Page 1
Operation
Pro 230ES and Pro 270ES Electric
3A2813A
Airless Sprayers
For the application of architectural paints and coatings. For professional use only.
3000 psi (20.7 MPa, 207 bar) Maximum Working Pressure
Important Safety Instructions
Related Manuals
Pro 230ES Model: 262863
EN
3A2817
312830
312015
ti19332a
Pro 270ES Model: 262864
ti19331a
Page 2
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama­tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
WARNING
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
• Improper installation of the grounding plug is able to result in a risk of electric shock.
• When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.
• The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
• Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.
• Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.
• This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated in the figure below.
Ground
ti9164
• Only connect the product to an outlet having the same configuration as the plug.
• Do not use an adapter with this product.
Extension Cords:
• Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that accepts the plug on the product.
• Make sure your extension cord is not damaged. If an extension cord is necessary, use 12 AWG (2.5 mm
• An undersized cord results in a drop in line voltage and loss of power and overheating.
2 3A2813A
2
) minimum to carry the current that the product draws.
Page 3
Warnings
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment.
Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity cre­ates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose assembly, spray gun, and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use Graco conductive or grounded high-pressure airless paint sprayer hoses.
Verify that all containers and collection systems are grounded to prevent static discharge. Do not use pail liners unless they are antistatic or conductive.
Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.
Do not use a paint or a solvent containing halogenated hydrocarbons.
Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Keep pump assembly in a well ventilated area. Do not spray pump assembly.
Do not smoke in the spray area.
Do not operate light switches, engines, or similar spark producing products in the spray area.
Keep area clean and free of paint or solvent containers, rags, and other flammable materials.
Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manufacturer’s safety instructions.
Fire extinguisher equipment shall be present and working.
Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.
Turn off and disconnect power cord before servicing equipment.
Connect only to grounded electrical outlets.
Use only 3-wire extension cords.
Ensure ground prongs are intact on power and extension cords.
Do not expose to rain. Store indoors.
3A2813A 3
Page 4
Warnings
WARNING
SKIN INJECTION HAZARD
High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get immediate surgical treatment.
Do not aim the gun at, or spray any person or animal.
Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with
any part of the body.
Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.
Use Graco nozzle tips.
Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spray-
ing, follow the Pressure Relief Procedure, page 9 for turning off the unit and relieving the pressure before removing the nozzle tip to clean.
Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off
the unit and follow the Pressure Relief Procedure, page 9 for turning off the unit.
Check hoses and parts for signs of damage. Replace any damaged hoses or parts.
This system is capable of producing 3000 psi. Use Graco replacement parts or accessories that are
rated a minimum of 3000 psi.
Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
Verify that all connections are secure before operating the unit.
Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system compo-
nent. See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equip-
ment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.
Do not leave the work area while equipment is energized or under pressure.
Turn off all equipment and follow the Pressure Relief Procedure, page 9 when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufac-
turer’s replacement parts only.
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
Make sure all equipment is rated and approved for the environment in which you are using it.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids
containing such solvents.
Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for
compatibility.
4 3A2813A
Page 5
Warnings
WARNING
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, fol-
low the Pressure Relief Procedure and disconnect all power sources.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swal­lowed.
Read MSDSs to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
RECOIL HAZARD
Gun may recoil when triggered. If you are not standing securely, you could fall and be seriously injured.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is not limited to:
Protective eyewear, and hearing protection.
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer
3A2813A 5
Page 6
Component Identification
Component Identification
W
C
B
K
F
H
J
G
ti19331a
D
E
X
R
Q
M
6 3A2813A
ti9667a
L
S
V
A
ti16978a
T
V (SG2/SG3)
Page 7
Component Identification
A Airless spray gun
B Power switch
C Pressure control knob
Dispenses fluid.
Turns sprayer ON and OFF.
Increases (clockwise) and decreases (counter-clockwise) fluid pressure in pump, hose, and spray gun.
D Pump fluid outlet fitting Threaded connection for paint hose.
E Filter
F
Endurance
Pump
G Suction tube
H Prime tube (with diffuser)
Filters fluid coming out of pump to reduce tip plugging and improve finish.
Pumps and pressurizes fluid and delivers it to paint hose.
Draws fluid from paint pail into pump.
Drains fluid in system during priming and pressure relief.
In PRIME position (pointing down) directs fluid to prime tube.
JPrime/Spray valve
In SPRAY position (pointing forward) directs pressurized fluid to paint hose.
Automatically relieves system pressure in overpressure situations.
K Serial Tag (below sprayer frame)
L Inlet screen
M Paint hose
Q Tip guard
Sprayer model and serial number information
Prevents debris from entering pump.
Transports high-pressure fluid from pump to spray gun.
Reduces risk of fluid injection injury.
Atomizes fluid being sprayed, forms spray pattern and controls fluid flow
R Reversible spray tip
according to hole size.
Reversed, it unclogs plugged tips without disassembly.
S Gun trigger safety lever Prevents accidental triggering of spray gun.
T Gun fluid inlet fitting Threaded connection for paint hose.
V Gun fluid filter Filters fluid entering spray gun to reduce tip clogs.
W Hose wrap Rack Stows paint hose.
X Pail hanger For transporting pail by its handle.
3A2813A 7
Page 8
Installation
Installation
Grounding
The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.
The sprayer cord includes a grounding wire with an appropriate grounding contact.
The plug must be plugged into an outlet that is prop­erly installed and grounded in accordance with all local codes and ordinances.
ti2810a
Power Requirements
100-120V units require 100-120 VAC, 50/60 Hz, 15A, 1 phase.
Use an extension cord with an undamaged ground contact.
If an extension cord is necessary, use a 3-wire, 12
AWG (2.5 mm
2
) minimum.
Pails
Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete.
Do not place pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity.
Do not modify plug! If it will not fit in outlet, have grounded outlet installed by a qualified electrician. Do not use an adapter.
ti5572b
Thermal Overload
Motor has a thermal overload sensor to shut itself down if overheated. If unit overheats, perform Pressure Relief Procedure, page 9, and allow approximately 45 minutes for unit to cool before attempting to resume operation.
ti5850a
Grounding a metal pail: connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground such as a water pipe.
ti5851a
To maintain grounding continuity when flushing or relieving pressure: hold metal part of spray gun
firmly to side of a grounded metal pail. Then trigger gun.
8 3A2813A
ti5310c
Page 9
Operation
WASTE
Operation
Trigger Lock
Always engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped.
ti8908a
Trigger Locked
ti8909a
Trigger Unlocked
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever you see this symbol.
This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.
3. Trigger gun to relieve pressure.
ti2599a
WASTE
4. Turn prime valve down.
ti2719a
If you suspect spray tip or hose is completely clogged, or that pressure has not been fully relieved after follow­ing these steps, VERY SLOWLY loosen tip guard retain- ing nut or hose end coupling to relieve pressure gradually, then loosen completely. Now clear tip or hose obstruction.
1. Turn power OFF and unplug sprayer.
ti2707a
2. Turn pressure to lowest setting.
-
TIB
3A2813A 9
ti2718a
Page 10
Setup
Setup
1. Turn OFF power switch.
ti2707a
2. Turn Pressure Control Knob all the way left (counter-clockwise) to minimum pressure.
-
ti2614a
5. Connect other end of hose to sprayer.
ti9674b
NOTE: If hose is already connected, make sure connec­tions are tight.
6. Check inlet strainer for clogs and debris.
3. Unscrew tip and guard assembly from gun.
ti9714a
4. Uncoil hose and connect one end to gun. Use two wrenches to tighten securely
ti9681a
ti2812a
7. Fill throat packing nut with TSL to prevent premature packing wear. Do this each time you spray.
Approximate Fill Level
10 3A2813A
Page 11
Prime and Flush Storage Fluid
Before you use your sprayer for the first time or begin a new spraying project, you need to prime the sprayer and flush the storage fluid out of the sprayer.
Oil- or Water-based Materials
When spraying water-based materials, flush the system thoroughly with water.
Setup
2. Separate prime tube (smaller) from suction tube (larger).
When spraying oil-based materials, flush the sys- tem thoroughly with mineral spirits or compatible, oil-based flushing solvent.
To spray water-based materials after spraying oil-based materials, flush the system thoroughly with water first. The water flowing out of prime tube should be clear and solvent-free before you begin spraying the water-based material.
To spray oil-based materials after spraying water-based materials, flush the system thoroughly with mineral spirits or a compatible oil-based flush­ing solvent first. The solvent flowing out of the prime tube should not contain any water.
When flushing with solvents, ground pail and gun. Read Grounding and Electric Requirements, page
8.
To avoid fluid splashing back on your skin or into your eyes, always aim gun at inside wall of pail.
ti2039a
3. Place prime tube in waste pail.
4. Submerge suction tube in water or flushing solvent.
ti9651a
5. Turn Prime/Spray Valve to PRIME.
ti2719a
6. Plug sprayer in a grounded outlet.
1. Make sure the power switch is OFF and the sprayer is unplugged.
ti2707a
3A2813A 11
ti2810a
7. Turn power switch ON.
ti2706a
Page 12
Setup
WASTE
8. Increase pressure to start motor and allow fluid to circulate through drain tube for 15 seconds; then turn pressure down.
-
TIB
9. When sprayer starts pumping, flushing solvent and air bubbles will be purged from system. Allow fluid to flow out of prime tube, into waste pail, for 30 to 60 seconds.
10. Turn power switch OFF.
TIB
a. Point gun into waste pail.
ti2599a
WASTE
b. Unlock gun trigger lock.
ti8909a
c. Pull and hold gun trigger.
d. Turn Prime/Spray valve to SPRAY.
ti2712a
11. Transfer suction tube to paint pail and submerge suction tube in paint
.
ti9653a
12. Turn power switch ON.
ti2706a
13. When you see paint coming out of prime tube:
14. Continue to trigger gun into waste pail until you see only paint coming out of gun.
15. Release trigger. Engage trigger lock.
ti8908a
NOTE: Motor stopping indicates pump and hose are primed with paint. If motor continues to run the sprayer is not properly primed. To reprime, turn Prime/Spray valve to PRIME and repeat step 13.
16. Transfer prime tube to paint pail and clip prime tube to suction tube.
12 3A2813A
Page 13
Setup
Install Tip and Guard on Gun
1. Engage trigger lock.
ti8908a
2. Verify tip and guard parts are assembled in order shown.
retaining nut
guard
tip
black rubber gasket and
metal seat
ti8911a
Spraying Techniques
Preventing Excessive Tip Wear
Spray should be atomized (evenly distributed, no gaps at edges). Start at low pressure setting, increase pressure a little at a time until you see a good spray pattern, without tails.
Spray at lowest pressure that atomizes paint.
If maximum sprayer pressure is not enough for a good spray pattern, tip is too worn.
tails-gaps at edges
pressure too low
good spray pattern
ti5592a
Use tip to align seat in guard
ti9574a
Tip must be pushed all the way into guard
ti5606a
3. Screw tip and guard assembly on gun. Tighten retaining nut.
ti9713a
4. Ensure spray tip arrow is pointed forward to spray position.
NOTE: If tails persist when spraying at the highest pres­sure, a smaller tip is needed or the material may need to be thinned.
Adjust Spray Pressure
This sprayer is set up for most airless spraying applica­tions.
NOTE: Motor only runs when gun is triggered. Sprayer is designed to stop pumping when gun trigger is released.
Turning knob to right (clockwise), increases pres­sure at gun.
Turning it left (counter-clockwise), decreases pres­sure.
General spraying instructions are provided in Get­ting Started section of this manual, page 14.
3A2813A 13
ti9049a
Page 14
Setup
Getting Started
Use a piece of scrap cardboard to practice these basic spraying techniques before you begin spraying the sur­face.
Hold gun 12 in. (30 cm) from surface and aim straight at surface. Tilting gun to direct spray angle causes an uneven finish.
12 in. (30 cm)
even finish
Flex wrist to keep gun pointed straight. Fanning gun to direct spray at angle causes uneven finish.
even finish thin thick thin
thick
uneven
finish
ti5585a
thin
ti2036a
Unclogging Spray Tip
Do not operate or spray near children. Do not aim the sprayer at, or spray any person or animal. Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.
Occasionally, debris from material can accumulate and clog the spray tip. Perform the following steps to unclog the tip.
1. To unclog tip obstruction, engage trigger lock.
ti11309a
2. Reverse spray tip to UNCLOG position.
Triggering Gun
Pull trigger after starting stroke. Release trigger before end of stroke. Gun must be moving when trigger is pulled and released.
TIA
Aiming Gun
Aim tip of gun at bottom edge of previous stroke, over­lapping each stroke by half.
ti2038a
ti9048a
NOTE: Trapped pressure in the gun and paint hose may make the spray tip very difficult to turn. If so, perform the Pressure Relief Procedure, page 9, before rotating spray tip.
3. Aim gun at waste area, disengage trigger lock. Pull trigger to clear clog.
ti11308a
14 3A2813A
Page 15
Setup
4. Engage trigger lock. Rotate spray tip back to SPRAY position.
ti11309a ti9714a
5. Disengage trigger lock and resume spraying.
ti11308a
6. If the tip is still clogged, you may have to repeat steps 1 - 5 and rotate the tip from SPRAY to UNCLOG several times.
To help reduce tip clogs:
strain the paint to remove debris
repeat step 1 to relieve pressure
remove and clean gun filter.
7. If obstruction is cleared, engage trigger lock and rotate arrow-shaped handle back to SPRAY position.
ti11309a
ti9049a
3A2813A 15
Page 16
Shutdown and Cleaning
Shutdown and Cleaning
Flushing
For short term shutdown periods (overnight to two days) refer to Short Term Storage, page 19.
For flushing after spraying oil-based coatings, use compatible oil-based flushing fluid or mineral spirits. Read Priming and Flushing Storage Fluid, page 11.
For flushing after spraying water-based coatings, use water. Read Priming and Flushing Storage Fluid, page 11.
1. Relieve pressure, page 9.
2. Remove tip and guard assembly from gun and place in flushing fluid.
3. Lift suction tube and prime tube from paint pail. Let them drain into paint pail for a while.
6. Place prime tube in waste pail.
ti9652a
7. Submerge suction tube in water or flushing solvent.
ti2714a
FLUSH
8. Turn pressure control knob to minimum setting.
-
4. Separate prime tube (smaller) from suction tube (larger).
ti2039a
5. Place empty waste and water or solvent pails side by side.
ti2756b
WASTE
ti2756B
FLUSH
ti2614a
9. Turn power switch ON.
ti2706a
10. Flush until approximately 1/3 of the flushing fluid is emptied from the pail.
16 3A2813A
Page 17
Shutdown and Cleaning
2
a
11. Turn power switch OFF.
ti2707a
NOTE: Step 12 is for returning paint in hose back to paint pail. One 50-ft hose holds approximately 1-quart (1-liter) of paint.
12. To recover paint in hose:
a. Point gun into paint pail.
ti2770a
PAINT
b. Unlock gun trigger lock.
13. While continuing to trigger gun, quickly move gun to redirect spray into waste pail. Continue triggering gun into waste pail until flushing fluid dispensed from gun is relatively clear.
ti9745
PAINT WASTE
14. Stop triggering gun. Engage the trigger lock.
ti8908a
15. Turn prime/spray valve to Prime.
ti2719a
ti8909a
16. Turn power switch OFF.
c. Pull and hold gun trigger.
d. Turn Prime/Spray valve to SPRAY.
ti2712a
ti2707a
17. Clean gun filter and gun, page 18.
e. Turn power switch ON.
18. Fill unit with Pump Armor
storage fluid. Read Long
Term Storage, page 19.
ti
f. Continue to hold gun trigger until you see paint
diluted with flushing fluid starting to come out of gun.
3A2813A 17
Page 18
Shutdown and Cleaning
Cleaning Gun
Clean gun fluid filter (d) with water or flushing sol­vent and a brush every time you flush the system. Replace gun filter if damaged.
d
ti9668a
Remove tip and guard and clean with water or flush­ing solvent. A soft brush can be used to loosen and remove dried-on material if needed.
ti9671a
Wipe paint off outside of gun using a soft cloth moistened with water or flushing solvent.
18 3A2813A
Page 19
Storage
Storage
Short Term Storage
(up to 2 days)
1. Relieve pressure, page 9.
2. Leave suction tube and prime tube in paint pail.
ti9353b
3. Cover paint pail and hoses tightly with plastic wrap.
4. Engage trigger lock.
Long Term Storage
(more than 2 days)
NOTE: Always circulate Pump Armor storage fluid through system after cleaning. Water left in sprayer will corrode and damage pump. Follow Shutdown and Cleaning, page 16.
1. Place suction tube in Pump Armor storage fluid bot­tle and prime tube in waste pail.
ti2057a
2. Turn Prime/Spray valve to PRIME.
ti8908a
5. Leave gun attached to hose.
6. If you have not already cleaned them, remove tip and guard from gun and clean with water or flushing solvent. A soft brush can be used to loosen and remove dried-on material if needed.
ti9671a
7. Wipe paint off outside of gun using a soft cloth moistened with water or flushing solvent.
ti2719a
3. Turn power switch ON.
ti2706a
3A2813A 19
Page 20
Storage
4. Turn pressure control knob clockwise until the pump turns on.
TIB
5. When storage fluid comes out of prime tube (5-10 seconds) turn power switch OFF.
ti2707a
Stowing Sprayer
NOTICE
Before storing sprayer make sure all water is drained out of sprayer and hoses.
Do not allow water to freeze in sprayer or hose.
Do not store sprayer under pressure.
1. Screw inlet screen onto suction tube.
ti2812a
6. Turn Prime/Spray valve to SPRAY to keep storage fluid in sprayer during storage.
ti2712a
2. Coil hose. Leave it connected to sprayer. Wrap hose around hose wrap bracket.
3. Secure a plastic bag around suction tube to catch any drips.
ti5552a
4. Store sprayer indoors.
20 3A2813A
Page 21
Maintenance and Service
Maintenance and Service
NOTICE
Protect the internal drive parts of this sprayer from water. Openings in shroud allow cooling of
mechanical parts and electronics inside. If water gets into these openings, the sprayer could malfunction or be permanently damaged.
Caring for Sprayer
Keep sprayer and all accessories clean and in good working order.
ti3388a
To avoid overheating motor, keep vent holes in shroud clear for air flow. Do not cover sprayer while spraying.
Paint Hoses
Check hose for damage every time you spray. Do not attempt to repair hose if hose jacket or fittings are dam­aged. Do not use hoses shorter than 25 ft (7.6 m). Wrench tighten, using two wrenches.
Tips
Always clean tips with compatible solvent and brush after spraying.
ti2055a
Tips may require replacement after 15 gallons (57 liters) or they may last through 60 gallons (227 liters) depending on abrasiveness of paint.
Do not spray with worn tip.
Pump Packings
When pump packings wear, paint will begin to leak down outside of pump.
Replace pump packings at first sign of leaking or additional damage could occur.
Purchase a pump repair kit and install according to instructions provided with kit.
Consult a Graco authorized service center.
3A2813A 21
Page 22
Troubleshooting
Troubleshooting
Problem Cause Solution
Check everything in this Troubleshooting Table before you bring the sprayer to a Graco authorized service cen­ter.
Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle.
Pressure is set at zero pressure. Turn pressure control knob clock-
wise to increase pressure setting.
Motor or control is damaged. Take sprayer to Graco authorized
service center.
Electric outlet is not providing power. • Try a different outlet or plug in
something that you know is work­ing to test outlet.
Reset building circuit breaker or replace fuse.
Extension cord is damaged. Replace extension cord. Read
Grounding and Electric Require­ments, page 8.
Sprayer electric cord is damaged. Check for broken insulation or wires.
Replace electric cord if damaged.
Paint and/or water is frozen or hard­ened in pump.
Unplug sprayer from outlet. If frozen do NOT try to start sprayer until it is completely thawed or you may dam­age the motor, control board and/or drivetrain.
Make sure power switch is OFF. Place sprayer in a warm area for sev­eral hours. Then plug in powercord and turn sprayer ON. Slowly increase pressure setting to see if motor will start.
Motor is hot and runs intermittently. Motor automatically shuts off due to excessive heat. Damage can occur if cause is not corrected.
See Thermal Overload, page 8.
22 3A2813A
Vent holes in enclosure are plugged or sprayer is covered.
Extension cord is too long or not a heavy enough gauge.
Unregulated electrical generator being used has excessive voltage.
If paint is hardened in sprayer, pump packings, valves, drivetrain or pres­sure switch may need to be replaced. Take sprayer to Graco authorized service center.
Keep vent holes clear of obstructions and overspray and keep sprayer open to air.
Replace extension cord. Read Grounding and Electrical Requirements, page 8.
Use electrical generator with a proper voltage regulator. Sprayer requires 120VAC, 60 Hz, 3000-Watt generator.
Page 23
Problem Cause Solution
Troubleshooting
Pump does not prime. Prime/Spray Valve is in SPRAY posi-
tion.
Inlet screen is clogged or suction tube is not immersed.
Pump was not primed with flushing fluid.
Inlet valve check ball is stuck. Remove suction tube and place a
Inlet valve check ball or seat is dirty Remove inlet fitting. Clean or replace
Outlet valve check ball is stuck. Take sprayer to Graco authorized
Suction tube is leaking. Tighten suction tube connection.
Pump does not prime with fluid. Remove suction tube from paint.
Fluids are viscous or sticky. Thin paint per manufacturers guide-
Pump cycles but does not build up pressure.
Pump is not primed. Prime pump.
Inlet screen is clogged . Clean debris off inlet screen and
Suction tube is not immersed in paint. Make sure suction tube is immersed
Suction tube is leaking. Tighten suction tube connection.
Prime/Spray Valve is worn or obstructed with debris.
Pump check ball is stuck. Read Pump does not prime section
Pump cycles, but paint only dribbles
Pressure is set too low. Slowly turn Pressure Control Knob or spurts when spray gun is trig­gered.
Spray tip is clogged. Unclog spray tip, page 14.
Pump fluid filter is clogged. Clean or replace pump fluid filter.
Spray gun fluid filter is clogged. Clean or replace gun fluid filter, page
Spray tip is too large or worn. Replace tip.
Turn Prime/Spray Valve to PRIME position (pointing down).
Clean debris off inlet screen and make sure suction tube is immersed in fluid.
Remove suction tube from paint. Prime pump with water or solvent-based flushing fluid, page 11.
pencil into the inlet section to dis­lodge the ball, allowing pump to prime properly.
ball and seat.
service center.
Inspect for cracks or vacuum leaks.
Prime pump with water or sol­vent-based flushing fluid.
lines.
make sure suction tube is immersed in fluid.
in paint.
Inspect for cracks or vacuum leaks. If cracked or damaged, replace suction tube.
Take sprayer to Graco authorized service center.
in Troubleshooting, page 23.
clockwise to increase pressure set­ting which will turn motor on to build pressure.
18.
3A2813A 23
Page 24
Troubleshooting
Problem Cause Solution
Pressure is set at maximum but cannot achieve a good spray pattern.
Reversible spray tip is in UNCLOG position.
Spray tip is too large for sprayer. Select smaller spray tip.
Spray tip is worn beyond capability of sprayer.
Extension cord is too long or not heavy enough gauge.
Spray gun fluid filter is clogged. Clean or replace spray gun fluid filter,
Pump fluid filter is clogged. Clean or replace pump fluid filter.
Inlet screen is clogged. Clean debris off inlet screen.
Pump valves are worn, or debris is clogging valve.
Material is too thick. Thin material.
Hose is too long (if extra section is added).
Spray gun stopped spraying. Suction tube is leaking, allowing air to
enter.
Spray tip is clogged. Unclog spray tip, page 14.
When paint is sprayed, it runs down
Coat is going on too thick. Move gun faster.
the wall or sags.
When paint is sprayed, coverage is
Coat is going on too thin. Move gun slower.
inadequate.
Fan pattern varies dramatically while spraying.
Pressure control switch is worn and causing excessive pressure variation.
Rotate arrow-shaped handle on spray tip so it points forward in SPRAY position.
Replace spray tip.
Replace extension cord. Grounding and Electrical Requirements, page 8.
page 18.
Check for worn pump valves.
a. Prime sprayer with paint
b. Trigger gun momentarily.
When trigger is released, pump should cycle momen­tarily and stop. If pump con­tinues to cycle, pump valves may be worn.
c. Remove valves and check for
debris.
Remove section of hose.
Tighten suction tube connection. Inspect for cracks or vacuum leaks.
Choose a tip with smaller hole size.
Choose tip with wider fan.
Make sure gun is far enough from surface.
Choose tip with larger hole size.
Choose tip with narrower fan.
Make sure gun is close enough to surface.
Take sprayer to Graco authorized service center.
OR
Sprayer does not turn on promptly when resuming spraying.
24 3A2813A
Page 25
Troubleshooting
Problem Cause Solution
Cannot trigger spray gun. Spray gun trigger lock is locked. Rotate trigger safety lever to unlock
trigger lock, page 9.
Paint is coming out of pressure control switch.
Prime/Spray valve actuates automatically relieving pressure through prime tube.
Paint leaks down outside of pump. Pump packings are worn. Replace pump packings.
Pressure control switch is worn. Take sprayer to Graco authorized
service center.
System is over pressurizing. Take sprayer to Graco authorized
service center.
3A2813A 25
Page 26
Technical Data
Technical Data
Pro 230ES Pro 270ES
Working pressure range 0-3000 psi (0-21 MPa, 0-207 bar)
Electric motor
(permanent magnet DC, TEFC)
Operating horsepower 1.0 1.4
Maximum delivery (with tip) 0.54 gpm (2.05 lpm) 0.70 gpm (2.65 lpm)
Paint hose 1/4 in. x 50 ft (6.4 mm x 15 m)
Maximum tip hole size
Weight, sprayer only 66 lb (30 kg) 72 lb (33kg)
Weight, sprayer, hose & gun 69 lb (31.4 kg) 75 lb (34 kg)
Dimensions:
Length 21 in. (53.3 cm)
Width 20.5 in. (52.1 cm)
Height 39.5 in. (100.3 cm)
Height (handle retracted) 29.5 in (74.9 cm)
Power cord 16 AWG, 3-wire, 10 ft (3.05 m) 14 AWG, 3-wire, 10 ft (3.05 m)
Fluid inlet fitting 7/8” - 14 UNF external thread
Fluid outlet fitting 1/4 NPSM external thread
Inlet screen (on suction tube) #12 mesh (1675 micron)
Wetted parts, pump & hose zinc-plated carbon steel, nylon, stainless steel, PTFE, acetal, chrome plating,
Wetted parts, gun aluminum, brass, carbide, nylon, plated steel, stainless steel, UHMWPE, zinc
Generator requirement 3000 Watt minimum
Electrical power requirement 120 Vac, 60 Hz, 11A, 1 phase
Storage temperature range ◆❖ -30° to 160°F (-35° to 71°C)
Operating temperature range 40° to 115°F (4° to 46°C)
11.0A (120 VDC) (Permanent magnet brushless DC, TEFC)
0.023 in. (0.58 mm) 0.027 in. (0.69 mm)
leather, UHMWPE, aluminum, carbide
5.5A (330 VDC)
When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in pump.
Damage to plastic parts may result if impact occurs in low temperature conditions.
Changes in paint viscosity at very low or very high temperatures can afftect sprayer performance.
26 3A2813A
Page 27
Notes
Notes
3A2813A 27
Page 28
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2012, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
Original instructions. This manual contains English. MM 3A2813