Graco PR70 System User Manual

PR70
Meter, Mix and Dispense Systems Ordering Information
PR70 System Comparisons
PR70e PR70 PR70 PR70v
with LCM with DM with ADM with ADM
System Configured system? No Yes Yes Yes
Number of shots 1 5 50 50 Shots Based on Percentage of stroke Yes No No No Shots Weight Based Shots No Yes Yes Yes Multi-stroke shots (over 100%) No Yes Yes Yes Shot Sequencing No Optional Yes Yes
Local Control Module (LCM) Yes No No No Display Module (DM) No Yes No No
Gel Timer No Yes Yes Yes Run with Automation (PLC) No Yes Yes Yes USB Download No Optional Yes Yes
Fixed Ratio 1:1 to 12:1 1:1 to 12:1 1:1 to 12:1 NA
Ratios
Monitoring
Data Controls
Pressure Monitoring No Optional Optional Optional
Advanced Display Module (ADM) No Optional Yes Yes
Available accessories and configurations
2.5 ft (76 cm) Hoses Accessory Optional Optional Optional Hoses 10 ft (3 m) Hoses Accessory Optional Optional Optional 15 ft (4.6 m) Hoses Accessory Optional Optional Optional
1:1 MD2 Valve Optional Optional Optional Optional
Valves
Tanks,
Accumulators,
Heated Equipment, Accessories
Optional items can be selected from the configurator and are factory installed. Accessories are ordered when you order the machine, but you assemble it onto the machine at your location.
2
How to order your PR70e
STEP 1: Select your PR70e system for air motor size & valve
The four PR70e system part numbers shown below include the fixed ratio PR70e frame, feed system inlet manifold, one MD2 valve, ADM with 6 foot (2 m) umbilical and basic metering pump components. Note that these system part numbers do not include any metering pumps, outlet hoses, feed reservoirs, air inlet moisture trap, foot switch, mixers, shroud etc.
System MD2 Valve Air Motor Required Machine Operation Maximum Maximum Volume Ratio in. (cm) Line Voltage Voltage Working Pressure Air Inlet Pressure
psi (MPa, bar) psi (MPa, bar)
24S054 1:1
24S055 10:1 100-240 V, 50/60 Hz, 24 VDC 3000 (21, 207) 100 (0.7, 7) 24S056 1:1 24S057 10:1
3 (7.6)
4.5 (11.4)
1 Phase - 50 Watts
STEP 2: Determine your pump size based on min / max shot size
Pump Tube Combination Information Power Factor
Volumetric Large Piston Small Piston Minimum Maximum 3 in. 4.5 in. Ratio (X:1) (mm) (mm) Shot Size (cc) Shot Size (cc) Air Motor Air Motor
1 960 960 12.4 71 2 5 1 640 640 8.3 47.3 4 8 1 480 480 6.2 35.5 5 11 1 320 320 4.1 23.7 7 16 1 240 240 3.1 17.7 10 21 1 160 160 2.1 11.8 14 X 1 120 120 1.6 8.9 19 X 1 80 80 1 5.9 29 X
1.5 240 160 2.6 14.8 11 26
1.5 960 640 10.4 59.1 3 6
1.5 480 320 5.2 29.6 6 13
1.5 120 80 1.3 7.4 23 X 2 960 480 9.3 53.2 3 7 2 640 320 6.2 35.5 5 11 2 480 240 4.7 26.6 6 14 2 320 160 3.1 17.7 10 21 2 240 120 2.3 13.3 13 29 2 160 80 1.6 8.9 19 X 3 960 320 8.3 47.3 4 8 3 480 160 4.1 23.7 7 16 3 240 80 2.1 11.8 14 X 4 960 240 7.8 44.3 4 9 4 640 160 5.2 29.6 6 13 4 480 120 3.9 22.2 8 17 4 320 80 2.6 14.8 11 26
5.33 640 120 4.9 28.1 6 14 6 960 160 7.3 41.4 4 9 6 480 80 3.6 20.7 8 18 8 960 120 7 39.9 4 10 8 640 80 4.7 26.6 6 14 10 800 80 5.7 32.5 5 12 12 960 80 6.7 38.4 4 10
X =Pump tube combination is not recommended
3
Loading...
+ 6 hidden pages