Graco HUSKY 312877C User Manual

Operation
®
Husky
1050 Air-Operated
Diaphragm Pump
1-inch pump with modular air valve for fluid transfer applications See page 3 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure 125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure
312877C
ENG
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
1050A Aluminum
ti13946a
1050P Polypropylene
1050C Conductive
Polypropylene
with End Flange
ti13844a
with Center Flange
1050S Stainless Steel
ti14342a
ti13843a
0359

Related Manuals

Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Pump Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ATEX Certifications . . . . . . . . . . . . . . . . . . . . . . . 3
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pressure Relief Procedure . . . . . . . . . . . . . . . . . 8
Repair or Replace Air Valve . . . . . . . . . . . . . . . . 8
DataTrak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Check Valve Repair . . . . . . . . . . . . . . . . . . . . . . 11
Diaphragms and Center Section . . . . . . . . . . . . 12
Torque Instructions . . . . . . . . . . . . . . . . . . . . . . 15
Related Manuals
Manual Description
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Parts/Kits Quick Reference . . . . . . . . . . . . . . . . 17
Center Section . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Air Valve and Data Monitoring . . . . . . . . . . . . . . 20
Fluid Covers and Manifolds . . . . . . . . . . . . . . . . 24
Seats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Check Balls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Diaphragms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Manifold O-rings . . . . . . . . . . . . . . . . . . . . . . . . 29
DataTrak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Graco Standard Husky Pump Warranty . . . . . . . . 32
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 32
313435 Husky 1050 Air-Operated Diaphragm Pump, Repair/Parts 313597 Husky 1050A UL-Listed Diaphragm Pump, Operation 313598 Husky 1050A CSA-Certified Diaphragm Pump, Operation 313840 DataTrak, Instructions/Parts 406824 Pulse Count Kits, Instructions
2 312877C

Pump Matrix

p
Check the identification plate (ID) for the 20-digit part number of your pump. Use the following matrix to define the components of your pump. For example, pump number 1050A-A01AA1SSBNBNPT represents a Husky 1 inch, 50 gpm aluminum pump (1050A), with aluminum center section (A01), a standard air valve (A), aluminum fluid covers (A) and manifolds with standard ports in inches (1). The pump has stainless steel seats (SS), buna-N check balls (BN), buna-N diaphragms (BN), and PTFE manifold o-rings (PT).
NOTE: Options for seats, check balls, diaphragms, and seals vary for the 1050A, 1050C, 1050P, and 1050S pump models. To build a pump, use the selector tool at www.graco.com or speak with your distributor.
CONFIGURATION NO.PART NO. SERIAL NO.
SERIESDATE CODE
MAX WPR PSI-bar
Pump ID
Pump Matrix
MADE IN
ti14103a
Pump
(1 inch ports, 50 gpm)
1050A
Aluminum
1050C
Conductive Polypropylene
1050P
Polypropylene
1050S
Stainless Steel
Center Section and
Air Valve Material Air Valve/Monitoring Fluid Covers and Manifolds
Aluminum, standard ports, inch Aluminum, standard ports, metric
A2
Conductive polypropylene,
C1
center flange
Conductive polypropylene, end flange
C2
Polypropylene, center flange
P1
Polypropylene, end flange
P2
Stainless steel, standard ports, inch
S1
Stainless steel, standard ports, metric
S2
Aluminum
Conductive
Polypropylene
Polypropylene
A01A Standard A1 A01B Pulse Count A01C DataTrak A01D Remote C01A Standard C01B Pulse Count C01C DataTrak C01D Remote P01A Standard P01B Pulse Count P01C DataTrak P01D Remote
, ‡, or : See ATEX Certifications below.
Check Valve Seats Check Valve Balls Diaphragm Manifold O-Rings
Acetal
AC
Aluminum
AL
Buna-N
BN
FKM Fluoroelastomer
FK
Geolast
GE
Polypropylene
PP
PVDF
PV
Santoprene
SP
316 Stainless Steel
SS
TPE
TP
®
Buna-N
Acetal
AC
Buna-N
BN
Polychloroprene Standard
CR
Polychloroprene Weighted
CW
FKM Fluoroelastomer
FK
Geolast
GE
PTFE
PT
®
Santoprene
SP
316 Stainless Steel
SS
TPE
TP
BN
Polychloroprene Overmolded
CO
FKM Fluoroelastomer
FK
Geolast
GE
PTFE/EPDM Overmolded
PO
PTFE/EPDM Two-Piece
PT
Santoprene
SP
TPE
TP
—PTNone
PTFE

ATEX Certifications

All 1050A (Aluminum) and
1050C (Conductive Polypropylene)
umps are certified:
II 2 GD c IIC T4
312877C 3
1050S (Stainless Steel) pumps with aluminum or conductive poly­propylene centers are certified:
II 2 GD c IIC T4
DataTrak and Pulse Count are certified:
EEx ia IIA T3
II 1 G
Nemko
06ATEX1124

Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equip­ment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric
lamps, and plastic drop cloths (potential static arc).
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords, or turn power or light switches on or off when
flammable fumes are present.
Ground all equipment in the work area. See Grounding instructions.
Use only grounded hoses.
Hold gun firmly to side of grounded pail when triggering into pail.
If there is static sparking or you feel a shock, stop operation immediately. Do not
use equipment until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
Static charge may build up on plastic parts during cleaning and could discharge and ignite flammable materials and gases. To help prevent fire and explosion:
Clean plastic parts in a well ventilated area.
Do not clean with a dry cloth.
4 312877C
Warnings
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest
rated system component. See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Tech-
nical Data in all equipment manuals. Read fluid and solvent manufacturer’s warn­ings. For complete information about your material, request MSDS from distributor or retailer.
Do not leave the work area while equipment is energized or under pressure. Turn
off all equipment and follow the Pressure Relief Procedure in this manual when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with
genuine manufacturer’s replacement parts only.
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and
hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
PRESSURIZED EQUIPMENT HAZARD
Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.
Follow Pressure Relief Procedure in this manual, when you stop spraying and
before cleaning, checking, or servicing equipment.
Tighten all fluid connections before operating the equipment.
Check hoses, tubes, and couplings daily. Replace worn or damaged parts immedi-
ately.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated
hydrocarbon solvents or fluids containing such solvents.
Many other fluids may contain chemicals that can react with aluminum. Contact
your material supplier for compatibility.
PLASTIC PARTS CLEANING SOLVENT HAZARD
Use only compatible water-based solvents to clean plastic structural or pressure-con­taining parts. Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s warnings.
312877C 5

Installation

WARNING
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
Read MSDS’s to know the specific hazards of the fluids you are using.
Route exhaust away from work area. If diaphragm ruptures, fluid may be exhausted
with air.
Store hazardous fluid in approved containers, and dispose of it according to appli-
cable guidelines.
Always wear impervious gloves when spraying or cleaning equipment.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns:
Do not touch hot fluid or equipment.
Wait until equipment/fluid has cooled completely.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:
Clothing and respirator as recommended by the fluid and solvent manufacturer
Protective eyewear, gloves, and hearing protection
Installation
The Typical Installations shown in FIG. 3 and F
IG. 4 are only guides for selecting and install-
ing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.

Tighten Fasteners Before Setup

Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 16.
6 312877C
Installation

Mounting

The pump exhaust air may contain contam-
inants. Ventilate to a remote area. See Air Exhaust Ventilation on page 8.
Never move or lift a pump under pressure.
If dropped, the fluid section may rupture. Always follow the Pressure Relief Proce- dure on page 14 before moving or lifting the pump.
1. Be sure the mounting surface can support the weight of the pump, hoses, and acces­sories, as well as the stress caused during operation.
2. For all mountings, be sure the pump is bolted directly to the mounting surface.
wire to a true earth ground. A ground wire and clamp, Part 238909, is available from Graco.
Polypropylene: Only conductive polypropyl­ene pumps have a ground screw. Standard polypropylene pumps are not conductive. Never use a non-conductive polypropylene pump with non-conductive flammable fluids. Follow your local fire codes. When pumping conductive flammable fluids, always ground the entire fluid system as described.
3. For ease of operation and service, mount the pump so air valve, air inlet, fluid inlet and fluid outlet ports are easily accessible.
4. Rubber Foot Mounting Kit 236452 is avail­able to reduce noise and vibration during operation.

Grounding

The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical cur­rent due to static build up or in the event of a short circuit.
Pump: See FIG. 1. Loosen the grounding screw (GS). Insert one end of a 12 ga. minimum ground wire (R) behind the grounding screw and tighten the screw securely. Connect the clamp end of the ground
GS
R
ti12214a
FIG. 1. Grounding screw and wire
Air and fluid hoses: Use only grounded
hoses with a maximum of 500 ft (150 m) com­bined hose length to ensure grounding conti­nuity.
Air compressor: Follow manufacturer’s recommendations.
Fluid supply container: Follow local code.
Solvent pails used when flushing: Follow
local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts ground­ing continuity.
312877C 7
Installation
Check your system electrical continuity after the initial installation, and then set up a regular schedule for checking continuity to be sure proper grounding is maintained.

Air Line

See FIG. 3 and FIG. 4, pages 10 and 11.
1. Install an air regulator (C) and gauge to control the fluid pressure. The fluid stall pressure will be the same as the setting of the air regulator.
2. Locate a bleed-type master air valve (B) close to the pump and use it to relieve trapped air. Be sure the valve is easily accessible from the pump and located downstream from the regulator.
Remote option: Insert 5/32 OD tubing into the push-to-connect fitting at each pilot and route to your control.
NOTICE
Pilot supply pressure should not exceed main air supply pressure. If pilot supply pressure is too high, the pump could leak air or exhaust excessive air at stall.

Reed Switch

Pulse Count models are intended for use with customer-supplied fluid management or inven­tory tracking systems. Attach an M12, 5-pin female cable to connect the reed switch to your data monitoring system. See Manual 406824.

Air Exhaust Ventilation

Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing.
3. Locate another master air valve (E) upstream from all air line accessories and use it to isolate them during cleaning and repair.
4. An air line filter (F) removes harmful dirt and moisture from the compressed air supply.
5. Install a grounded, flexible air hose (A) between the accessories and the 1/2 npt(f) pump air inlet (D). Use a minimum 3/8 in. (10 mm) ID air hose.
The air exhaust port is 3/4 npt(f). Do not restrict the air exhaust port. Excessive exhaust restriction can cause erratic pump operation.
To provide a remote exhaust:
1. Remove the muffler (T) from the pump air exhaust port.
2. Install a grounded air exhaust hose (U) and connect the muffler (T) to the other end of the hose. The minimum size for the air exhaust hose is 3/4 in. (19 mm) ID. If a hose longer than 15 ft (4.57 m) is required, use a larger diameter hose. Avoid sharp bends or kinks in the hose.
3. Place a container at the end of the air exhaust line to catch fluid in case a dia­phragm ruptures. If the diaphragm rup­tures, the fluid being pumped will exhaust with the air.
8 312877C