current
sensor
What is the amount
of electricity?
Current /
Power
Accumulated
power
What is
the charge?
Total : 100 kwh
Fee : USD 100.00
Electricity
charges
GL-Connect
for Smart device
Android 4.1 to 6.0 iOS 7/ 8/ 9 (Up to 9.3.4)
Smart devicePC
Adapter for
AC current sensor
WEBSITE: www.graphtecamerica.com/instruments
Monitoring of electric energy
in the distribution board
Easy to install,
collect recorded data with microSD*
GL100-WL/N
Power
* microSD memory card is not included
Compact Datalogger
GL100
Just plug in
Adapter for current sensor AC current sensor (CT)
GS-DPA-AC
Distribution board
GS-AC50A
the sensor
50A 100A
Easy remote monitoring anywhere with Smart device or PC
WLAN
GL100-WL (with Wireless LAN) *
GL100-N (Without Wireless LAN)
* Available in limited region including USA, Europe and some other
countries persuant to local Wireless Telegraphy Act.
Please contact your local representative of Graphtec for more information.
Data capturing time
Item Data capturing time
Built-in memory (approx. 4.9 MB)
microSD memory card
* microSD memory card is not included. (One data file on microSD memory card is limited up to approx 1.9 GB.)
* When GL100 is driven with AA alkaline batteries, battery life is approximately 6 days. (Condition: measuring with AC current sensor,
1 minute sampling interval, saving data into built-in memory, enabling screensaver)
Specifications of GL100
Item Description
Interface
USB USB 2.0 (Micro B connector)
WLAN *1 Standards: IEEE 802.11b
to PC
Display LCD (backlit monochrome, graphical type)
Functions
Using USB
Using WLAN
Output signal Alarm (1 channel), Warning message (it is sent via the e-mail) *1
Power source Battery (Alkaline battery, AA x 2), USB bus-power (5V, 200 mA minimum) *2
Operating environment
External dimensions [W x D x H] Approx. 66 x 100 x 27 mm (exclude protrusion)
Weight GL100-N: Approx. 125 g, GL100-WL: Approx. 130 g
Sampling interval 0.5 sec. to 60 min.
*1: WLAN and mail function are available with the GL100-WL.
*2: Including USB cable as standard accessory. Batteries and AC adapter for USB bus-power are not included.
(recommended to use an AC adapter with rated output of 5 V 1 A or more.)
*3: When the main unit and the sensor module are connected and the connector cover and battery cover are closed,
it corresponds to IP54. AC current sensor adapter and AC current sensor are not supported with IP54.
Software (GL100-APS for PC, GL-Connect for Smart device) *4
Item Description
SupportedOSPC Windows10 / 8.1 / 8 / 7 / Vista (32- or 64-bit)
Smart
*4: Firmware ver.1.12 or later is required in the GL100.
device
(Condition: measuring AC current & power using GS-DPA-AC, 1 minute sampling interval)
Approx. 178 days
Communication distance: approx. 40 m (varies by condition)
Display and output captured data in real-time, Output the saved data,
Control the GL100 from the PC application software
Display and output captured data in real-time, Output the saved data,
Control the GL100 from the PC or Smart device application software, Send warnings via the e-mail
Temperature: -10 ºC to 50 ºC, Humidity: up to 80 % RH (non condensed)
IP classification: IP54 *3
Android : 4.1 to 6.0 (Download from Google Play)
iOS : iOS 7/ 8/ 9 (Up to 9.3.4) (Download from App Store)
Router supporting DDNS (Dynamic Domain Name Server)
Router
Supporting WLAN
Over 2 years
Specifications of adapter for AC current sensor (option)
Item
Type of measurement
Supported sensor
Number of sensors
Measurement accuracy
Rated frequency
Power system
Measurement display
Rated current
Withstand voltage
Sampling interval
Length of cable
Operating environment
External dimensions
Weight
Specifications for AC current sensor (option)
Item Description
Model number GS-AC50A GS-AC100A GS-AC200A
Maximum current 100 Arms 200 Arms 300 Arms
Withstand voltage Between case and output terminal: 2200 V AC, 1 minute
Insulation resistance Between case and output terminal: Min. 100 MΩ at 500 V
Hole size for the wire Dia. 10 mm Dia. 16 mm Dia. 24 mm
Operating environment
Length of cable Approx. 200 mm
Dimensions [W x D x H]
Communication line
Description
Current, Power (calculated value), Electric energy (calculated value)
CT (Current Transducer), clamp-on type * Optional
50 A (GS-AC50A), 100 A (GS-AC100A), 200 A (GS-AC200A)
Up to two (2) sensors
± 2.0% of FS ± 1 digit, at 23 ºC in rated current and frequency, GL100 with GS sensor
50 Hz and 60 Hz
Supported single-phase, single-phase in the center-tapped system, and three-phase
Current, Power, Electric energy (accumulated power during measurement period)
GS-AC50A: 50 A, GS-AC100A: 100A, GS-AC200A: 200 A
Between case and input/output terminal: 1000 V AC, 50/60Hz, 1 minute
0.5, 1, 2, 5, 10, 20, 30 sec. and 1, 2, 5, 10, 20, 30, 60 min.
Approx. 200 mm
Temperature: -10 ºC to 50 ºC, Humidity: up to 80 % RH (non condensed)
[W x D x H] Approx. 46 x 66 x 27.4 mm (exclude protrusion)
Approx. 55 g
Temperature: -10 ºC to 60 ºC, Humidity: up to 80 % RH (non condensed)
Approx. 26.4 x 25.5 x 43.3 mm Approx. 27.4 x 30.5 x 46.2 mm Approx. 48.4 x 35 x 70 mm
3G / T4
GS-AC100A
Supported
Internet
PCmicroSD memory card
GS-AC200A
200A
GL100-WL
Android 4.1 to 6.0 iOS 7/ 8/ 9 (Up to 9.3.4)
• Due to the possibility of equipment or PC failure, the data files of an instrument are not guaranteed to be stored in the memory. Please make a backup of data whenever possible to avoid data loss.
• Brand names and product names listed in this brochure are the trademarks or registered trademarks of their respective owners.
• Items mentioned are subject to change without notice. For more information about product, please check the web site or contact your local representative.
For using equipment in correctly and safely
• User must read and refer to the user manual for instructions. Use only in accordance with user manual.
To avoid malfunction or an electric shock by current leakage or voltage, please ensure a ground connection and use according to the specification.
•
17462 Armstrong Avenue
Irvine, CA 92614
WEBSITE: www.graphtecamerica.com/instruments
KE10224 GR Vol.1