Graco InvisiPac, InvisiPac 127568, InvisiPac 127567 Instructions And Parts

Instructions-Parts
InvisiPac Upgrade Kit
To operate 240V InvisiPac units with a three-phase 400V or 480V electrical supply. For professional use only. Not approved in explosive atmospheres or hazardous locations.
127567
400V Transformer Upgrade Kit
127568
480V Transformer Upgrade Kit
Transformer
333349E
EN
Important Safety Instructions
Read all warnings and instructions in this manual and in the InvisiPac system manual 333347. Save all instructions.
WLD
Installation
WLD
J2
2
H
G
WLD
1
4
1
155
WLD
3
4
Installation
All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.
This transformer must be installed by a qualified electri cian to operate 240V InvisiPac units with a three-phase 480V electrical supply.
NOTE: Installing the transformer kit changes the model of the InvisiPac system. Refer to the InvisiPac system manual 333347 for model information.
1. Turn main power switch OFF.
2. Remove front access panel from electrical enclo sure.
6. Mount main electrical enclosure onto transformer enclosure (4) and tighten screws (1).
3. Remove cables from J2 on AWB board to main power switch (H) and main enclosure ground (G).
4. Remove the knockout hole below main power switch (H).
5. Insert grommet (2) in knockout hole.
7. Remove fan panel (155) on transformer enclosure (4).
8. Insert plastic cable bushing (3) through grommet in the top of the transformer enclosure (4) into the bot tom of the main electrical enclosure.