Graco Husky 2150 User Manual

Husky 2150 Plastic Pumps
FLUID FLOW
(Pump tested in water with inlet submerged
AIR CONSUMPTION
scfm (m
3
/min)
20
(76)
25
(0.7)
75
(2.1)
50
(1.4)
100
(2.8)
125
(3.5)
150
(4.2)
40
(152)60(227)80(303)
100
(379)
120
(454)
160
(606)
140
(531)
Husky 2150 Performance
A
B
C
D
D
A
B
C
Air-Operated Double Diaphragm
Technical Specifications
Husky 2150 Plastic Pumps Polypropylene PVDF
Maximum fluid working pressure 120 psi (8.4 bar, 0.84 MPa) 120 psi (8.4 bar, 0.84 MPa) Maximum free flow delivery* 150 gpm (568 lpm) 150 gpm (568 lpm) Maximum pump speed 145 cpm 145 cpm Displacement per cycle** 1.03 gallon (3.90 liter) 1.03 gallon (3.90 liter) Maximum suction lift 18 ft (5.48 m) wet or dry 18 ft (5.48 m) wet or dry Maximum size pumpable solids 0.25 in (6.3 mm) 0.25 in (6.3 mm) Maximum operating temperature*** 150°F (65.5°C) 150°F (65.5°C) Maximum diaphragm operating temperature***
PTFE Santoprene Buna-N TPE Fluoroelastomer
Geolast Typical sound level at 70 psi
(4.9 bar, 0.49 MPa) air @ 125 cpm Maximum air consumption 175 scfm (4.9 m3/min) 175 scfm (4.9 m3/min) Air consumption at 70 psi/60 gpm 60 scfm (1.7 m3/min) 60 scfm (1.7 m3/min) Air pressure operating range 20 to 120 psi
Air inlet size 1/2 npt(f) 1/2 npt(f) Fluid inlet & outlet size**** 2 in (51 mm) ANSI-flange 2 in (51 mm) ANSI-flange Weight 49 lb (22 kg) 68 lb (30.8 kg) Weight with stainless steel center section 68.5 lb (31 kg) 87.5 lb (39.6 kg) Instruction manual
* Flow rates are with muffler and do not vary based on diaphragm material ** Displacement per cycle may vary based on suction condition, discharge head, air pressure and fluid type *** Actual pump performance may be affected by prolonged usage at temperature
220°F (104.4°C) 180°F (82.2°C) 180°F (82.2°C) 150°F (65.5°C)
250°F (121.1°C) 150°F (65.5°C)
220°F (104.4°C) 180°F (82.2°C) 180°F (82.2°C) 150°F (65.5°C)
250°F (121.1°C) 150°F (65.5°C)
78 dBa 78 dBa
20 to 120 psi
(1.4 to 8.4 bar, 0.14 to 0.84 MPa)
(1.4 to 8.4 bar, 0.14 to 0.84 MPa)
308550 308550
Performance Charts
updated 2/15
updated 2/15
(8.4, 0.84)
(7, 0.7)
(7, 0.7)
(5.5, 0.55)
(4.1, 0.41)
(2.8, 0.28)
FLUID OUTLET PRESSURE psi (bar, MPa)
(1.4, 0.14)
gpm
(lpm)
120
100
100
A
B
80
C
60
40
D
20
0
20
0
(76)
Husky 2150 Performance
D
40
(152)60(227)80(303)
(Pump tested in water with inlet submerged
FLUID FLOW
A
B
C
100
120
(379)
(454)
140
(531)
160
(606)
150
(4.2)
125
(3.5)
100
(2.8)
75
(2.1)
50
(1.4)
25
(0.7)
/min)
3
AIR CONSUMPTION scfm (m
AIR PRESSURE LEGEND
A
= at 120 psi (8.4 bar, 0.84 MPa) Air Consumption
= at 100 psi (7 bar, 0.7 MPa) Fluid Pressure
B
= at 70 psi (4.8 bar, 0.48 MPa)
C
= at 40 psi (2.8 bar, 0.28 MPa)
D
PROCESS EQUIPMENT CATALOG
Husky 2150 Metal Pumps
FLUID FLOW
(Pump tested in water with inlet submerged
AIR CONSUMPTION
scfm (m
3
/min)
20
(76)
25
(0.7)
75
(2.1)
50
(1.4)
100
(2.8)
125
(3.5)
150
(4.2)
40
(152)60(227)80(303)
100
(379)
120
(454)
160
(606)
140
(531)
Husky 2150 Performance
A
B
C
D
D
A
B
C
Air-Operated Double Diaphragm
Technical Specifications
Husky 2150 Metal Pumps Aluminum Stainless Steel Ductile Iron
Maximum fluid working pressure 120 psi (8.4 bar, 0.84 MPa) 120 psi (8.4 bar, 0.84 MPa) 120 psi (8.4 bar, 0.84 MPa) Maximum free flow delivery* 150 gpm (568 lpm) 150 gpm (568 lpm) 150 gpm (568 lpm) Maximum pump speed 145 cpm 145 cpm 145 cpm Displacement per cycle** 1.03 gallon (3.90 liter) 1.03 gallon (3.90 liter) 1.03 gallon (3.90 liter) Maximum suction lift (DF3666) 20 ft (6.1 m) dry 20 ft (6.1 m) dry 20 ft (6.1 m) dry Maximum size pumpable solids 0.25 in (6.3 mm) 0.25 in (6.3 mm) 0.25 in (6.3 mm) Maximum operating temperature*** 150°F (65.5°C) 150°F (65.5°C) 150°F (65.5°C) Maximum diaphragm operating temperature***
PTFE Santoprene Buna-N TPE Fluoroelastomer
Geolast Typical sound level at 70 psi
(4.9 bar, 0.49 MPa) air @ 125 cpm Maximum air consumption 175 scfm (4.9 m3/min) 175 scfm (4.9 m3/min) 175 scfm (4.9 m3/min) Air pressure operating range 20 to 120 psi
Air inlet size 1/2 npt(f) 1/2 npt(f) 1/2 npt(f) Fluid inlet & outlet size**** 2 in (51 mm) npt(f) 2 in (51 mm) npt(f) 2 in (51 mm) npt(f) Weight 58 lb (26.3 kg)
Weight with stainless steel center section n/a 134 lb (60 kg) n/a Instruction manual
* Flow rates are with muffler and do not vary based on diaphragm material ** Displacement per cycle may vary based on suction condition, discharge head, air pressure and fluid type *** Actual pump performance may be affected by prolonged usage at temperature
220°F (104.4°C) 180°F (82.2°C) 180°F (82.2°C) 150°F (65.5°C)
250°F (121.1°C) 150°F (65.5°C)
220°F (104.4°C) 180°F (82.2°C) 180°F (82.2°C) 150°F (65.5°C)
250°F (121.1°C) 150°F (65.5°C)
220°F (104.4°C) 180°F (82.2°C) 180°F (82.2°C) 150°F (65.5°C)
250°F (121.1°C) 150°F (65.5°C)
78 dBa 78 dBa 78 dBa
(1.4 to 8.4 bar,
0.14 to 0.84 MPa)
20 to 120 psi (1.4 to 8.4 bar,
0.14 to 0.84 MPa)
20 to 120 psi (1.4 to 8.4 bar,
0.14 to 0.84 MPa)
111 lb (50 kg) 130 lb (59 kg)
62 lb (28.1 kg) - Extended
308368 308368 308368
Performance Charts
FLUID OUTLET PRESSURE psi (bar, MPa)
120
(8.4, 0.84)
100
100
(7, 0.7)
(7, 0.7)
(5.5, 0.55)
(4.1, 0.41)
(2.8, 0.28)
(1.4, 0.14)
gpm
(lpm)
A
B
80
C
60
40
D
20
0
20
0
(76)
Husky 2150 Performance
D
40
(152)60(227)80(303)
(Pump tested in water with inlet submerged
updated 2/15
FLUID FLOW
A
B
C
100
120
(379)
(454)
140
(531)
160
(606)
150
(4.2)
125
(3.5)
100
(2.8)
75
(2.1)
50
(1.4)
25
(0.7)
/min)
3
AIR CONSUMPTION scfm (m
AIR PRESSURE LEGEND
A
= at 120 psi (8.4 bar, 0.84 MPa) Air Consumption
= at 100 psi (7 bar, 0.7 MPa) Fluid Pressure
B
= at 70 psi (4.8 bar, 0.48 MPa)
C
= at 40 psi (2.8 bar, 0.28 MPa)
D
PROCESS EQUIPMENT CATALOG
Loading...