General use ........................................................................................................................................ 10
Door monitoring .................................................................................................................................. 23
Cleaning the condenser filter .............................................................................................................. 23
Defrost water ...................................................................................................................................... 24
Door closing mechanism .................................................................................................................... 25
Power failure ...................................................................................................................................... 25
Door gaskets ...................................................................................................................................... 26
Long term storage .............................................................................................................................. 26
Service ............................................................................................................................................... 27
Piping diagram SF 550 / KP 60 .......................................................................................................... 33
765041976 Rev. 000 3
Page 4
ENGLISH
Thank you for choosing a quality product from Gram Commercial.
This manual will advise you how to install, use and maintain your new product.
Before our products leave the factory, they undergo a full function and quality test. Should
you nevertheless experience problems with the product, then contact your local dealer.
Gram Commercial subsidiaries and dealers placed all over the world are ready to help you.
Gram Commercial supplies warranty on all products.
This warranty is subject to correct use according to specifications, where e.g. common
maintenance and eventual repairs are carried out by Gram Commercial techicians or
technicians approved by Gram Commercial.
Changes in installation and other use of the procuct than prescribed in this manual, might
affect the operation and durability of the product.
The manual is written according to our current technical knowledge. We constantly work on
updating this information, and we reserve the right to make technical changes.
Application
This product is designed for storage of foodstuff at a constant temperature. The product may
not be used for chilling or freezing of foodstuff.
The product is only to be used for the purpose for which it has been expressly designed
(storage of cooled or frozen items). Any other use could cause that the products stored in the
product are not kept at the right temperature.
The manufacturer will not be held liable or responsible for any damage caused by improper,
incorrect or unreasonable use.
765041976 Rev. 000 4
Page 5
Safety information
Important
Description of symbols used in this manual.
Warning
Important If these instructions are not observed, the product might be damaged or
Be aware that Gram Commercial has taken precautions to ensure that the safety of the
product is in order.
Please read carefully the following information regarding safety.
It is important, that everyone who are to use or install the product, to have access to
this manual.
Lacking observation to these instrucions might result in accidents with
personal injury.
destroyed.
This appliance is not intended for use by persons with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been
given supervison or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
The appliance might contain parts with sharp edges in the compressor
compartment, and in the inside compartment.
The appliance is not to be transported on a sack truck, there is a danger of loosing
the balance, causing danger to persons.
Do not pull the power cord to dicconnect the appliance, or when moving the
appliance.
765041976 Rev. 000 5
Page 6
Location
When receiving the product, check the packaging material for damage.
If any damage occurs at the packaging material, it should be considered if the product might
have been damaged too. If the damage is substantial, please contact your dealer.
The transport pallet can be removed by loosening the screws that fasten the pallet to the
product.
This task requires at least 2 persons.The heaviest part of the product is at the top.
Be aware of this, when removing the transport pallet.
Fig.1
If the cabinet has been transported in horizontal position it must stand upright at
least 2 hours before it is started to allow the oil from the compressor to run back.
Because of the heavy weight of the product, the floor might be damaged or
scratched when moving the product.
Correct set up gives the most effective operation.
The product should be located in a dry and adequately ventilated room.
To ensure efficient operation, it may not be placed in direct sunlight or against
heat-emitting surfaces. The product is designed to operate in an ambient
temperature between +16C and +40°C.
765041976 Rev. 000 6
Page 7
Avoid placement of the product in a chlorine/acid-containing environment
(swimming bath etc.) due to risk of corrosion.
The product and parts of the interior is equipped with a protecting film, which
should be removed before use.
Clean the product with a mild soap solution before use.
The set up place must be level and horizontal.
For versions with legs, use the adjustable legs to make sure that the product stands
level and upright.
For versions with castors, the locking devices of the two front castors must be activated,
when the product is in place. The base must be level, and the product may not be placed on
frames or the like.
Fig. 2
765041976 Rev. 000 7
Page 8
General description
Condenser with air filter
Front panel
Display
Compressor
KP 82
Compressor
Gasket
SF 550 / KP 60
Condenser with air filter
Front panel
Display
Air intake
Air distribution plate
Door
Supports
Wall rails
Foot pedal opener
Fig. 3
765041976 Rev. 000 8
Page 9
Electrical connection
Read the text below thoroughly before electrical connection.
The product is intended for connection to alternating current. The connection
voltage (V) and frequency (Hz) are shown on the name plate in the cabinet (see
Fig. 7). Only the supplied cord is to be used.
Never use an extension cord for this appliance!
If a wall socket is placed in a longer distance than the length of the supplied power
cord, contact an electrician to establish a wall socket within the range of the
supplied power cord.
If the product is defective, it must be examined by a service electrician advised by
Gram Commercial during the guarantee period, if it is a product with built-in
compressor.
If it is a product connected to an external compressor unit, it must be examined
by the company who has connected the product to the unit.
Outside the guarantee period, it is advisable to use the service advised by Gram
Commercial, if possible. If this is not the case, assistance is required from
a refrigeration company with knowledge of Gram’s products.
Fig. 4
765041976 Rev. 000 9
Page 10
Always disconnect the power if interruptions in power supply occur, and when electrical parts
are removed/put on, and before cleaning and maintenance of the product.
Repairing of electrical/technical parts may only be performed by a service electrician from
Gram Commercial or an authorised refrigeration company with knowledge of Gram’s
products.
Do not use the product before all coverings are installed, so that live or rotating machine
parts can not be touched.
The product is not to be used outdoor.
All earthing requirements stipulated by the local electricity authorities must be observed. The
plug and wall socket should then give correct earthing. If necessary, contact an electrician.
Make sure the product is switched off at the socket before service is
performed on electrical parts. It is not sufficient to switch off the product
by the START/STOP key as there will still be voltage to some electrical
parts of the product.
General use
Do not block vent holes in the front panel.
Do not damage the refrigeration system parts.
During normal operation, some parts of the refrigeration system in the
compressor compartment might reach high temperatures, and could therefore
cause burns if touching these components.
Do not use electrical devices inside the product.
To ensure correct and efficient air flow in the cabinet, the shaded areas must be
kept free of items. (see Fig. 5)
All items to be stored, that are not wrapped or packed, must be covered in order
to avoid unnecessary corrosion of the inner parts of the cabinet.
If any controller parameters are changed from default, this could cause that the
product is not functioning normally, and harmful temperatures could damage
items that are kept inside the product.
If the product is turned off, wait minimum 3 minutes before turning it on again.
This is to protect the compressor from damage
765041976 Rev. 000 10
Page 11
Fig. 5
765041976 Rev. 000 11
Page 12
Commissioning
Overview of the control panel:
Program selector buttons
Overview of the display:
Program display
- Clock (HCL)
- Temperature curve (PCL, SCL, thawing
program)
Warning symbol
Second display
(Secondary display)
Function bar:
Altering values,
Display
Program
start button
Warning Filter Cleaning
navigation in menus
ON / OFF +
Back button
Third display
(Tertiary display)
First display
(Primary display)
Display of the relevant functions / connection states
Fan
Dry cooling
Unit settings
765041976 Rev. 000 12
Keyboard lock
Defrosting
Alarm
Compressor(s)
Page 13
Connect the cabinet to the mains.
Please note! During maintenance and repairs, it must be ensured that the unit has no
voltage applied to it. So take the plug out of the socket, or shut off the power! It is NOT
sufficient to switch the unit off with the START/STOP button, since the unit in such case
still has the mains voltage applied to it.
Connection, display and loading of the software
Switch the unit on with the on/off button
Once the unit has been connected up, all segments in
the display will light up in white for approx. 3 seconds
(display test).
Subsequently, the selected program will be shown on
the secondary display - "P05" in this case.
The program "P05" controls 2 compressors. Hence
both compressor symbols will light up in blue.
Afterwards, all used segments will be displayed in their
respective colours. The secondary display will also
show the software version - "4.0" in this case.
Finally, the secondary display will show yet another
version number for the software. When this display
ends, the unit is ready for operation, and the
temperature is shown in the primary display.
765041976 Rev. 000 13
Page 14
Initial defrosting of the evaporator
(connection when the unit is cold)
If the unit is in use and it is cold in the room, the program starts with a defrosting cycle:
In connection with this, the display shows the
temperature internally within the unit.
The defrosting symbol is lit up:
Do not use pointed or sharp objects to make defrosting go faster!
Storage program
(connection when the unit is warm)
If the unit is started in a warm state (normal room temperature internally inside the unit), then
it will immediately switch to the storage program
In connection with this, the display shows the
temperature internally within the unit.
765041976 Rev. 000 14
Page 15
Display of the setpoint (temperature
setting) in the storage program
Press the P button, and hold it in.
The display then shows the "desired value" and
thereby the temperature setting.
SF 550: -18ºC
KP 60/82: +4ºC
Setting of the setpoint (temperature
setting) in the storage program
Press the P button, and hold it in. The display
then shows the "desired value" and thereby the
temperature setting. When the + or - button is
lightly pressed (the P button continues to be held
in), the value is increased or lowered.
When the P button is released, an auditory signal
is issued and the value is saved. The display once
again will show the internal temperature within the
unit.
765041976 Rev. 000 15
Page 16
Time-controlled cooling "HCL"
This program is time-controlled only. The air temperature and the
temperature of the contents of the cabinet are not taken into account.
Both compressors perform the cooling in parallel. The second
compressor starts 15 seconds after the first one. When the proper
evaporator temperature is attained, the fan will be running audibly with
a very high RPM figure.
The program is selected by pressing the button
When the button is pressed, it will stay lit continuously,
and the P, + and -buttons will blink. The symbol for
the clock will light up. The secondary display will show the
program name "HCL" and the tertiary display the selected
duration in minutes. The symbols for a high fan RPM figure
and operation with 2 compressors will be blinking.
The + and - buttons are used to change the time, and
P
for starting the program.
While the program is running, the time will count down on
the tertiary display. The primary display will show the current
temperature inside the unit. In addition, the connected
elements will now be continuously lit: both compressors,
both fan symbols for a high fan RPM figure in the inner
room.
:
After the preset period of time expires,
an acoustic signal is emitted.
After the signal, defrosting is
commenced (if such is required based
upon the evaporator sensor's
temperature). Then it subsequently
switches to the storage program.
Hence the desired value for the
storage program must always be set
and checked before starting "HCL"!
765041976 Rev. 000 16
Page 17
Temperature-controlled cooling (Hard Chill)
This program cools down to the selected, desired value at full motor
power (controlled with the use of the extra sensor).
Both compressors perform the cooling in parallel. The second
compressor starts 15 seconds after the first one. When the proper
evaporator temperature is attained, the fan will be running audibly with
a very high RPM figure.
The program is selected by pressing the button
After pressingthebutton, it will be lit continuously. The
P
, +and -buttons will be blinking. The curve symbol
for HardChill willlightup.The secondary display shows the
program name"PCL", and the tertiary display the selected,
desiredtemperaturevalue.
The+and-buttons are used to change the desired
value, and P for starting the program.
The primary display will now show the current temperature
in the room, the secondary display the program name "PCL"
and the tertiary display the selected, desired temperature
value. The curve symbol is now continuously displayed. In
addition, the connected elements will now be continuously
lit: compressors, fan symbol.
:
When the desired value is attained, an
acoustic signal will be emitted.
After the signal, defrosting is
commenced (if such is required based
upon the evaporator sensor's
temperature). Then it subsequently
switches to the storage program. Hence
the desired value for the storage
program must always be set and
checked before starting "PCL"!
765041976 Rev. 000 17
Page 18
Temperature-controlled cooling (Soft Chill)
This program gently cools down to the selected, desired value
(controlled using room sensor).
Both compressors perform the cooling in parallel. The second compressor starts 15
seconds after the first one. The fan runs at a high RPM figure.
The program is started by pressing the button
.
Temperature changes with Soft Chill: The program is governed solely by the room
sensor. The air temperature and goods being chilled are thus taken into account. The
elapsed time has no effect on the course of the program. The cooling system works with
start/stop cycles with a gradient up to the preset storage temperature. The process stops
as soon as the temperature value reaches 0 °C, and the controls switch to the storage
program.
After pressingthebutton, it will belit continuously.TheP,
+
and-buttons will beblinking. The curvesymbol for Soft
Chill willlight up. The secondary display shows the program
name "SCL", andthe tertiary display theselected, desired
temperaturevalue. The+and-buttons are used to
changethedesiredvalue, andP for starting the program.
The primary display will now show the current temperature in the
room, the secondary display the program name "PCL" and the
tertiary display the selected, desired temperature value. The
curve symbol is now continuously displayed. In addition, the
connected elements will now be continuously lit: compressors,
fan symbol.
When the desired value is attained, an
acoustic signal will be emitted.
After the signal, defrosting is commenced
(if such is required based upon the
evaporator sensor's temperature). Then it
subsequently switches to the storage
program. Hence the desired value for the
storage program must always be set and
checked before starting "SCL"!
765041976 Rev. 000 18
Page 19
Thawing program
g
In connection with thawing, a defrosting heating element is used,
which is governed by the temperature that the room sensor measures.
The thawing program is only able to start when the desired
temperature value is set to between +2C and +8C.
The pro
starts the function.
ram is started by pressing the button .
When the desired value is attained, an
acoustic signal will be emitted.
After the signal, defrosting is
commenced (if such is required based
upon the evaporator sensor's
temperature). Afterwards, the storage
program is switched to.
SF 550: -18ºC
KP 60/82: +4ºC
Manual defrosting of the evaporator
Manual defrosting is only possible as initial defrosting:
Do not use pointed or sharp objects to make defrosting go faster!
Automatic defrosting of the evaporator
The unit performs automatic defrosting 1 to 8 times daily, when the "PCL",
"HCL" and "SCL" programs have finished. Defrosting cannot be concluded
manually! In connection with this, the internal temperature inside the unit is
shown before the defrosting process commences.
765041976 Rev. 000 19
Page 20
g
The user menu
The user menu is opened by pressing the
button for approx. 3
seconds.
+
Navigate through the menu using the using the
P
menu item is opened with the button
. The + and - buttons increase or decrease the
and - buttons, after which the selected
value. They are also used to navigate around in the submenu ("LAL"). The manner of
procedure is the same in the submenu. Altered values are saved by pressing on
P
(receipt
acoustic signal!). The menu items or the menu are exited by pressing
.
Menu item Description Settings range Factory
settin
DC
Dry cooling function *
Activation: "ON"
Deactivation: "OFF"
OFF
LALLocal alarm (display)
LHL upper boundary value for
LAL
LHd
DA
Dad
BU
CALTemperature offset (sensor
harmonisation)
CA Temperature offset sensor
Delay for LHL
Door alarm 0 = off / 1 = on 1
Delay for door alarm 0 … 15 min 1
Acoustic alarm for LAL 0 = off / 1 = on 1
input A (room sensor)
+25 … -35 °C +25 °C
1 … 120 min / in steps of 5 minutes
60 min
-5 … +5 K / steps of 0.5 K 0.0 K
CE
ALL
DEF
765041976 Rev. 000 20
Temperature offset sensor
input A (room sensor)
Relative (escorted) or
absolute (fixed) alarm limits
Number of defrosting cycles for
each 24 hours
-5 … +5 K / steps of 0.5 K 0.0 K
ESC = escorted / FAS = fixed FAS
0 … 8 4
Page 21
Dry cooling
DRY
Dry cooling function may only be selected via the user menu.
The user menu is opened by pressing the button
approx. 3 seconds. The function can now be switched in or out
P
under the DC menu item, saved with
, after which the menu
for
is exited with
Menu item Description Settings range Factory
DC
Dry cooling function *
Alarm and error messages on the display
Display Explanation
OP
A1
A2
F1
The door is open (or the door switch is closed in another manner).
Door alarm ”dA” was activated.
Local alarm, maximum value was activated (LHL)
Room temperature sensor is defective. The sensor must be replaced by
the service department. The cabinet will still approximately maintain the
preset temperature with the use of an emergency program.
.
Activation : ”ON”
Deactivation: "OFF"
setting
OFF
If ”F2” is shown, the evaporator sensor is defective, or there is extreme
icing up of the evaporator. Initially, the unit must be completely defrosted
one single time (disconnected, after which the cabinet must stand with an
open door for 24 hours), Important - condensation container under the
F2
765041976 Rev. 000 21
unit may run over in connection with this!). If the fault subsequently
continues to be displayed, then the service department must replace the
sensor a quickly as possible. The preset temperature will continue to be
maintained, and the defrosting phase will occur gradually without
temperature restrictions.
Page 22
Display Explanation
If "F3" is displayed, there are problems with the condensation sensor. This
F3*
sensor only protects against overheating, and it has no influence on the
temperature regulation in the cabinet. It ought however to be replaced as
quickly as possible, so the protection against overheating is re-established
F4*‘**
F5
F7*
Faults in the second condensation sensor in connection with units with two
cooling motors (see fault message "F3").
Fault in the temperature sensor for PCL (hard chill). The sensor must be
replaced, contact the service department. Affects only hard chill
Overheating of condenser or undercooling, filter mats or condenser fins
plugged up, fan defective, ambient temperature too high or low (unit not in
operation with ambient temperature of under +10 °C)
*does not apply for models with external cooling motors
** does not apply for the SF 550 / KP 60
Deleting alarm messages
A1
A2
The A1 alarm is deleted by pressing the button P.
!Door must be closed first
The A2 alarm is deleted by pressing the button P.
!The temperature in the cabinet must first be under the desired
maximum temperature (25°C Default)
765041976 Rev. 000 22
Page 23
Door monitoring
When the door is opened, "OP" is shown in the primary display.
An acoustic signal is emitted, and the "A1" message is shown on
the secondary display, if the door at a minimum is open in "Dad",
and "BU" is connected.
The acoustic alarm is deleted by pressing P. The alarm indicator
only or first shuts off once the door has also been closed.
Cleaning the condenser filter
Reminder of cleaning the condenser air filter:
After 600 compressor running hours the filter must be cleaned and it is indicated by warning
lights:
FILTER .
If the cleaning is not completed within 650 hours, the warnings continue, and an acoustic
alarm sounds.
Resetting the FILTER alarm after cleaning the condenser filter:
After cleaning the air filter, the controller must be reset to remove the alarms.
It can only be reset by using a certain key combination.
Push three times followed by pushing three times.
and will disappear after 1 minute.
P
FILTER alarm lights green
765041976 Rev. 000 23
Page 24
Defrost water
The product produces water during defrosting, which is led into a tray under the product or at
the back of the product.
An electrical heating element, placed in the tray, re-evaporates the water.
It is recommended to clean the tray and corresponding parts at least once a year.
Remember to disconnect the cabinet before cleaning.
Be careful not to damage the heating element during cleaning.
Fig.6
765041976 Rev. 000 24
Page 25
Door closing mechanism
The door is equipped with a self-closing system. If the door is opened less than 90, it will
close by itself. If the door is opened more than 90, it will stay open.
The door can be opened by using the foot pedal. This leaves both hands free when placing
foodstuffs the cabinet.
Power failure
In the event of a power failure, the control remembers the temperature setting and restarts
the product when power is restored. If the power failure persists for some time, the control
might revert to the factory setting.
Cleaning
Insufficient cleaning will cause that the product will not work at optimum perfomance, or
eventually it will be defective.
Before cleaning, the product should always be disconnected.
Do not flush the product with water, do not use water jet or steam hose
as this may cause short-circuits in the electrical system.
Cleansing agents containing chlorine or compounds of chlorine as well
as other corrosive means, are not to be used, as they might cause
corrosion to the stainless panels of the cabinet and the evaporator.
The compressor compartment and in particular the condenser must be kept free
from dust and dirt. This is best done by cleaning the compressor compartment
and the condenser air filter with a vacuum cleaner, if dust/flour is the matter.
The air filters on the condenser and the front panel can be removed and cleaned
in hot water (at max. 50°C).
For the external maintenance – use stainless steel polish.
The product should be cleaned internally with a mild soap solution at suitable
intervals and checked thoroughly before it is put into operation again.
765041976 Rev. 000 25
Page 26
Door gaskets
This chapter deals with the importance of a well-functioning door gasket.
Gaskets are an important part of a refrigerator/freezer. Gaskets with reduced functionality,
reduces the tightness of the cabinet. Reduced tightness might cause increased humidity,
internal icing, an iced up evaporator (leading to reduced refrigeration capacity), and in worst
case reduced lifecycle of the cabinet.
Therefore it is important to be aware of the condition of the gasket. Regular
inspection is recommended.
The gasket should be cleaned regularly with a mild soap solution.
If a gasket needs replacement, contact your supplier.
Long term storage
If the product is taken out of operation, and need to be prepared for long-term storage,
clean the inside compartment, the door and door gasket thorougly with a hot soapy damp
cloth.
Eventual remnants of food could create mould.
765041976 Rev. 000 26
Page 27
Service
The refrigerating system and the hermetically sealed compressor require no
maintainance - they merely have to be kept clean.
If refrigeration fails, first investigate whether the unit has been unintentionally disconnected or
switched off at the socket, or whether a fuse has blown.
If it is not possible to find the cause of the refrigeration failure, please contact Gram
service department.
When contacting us please tell us the name and serial number (S/N) / (WWYY) of the
cabinet. This information is stated on the name plate, see Fig. 7.
Input: V Hz W A
Defrost:W
Refrigerant:g
Climate class:
Isolation class:
Suction side: 10 bar
Discharge side: 25 bar
Fig.7
765041976 Rev. 000 27
Page 28
Disposal
The below only concerns the United Kingdom.
Disposal of an old cabinet is only available when we are delivering a new one at the same
time. Cabinets must be fully defrosted and emptied prior to collection.
Gram recognises that our products for the catering market are considered as WEEE when
they become obsolete. To ensure that Gram’s responsibilities are handled correctly and
environmentally friendly, we are signed up the largest Business to Business compliance
scheme in the UK – B2B Compliance
http://www.b2bcompliance.org.uk
B2B Compliance will on our behalf deal with all areas of our responsibilities when
collecting and disposing of equipment which fall under the UK WEEE regulations.
B2B Compliance can be contacted on telephone number 01691 676124.
765041976 Rev. 000 28
Page 29
EC-Declaration of conformity
We, Gram Commercial A/S, declare under sole responsibility that the following products:
Name: SF 950, SF 950plus, SF 550
KP 82, KP 60
Refrigerant: R134a, R404A, R290
To which this declaration relates, is in compliance with all the applicable essential requirements, and other
provisions of the European Council Directive.
Directive of the European Parliament and of the Council: