Gram GEC Series, GEC-30, GEC-6, GEC-15 Operation Manual

OPERATION MANUAL
SERIES GEC
Models
GEC-6
GEC-30
REV. 1A9M06
ENGLISH
SPECIFICATIONS
Display
LCD, height 14.5mm
6/7/7 (Unit weight / Weight / Total pieces)
Pan size (mm)
245 x 355 (W x H)
Dimensions
(mm)
387 x 365 x 117(W x L x H)
Net weight (kg)
3.7kg
Operation
temperature
0 ℃ to +40
RH
Less than 85%
Power
9V / 500mA, AC adaptor; rechargeable battery 6V
Output
RS-232C
Model
GEC-6
GEC-15
GEC-30
Maximal
Capacity
6kg
15kg
30kg
d =
0.2g
0.5g
1g
Precision
1/30000
1/30000
1/30000
DISPLAY AND KEYBOARD
LCD Display
Ø Weight display
Ø Unit weight display
Tot al p ie ces di sp la y
Indicates that battery voltage is low, the battery must be charged.
Indicates that display shows the net weight, after making a tare.
Indicates that weight is stable.
Indicates that the scale is in zero point, if you are not using the tare function.
Indicates the PLU number.
Indicates the accumulated weighing.
Indicates that the high limit of a weight or number of pieces has been configured.
Indicates that the low limit of a weight or number of pieces has been configured.
KEYBOARD DESCRIPTION
To tu rn o ff t he scale.
To tu rn o n th e scale.
To re se t the di sp la y to z er o
To perform a tare
~
Numerical keys and decimal point to introduce data.
Key to delete data
Press this key to activate the alarm in high / low limits function.
Press this key to make weighing accumulations.
Press this key to view the total weight accumulated or the total number of pieces accumulated.
Press this key to save, introduce or modify the weight of a sample.
Memorizes the unit weight of a sample.
Memorizes the number of pieces of a sample.
Change the indicator from the scale pan (A) to external platform (optional) (B).
To vi ew t he g ross weight, net weight or tare weight.
Recall of 24 direct PLU’s
COUNTING PIECES FUNCTION
Introduction of unit weight directly through the keyboard.
1. In weighing mode, use the numerical and decimal key to input the unit weight. (Unit weight in grams)
2. Press the the unit weight will change.
3. If the key is not pressed in 4 seconds, the entered value will be
deleted.
Sampling introduction through number of pieces – Method 1
1. Place a number of pieces on the weighing pan.
2. In weighing mode, use the numerical and decimal keys to input the
number of pieces placed on the pan.
3. Press the key to calculate the unit weight of each piece.
4. If the key is not pressed in 4 seconds, the entered value will be
deleted.
Sampling introduction through number of pieces – Method 2
1. Be sure that the weighing pan is empty and the unit weight display is at
zero.
2. Press the key, the second display will show and the
third will show by default as 100.
3. Use the numerical and decimal keys to input the quantity of pieces.
4. Place the pieces on the weighing pan. The unit weight will be
automatically calculated.
Note: If the scale is connected to an auxiliary platform (B) and the
weighing mode is in B position (auxiliary platform) ), after pressing the
key, the input sampling will continue automatically in mode A
(scale)
Sampling introduction through number of pieces – Method 3
1. Be sure that weighing pan is empty and unit weight display is at zero.
2. Place a number of pieces on the weighing pan.
5. Press the key, the second display will show and the third
the value for default as 100.
3. Use the numerical keys to input the quantity.
4. Remove the pieces from the weighing pan. The unit weight will be
automatically calculated.
Note: If the scale is connected to an auxiliary platform (B) and the
weighing mode is in B position (auxiliary platform) ), after pressing the
key, the input sampling will continue automatically in mode A
(scale)
Sampling introduction through number of pieces – Method 4
If the unit weight is not deleted, add or remove pieces and press the
key to calculate again the unit weight.
Auto-sampling operation.
After the sampling introduction, the scale will automatically do the sampling in mode A (scale) of any small item. Placing a new object on the weighing pan, the scale will automatically do the sampling.
The auto-sampling function can be disabled in configuration menu CAL 1
PLU´S OPERATION
PLU Data setting
Configuration of direct PLU (keys 1 ~24)
1. Input the unit weight of the piece (see sampling introduction section)
2. Press the PLU key , the display will flash the message
3. Select the desired PLU key (1 – 24)
4. Press the PLU key to confirm and save. The message will stop
flashing.
Example
To in pu t the unit weight of a piece of 0.5 g: Press:
1. Press the PLU key, the message will flash.
2. Press the desired PLU key, for example: , the PLU indicator will
show 3 then the symbol will flash.
3. Press again the key, the PLU indicator will show 15 then the
symbol will flash.
4. Press the PLU key to confirm, after a bip the unit weight for PLU 15 will
be of 0.5 g.
Configuration of indirect PLU´s ( 0 ~ 999 )
1. Input the unit weight of the piece (see sampling introduction section)
2. Press the PLU key, the display will show the flashing
message.
3. Use the numerical keys to select the desired PLU number.
4. Press the PLU key to confirm and save. The message will
stop flashing.
l If any data is entered in 30 seconds, the scale will automatically exit of
configuration mode and will return to normal weighing mode.
Recall of PLUs
Recall of a direct PLUs (keys 1 – 24)
l In normal weighing mode, press PLU key once (1 – 24) to access PLU
(bottom key)
l Press again the same PLU key to access to PLU (top key)
Example:
1. Press once the key, the PLU number 3 will be automatically
recalled. The display will show 3 below .
2. Press the same key again. The PLU number 15 will be
automatically recalled. The display will show 15 below .
Recall of an indirect PLU (0 – 999)
1. In normal weighing mode, keep pressed the PLU until the scale gives
a double beep, then release the key.
2. Use the numerical keys to introduce the desired PLU number and then
press the PLU key to recall it.
Change the value of a PLU
1. When the message appears on the display, press the PLU key.
The unit weight value will flash.
2. Change the unit weight value according to previous procedure and press
PLU key to confirm and save.