Graff G-1010 Installation Manual [es, en]

Page 1
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
This faucet complies with ASME/ANSI A112.18.1 and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
Dear Customer Estimado Cliente
ENGLISH
Thank you for selecting our product. We are confident we can fully satisfy Muchas gracias por elegir nuestro producto. Estamos seguros que podemos your expectations by offering you a wide range of technologically advanced satisfacer completamente sus expectativas ofreciéndole una amplia variedad products which directly result from our many years of experience in faucet de productos tecnológicamente avanzados que resultan directamente de and fitting production. muchos años de experiencia en grifos y su producción apropiada.
For care, use soft towel with soap and water only! Under no circumstances should you use any chemicals. For faucets
ATTENTION!
with ORB (oil rubbed bronze) finish please be extra careful not to damage, scuff or ruin the finish during the installation and cleaning!
Installation Instructions l Instrucciones de instalación
~
ESPANOL
Para el cuidado, utilice solamente una toalla suave con jabón y aqua! Bajo ninguna circunstancia no use productos químicos. Con los grifos
ATENCIÓN!
de acabado ORB (bronce frotado con aceite) hay que tener un cuidado especial para no dańar, arańar o destruir el acabado durante su instalación o limpieza!
Ø2-1/4"
(Ø57.5mm)
8" (203.3mm)
4" (101.6mm)
Ø2-31/32"
Modelo
(Ø75.5mm)
Model
1130-LM2-**-T
3-11/32" (85mm)
7-1/16" (179.5mm)
7-21/32" (194.5mm)
Model
1130-C2-**-T
Modelo
8" (203.3mm)
4" (101.6mm)
H C
Ø2-1/4"
(Ø57.5mm)
3-11/32" (85mm)
Ø2-31/32"
(Ø75.5mm)
(74mm)
2-29/32"
1-15/32"
(37mm)
7-1/16" (179.5mm)
7-21/32" (194.5mm)
4" (101.6mm)
Ø2-21/32"
(Ø67.5mm)
8" (203.3mm)
Ø2-21/32"
(Ø67.5mm)
Model
1230-S1-**-T
Modelo
2-61/64" (75mm)
6-49/64" (172mm)
7-23/64" (187mm)
Model
1230-LM2-**-T
Modelo
8" (203.3mm)
4" (101.6mm)
Ø2-21/32"
(Ø67.5mm)
3-7/16" (87mm)
Ø2-21/32"
(Ø67.5mm)
6-49/64" (172mm)
7-23/64" (187mm)
3-21/64" (84.5mm)
3-7/16" (87.5mm)
IOG 2211.10
1
Rev. 6 January 2011
Page 2
This faucet complies with ASME/ANSI A112.18.1
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
Model
1430-S1-**-T
Modelo
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
Installation Instructions l Instrucciones de instalación
Model
1430-S2-**-T
Modelo
4" (101.6mm)
Ø2-13/16"
(Ø71.5mm)
4" (101.6mm)
H
8" (203.3mm)
Ø2-13/16"
(Ø71.5mm)
Model
Modelo
8" (203.3mm)
3-7/16" (87mm)
6-49/64" (172mm)
7-23/64" (187mm)
2-61/64" (75mm)
1430-LM15-**-T
C
4" (101.6mm)
Ø2-13/16"
(Ø71.5mm)
4" (101.6mm)
H
8" (203.3mm)
Ø2-13/16"
(Ø71.5mm)
8" (203.3mm)
2-61/64" (75mm)
6-49/64" (172mm)
7-23/64" (187mm)
Model
1530-C3-**-T
Modelo
C
3-7/16" (87mm)
Ø2-13/16"
(Ø71.5mm)
4" (101.6mm)
H
Ø2-7/16"
(Ø62mm)
Ø2-13/16"
(Ø71.5mm)
Model
Modelo
8" (203.3mm)
Ø2-7/16"
(Ø62mm)
3-1/32" (77mm)
3-15/64" (82mm)
6-49/64" (172mm)
7-23/64" (187mm)
1530-LM10-**-T
C
Ø2-7/16"
(Ø62mm)
4" (101.6mm)
Ø2-9/32"
(Ø58mm)
Ø2-7/16"
(Ø62mm)
8" (203.3mm)
Ø2-23/64"
(Ø60mm)
1-31/64
(37.5mm)
7-31/64" (190mm)
8-1/16" (205mm)
Model
1640-C4-**-T
Modelo
3-3/64" (77.5mm)
IOG 2211.10
7-31/64" (190mm)
8-1/16" (205mm)
2-61/64" (75mm)
3-3/32" (78.5mm)
7-11/16" (195mm)
8-3/16" (208mm)
2
3-5/32" (80mm)
1-3/8"
(35mm)
Rev. 6 January 2011
Page 3
This faucet complies with ASME/ANSI A112.18.1
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
Model
1930-LM14-**-T
Modelo
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
Installation Instructions l Instrucciones de instalación
Model
2130-LM20B-**-T
Modelo
8" (203.3mm)
4" (101.6mm)
2-61/64" (75mm)2-9/16" (65mm)
7-11/64" (182mm)
7-41/64" (194mm)
2-61/64" (75mm)
8" (203.3mm)
4" (101.6mm)
Ø2-61/64"
(Ø75mm)
2-27/32" (72mm)
Ø2-61/64"
(Ø75mm)
3-1/2" (89mm)
7-7/8" (200mm)
7-13/32" (188mm)
3-15/32" (88mm)
4" (101.6mm)
Ø2-41/64"
(Ø67mm)
Model
Modelo
8" (203.3mm)
Ø2-41/64"
(Ø67mm)
2430-LM22-**-T
3-15/32" (88mm)
2-23/32" (69mm)
6-47/64" (171mm)
7-9/32" (185mm)
H
Ø2-1/4"
(Ø57.5mm)
8" (203.3mm)
4" (101.6mm)
Model
Modelo
Ø2-1/4"
(Ø57.5mm)
2530-LM15-**-T
C
3-1/32" (77mm)
7-31/64" (190mm)
8-1/16" (205mm)
3-15/64" (82mm)
IOG 2211.10
3
Rev. 6 January 2011
Page 4
This faucet complies with ASME/ANSI A112.18.1
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
Model
2630-LM24-**-T
Modelo
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
Installation Instructions l Instrucciones de instalación
CANTERBURY COLLECTION 2530-C2-**-T
4" (101.6mm)
Ø2-9/32"
(Ø58mm)
8" (203.3mm)
Ø2-23/64"
(Ø60mm)
8" (203.3mm)
4" (101.6mm)
H
Ø2-1/4"
(Ø57.5mm)
(86.5mm)
3-13/32"
3-3/16"
(81mm)
7-11/16" (195mm)
8-3/16" (208mm)
Ø2-1/4"
(Ø57.5mm)
7-31/64" (190mm)
8-1/16" (205mm)
C
1-15/32"
(37mm)
(74mm)
2-29/32"
4" (101.6mm)
H
Ø2-7/16"
(Ø62mm)
8" (203.3mm)
Ø
2-7/16"
Ø
( 62mm)
Model
1531-C3-**-T
Modelo
C
1-31/64
(37.5mm)
9-1/4" (235mm)
9-27/32" (250mm)
Model
1531-LM10-**-T
Modelo
8" (203.3mm)
4" (101.6mm)
H
Ø
Ø2-7/16"
(Ø62mm)
3-3/64" (77.5mm)
2-7/16"
Ø
( 62mm)
C
2-61/64" (75mm)
3-3/32" (78.5mm)
9-1/4" (235mm)
9-27/32" (250mm)
IOG 2211.10
4
Rev. 6 January 2011
Page 5
This faucet complies with ASME/ANSI A112.18.1
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
Model
1641-C4-**-T
Modelo
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
Installation Instructions l Instrucciones de instalación
Model
2131-LM20B-**-T
Modelo
4" (101.6mm)
Ø2-9/32"
(Ø58mm)
8" (203.3mm)
ØØ2-23/64"
( 60mm)
8" (203.3mm)
4" (101.6mm)
Ø2-61/64"
(Ø75mm)
3-5/32" (80mm)
1-3/8"
(35mm)
9-1/4" (235mm)
9-31/32" (253mm)
2.95"
Ø
( 75mm)
Ø
3-1/2" (89mm)
3-15/32" (88mm)
9-1/4" (235mm)
9-27/32" (250mm)
4" (101.6mm)
Ø2-9/32"
(Ø58mm)
Model
Modelo
8" (203.3mm)
ØØ2-23/64"
( 60mm)
2631-LM24-**-T
3-13/32"
3-3/16"
(81mm)
9-1/4" (235mm)
9-31/32" (253mm)
Model
2531-LM15-**-T
Modelo
8" (203.3mm)
4" (101.6mm)
H
2-1/4"
Ø2-1/4"
(Ø57.5mm)
(86.5mm)
Ø
( 57.5mm)
Ø
C
3-1/32" (77mm)
3-15/64" (82mm)
9-1/4" (235mm)
9-27/32" (250mm)
IOG 2211.10
5
Rev. 6 January 2011
Page 6
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
This faucet complies with ASME/ANSI A112.18.1 and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
CANTERBURY COLLECTION 2531-LC1-**-T
Installation Instructions l Instrucciones de instalación
CANTERBURY COLLECTION 2531-C2-**-T
H
Ø2-1/4"
(Ø57.5mm)
8" (203.3mm)
4" (101.6mm)
ØØ2-1/4"
( 57.5mm)
8" (203.3mm)
4" (101.6mm)
C
(82mm)
3-15/64"
3-13/32" (86.7mm)
9-1/4" (235mm)
9-27/32" (250mm)
H
Ø2-1/4"
(Ø57.5mm)
ØØ2-1/4"
( 57.5mm)
C
(74mm)
2-29/32"
1-15/32"
(37mm)
9-1/4" (235mm)
9-27/32" (250mm)
CANTERBURY COLLECTION 2531-LM34-**-T
8" (203.3mm)
4" (101.6mm)
H
Ø2-1/4"
(Ø57.5mm)
2-1/4"
Ø
( 57.5mm)
Ø
9-1/4" (235mm)
C
3-15/64"
3-17/32" (89.5mm)
9-27/32" (250mm)
CANTERBURY COLLECTION 2530-LC1-**-T
8" (203.3mm)
4" (101.6mm)
H
Ø2-1/4"
(Ø57.5mm)
(82mm)
Ø2-1/4"
(Ø57.5mm)
7-31/64" (190mm)
C
3-13/32" (86.7mm)
8-1/16" (205mm)
(82mm)
3-15/64"
IOG 2211.10
6
Rev. 6 January 2011
Page 7
This faucet complies with ASME/ANSI A112.18.1 and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
Valve Rough Only:
1005 Model
Use with:
1130-LM2, 1130-C2,
1230-S1, 1230-LM2B,
1430-S1, 1430-S2, 1430-LM15,
2130-LM20B, 1
213 -LM20B,
2430-LM22
Sólo la válvula
desbastado:
El modelo 1005
Uso con:
1130-LM2, 1130-C2,
1230-S1, 1230-LM2B,
1430-S1, 1430-S2, 1430-LM15,
2130-LM20B,
2131-LM20B,
2430-LM22
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
Installation Instructions l Instrucciones de instalación
(min. 44.2mm)
Min. Finished Wall
min. 1-47/64"
1"
(25.4mm)
6-35/64" (166mm)
~ 4-51/64" (~122mm)
min. 2-19/32" (min. 66mm)
max. 2-49/64" (max. 70mm)
3-35/64" (90mm)
max. 2-3/4" (max. 69.9mm)
Max. Finished Wall
Valve Rough Only:
1010 Model
Use with:
1530-C3,
1530-LM10, 153 -LM10,
1640-C4, 1
2530-LM15, 1 2530-C2 (Canterbury Collection), 253 -C2 (Canterbury Collection),
1
2530-LC1 (Canterbury Collection), 253 -LC1 (Canterbury Collection),
1
2531-LM34 (Canterbury Collection),
2630-LM24, 1
1531-C3,
1
164 -C4, 253 -LM15,
263 -LM24
Sólo la válvuladesbastado:
El modelo 1010
Uso con:
1530-C3, 1531-C3,
1530-LM10, 1531-LM10,
1640-C4, 1641-C4,
2530-LM15, 2531-LM15,
2530-C2 (Canterbury Collection),
2531-C2 (Canterbury Collection), 2530-LC1 (Canterbury Collection), 2531-LC1 (Canterbury Collection),
2531-LM34 (Canterbury Collection),
2630-LM24, 2631-LM24
Valve Rough Only:
1015 Model
Use with:
1930-LM14
max. 2-3/4" (max. 69.9mm)
(min. 44.2mm)
Min. Finished Wall
min. 1-47/64"
Max. Finished Wall
(min. 44.2mm)
Min. Finished Wall
min. 1-47/64"
1"
(25.4mm)
4-9/16" (116mm)
~ 2-13/16" (~71.5mm)
min. 2-19/32" (min. 66mm)
max. 2-49/64" (max. 70mm)
3-35/64" (90mm)
Sólo la válvula
desbastado:
El modelo 1015
IOG 2211.10
Uso con:
1930-LM14
max. 2-3/4" (max. 69.9mm)
Max. Finished Wall
1"
(25.4mm)
6-17/32" (166mm)
~ 4-51/64" (~122mm)
7
min. 2-23/64" (min. 60mm)
max. 2-33/64" (max. 64mm)
2-29/32" (74mm)
Rev. 6 January 2011
Page 8
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
This faucet complies with ASME/ANSI A112.18.1 and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
ENGLISH
For easy installation of your Para la instalación fácil de su grifo GRAFF faucet you will need: de la GRAFF usted necesitará:
l l
to READ ALL the instructions completely before beginning, LEER TODAS las instrucciones completamente antes de
l
to READ ALL the warnings, care and maintenance comenzar, information. LEER TODA la información sobre las advertencias, cuidado
To complete the project, you should:
gather the tools and all the parts you will need,
l l
prepare the mounting area,
l
mount the faucet,
l l
connect the supply lines,
l l
finally test and flush the faucet.
l l
You should have the following tools:
adjustable wrench,
l l
channel pliers,
l l
hex key (included in the box). llave hexagonal (incluido en la caja).
l l
ENGLISH
FLOW RATE INFORMATION INFORMACIÓN DE INTENSIDAD DE FLUJO
Maximum flow rate: 2.2 gpm (8.3l/min.) at 60 psi (4 bar) Flujo máximo 2.2 gpm (8.3l/min.) con 60 psi (4 bar)l l
Installation Instructions l Instrucciones de instalación
l
y mantenimiento.
Para terminar el proyecto, usted debe:
recolectar las herramientas y todas las piezas que usted necesitará, prepare el área para el montaje, monte el grifo, conecte las líneas de fuente,
l
finalmente pruebe y limpie el grifo con un chorro de agua.
Usted debe tener las herramientas siguientes:
llave ajustable, alicates acanalados,
~
ESPANOL
~
ESPANOL
(44.5mm)
min.1-3/4"
Finished wall
Acabado de la pared
SET-UP DIAGRAM l DIAGRAMA DE INSTALACIÓN
8" (203.3mm)
4" (101.6mm)
Ø53/64"
(Ø21mm)
Ø15/16" (Ø24mm)
max.25/32" (20mm)
Finished wall
Acabado de la pared
(69.9mm)
max.2-34"
1
IOG 2211.10
OFF
OFF
ON
g
n
i
n
a
°
0
o
9
e
s
i
w
k
a
c
h
o
l
e
c
r
b
a
e
s
h
e
c
e
p
r
e
d
a
l
a
i
c
8
ON
c
o
u
n
t
e
r
c
s
e
a
b
9
l
o
r
0
c
e
°
k
h
w
a
c
i
i
s
a
e
l
a
o
p
i
z
e
q
n
u
i
i
n
e
g
r
d
a
Rev. 6 January 2011
Page 9
This faucet complies with ASME/ANSI A112.18.1
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
Installation Instructions l Instrucciones de instalación
1
2
5b
5a
3
6
WALL MIN. WALL MIN.
WALL MAX. WALL MAX.
4b
4a
4b 11
12 14
13b
13a
8
~
ENGLISH
1
FAUCET BODY UNIT
2
SEAL O-RING
3
TUBE OF SPOUT
4a,4b
CAP PROTECTION
5a
RIGHT CARTRIDGE (counterclockwise opening)
5b
LEFT CARTRIDGE (clockwise opening)
6
EXTENSION
7
SPOUT BASE
8
SPOUT
9
AEARATOR
10
SCREW
11
HANDLE BASE
12
SHROUD
13a
RIGHT HANDLE (cold water)
13b
LEFT HANDLE (hot water)
14
SCREW
NOTE! For Trim Only ordering please add T at the end of model no., e.g. 1230-S1-**-T ** - finish code, e.g. PC, BN, OB … Finish/color code must be specified when ordering.
NOTA! Pidiendo Sólo el Acabado pongan la “T” al final del número de modelo, e.e. 1230-S1-**-T ** - el código del acabado, e.e. PC, BN, OB … Se debe especificar el código del acabado/color con el pedido.
UNIDAD DEL CUERPO DEL GRIFO SELLADOR DE ANILLO (O-RING) TUBO DEL CAŃO TAPÓN DE PROTECCIÓN CARTUCHO DERECHO (se abre hacia la izquierda) CARTUCHO IZQUIERDO (se abre hacia la derecha) EXTENSIÓN BASE DEL CAŃO CAŃO AIREADOR TORNILLO BASE DE LA MANILLA CHAPA MANILLA DERECHA (agua fría) MANILLA IZQUIERDA (agua caliente) TORNILLO
TM
TM
ESPANOL
1/2 NPT-14 1/2 NPT-14
HOT WATER INLET
ENTRADA DEL
AGUA CALIENTE
109
ROUGH-IN INSTALLATION l INSTRUCCIONES DE DEBASTADO
8" (203.2mm)
4" (101.6mm) 4" (101.6mm)
A A
COLD WATER INLET
ENTRADA DEL
AGUA FRÍA
FIG. 1
1-3/8" (35mm)
MAX. 2-3/4" (69.9mm)
MIN. 1-3/4" (44.5mm)
Finished wall
Acabado de la pared
WALL
WALL
Supply pipe
Tuberia de suministro
2
IOG 2211.10
FIG. 2.1 FIG. 2.2
9
Rev. 6 January 2011
Page 10
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
This faucet complies with ASME/ANSI A112.18.1 and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
ENGLISH
See fig. 2.1 & 2.2 Vea dis. 2.1 y 2.2
Prepare the recess in the wall for the faucet body unit (1) pipe work Prepare la hendidura en la pared para el trabajo de la tubería del cuerpo taking into account the maximum and minimum depth allowed. Arrange del grifo (1) considerando la profundidad máxima y mínima permitida. the pipe work so that the hot water feed is on the left (HOT) and the cold Ubique la tubería de tal modo que el suministro del agua caliente esté a la in on the right (COLD) in relation to the faucet body unit. izquierda (CALIENTE) y del agua fría esté a la derecha (FRIA) de acuerdo Place faucet body unit (1) into the wall recess. Recommended depth for al cuerpo del grifo. faucet body unit in wall measured from center of faucet body unit (1) to Ponga el cuerpo del grifo (1) en la hendidura de la pared. La profundidad finished wall surface is in the range 1-3/4” (44.5mm) - 2-3/4” recomendada para el cuerpo del grifo en la pared medida del centro del (69.9mm). Apply thread sealant to the exposed pipe nipple threads of cuerpo del grifo (1) a la superficie acabada de la pared está en el faucet body unit. Screw on a 1/2" pipe connectors (A) onto faucet body intervalo de 1-3/4” (44.5mm) - 2-3/4” (69.9mm). Aplique sellador unit inlets. Connect HOT water supply to left valve inlet and COLD water para rosca a las roscas expuestas del niple del cuerpo del grifo. Atornille supply to right valve inlet. las piezas de empalme 1/2" (A) en la entrada de la unidad del cuerpo del
Installation Instructions l Instrucciones de instalación
~
ESPANOL
grifo. Conecte el suministro de agua CALIENTE a la entrada de la válvula izquierda y agua FRÍA a la entrada de la válvula derecha.
max.2.75" (69.9mm)
min.1.75" (44.5mm)
Supply pipe
Tuberia de suministro
Finished wall
Acabado de la pared
3 4a
SPOUT INSTALLATION l INSTALACIÓN DEL CAÑO
See fig. 3.1 & 3.2
Remove cap protector (4a) by turning and pulling. Insert spout base (7) over the tube of spout (8).
Slide spout (8) over tube of spout (3) until snug against finished wall. The spout should be located like is shown on “Set-up Diagram” (finished wall has to be between the MAX [2-3/4”] and MIN [1-3/4”]).
Attach spout (8) with hex socket screw (10). Use provided hex key.
Vea dis. 3.1 y 3.2
Quite el tapón de protección (4a) girando y tirando.
Coloque la base del caño (7) en el tubo del caño (8).
Coloque el caño (8) sobre el tubo del caño (3) hasta que toque la pared. El caño debe instalarse tal como se indica en el „Diagrama de Instalación” (la pared acabada tiene que ser entre MAX [2-3/4”] y MIN [1-3/4”]).
Una el caño (8) con el tornillo de zócalo con tuerca hexagonal
FIG. 3.1
(10). Utilice la llave de tuerca hexagonal, proporcionada.
3
ENGLISH
~
ESPANOL
Hex key
Llave hexagonal
3 7
10
HANDLES INSTALLATION l INSTALACIÓN DE LAS MANILLAS
FIG. 4.1 FIG. 4.2
IOG 2211.10
max.2-3/4" (69.9mm)
min.1-3/4" (44.5mm)
WALL
WALL
4b
Supply pipe
Tuberia de suministro
Finished wall
Acabado de la pared
10
8
FIG. 3.2
4
Finished wall
Acabado de la pared
5b6 11 12
Rev. 6 January 2011
Page 11
FIG. 4.3
This faucet complies with ASME/ANSI A112.18.1
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
Installation Instructions l Instrucciones de instalación
FIG. 4.4
FIG. 4.5
D1
6 5b11 12
D2
5b 13b
FIG. 4.7
D1
Cut
Corte
65b 11 12
FIG. 4.6
D2
Cut
Corte
5b 13b
D3
D3
8 13b
ENGLISH
1. If the finished wall installation is between MAX and MIN distances: 1. Para la instalación media entre el MAX y MIN haga lo siguiente: See fig. 4.1-4.7 Vea dis. 4.1-4.7
Remove cap protector (4b) by turning and pulling – see fig. 4.1. Quite el tapón de protección (4b) girando y tirando – vea dis 4.1. Screw on the extension (6) onto the cartridge (5b) – see fig. 4.2. Enrosque la extensión (6) en el cartucho (5b) – vea dis. 4.2.
Insert handle base (11) over extension (6). Holding the handle Coloque la base de la manilla (11) en la extensión (6). Cogiendo base (11) screw on the shroud (12) onto the extension (6) until it rests la base de la manilla (11) enrosque la chapa (12) en la extensión (6) against base. Do not overtighten. Measure (or mark-up) the protruding hasta que se encuentre junto a la base. No apriete demasiado. Mida (o thread on the extension (6) – see fig. 4.2 & 4.3. marque) en la extensión (6) la rosca que sale – vea dis. 4.2 y 4.3.
Unscrew the shroud (12), take off the handle base (11) and Desatornille la chapa (12), quite la base de la manilla (11) y unscrew the extension (6) – see fig. 4.4. desenrosque la extensión (6) – vea dis. 4.4.
Cut-off the protruding part (D1) of the extension (6) at the Corte la parte saliente (D1) de la extensión (6) en el sitio marcado y marked-up place and then screw on the extension (6) onto cartridge nuevamente enrosque la extensión (6) en el cartucho (5b); luego coloque de (5b). Replace handle base (11) and screw on the shroud (12). (NOTE: nuevo la base de la manilla (11) y enrosque la chapa (12). (NOTA: la rosca The thread of the extension (6) cannot protrude above the edge of the de la extensión (6) no puede salir del borde de la chapa (12)) – vea dis. 4.4. shroud (12)) – see fig. 4.4. Inserte la manilla IZQUIERDA (13b) en el cartucho (5b). Mida
Insert LEFT handle (13b) on the cartridge (5b). Measure how por cuánto la manilla (13b) se despega del borde de la chapa (12) – vea much the handle(13b) extends above the edge of the shroud (12) – dis. 4.4 y 4.5. see fig. 4.4 & 4.5. Quite la manilla (13b); mida desde el final del cartucho (5b) la
Take off the handle (13b), measure this distance (D2) from the distancia (D2) y corte en la incisión (ranura) más cercana – vea dis. 4.6. cartridge stem (5b) and cut off at the nearest notch – see fig. 4.6. Nuevamente inserte la manilla (13b) en el cartucho (5b).
Replace the handle (13b) on the cartridge (5b). Test the correct Compruebe la posición correcta de manilla. La manilla debe instalarse tal position of handle. The handle should be located like is shown on “Set-up como se indica en el “Diagrama de Instalación” para la posición “ON”. Diagram” in “ON” position. Displace the handle (13b) from the edge of Aleje la manilla (13b) por ca. 0.02” [0.5mm] (D3) desde el borde de la the shroud (12)by about 0.02” [0.5mm] (D3). Using hex key insert and chapa (12). Usando la llave haxagonal inserte y luego ajuste el tornillo tighten screw (8) underneath handle (13b) – see fig. 4.7. (8) en la manilla (13b) - vea. dis 4.7.
Hex key
Llave hexagonal
~
ESPANOL
Repeat steps for second handle. Make sure that the LEFT handle (13b) is Repita los pasos para el segundo de manilla. Asegurarse de que los on the left cartridge (5b) and the RIGHT handle (13a) is on the right manillas han sido instaladas correctamente, la manilla IZQUIERDA cartridge (5a). (13b) es en el cartucho izquierdo (5b) y la manilla DERECHA (13a) es
IOG 2211.10
en el cartucho derecho (5a).
11
Rev. 6 January 2011
Page 12
FIG. 5
This faucet complies with ASME/ANSI A112.18.1
GRIFO DE DOS MANILLAS MONTADOS EN LA PARED
and CSA B 125 Standards. Este grifo se encuentra conforme con losestandares de ASME/ANSI A112.18.1 y de CSA B 125.
max.2-3/4" (69.9mm)
min.1-3/4" (44.5mm)
Acabado de la pared
TWO HANDLE WALL-MOUNT LAVATORY FAUCET
Installation Instructions l Instrucciones de instalación
Finished wall
2. If the finished wall distance is at MAX value, do not cut the extension (6) and the cartridge (5b) – see fig. 5.
CONGRATULATIONS! Your installation is now complete!
ENGLISH
~
ESPANOL
6 5b 11 12 13b8
Supply pipe
Tuberia de suministro
CARE AND MAINTENANCE l CUIDADO Y MANTENIMIENTO
ENGLISH
Your Graff faucet is designed and engineered in accordance with Su grifo de la Graff esta diseńado y dirigido acuerdo con los the highest quality and performance standards. Be sure not to estándares de funcionamiento y calidad más altos. Este seguro no damage the finish during installation. Care should be given to the dańar las terminaciones del grifo durante la instalación. Cuide el cleaning of this product. Although its finish is extremely durable, it producto manteniendolo siempre limpio. Aunque su acabado es can be damaged by harsh abrasives or polish. Never use extremadamente durable, puede ser dańado por los abrasivos o
abrasive cleaners, acids, solvents, etc. to clean any Graff pulientes ásperos. Nunca utilice limpiadores abrasivos, ácidos, product. To clean, simply wipe gently with a damp cloth and solventes, el etc. para limpiar cualquier producto de la Graff. blot dry with a soft towel. Para limpiar, simplemente use un pańo húmedo y seque con
2. Para la instalación MAX no cortar la extensión (6) y el cartucho (5b) – vea dis. 5.
FELICIDADES! Su instalación esta completa ahora!
5
~
ESPANOL
una toalla suave.
WARRANTY l GARANTÍA
~
ENGLISH
Warranty conditions and warranty registration card are outlined on a Las condiciones de la garantía y la tarjeta del registro de la garantía separate sheet. se encuentran en una pagina separada.
ESPANOL
IOG 2211.10
All dimensions and drawings are for reference only. For details, please refer to actual products.
Todas las dimensiones y dibujos sirven únicamente de referencia. Para consultar detalles, ver los productos.
12
Rev. 6 January 2011
Loading...